Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Not yet disclosed by govt. Disqualified | Disqualified MII |
| 2 | Not yet disclosed by govt. Disqualified | Disqualified MSE, MII, Category: General |
| 3 | Not yet disclosed by govt. Disqualified | Disqualified MSE, MII, Category: SC |
| 4 | Not yet disclosed by govt. Disqualified | Disqualified MSE, MII, Category: General |
| 5 | Not yet disclosed by govt. Disqualified | Disqualified MII |
Tender Value
₹46.1 L
EMD Value
₹92,244
Closing Date
9 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SITC of
6578927
GEM/2024/B/5104520
Two Packet Bid
Supply of 1.5 TR Inverter type 5 Star rated split Air-Conditioner unit,Dismantling of existing 1.5
90 days
West Bengal; Kolkata
Total value wise evaluation
BOQ
9 documents required · 9 mandatory
3 yrs
₹3
30%
₹92,244
10 Jul 2024
28 Jun 2024
9 Jul 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supply of 1.5 TR Inverter type 5 Star rated split Air-Conditioner unit | Supply of 1.5 TR Inverter type 5 Star rated split Air-Conditioner unit as per BEE star rating, (as per BEE Notification dated 19th April 2022 or latest) with remote control unit, filters, rotary type compressor, copper tubes for both indoor and outdoor unit, Refrigerant gas with topping up of refrigerant if required, transportation of all of the above to the various sites and supplying the following up to the length of 3 mtrs. etc. as required.
(1) Hot and cold refrigerant piping
(2) suitable connecting electrical cable between indoor and outdoor unit.
Note--
1) The Manufacturers / Suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation, which is earlier. Thereafter 9 years (108 months) additional warranty on the compressor. | 87 | No | jtoelec.esdvi@electrical | 90 |
| 2 | Dismantling of existing 1.5 TR split AC unit - indoor and outdoor units | Dismantling of existing 1.5 TR split AC unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by Exch. in charge etc. as reqd. | 87 | No | jtoelec.esdvi@electrical | 90 |
| 3 | Installation, Testing and Commissioning of the Split AC unit at a specified location | Installation, Testing & Commissioning of the Split AC unit at a specified location by mounting/fitting Indoor and Outdoor units at their respective locations, laying and fixing of both liquid and hot gas lines, inter connecting wiring for both indoor & outdoor units up to 3 mtrs. length and interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene foam tubing unit, Leak testing entire system, charging Refrigerant gas in the unit, making power supply connections from the power point etc. complete as required. | 87 | No | jtoelec.esdvi@electrical | 90 |
| 4 | Supplying and fixing extra copper pipe line | Supplying and fixing extra copper pipe line both 1/4 inch for gas line and 5/8 inch for liquid line OR suitable dia to match with the pipeline of the new unit along with suitable size rubber foam/insulation on surface of the wall i/c necessary flare nuts, suitably brazing with the existing pipe clamping, making holes in walls, same etc. as per site requirement. NOTE - The length of refrigerant pipes supplied with each AC units is 3 Mtr. Extra length shall be paid extra for which firm shall quote their unit rates. | 261 | Mtr | jtoelec.esdvi@electrical | 90 |
| 5 | Supplying and laying 4core 2.5sqmm PVC insulated and PVC sheathed flexible copper cable | Supplying and laying 4core 2.5sqmm PVC insulated and PVC sheathed flexible copper cable along refrigerant pipe or on existing conduit / cable tray i/c binding with plastic tags for extending supply from existing industrial socket to indoor unit etc, as required . (Make- any ISI mark ) . NOTE- The length of Copper Cable supplied with each unit is 3 Mtr . Extra length shall be paid extra. | 261 | Mtr | jtoelec.esdvi@electrical | 90 |
| 6 | Supplying and fixing of Powder Coated MS frame stand | Supplying & fixing of Powder Coated MS frame stand comprising of Two numbers bracket made of heavy duty MS Sheet to accommodate the Condenser (Outdoor) unit for fixing on the wall with suitable diameter and length of Anchor fast bolts and making good the damages etc. as per site requirement. | 87 | Job | jtoelec.esdvi@electrical | 90 |
| 7 | Supplying and Fixing of 20 mm dia heavy duty PVC pipe with accessories for drain water connection | Supplying and Fixing of 20 mm dia heavy duty PVC pipe with accessories for drain water connection where ever required etc. complete as required.(Make- any ISI mark ) . | 87 | Mtr | jtoelec.esdvi@electrical | 90 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_6578927.pdf
GEM_BID
atc_87_sac_-_cntx-e-_-wbtc_15-06-2024_2024-06-28-16-35-04_d9e10b92614c6a3f35a2591024fb8e89.pdf
BOQ
boq_item_sample_file_2024-06-28-16-35-04_aee4378c58221b182ed80ad5fbd14846.csv
BOQ
ATC87SAC_790fa580-0916-4720-9e761719574857400_eeelectrical.kol@wbtc.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .