| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.7 L+₹40,647 (5.59%)Rejected-AOC 7TH MILE P O NONGLYER UPPER SHILLONG 793002 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793002 | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹7.8 L+₹50,920 (7.00%)Rejected-AOC PINE DALE PINE MOUNT RIDGE SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | L3 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
26 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I)(AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA No GE (I) (AF) /SHL/ OF 2022-2023 REPAIR/MAINTENANCE OF SPLIT ACS AND COOLING APPLIANCES WITH ALLIED WORKS AT HQ EAC (U) UNDER GE (I) AF SHILLONG
2022_MES_517241_3
8015/22/SHL/2022/23
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
SHILLONG
For Enlisted Contractors Class E Category b i/c Iand for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE(I)(AF) SHILLONG
₹16,000
Yes
5 Sept 2022
30 Jun 2022
28 Jul 2022
30 Jun 2022
26 Jul 2022
7 Jul 2022
30 Jun 2022 - 4 Jul 2022
Amount
Disconnecting electrical connections of Split type Air Conditioners, storing refrigerant gas in compressor of outdoor unit, splitting indoor and outdoor units, checking for faults and worn out parts/components, removing all accumulated dust and dirt of indoor and outdoor units, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling indoor and outdoor units, re-installing both indoor and outdoor units at respective locations (old or new locations as directed), re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required or connecting with service valves in outdoor unit and in indoor unit with threaded cast copper alloy sockets , making electrical connections, testing and commissioning complete all as directed for the following capacity Air Conditioners :-
Split type Airconditioner 1.5 TR capacity of any make
Split type Airconditioner 2.0 TR capacity of any make {Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, felts, lead metal balancing of blower fans, lugs, thimbles, sockets and other minor materials shall be deemed to be inclusive in quoted rate. (b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against these items}
Disconnecting electrical connections of refrigerators, storing refrigerant gas in compressor, checking for faults and worn out parts/components, removing all accumulated dust and dirt, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling refrigerators, re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required, making electrical connections, testing and commissioning complete all as directed for the following capacity Refrigerators :-
Refrigerators of 165 Litre to 255 Litre capacity of any make {Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, lugs, thimbles other minor materials shall be deemed to be inclusive in quoted rate. (b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against this item}
Repair/maint of Deep freezers including disconnecting electrical connections, checking for faults and worn out parts/components, removing all accumulated dust and dirt, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassemblingdeep freezer, re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required or connecting with service valves with threaded cast copper alloy sockets , making electrical connections, testing and commissioning complete all as directed for the following capacity Deep Freezers :-
Deep Frezer of 200 to 500 Litre capacity of any make {Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, felts, lugs, thimbles, sockets and other minor materials shall be deemed to be inclusive in quoted rate. (b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against these items}
Supply only following spare parts/components of ACs, Refrigerators, refrigerant Gas for all these equipments/appliances complete all as directed :- {Notes : (a) Genuine spare parts/components and refrigerant gas as originally fitted/filled in ACs, Deep freezers, Refrigerators, Package type AC Units shall only be provided during repairs/replacement. (b) These genuine spare parts/components and refrigerant gas shall be procured through OEM/their authorised distributers or dealers/service frenchise/service stations (Authosised to deal in genuine spare parts/components)
Control circuit (PCB) for 1.5 TR capacity Split/Tower type AC, operating on 50 Hz electric supply of current rating, humidity control rating, operating temperature range and impedence as per Technical parameter of existing PCB installed by OEM in AC.
Control circuit (PCB) for 2.0 TR capacity Split/Tower type AC, operating on 50 Hz electric supply of current rating, humidity control rating, operating temperature range and impedence as per Technical parameter of existing PCB installed by OEM in AC.
Remote circuit unit with remote controller cord, nylon fastner, tapping screw for 1.5 TR capacity Split/Tower AC as per Technical parameter of existing Remote circuit unit installed by OEM in AC.
Remote circuit unit with remote controller cord, nylon fastner, tapping screw for 2.0 TR capacity Split/Tower AC as per Technical parameter of existing Remote circuit unit installed by OEM in AC.
Copper tube of size 3/8 inch outer dia, 0.8mm thick ISI marked for Air conditioners.
Copper tube of size 5/8 inch outer dia, 1.0mm thick ISI marked for Air conditioners.
Standard strainer & capillary tube of compressor for 1.5 TR Split/Tower type A/C as per Technical parameter of existing strainer & capillary tube installed by OEM in AC.
Standard strainer & capillary tube of compressor for 2.0 TR Split/Tower type A/C as per Technical parameter of existing strainer & capillary tube installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 1.5 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 2.0 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 200 Ltr capacity deep freezer as per Technical parameter of existing compressor installed by OEM in Deep freezer.
Hermatically sealed, uncut rotary type compressor for 400/500 Ltr capacity deep freezer as per Technical parameter of existing compressor installed by OEM in Deep freezer.
Hermatically sealed, uncut rotary type compressor for 255 Ltr capacity refrigerator as per Technical parameter of existing compressor installed by OEM in refrigerator
Referigent gas R-22.
Referigent gas R-32.
Referigent gas R-134a.
LCD/LED display unit for Split type AC of 1.5 TR/2.0 TR capacity.
Air equalizer for Split type AC of 1.5 TR/2.0 TR capacity.
Swing motor of indoor unit of Split type AC 1.5 to 2 TR capacity as per Technical parameter of existing motor installed by OEM in ACs.
Indoor fan motor of Split type AC 1.5 to 2 TR capacity as per Technical parameter of existing motor installed by OEM in ACs.
Supply only Indoor fan motor capacitor for split AC 1.5/2 TR capacity.
Outdoor fan motor for 1.5 to 2.0 TR Capacity Split type AC as per Technical parameter of existing outdoor fan motor installed by OEM in ACs.
Outdoor fan Blade for 2.0 TR Capacity Split type AC as per Technical parameter of existing fan blades installed by OEM in ACs.
Service Valve suitable for 5/8 inch outer dia copper tubing.
Service Valve suitable for 1/2 inch outer dia copper tubing.
Service Valve suitable for 3/8 inch outer dia copper tubing.
Service Valve suitable for 1/4 inch outer dia copper tubing.
Condensor Coil for outdoor unit of split AC 1.5 TR capacity as per Technical parameter of existing Condensor Coil installed by OEM in ACs. .
Condensor Coil for outdoor unit of split AC 2.0 TR capacity as per Technical parameter of existing Condensor Coil installed by OEM in ACs. .
Overload protection relay for deep freezer of capacity 200 Ltr as per Technical parameter of relay installed by OEM in deep freezer .
Overload protection relay for deep freezer of capacity 400/500 Ltr as per Technical parameter of relay installed by OEM in deep freezer .
Cooling fan unit for deep freezer of capacity 200 Ltr as per Technical parameter of cooling fan unit installed by OEM in deep freezer.
Cooling fan unit for deep freezer of capacity 400/500 Ltr as per Technical parameter of cooling fan unit installed by OEM in deep freezer.
Bimetal Thermostate for referigerator for norfrost system of reputed make.
Thermal fuse for refrigerator for norfrost system
Timer for refrigerator for norfrost system
S & F in repairs Thermostate switch for referigerator 165 to 255 ltrs capacity of reputed make.
S & F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SP 20 Amps, complete all as specified and directed.
S & F in repairs Compressor starting relay for refrigerators of any capacity.
Taking out old unserviceable PVC insulated & PVC Round Sheathed 2 core 2.5 Sqmm cable from any situation and Supply and fix/lay PVC insulated and FRLS PVC Round Sheathed, 2 core 2.5 Sqmm cable Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 for passing through conduit/through floor or through false ceiling complete all as specified and directed.
Taking out old unserviceable PVC insulated & PVC Round Sheathed 2 core 4.0 Sqmm cable from any situation and Supply and fix/lay PVC insulated and FRLS PVC Round Sheathed, 2 core 4.0 Sqmm cable Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 for passing through conduit/through floor or through false ceiling complete all as specified and directed.
madan enterprise
M/s A L Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .