| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.7 L+₹25,602 (1.47%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.9 L+₹2.5 L (14.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹20.8 L+₹3.4 L (19.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹23.3 L+₹5.9 L (33.8%)Rejected-Finance R S PURA NEW PLOT SALEHAR R S PURA JAMMU JAMMU JAMMU KASHMIR 181111 | JAMMU | JAMMU AND KASHMIR | 181111 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Hi Tech Engineers L3 | LAL CONSTRUCTIONS L2 | BMMJ TRADERS AND ENGINEERS L1 | ASHOKKUMAR SURI L6 | Durga Electricals L4 | HARSH ELECTRICAL STORE L5 | M/S RAJ ENGINEERS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Note :- 1. The work is meant for day to day maintenance based on complaints . The complaints are required to be attended / cleared on the same day of the reporting. However in exceptional case, if any complaint could not be attended on the same day,the same will be cleared within 48 hours of the reporting. If contractor fails to attend / clear the complaint within 48 hours, a penalty of Rs. 100/- per complaint per day will be imposed till the completion of complaint and recovery amount will be deducted from the RAR submitted by contractor.The T&P required shall be arranged by the contractor. 2. The contractor shall be provided with space for setting up maintenance cell at the specified location as per the directions of Engineer-in-Charge.The maintenance cell shall be manned by the contractor's supervisor responsible for collecting complaints from the concerned JE/AGE. A proper record of complaints will be maintained by the concerned JE duly signed by contractor. 3. The quoted rate of minor material like screws,nuts, insulating tape ,copper wire of different sizes upto 01 meter length required in the items of BoQ is deemed to be included in the respective item. | ||||||||||
| 2.00 | S&F in replacement switch piano, flush type, single pole, one way, 6 Amps, 240 V as per existing make complete all as specified and directed | 1,000 | Each | 18 ₹18,000 | 12 ₹12,000 Lowest | 14 ₹14,000 | 25 ₹25,000 | 15 ₹15,000 | 20 ₹20,000 | 20 ₹20,000 |
| 3.00 | S&F in replacement bell push, flush type, 6 Amps, 240 V as per existing make complete all as specified and directed | 50 | Each | 25 ₹1,250 | 15 ₹750 Lowest | 15 ₹750 Lowest | 25 ₹1,250 | 50 ₹2,500 | 25 ₹1,250 | 70 ₹3,500 |
| 4.00 | S&F in replacement buzzer ding dong, 240 V as per existing make complete all as specified and directed | 250 | Each | 140 ₹35,000 | 75 ₹18,750 | 50 ₹12,500 Lowest | 100 ₹25,000 | 60 ₹15,000 | 100 ₹25,000 | 300 ₹75,000 |
| 5.00 | S&F in replacement socket outlet, two-in-one, 3 pin, 6 Amp, flush type,230 volts, AC supply as per existing make complete all as specified and directed | 800 | Each | 40 ₹32,000 | 28 ₹22,400 | 20 ₹16,000 Lowest | 50 ₹40,000 | 30 ₹24,000 | 35 ₹28,000 | 30 ₹24,000 |
| 6.00 | S&F in replacement switch socket combination, two-in-one, 3 pin, 6 Amp, flush type,230 volts, AC supply as per existing make complete all as specified and directed | 100 | Each | 80 ₹8,000 | 34 ₹3,400 Lowest | 80 ₹8,000 | 70 ₹7,000 | 55 ₹5,500 | 65 ₹6,500 | 60 ₹6,000 |
| 7.00 | S&F in replacement switch piano, flush type, single pole, one way, 16 Amps, 240 V as per existing make complete all as specified and directed | 500 | Each | 60 ₹30,000 | 45 ₹22,500 | 40 ₹20,000 Lowest | 70 ₹35,000 | 45 ₹22,500 | 55 ₹27,500 | 55 ₹27,500 |
| 8.00 | S&F in replacement socket outlet, two-in-one, 3 pin, 6 & 16 Amp, flush type,230 volts, AC supply as per existing make complete all as specified and directed | 500 | Each | 60 ₹30,000 | 55 ₹27,500 | 40 ₹20,000 Lowest | 90 ₹45,000 | 45 ₹22,500 | 55 ₹27,500 | 60 ₹30,000 |
| 9.00 | S&F in replacement switch socket combination, two-in-one, 3 pin, 6 & 16 Amp, flush type,230 volts, AC supply as per existing make complete all as specified and directed | 100 | Each | 120 ₹12,000 | 65 ₹6,500 Lowest | 80 ₹8,000 | 150 ₹15,000 | 80 ₹8,000 | 100 ₹10,000 | 90 ₹9,000 |
| 10.00 | S&F in replacement stepped type electronic fan regulator, flush type,single phase, AC supply, 230 V as per existing make complete all as specified and directed | 300 | Each | 130 ₹39,000 | 120 ₹36,000 | 90 ₹27,000 Lowest | 150 ₹45,000 | 100 ₹30,000 | 150 ₹45,000 | 150 ₹45,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Aug 2025, 6:00 pmClosed
GE SATWARI
GE SATWARI
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION,CEILING FANS,EXHAUST FANS,RE-WIRING AND ALLIED WORKS OF ORS MD ACCN AND OTM ACCN AT Y STATION , RIDGE AREA AND DEFENCE COLONY UNDER AGE E/M OF GE SATWARI
2025_MES_723883_1
GEJM-34/2025-26
Open Tender
Electrical and Maintenance Works
Works
270 days
GE SATWARI
Class D Cat b (i)
9 documents required · 9 mandatory
₹500
Yes
GE SATWARI
₹80,000
Yes
25 Sept 2025
1 Aug 2025
1 Sept 2025
1 Aug 2025
30 Aug 2025
16 Aug 2025
Amount
Note :- 1. The work is meant for day to day maintenance based on complaints . The complaints are required to be attended / cleared on the same day of the reporting. However in exceptional case, if any complaint could not be attended on the same day,the same will be cleared within 48 hours of the reporting. If contractor fails to attend / clear the complaint within 48 hours, a penalty of Rs. 100/- per complaint per day will be imposed till the completion of complaint and recovery amount will be deducted from the RAR submitted by contractor.The T&P required shall be arranged by the contractor. 2. The contractor shall be provided with space for setting up maintenance cell at the specified location as per the directions of Engineer-in-Charge.The maintenance cell shall be manned by the contractor's supervisor responsible for collecting complaints from the concerned JE/AGE. A proper record of complaints will be maintained by the concerned JE duly signed by contractor. 3. The quoted rate of minor material like screws,nuts, insulating tape ,copper wire of different sizes upto 01 meter length required in the items of BoQ is deemed to be included in the respective item.
S&F in replacement switch piano, flush type, single pole, one way, 6 Amps, 240 V as per existing make complete all as specified and directed
S&F in replacement bell push, flush type, 6 Amps, 240 V as per existing make complete all as specified and directed
S&F in replacement buzzer ding dong, 240 V as per existing make complete all as specified and directed
S&F in replacement socket outlet, two-in-one, 3 pin, 6 Amp, flush type,230 volts, AC supply as per existing make complete all as specified and directed
S&F in replacement switch socket combination, two-in-one, 3 pin, 6 Amp, flush type,230 volts, AC supply as per existing make complete all as specified and directed
S&F in replacement switch piano, flush type, single pole, one way, 16 Amps, 240 V as per existing make complete all as specified and directed
S&F in replacement socket outlet, two-in-one, 3 pin, 6 & 16 Amp, flush type,230 volts, AC supply as per existing make complete all as specified and directed
S&F in replacement switch socket combination, two-in-one, 3 pin, 6 & 16 Amp, flush type,230 volts, AC supply as per existing make complete all as specified and directed
S&F in replacement stepped type electronic fan regulator, flush type,single phase, AC supply, 230 V as per existing make complete all as specified and directed
S&F in replacement modular type switch, one way, 6 Amps ,1 module as per existing make complete all as specified and directed
S&F in replacement modular type socket,6 Amps, 2/3 pin combined 2 module as per existing make complete all as specified and directed
S&F in replacement modular type socket,6A/16 Amps, 2/3 pin combined 2 module as per existing make complete all as specified and directed
S&F in replacement modular type switch, one way ,16 Amps ,1 module as per existing make complete all as specified and directed
S&F in replacement PVC plug top, 6 Amp,3 pin with easy grip, white, matt finish complete all as specifed and directed.
S&F in replacement PVC plug top, 15/16 Amp,3 pin with easy grip, white, matt finish complete all as specifed and directed.
S&F in replacement mettalic plug top, 16 Amp,3 pin with easy grip, white, matt finish complete all as specifed and directed.
S&F in replacement fan capacitor 2.15 mfd to 2.5 mfd complete all as specifed and directed.
M&L in replacement modular sheet cover plate with frame of size 8-12 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement modular sheet cover plate with frame of size 6 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement modular sheet cover plate with frame of size 3 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement GI/pressed steel terminal switch board of size 8-12 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement GI/pressed steel terminal switch board of size 4-6 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement GI/pressed steel terminal switch board of size 1-3 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
Taking down carefully existing aluminium/copper point wiring for light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells etc & making good the disturbed surfaces of walls/ceiling, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit ,medium grade,of suitable size with all accessories such as bend, reducers, MS hooks including galvanised/pressed steel moduar terminal boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 1.5 Sqmm PVC FRLSH stranded copper conductor unsheathed, insulated, stranded connected to common earth point dolly for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed . Note:- Proper colour coding is to be followed as per IS specifications.
All as per Srl item No 26. here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed
All as per Srl item No.26 here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed
All as per Srl item No 26. here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board but below the switch board of light points in same vertical plane complete all as specified and directed
All as per Srl item No 26 here-in-before but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire complete all as specified and directed
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc existing PVC/steel rigid conduit including galvanised/pressed steel moduar terminal boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 1.5 Sqmm PVC FRLSH stranded copper conductor unsheathed, insulated, stranded connected to common earth point dolly for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed . Note:- Proper colour coding is to be followed as per IS specifications.
All as per Srl item No.31here-in-before but for one light point controlled by one,two way switch complete all as specified and directed
All as per Srl item No 31.here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed
All as per Srl item No.31here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed
All as per Srl item No 31 here-in-before but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire complete all as specified and directed
S&F modular switch, one way 6 Amps , 1 module complete all as specifieds and directed .
S&F modular switch, two way 6 Amps , 1 module complete all as specifieds and directed .
S&F modular switch, one way, 16 Amps, 1 module complete all as specifieds and directed .
S&F modular socket 3 pin, 6 Amps, 2 module complete all as specifieds and directed.
S&F modular socket 3 pin, 6 A/16 Amps, 2 module complete all as specifieds and directed .
S&F modular fan regulator,120 Watt, 2 module complete all as specifieds and directed
S&F modular bell push ,6 Amps,240 volts , 1 module complete all as specifieds and directed .
S&F modular blank plate , 1 module complete all as specifieds and directed .
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc in existing PVC/steel rigid conduit with new provision of galvanised/ steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 3mm thick plastic laminated Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded connected to common earth point dolly for for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed . . Note:- Proper colour coding is to be followed as per IS specifications.
All as per Srl item No 44 here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed
All as per Srl item No.44 here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed
All as per Srl item No 44 here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board but below the switch board of light points in same vertical plane complete all as specified and directed
All as per Srl item No 44 here-in-before but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire complete all as specified and directed
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 volts, AC supply complete all as specified & directed
S&F switch piano, flush type, single pole, one way, 16 Amps, 230 volts, AC supply complete all as specified & directed
S&F bell push, flush type, 6 amps complete all as specified and directed
S&F Bell, ding dong, AC 230V, single pole complete all as specified and directed
S&F socket outlet, 3 pin, 6 Amp,flush type, 230 volts, AC supply complete all as specified & directed
S&F socket outlet, 3 pin, 15/16 Amp,flush type, 230 volts, AC supply complete all as specified & directed
S&F stepped type electronic fan regulator, flush type,single phase, AC supply, 230 V complete all as specified and directed
S&F ceiling rose, surface backelite, three terminal, 240 volts complete all as specifieds and directed .
S&F lamp holder,PVC /Polycarbonate type with back plate for batten fittings complete all as specifieds and directed . .
S&F in replacement LED lamp of capacity 07 Watt suitable for B22 holder complete all as specifieds and directed . . .
S&F LED light fitting 1 x 20Watt, 220V, Integrated batten type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose with all fixing arrengenment complete all as specifieds and directed .
S&F energy saving new generation 10W LED bulk head luminaire with opal diffuser, IP 65 and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 Hz complete all as specified and directed.
S&F Street light fitting, LED type, 30 Watt, 230V, AC with high pressure die cast aluminium housing/body, heat resistant complate with driver, lamp holder, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, complete with IP 66 protection on and including bracket of 25mm dia,light grade,GI pipe , 1.20 m and connecting with twin core twisted flexible copper conductor cable 1.5 sqmm complete with all accessories complete all as specified and directed.
S&F LED flood light 70/80 watts,230V,AC,outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver and lamp enclosed with glass cover including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED luminaire 600 mm x 600mm, 35/36 watt, 220 V,AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED luminaire round shape, 12 watt, 220 V,AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement of fancy type LED fitting 2x7 watts, E27 LED light frosted glass with chrome finishing wall lamp, fixture height 240mm complete all as specified and directed.
S&F factory made epoxy polyester powder coated distribution board TP&N ,4 ways (VTPN DB), double door,(concealed flush to wall) (IP-43 protection) fabricated from minimum 1.2 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 250 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with space for provision for 4 pole MCCB as incommer and outgoing MCBs as required at site and conforming to IS: 8623 along with cable end box including making good disturbed surface complete all as specified and directed. NOTE: (a) MCCBs and MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/ sleeves and its cost shall be deemed to be included under respective item of BoQ.
S&F MCCB four pole, 100 Amp, 16 KA, 415 volts with adjustable thermal settings complete all as specified and directed
S&F in replacement Sheet metal enclosure for DBs,TPN, double door,IP-43 protected, 415 Volts,4 ways with 200 amps rated copper bus bar complete all as specified and directed
S&F in replacement Sheet metal enclosure for DBs,SPN, double door,IP-43 protected, 240 Volts,12 ways with 200 amps rated copper bus bar complete all as specified and directed
S&F in replacement Sheet metal enclosure for DBs,SPN, double door,IP-43 protected, 240 Volts,8 ways with 200 amps rated copper bus bar complete all as specified and directed
S&F in replacement Sheet metal enclosure for DBs,SPN, double door,IP-43 protected, 240 Volts,4 ways with 200 amps rated copper bus bar complete all as specified and directed
S&F in replacement MCB TPN, 40-100 Amp, 415 Volts with rupturing capacity 10 KA, 'C' series, complete all as specifieds and directed .
S&F in replacement MCB SPN, 32 Amp, 240 Volts with rupturing capacity 10 KA, 'C' series, complete all as specifieds and directed .
S&F in replacement MCB Single pole, 6 to 32 Amp, 240 Volts with rupturing capacity 10 KA, 'C' series, complete all as specifieds and directed .
S&F Sheet metal enclosure for DBs,single door,IP-43 protected, 240 Volts,2 ways complete all as specified and directed.
S&F in replacement Sheet metal enclosure for DBs,SPN, single door,IP-43 protected, 240 Volts,2 ways complete all as specified and directed.
S&F in replacement MCB SPN, 40-63 Amp, 240 Volts with rupturing capacity 10 KA, 'C' series, complete all as specifieds and directed .
S&F in replacement submain wiring with two runs of single core PVC FRLSH unsheathed, insulated, copper cable of 10 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLSH copper wire 10 Sqmm for continous earth wire drawn into and including concealed PVC rigid conduit of suitable size including cutting chases in wall and making good all disturbed surfaces matching with existing surfaces complete all as specified and directed. Note :-Two runs of 10 Sqmm copper cable and one run of 10 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F in replacement submain wiring with two runs of single core PVC FRLSH unsheathed, insulated, copper cable of 6 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLSH copper wire 6 Sqmm for continous earth wire drawn into and including concealed PVC rigid conduit of suitable size including cutting chases in wall and making good all disturbed surfaces matching with existing surfaces complete all as specified and directed. Note :-Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F in replacement submain wiring with two runs of single core PVC FRLSH unsheathed, insulated, copper cable of 4 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLSH copper wire 4 Sqmm for continous earth wire drawn into and including concealed PVC rigid conduit of suitable size including cutting chases in wall and making good all disturbed surfaces matching with existing surfaces complete all as specified and directed. Note :-Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F in replacement 1100 volt grade, heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and overall PVC sheathed in service connections, suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 10 Sqmm complete all as specified and directed.
S&F in replacement 1100 volt grade, heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and overall PVC sheathed in service connections, suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 16 Sqmm complete all as specified and directed.
Taking down defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop, dismantling, examing & carrying out repair as required in all respect for smooth running and brought back to site, re-fixing in position, testing and comprising of the following:- (a) Servicing/overhauling of the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete. (b) M&L for opening, cleaning, drying and re-winding or BLDC circuit plate the burnt/short circuited PCB or winding with same guage super enameled copper wire to maintain speed at load. (c) M&L for preparing the surface by scraping the existing paint, finishing and spray painting to ceiling fan with one coat of synthetic enamel paint . (d) Replacement of ball bearing suitable for ceiling fan of existing sweep & Make/Model
Taking down defective exhaust fan/wall mounting fan/pedestal fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop, dismantling, examing & carrying out repair as required in all respect for smooth running and brought back to site, re-fixing in position, testing and comprising of the following:- (a) Servicing/overhauling the fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete. (b) M&L for opening, cleaning, drying and re-winding with same guage super enameled copper wire to maintain speed at load. (c) M&L for preparing surface, scrabing, finishing and painting of ceiling fan by applying one coat of synthetic enamel paint . (d) Replacement of ball bearing suitable for fan of existing sweep & Make/Model
S&F in replacement ball bearing suitable for ceiling fan of sweep1200mm/1400mm complete all as specified & directed.
S&F in replacement ball bearing suitable for exhaust fan of sweep300mm/450mm complete all as specified & directed.
S&F in replacement capacitor 2.5 mfd for ceiling fan complete all as specified & directed.
S&F in replacement capacitor 4 mfd for exhaust fan complete all as specified & directed.
S&F in replacement gun metal bush suitable for ceiling fan of sweep1200mm/1400mm complete all as specified & directed.
S&F in replacement gun metal bush suitable for exhaust fan of sweep300mm/450mm complete all as specified & directed.
S&F in replacement three core flexible wire of dia 1.0 sqmm for connecting up to ceiling fan/exhaust fan/wall mounting fan complete all as specified & directed.
S&F in replacement rubber bush,wheel type with nut,bolt,washers,locking clip etc. suitable for hanging of ceiling fan complete all as specified & directed.
S&F in replacement mounting clamps with nut, bolt, washers, locking clip etc suitable for fixing at the top of down rod of ceiling fan complete all as specified & directed.
S&F in replacement ceiling fan down rod of mild steel pipe 15mm bore of length 1.2/1.5m including cutting/threading, making tide for fixing providing check nuts washers and clamp with rubber bush etc complete all as specified & directed.
S&F in replacement casing caping of size 20 mm (ISI marked) complete all as specified & directed.
S&F exhaust fan,steel body,AC, single phase,copper winding with self closing GI louver shutter suitable for operation on 220/230 volts of 300mm sweep,1200 RPM complete all as specified & directed.
S&F exhaust fan, made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V,50 Hz,RPM 1200,copper winding of sweep 250mm complete all as specified and directed .
S&F in replacement electronic LED driver, 36 watt for panel type fitting of suitable size as per existing model complete all as specified and directed.
S&F in replacement LED driver for 9W/10W/11W/15W/20W fitting as per existing model complete all as specified and directed.
M&L for complete earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, precast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh ,15mm dia light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specifieds and directed ..
Taking down existing conduit with copper wire and S&F PVC non metallic rigid conduit, 20 mm external dia (medium grade) ISI marked exclusive of boxes but inclusive of all tees, bends, reducer, bell mouth tube ends and fixing accessories, concealed including cutting chases in wall, floor and making good all disturbed surfaces matching with existing surfaces and finally insering the existing copper wire in the conduit complete all as specified and directed.
S&F ceiling fan complete with blades,clamp, hooks,down rod and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) with compatible regulator and fixing of hooks by anchor fastner including connecting from ceiling rose/connector with & including flexible copper cable of suitable size complete all as specified and directed .
LAL CONSTRUCTIONS (BID ID -3404283)
Hi Tech Engineers (BID ID -3403631)
Durga Electricals (BID ID -3403985)
HARSH ELECTRICAL STORE (BID ID -3399888)
ASHOKKUMAR SURI (BID ID -3411659)
M/S RAJ ENGINEERS (BID ID -3403868)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .