| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
25 Jun 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical Division HPPWD Una H
Executive Engineer Electrical Division HPPWD Una HP
Construction of 4 Numbers Type 3 Qtrs. residential accommodation for Police Station Sadar at Una Distt. Una H.P. SH Prov. E.I. therein
2021_PWD_48662_1
PW-EDU-CB-TA-Tender-2020-21- 953-78 Dt-04-06-2021
Open Tender
Electrical Works
Item Rate
730 days
Una HP
Please refer tender document
6 documents required · 6 mandatory
₹350
₹14,000
26 Jun 2021
17 Jun 2021
26 Jun 2021
17 Jun 2021
25 Jun 2021
17 Jun 2021
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group A.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group A.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x1.5 Sq. mm.
2x10Sq.mm.
Supplying and Drawing following size of PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recesed Steel/PVC conduit as required.
3x1.5Sq.mm.
Supplying and fixing of following sizes of steel conduit alongwith the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25mm dia.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and fixing plain pendent with 16/0.20 mm twin twisted, flexible, PVC insulated, cotton braided, copper cable and bakelite pendent holder including connections etc. as required:-
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole.6 Amp Cat-A
Single pole.16 Amp Cat-A
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
(a) Double pole. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-16 way
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Supplying and laying 8 SWG Copper wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
35 Liter capacity water heater (Cat-A)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Providing, Installation, testing and commissioning of ceiling fan without regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- ( Usha-Technixplus BEE 3 Star rated model) or its equivalent make)
a) Ceiling fan 1200 mm sweep Make :-Usha Technix plus or its equivalent make Category-A
Supplying and fixing Fan box of M.S.sheet with iron rod hook 12 mm.in place of junction box complete as required.
Supplying and fixing Fancy wall bracket,single holder size 170x255 GLS 60w.mm.excluding of lamp,complete making connections etc,as required.(Decon make, Cat.No..05OQ or its equivalent make)
S/F of exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc,as required.
Supply and fixing of led fixture 18 W LED Surface Mounted Downlighter Round Shape with minimum system lumen efficacy of 90 lm/W with and P.F.>0.95 with THD<20% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 6000 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV .Driver Output voltage shall be less than SELV Limits for safe operation and maintenance.Wipro Cat. No LD80-171-XXX-60-SM or Equivalent in Philips: SM251C LED20S- 6500 PSU WH or Trilux :Ambiella IND D LED1000-860 ET 01 ET or LT :
Providing and fixing LED Street light 60 watts die cast aluminium housing,AC 85-270 volts ,available color temperature 5700 K,CRI 80,IP rating 66, up to 10KVA electric surge protection complete with all Bracket, accessories,connections,testing and commissioning etc,as required. (Wipro Skyline Code No.LR 02 -671-XXX-57-G2/Clair/Philips make)
Supplying and fixing of sub main wiring with 16 sq.mm.weather proof twin core aluminium conductor cable on the G.I.bearer wire etc,as required.
Supplying and fixing LED Lamp 9 watts 6500 K E-27 ,900 Lumens 240 volts AC.supply 50 HZ in the existing batten holder,pendent holder,wall bracket & bulk head fitting etc, as required.(Tisva cat. No.AL946611X/Panasonic/Philips make)
Providing and fixing LED surface/pendent mounting Tube fixture 9 watts Jaqour make glazed LED batten Cat.No.LSLM01R009XN high quality design aluminium extruded decorative end caps as per best satisfaction of Engineer-in-Charge complete as required.
Supply and fixing of IP40 Led fixture 40 W with Surface Mounted 4 Feet with Polycarbonate diffuser with aluminium housing minimum lumen output 4000 lumens with P.F.>0.95 with THD<10% ,CRI 80,Surge Protection 2 Kv with IP Protection of IP20 .The LEDs with minium life of 50000 burning hours.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V . Driver Output voltage shall be less than SELV Limits for safe operation and maintenance.Wipro Cat. No LL24-541-XXX-57-XX or Equivalent in Philips : BN308C LED40S-6500 L120 PSU WH or Trilux:TRL-X F OTA 4000-857 ET
Supplying and fixing Suspended circular luminaire 20 watts with efficient illumination provides beautiful ambience in open ceiling & collaborative spaces complete with connections etc. as required.Make :-Wipro Cat.No.LD 30-201-36B-40-PL or its equivalent make
MOLHOTRA ELECTRICALS
Rohini Enterprises
NITIN PROP A VIGHNA ELECTRICALS
stage.html
html • 0.02 MB
finance_72942.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .