| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹40.9 L+₹1.0 L (2.62%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹43.5 L+₹3.7 L (9.19%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹43.9 L+₹4.1 L (10.3%)Rejected-Finance MURSTEY COLONY PLOT NO 16 LEH 194101 LADAKH | LEH LADAKH | LADAKH | 194101 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹46.4 L+₹6.6 L (16.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹47.8 L
EMD Value
₹95,600
Closing Date
29 Sept 2022, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
SPECIAL REPAIR FOR FIRE AND FURY OFFRS MESS COOK HOUSE KITCHEN WASHING AREA AT 14 COSR CONSTN OF ONE SOAKAGE WELL AT 57 ENGR REGT PROVN OF 01 X WASH ROOM AT 14 CESR AND PROVN OF LT PANEL AT SUB AREA OFFRS MESS UNDER GE 865 EWS
2022_MES_545396_2
865/EWS(NIT-73)/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹95,600
Yes
7 Nov 2022
7 Sept 2022
1 Oct 2022
7 Sept 2022
29 Sept 2022
15 Sept 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for (350mmx250mmx7mm/450mmx350mmx 7mm thick) coloured glazed ceramic tiles set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments.(Note: Any disturbed surfaces shall be matched w/o any extra cost to the govt) incl 10mm thckbacking coat for dado/skirting CM 1:4 complete all as specified and directed by Engr-in-Charge. Make : As per PS.
Demolition of cement concrete (unreinforced) as in ground floor of any description and in any position not other wise specifically provided for and Removing demolished material to a distance and depositing out site of MoD land Where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick PCC 1:2:4, type B-0 using 12.5mm graded crushed stone aggregate as in sub base/ levelling course for laying of screed bed complete all as specified by Engr-in-Charge.
M&L for 10 mm thick Vitrified tiles light shade as in floors in size of 600x600 mm set and jointed with neat cement slurry and pointed with coloured cement and incl 15 mm thick screed bed or bedding layer of cement mortar 1:6 to match the shade, pattern, laying etc of tiles complete all as specified and directed by Engr-in-Charge. Make as per PS.
M & L for joint free Non-Skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm not exceeding 0..11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:6 for laying floor finishes complete all as specified and directed by Engr-in-Charge.
M & L for joint free Non-Skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm not exceeding 0..36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:6 for laying floor finishes complete all as specified and directed by Engr-in-Charge.
M&L Machine cut pre polished Kota stone slab flooring 20-25 mm thick over 20mm thick cement screed bed or bedding layer in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillers, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement 1:2) using marble dust with admixture of pigment to match with the shade of granite over 15 mm thicm screed bed in CM 1:4, including rounding and moulding wherever required edges of granite as directed complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection and finished concrete surface even and smooth without using extra cement including making proper joints with bitumen mastic with sand as per specification at an interval of 3m and change of direction complete all as specified and as directed by Engr-in-Charge.
M&L for wooden floor laminated type tiles 7 mm thick with dove tailed joints over 150 micron polythene film and 3 mm thick form as per manufacture instructions, including taking down of old wooden flooring of any description complete all as specified and directed by Engr-in-Charge. Make As per PS.
M & L for providing and fixing Gypsum boards 8 to 9 mm thick in ceilings fixed with screws as per manufacturers instructions including anodised aluminium snap grid frame work of size 605 x 605 mm with anodised aluminium channel supports/ angles/ 'T' (Main tee 35 x 25 x 1.5 mm, cross tee 25 x 25 x 1.4 mm and wall angle 32 x 32 x 2 mm) fixed with screws/ plugs etc including GI suspenders of 6mm dia upto 1200 mm length adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size as per approved pattern and design including taking down of existing ceiling at any description complete all as specified and directed by Engr-in-Charge. Make : As per PS.
S&F wooden wall panelling on vertical surfaces of wall using specification as follows:- (i) S&F 2 nd class hard wood wooden gutties of size 25mmx25mmx200mm depth fixed in wall by making holes in brick wall and making good surfaces in CM 1:3. (ii) S&F horizontal runner 2 nd class hardwood @ 1.20 mtr C/C of cross sectional area exc 13 Sqcm and not exc 25 sqcm clean swan treated with two coat of tar or coal tar black paint and also treated with chlorophyroposis. (iii) S&F first class wood (Deodar/teak) boarding 12 to 15 mm thick as in wall panelling planed clean swan and grooved at edges, one side wrought other side and applying tow coat of good quality polishing glossy finished and back side applying antitermite treatment with chlorophyroposis complete fixed with screws on wooden runners. (iv) S&F first class teak wood decorative type beading 40 mm wide suitable for on top, bottom and edges wall or window/door jam/cills complete with polished and match with wooden wall panelling (v) Taking down of existing wall panelling with any type of frame work complete all as specified and directed by Engr-in-Charge.
S&F for 6mm thick Veneered decorative ply wood, grade-1 with BWP and decorative face veneers fixed with screws to timber frame work, including taking down existing boarding of any description complete all as specified and as directed by Engr-in-Charge. Make : As per PS.
M&L for 9 mm thick prelaminated particle board, medium interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, includign taking down boarding of any description complete all as specified and as directed by Engr-in-Charge. Make : As per PS.
M&L for second class soft wood clean swan as in beading for edges of ceiling, lining, wooden flooring work, plain fillets exc 13 sqcm and n.exc 25 sqcm, square/ rectangular in section , secured with nails or brads to timber frame work including taking down complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Taking down of shutter of any description exc 1 Sqm and not exc 2 Sqm and refixing the same opening after rectified the defectes complete all as specified and directed by Engr-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium fittings such as handles - 02 Nos, hinges - 03 Nos, sliding bolt - 01 Nos, tower bolt - 02 Nos in each door, powder coated aluminium snap beading, screws etc complete all as specified and directed by Engr-in-Charge
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long - 01 Nos, telescopic hinges 100mm long - 02 Nos, suitable handle - 01 Nos etc in each shutter complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by Engr-in-Charge.
S&F Floor door stopper 150 mm long of aluminium alloy body and tounge, anodised, with hard drawn steel spring, complete all as specifeid and directed by Engr-in-Charge.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed by Engr-in-Charge.
S&F mild steel mortice lock, 4 levers, vertical type mild steel size 100 mm complete all as specified and directed by Engr-in-Charge.
M&L for 4 mm thick figured glass or frosted/pinhead glass type fixed with oil putty or aluminium beads or fixed to steel etc complete all as specified and directe by Engr-in-Charge
S&F Aluminium door closer hydraulically regulated designation No 3 , universal type, suitable for door shrtters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed compelte all as specified and directed by Engr-in-Charge. Make : As per PS.
Demolition of precast concrete block/Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:6 all as Specified by Engr-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick rendering in cement mortar 1:4 other than fair faces of brick walls or on concrete surfaces with water proofing compound @3% weight of cement finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge. Note : WPC shall be measured and paid separately
Supply only intergral waterproofing compound complete all as specified and directed by Engr-in-Charge. Make: As per PS
M&L for rendering 10 mm thick rendering in cement mortar 1:4 on fair faces of brick walls or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plastered/concrete surfaces of wall and applying 3 mm thick JK / Birla wall putty in two layer as per manufactures instructions, surfaces to be finished even and smooth over a coat of alkali resisstane primer and applying two coats of oil emulsion distember first quality of approved colour complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered/concrete surfaces of wall to be finished even and smooth and a coat of alkali resisstane primer and applying two coats of oil emulsion distember first quality of approved colour complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatment on walls of any description and preparation of old surfaces of wall washing rubbing down and applying two coats of weather coat paint over a coat of primer over applying exterior grade wall care puttyand surface shall be smooth complete all as specified and directed by Engr-in-Charge. Make : As per PS.
M&L for prepartion of newly plastered surfaces of walls and applying two coats of weather coat paint over a coat of primer over applying exterior grade wall care putty and surface shall be smooth etc complete all as specified and directed by Engr-in-Charge. Make : As per PS.
S&F in19mm dia mild steel, chromium plated curtain rods, with brackets, end bulbs all as specified and as directed by Engr-in-Charge.
S&F 0.63 mm thick corrugated galvanised mild steel sheets over lap with two corrugation side lap fixed with 'J' or 'L' hooks with grade of zinc coating 275 incuidng taking down existing sheeting of any guage or thickness at any description complete all as specified and directed by Engr-in-Charge. Make : As per PS.
Taking down and refixing of galvanised mild steel sheets after cleaning same location or adjacent area fixed with 'J' or 'L' hooks of any desciption complete all as specified and directed by Engr-in-Charge.
S&F 0.63 mm thick plain galvanised mild steel sheets fixed with 'J' or 'L' hooks with grade of zinc coating 275, incuidng taking down existing sheeting of any guage or thickness at any description complete all as specified and directed by Engr-in-Charge. Make : As per PS.
M&L for two coats of synthetic enemal paint on new or previous untreated corrugated steel steel surfaces including preparation over a coat of red oxide primer with modrant solution complete all as specified and direceted by Engr-in-Charge.
M&L for one coat of synthetic enemal paint on old or previous untreated corrugated steel steel surfaces complete all as specified and direceted by Engr-in-Charge.
Hacking out old broken glass of any thickness size, quality, description) from wooden or steel frames fixed with oil putty or wooden beads complete all as specified and directed by Engr-in-Charge.
M&L for one coat of synthetic enemal paint on old decorated wooden surfaces complete all as specified and direceted by Engr-in-Charge.
S&F 3 mm thick sheet glass any size ordinary quality in steel or wooden frames not exc 5 sqm complete with fixing material such as putty glazing pins wooden beads etc complete all as specified and directed by Engr-in-Charge.
Excavating in trenches, n. exc 1.5 m wide and n exc 1.5 m deep, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan in hard/dense soil and getting out soil, complete all as specified and as directed by Engineer-in-charge.
Excavating in trenches, n. exc 1.5 m wide and exc 1.5 m deep and not exc 3.00 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan in hard/dense soil and getting out soil, complete all as specified and as directed by Engineer-in-charge.
Excavating over areas, n exc 1.5 m deep and getting out hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavating over areas, exc 1.50 but n exc 3 m deep and getting out hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavating over areas, exc 3 but n exc 4.50 m deep and getting out hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and as directed by Engineer-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and as directed by Engineer-in-Charge.
M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in sub base, foundation, filling and mass concrete, complete all as specified and as directed by Engineer-in-Charge.
M&L for providing precast reinforced cement concrete type B1, 1:2:4 using 20mm graded aggregate as in landings, cover slabs (for man holes etc) and similar articles with plain faces and setting in cement mortar 1:6 complete with joints to match including use of necessary formwork all as specified and directed. Note : S&F reinforcement shall be measured and paid separately.
S&F mild steel TMT bars of 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips , complete all as specified and directed by Engr-in-Charge.
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 for using 300 mm bore pipes complete all as specified and directed by Engr-in-Charge.
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 for using 110 mm bore pipes complete all as specified and directed by Engr-in-Charge.
S&F 300 mm diabore inner dia double wall corrugated HDPE pipe (SN-8) in any length including all fitting and jointing with rubber link and cupler / other jointing material laid in trenches or in floors all as specified and directed by Engr-in-Charge.
S&F for 1:2:4 B-1 (using 20 mm graded stone aggregate) cement concrete in surface channels and drains complete all as specified and directed by Engr-in-Charge.
Supply only Liquid water proofing compound complete all as specified and directed by Engr-in-Charge. Make as per PS
M&L for 110 mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, fixed to walls, laid in trenches or in floors complete all as specified and as directed by Engr-in- Charge.Make as per PS.
S&F PVC (SWR) bents 110 mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) 'T'(tee) 110 mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed by Engr-in-Charge.
M&L for Preparation of old treated plastered / unplastered surfaces of walls and applying two coats of cement base paints of any shade on walls (shade as approved by users) including curing before and after applying each coat complete all as specified and directed by Engineer-in-Charge. Make as per PS.
M&L for rendering 15 mm thick rendering in cement mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
S&F Mild steel work as in angles or tees, fixed independently or cut to shape drilled incl bending and welding angles of grade 410- Fe complete all as specified and directed by Engr-in-Charge
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheets 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering to wall fixed self tapping screws complete all as specified and directed by Engr-in-Charge. Make as per PS.
M&L for hard core of broken stone or boulders of gauge n.exc 63 mm deposited, spread and level in layers n. exc. 15 cm thick watered and rammed to true surface complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm thick PCC 1:2:4 type B-1 using 40 mm graded stone aggregate as infloor complete all as specified and directed by Engr-in-Charge.
S&F 25mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified. Make : As per PS.
S&F 32mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified. Make : As per PS.
S&F PP-R 32 mm bore gate valve complete all as specified and directed by Engr-in-Charge. Make as per PS.
S&F 15 mm bore Bip tap long body with wall flange fancy type chromimum plated brass screwed for iron pipe with capstain head complete all as specified and directed by Engr-in-Charge. Make: as per PS.
S&F 15 mm bore stop valve, fancy type, chromimum plated brass screwed for iron pipe with capstain head complete all as specified and directed by Engr-in-Charge. Make: as per PS.
S&F chromimium plated showe rose 125 mm size with or without swivel joint, including fixing to steel pipes or unions complete all as specified and directed by Engr-in-Charge.
S&F Grating doom 100 mm dia of CP complete all as specified and directed by Engr-in-Charge.
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm, long complete all as specified and diected by Engr-in-Charge. Make: Prayag/Polytuf/Supreme
S&F Towel rail 600 mm long Aluminium chromimum plated (Silver) fixed to wall with stainless screws with fisher complete all as specified and directed by Engr-in-Charge. Note : Make as per PS.
S&F PVC valve less, syphonic action type, white low level fluhing cistern of capacity 10 ltr with inlet ball valve and float and handle including brackets and bend 32 mm bore PVC complete fixed to wall complete all as specified and directed by Engr-in-Charge. Make as per PS.
S&F Vitreous china water closet, 'Orissa' pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, incl bedding with PCC 1:2:4 type B-1 using 20 mm grade stone aggregate complete all as specified and as directed by Engr-in-Charge. Make as per PS.
S&F Viterous china wash basin, white flat back size 580x 450mm including waste coupling CP 32mm dia and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes fixed complete, all as specified and as directed by Engr-in-Charge. Make as per PS.
S&F in repair PVC 32 mm dia waste pipes fixed to wash hand basin, urinals, sink etc complete all as specified and directed by Engr-in-Charge.
S&F in repair 15mm bore, piller tap chromimum plated fancy type high pressure with or without letter Hot or cold with long screwed shank and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. Make as per PS.
M&L for 2nd class hard wood as in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed by Engr-in-charge.
S&F 30 mmt thick Flush shutter solid core construction, with block board core and ply wood face pane,, commertial type on both sides complete all as specifeid and directed by Engr-in-Charge.
S&F 30mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge. Make as per PS.
M&L for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate, as in hold fast, bed blocks and the like complete all as specified and as directed by Engr-in-Charge.
S&F aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
M&L for Preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed by Engineer-in-Charge.Make as per PS.
M&L for framed work such as grills, greatings, etc with end of bars shouldered and or revited or forged into spikes framed guard bars barred iron doors ladders, framed balusters walk ways, railing, frame work of water tanks and similar work confirming to Fe-290, Gde E-165 complete all as specified and directed by Engr-in-Charge.
S&F for 300mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed by Engr-in-Charge.
S&F for Aluminium, anodized, barrel tower bolts, ISI Marked, of extruded section 200 mm long, complete all as specified and directed by Engr-in-Charge.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed by Engr-in-Charge.
S&F for Butt hinges, medium weight, cold rolled mild steel and fixed with screws to wooden frames or with welding to existing MS frames,100 mm size, ISI marked, complete all as specified and directed by Engineer-in- Charge.
S&F in PVC (SWR) gully trap 125/110 mm setting with solvent cement complete all as specified and directed by Engr-in-Charge.
S&F 75 mm PVC nahani trap, setting and jointing with solvent cement and fixed in cement concrete type B-1 1:2:4 complete all as specified and directed by Engr-in-Charge.
S&F Rotational moulded polyethylene water storage tank, inner and out white, two layers, ISI marked (cylinderical vertical with closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, complete all as specified and as directed by Engr-in-Charge.
S&F 25 mm bore ball brass valve high pressure with polythene float and fly nuts complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/Aluminum point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc complete all as speciifed and directed.
M&L for point wiring for one light point or fan point controlled by one light/exhaust fan controlled by one way switch with PVC insulated copper conductor stranded cable of size 1.5 sqmm and including PVC casing/caping terminated in existing sunk CI/pressed steel terminal boxes for fixing and 1.5 sqmm PVC insulated copper wire as earth wire connected to earth wire connected to earth folly and 3.0mm thick plastic laminated sheet cover all as specified and directed by Engr-in-Charge.
All as per item No 104 here-in-before but 1.5 Sqmm for one 3 pin 6 amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the same board complete all as specified and directed by Engr-in-Charge.
All as per item No 104 here-in-before but 1.5 Sqmm for one 3 pin 6 amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per item No 104 here-in-before but for power point 3 pin switch socket 15 Amp with PVC copper conductor cable multistrand unsheathed 2.50 Sqmm on independent board incl one run 1.50 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and capping fixed on wall incl PCV box and 3mm thick of hylam top sheet complete all as specified and as directed by Engr-in-Charge
S&F in replacement of socket 3 pin, 5/6 Amps flush type universal complete all as specified and directed by Engr-in-Charge
S&F in socket 3 pin, 5/6 Amps flush type universal complete all as specified and directed by Engr-in-Charge
S&F in replacement of socket 5 pin,16 Amps flush type universal complete all as specified and directed by Engr-in-Charge
S&F in socket 5 pin,16 Amps flush type universal complete all as specified and directed by Engr-in-Charge
S&F in replacement of decorative ultra slim square profile linear LED lighting fixures with extruded polycorbonate, environmental frendly energy efficent ready to use pack of delite LED of capacity 18 W LED 6500K, 4 feet long (white colour') having driver connector block etc complete with all acessories prewired and connecting electrically to ceiling rose using PVC insulated end over all sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as specified and directed by Engr-in-Charge. Make as per PS.
S&F in decorative ultra slim square profile linear LED lighting fixures with extruded polycorbonate, environmental frendly energy efficent ready to use pack of delite LED of capacity 20 W LED 6500K, 4 feet long (white colour') having driver connector block etc complete with all acessories prewired and connecting electrically to ceiling rose using PVC insulated end over all sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as specified and directed by Engr-in-Charge. Make as per PS.
S&F in replacement of LED lamp 7 watt, 230 volts, 50 Hz, AC complete all as specified and directed by Engr-in-Charge
S&F in LED lamp 10watt, 230 volts, 50 Hz, AC complete all as specified and directed by Engr-in-Charge
S&F in repalcement of 2' x2' Recess mounting LED ceiling panels white LED luminares white powder coated sheet housing LED seamkess front frame with white coloured falt acrylic with celing layout of capacity 36 Watt LED extruded aluminum heat sink including driver projected in false ceiling complete all as specified and directed by Engr - in -charge. Make as per PS.
S&F for Switch piano flush button single pole 6 Amps 230 volt one way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and directed by Engr-in-charge.
S&F in ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and directed by Engr-in-charge.
M&L for repalcement of lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings as specified and directed by Engr-in-Charge.
M&L for lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings as specified and directed by Engr-in-Charge.
S&F in replacement of any size and provide new sheet metal distribution board iron clad VTPN, double door with acrylic door IP-43, IK-09, 12 ways, protection suitable or MCCB as incormer and MCB as outgoing 415 Volts, 3 phase 50 Hz, complete with appropriate size copper Bus bar and neutral link confirming complete with one MCCB 4 pole 415 Volts 160 Amps rating, thermal magnetic with rupturing cap 25 KA of the same make as of distribution wall surface all as reqd site including testing complete all as specified and as directed by Engr-in-Charge. Make as per PS.
S&F in replacement of Sheet mental enclosure SPN for DBs with 200 Amps bus bar of 12 way 240 volts with blank plate double door all as specified abd directed by Engr-in-Charge. Make as per PS.
S&F in replacement of Sheet mental enclosure SPN for DBs with 200 Amps bus bar of 4 way 240 volts with blank plate double door all as specified abd directed by Engr-in-Charge. Make as per PS.
S&F in replacement of MCB single phase (SP), 6 to 32 Amps Volts 'C' Curve complete all as specified and directed by Engr-in-Charge.
S&F in MCB single phase (SP), 6 to 32 Amps Volts 'C' Curve complete all as specified and directed by Engr-in-Charge.
S&F MCB DP C- curve, 230 volt 32 Amp complete all as specified and directed by Engr-in-Charge.
S&F MCB SPN, C- Curve, 230 Volt 63 Amps, 10 KA complete all as specified and directed by Engr-in-Charge.
S&F MCB TPN, C-Curve, 230 Volt, 63 Amps, 10 KA complete all as specified and directed by Engr-in-Charge.
M&L for in repalcement of Sub main wiring with two run of 6.00 Sqmm (2x6 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6.00 Sqmm (1x6sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm), one run of 6 Sqmm (1x6 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: As per PS.
M&L for Sub main wiring with two run of 6.00 Sqmm (2x6 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6.00 Sqmm (1x6sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm), one run of 6 Sqmm (1x6 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: As per PS.
M&L for point wiring complete with 2 x 4.00 sqmm nominal area of copper conductor multi stranded FRLS PVC insulated and unsheathed 1100 volts cable drawn through and including PVC conduit with standard acessories such as elbows, tees, junctions etc and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 2.5 Sqmm copper conductor cable as continous earth lead all as specified and directed.
M&L for in replacement of Sub main wiring with two run of 2.50 Sqmm (2x2.50 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of2.50 Sqmm (1x2.50sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 2.50 Sqmm (2x2.50sqmm), one run of 2.5 Sqmm (1x2.5 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: As per PS.
Material and labour for in replacement of earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point, etc, incluidng taking down of old u/s earthing set complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order ( For Main DBs ) (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
Supply and laying, in replacement of jointing and testing LT under ground cable heavy duty 1100 Volts grade PVC insulated steel wire or tape armoured overall PVC sheatheled of size 35 Sqmm 3.5 core laid in trenches/pole/loop including brass terminal lugs etc complete all as specified and directed by Engr-in-Charge. Make as per PS.
Supply and laying, in replacement of jointing and testing LT under ground cable heavy duty 1100 Volts grade PVC insulated steel wire or tape armoured overall PVC sheatheled of size 16 Sqmm insulating hangers not more than 1 metre apart incluidng 4 sqmm suspended wire tow single conductor cable flat or circulator complete all as specified and directed by Engr-in-Charge. Make as per PS.
Sand cushining for cables 8 cm below the cable 15 cm above the cable compelte all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of un-reinforced precast concrete cover LV type-I flat size 250 x 150x 40 mm complete all as specified and directed by Engr-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engr-in-Charge.
S&F heating element suitable for water storage heater vertical type 220/240V AC, 2000 watts and making connections and testing complete all as specified and directed by Engr-in-Charge.
Supply and laying jointing and testing PVC insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 25 Sqmm 4 Core. Make as per PS.
Supply and laying jointing and testing PVC insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 35 Sqmm 3.5 Core. Make as per PS.
Supply and laying jointing and testing PVC insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 50 Sqmm 3.5 Core. Make as per PS.
Supply and laying jointing and testing PVC insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 70 Sqmm 3.5 Core. Make as per PS.
Supply and laying jointing and testing PVC insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 95 Sqmm 3.5 Core. Make as per PS.
Supply and fixing of exhaust fan, plastic body, AC single phase 230 volts of size 250 mm sweep with blades and frame and louvers complete all as specified and as directed.
M/S LEO TRADERS
M.S Sharma Enterprises
M/S SHAMSHER ALI SUFI
Rampal Singh Contractor
Mehar Enterprises
M/S LIBE & CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .