Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | ₹32.1 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹33.5 L+₹1.4 L (4.39%)Rejected-AOC | ₹33.5 L+₹1.4 L (4.39%) | L2 | Rejected-AOC NOT LOWEST |
Tender Value
₹29.2 L
EMD Value
₹58,400
Closing Date
13 Feb 2024, 6:00 pmClosed
CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
PROVISION OF CERTAIN E/M WORKS UNDER GE NORTH BANGALORE
2023_MES_627857_2
86199/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Bangalore
As per NIT
8 documents required · 8 mandatory
₹500
GE(North) Bangalore
₹58,400
Yes
7 Mar 2024
11 Jan 2024
20 Feb 2024
11 Jan 2024
13 Feb 2024
25 Jan 2024
11 Jan 2024 - 18 Jan 2024
Amount
Supply, laying and testing cable XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm 3.5 core all as specified and as directed.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 metre connected to and including galvanized iron strip 32 x 6 mm as earthing lead up to 7.5 metre long by means of nuts, bolts, thimbles, check nuts and washer etc made of galvanized iron connected to earthing test point through protection pipe light grade of 20 mm dia all as shown in electrical plate No 3 of SSR Part - I 2009 and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, precast slab of 40mm thick in cement concrete (1:2:4) type B1, with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe of 20 mm dia medium grade ,wire mesh and lugs, including test point including cable connected with suitable size copper lugs complete all as specified and as directed.
Supply and Install hi wall split units indoor/outdoor complete with cordless remote control unit and within built air ionizer and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and as directed. Make: Hitachi /Voltas /Carrier.
Supply and Install hi wall split units indoor/outdoor complete with cordless remote control unit and within built air ionizer and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR complete all as specified and as directed. Make: Hitachi /Voltas /Carrier.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA all as specified and as directed. Make: V-Guard/Blue Star.
Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA all as specified and as directed. Make: V-Guard/Blue Star.
Supply and fixing of sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqmm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed.Note:- 3 runs of cable and one run of conduit will be measure as one Unit Length
Supply and fixing of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one double pole MCB 20 Amps all as specified and as directed.
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS: 10001/10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc of capacity up to 62.5 KVA all as specified and as directed.
Supply and installation of Retrofit for emission control device for 62.5/63 KVA DG Set of any make/vintage. NOTE: (a) Above scope of work includes complete supply of device along with control panel at site. (b) Installation of the RECD device on the diesel Genset. (c) RECD test and DG on load commissioning after fitment of RECD. (d) All related activities to ensure RECD is supplied, installed and commissioned on the DG Set. (e) Providing of certificate from any of 1 of the 5 labs stating that the RECD reduces PM 2.5% and makes the DG Set compliant to the CAQM directive all as specified and as directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cables/ erection of pole etc complete all as specified and as directed.
Returning, filling in trenches including spreading leveling watering and well ramming in layers with hard/dense soil not exceeding 25 cm thick in each layer complete as specified and as directed.
Removing excavated surphlus soil to a distance not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and Labour for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed.
Supply and laying of sub class 'B' burnt bricks for cable protection complete as specified as directed
Supply and laying cable XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including necessary road crossing if applicable for following size of 4 Core x 16Sqmm all as specified and as directed.
Labour and transport for shifting of following DG set and their LT panel of any capacity from one location to another location up to 10 Km with the help of mechanical transport and re-connecting all the LT connection at new location all as specified and as directed by Engr-in-charge:- (a) 100 KVA DG Set
(b) All as per item No 17 hereinbefore but 30 KVA DG Set all as specified and as directed.
Installation commissioning of DG set and connected accessories at site (LT panel) and all as specified and directed by Engr-in-charge.
Material and Labour for DG Set foundation for 100 KVA DG Set for the following DG set with PCC 1:4:8 type D-2 for foundation(using 40mm graded stone aggregate), brick work in cm 1:6 and rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including necessary earth work for all as specified and as directed. Note :- Foundation of DG should be 45cm more than outer cover of DG set Length x Width
All as per item No 20 hereinbefore but 30 KVA DG Set all as specified and as directed.
Supply and fixing of MCB DB TPN 4 way harizontal type with double door type 415 volts with 200 Amps rated bus bar with IP42 protection for housing MCBs complete all as specified and as directed.
Supply and fixing of MCB DB SPN 12 way harizontal type with double door type 240 volts with 200 Amps rated bus bar with IP42 protection complete all as specified and as directed.
Supply and fixing of in replacement of MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed
Supply and fixing of in replacement of MCB SPN 240 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed
Supply and fixing of in replacement of MCB single pole 240 volts 20 Amps complete all as specified and as directed
Material and Labour for sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqmm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC casing capping all as specified and as directed. Note: 3 run of cable and one run of PVC casing / capping shall be measured as one running length.
Material and Labour for sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqmm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC casing capping all as specified and as directed. Note: 3 run of cable and one run of PVC casing / capping shall be measured as one running length.
Supply and fixing of in replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps. Note: 3 runs of cable and one run of PVC casing/capping shalll be mesusred as one running length
Supply and fixing of GI tubing light grade 32 mm bore with all fitting laid in trenches/walls/Roads for cable protection.
Fixing only transfer Geyser of capacity 25 Litres at various location including hot and cold PVC pipe, nut and bolts for hanging and including necessary plumbing work etc complete all as specified and as directed.
Fixing only transfer Air Conditioning of capacity 1.5 Ton after servicing and filling refrigent at various location including all connected accessories such as copper inlet/outlet pipe up to 3 metre and necessary electrical work all as specified and directed.
Material and Labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 metre long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1, with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including test point complete all as specified and as directed.
M.S.Trading Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .