Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.9 L+₹3.6 L (13.9%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Haasith constructions L1 | SRI SAI RAM ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00Note : 1. The contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safely measures are to be adopted by contractor on site. 3. The contractor shall provide and deploy sufficient manpower (as approved by GE / Engineer in charge) shall report at 9:00 hrs to JE E/M / Engineer in Charge to collect the complaints job card in working days and complete the same completed within 24 Hrs. 4. The complaints shall be rectified within 24 Hrs if the complaints is/are not attended / not completed within 24 Hrs (Except repair/replacement of major items) recovery will be done at Rs 500 per complaint per day. 5. After completion of job work complaint, the contractor has to produce job card duly signed by user & JE / Engineer in Charge. 6. If contractor failed to provide their electrician to attend the complains then recovery will be done at Rs 1000 per day. 7. The contractor should procure minimum 50% of the materials for all items as per BOQ (Other than paints) mentioned in this CA, within 20 days after getting sample approval and kept in safe custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of work. If contractor fail to complete the work within contract due to lack of fittings a penalty of 20% shall be applicable on quoted rates by the contractor. 8. In repair works, rate quoted for demolition /dismantling /taking down is deemed to be inclusive of removing the same from site and station. 9. In maintenance works, the contractor should maintain separate registers for repair works. Day to day complaints should be noted in those registers with SI nos of complaints, location qty of work, status of complaints and signature of in charge and stamp of the office. Formal will be given from concern AGE office. The contractor should obtain the signature of in charge on the same day of work. These register to be submitted to JE (E/M) on every weekend without fail. 10. The contracts involving working at elevated locations of buildings, contractor should ensure proper safety arrangements as per norms. Wearing safety belts and helmets are mandatory. A penalty of Rs 1000 per day will be recovered from contractor if safety norms are not followed. 11. The plumbing complaints resulting wastage of water should be rectified within 12 working hours and if contractor fail to fulfill this, a recovery of 10% of rate quoted for relevant item will be charged from contractor in this regard. 12. After completion of work, no stores/debris/ loose items be kept at work site or dumped inside station . Entire area to be cleared and waste material be taken outside from the station . | |||||
| 1.01 | Dismantiling of mild steel work of any description not other wise provided for completed all as directed. | 2 | Qtl | 20 ₹40 Lowest | 500 ₹1,000 |
| 2.00 | S&F angle/ flate iron/chanel framed work such as iron gate, ladder, SWT frame, grills, gratings,framed guard bars, etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 290 Gde E-165 | 200 | Kg | 97 ₹19,400 Lowest | 100 ₹20,000 |
| 3.00 | Demolation of brick or stone/ boulder built in cement mortar. | 10 | Cum | 40 ₹400 Lowest | 350 ₹3,500 |
| 4.00 | M & L for Pre-cast cement concrete block masonry with solid blocks, Type C1 1:3:6 (20mm graded aggregate) exc. 10 cm in width and setting in cement mortar 1:4, complete | 10 | Cum | 670 ₹6,700 Lowest | 6,000 ₹60,000 |
| 5.00 | Material and labour PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in copings all as specified and directed. | 1 | Cum | 3,950 ₹3,950 Lowest | 7,000 ₹7,000 |
| 6.00 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 , finished even and smooth without using extra cement | 100 | Sqm | 158 ₹15,800 Lowest | 200 ₹20,000 |
| 7.00 | Dismandling of RCC fencing post in any section including taking out embedded portion. | 150 | RM | 20 ₹3,000 Lowest | 300 ₹45,000 |
| 8.00 | Dismantling of fencing wire mesh, any size | 250 | Sqm | 8 ₹2,000 | 5 ₹1,250 Lowest |
| 9.00 | M & L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete. | 2.7 | Cum | 4,108 ₹11,091.6 Lowest | 5,000 ₹13,500 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Dec 2025, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
COMPREHENSIVE REPAIR TO ELECTRIC INSTALLATIONS, STP PLANTS AND REPAIRS, RENEWALS AND MAINTENANCE TO STP PLANT, NON CLOG PUMP SETS, FIRE FIGHTING SYSTEM, FIRE ALARMS, SOLAR PV AND OTHER ALLIED WORKS AT AFS BEGUMPET, CAW AND OFFICERS RESIDENTIAL AREA
2025_MES_740233_1
8861/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Begumpet and CAW
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Hakimpet
₹70,000
Yes
9 Jan 2026
17 Nov 2025
10 Dec 2025
17 Nov 2025
8 Dec 2025
1 Dec 2025
Amount
Note : 1. The contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safely measures are to be adopted by contractor on site. 3. The contractor shall provide and deploy sufficient manpower (as approved by GE / Engineer in charge) shall report at 9:00 hrs to JE E/M / Engineer in Charge to collect the complaints job card in working days and complete the same completed within 24 Hrs. 4. The complaints shall be rectified within 24 Hrs if the complaints is/are not attended / not completed within 24 Hrs (Except repair/replacement of major items) recovery will be done at Rs 500 per complaint per day. 5. After completion of job work complaint, the contractor has to produce job card duly signed by user & JE / Engineer in Charge. 6. If contractor failed to provide their electrician to attend the complains then recovery will be done at Rs 1000 per day. 7. The contractor should procure minimum 50% of the materials for all items as per BOQ (Other than paints) mentioned in this CA, within 20 days after getting sample approval and kept in safe custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of work. If contractor fail to complete the work within contract due to lack of fittings a penalty of 20% shall be applicable on quoted rates by the contractor. 8. In repair works, rate quoted for demolition /dismantling /taking down is deemed to be inclusive of removing the same from site and station. 9. In maintenance works, the contractor should maintain separate registers for repair works. Day to day complaints should be noted in those registers with SI nos of complaints, location qty of work, status of complaints and signature of in charge and stamp of the office. Formal will be given from concern AGE office. The contractor should obtain the signature of in charge on the same day of work. These register to be submitted to JE (E/M) on every weekend without fail. 10. The contracts involving working at elevated locations of buildings, contractor should ensure proper safety arrangements as per norms. Wearing safety belts and helmets are mandatory. A penalty of Rs 1000 per day will be recovered from contractor if safety norms are not followed. 11. The plumbing complaints resulting wastage of water should be rectified within 12 working hours and if contractor fail to fulfill this, a recovery of 10% of rate quoted for relevant item will be charged from contractor in this regard. 12. After completion of work, no stores/debris/ loose items be kept at work site or dumped inside station . Entire area to be cleared and waste material be taken outside from the station .
Dismantiling of mild steel work of any description not other wise provided for completed all as directed.
S&F angle/ flate iron/chanel framed work such as iron gate, ladder, SWT frame, grills, gratings,framed guard bars, etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 290 Gde E-165
Demolation of brick or stone/ boulder built in cement mortar.
M & L for Pre-cast cement concrete block masonry with solid blocks, Type C1 1:3:6 (20mm graded aggregate) exc. 10 cm in width and setting in cement mortar 1:4, complete
Material and labour PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in copings all as specified and directed.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 , finished even and smooth without using extra cement
Dismandling of RCC fencing post in any section including taking out embedded portion.
Dismantling of fencing wire mesh, any size
M & L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete.
M&L Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde E 250) Quality A or Fe-290 (Gde E-165)
M&L for MS screw bolts (machine made) 5to 10mm dia with hexangonal or squre head at one end screwd other or screwd end fitted with wishers and one hexogonal or square nut exc 5cm long all as directed.
Supply only PVC coated Chain link fencing of size 75 mmx 75 mm (Electriplating GI 2.5mm wire + 1.5 mm PVC Coating) 4 mm wire dia after PVC coating.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire
M&L, preparing new or previously untreated steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed.
M&L Surfaces of any description, n. exc 10cm in width or girth and preparation of new untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of Red oxide zinc chrome all as directed by Engineer-in-Charge.
M&L for preparing old painted steel and iron surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
S & F Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm barbs at 100mm spacing all as specified fixed in repair.
S & F Mild steel work in hand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 290 Gde E-165
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed.
M&L for Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F Double legged informatory sign board as double side fixed on single frame and meeting back to back on square pipe. The boards shall be high intensitive grade retro reflective sheeting (AVERY DENNISON) of Green / Blue or any approved colour as per IRC standards complete all as specified and directed. Note:- A. The Boards shall be made of Alco bond sheet as required size of 1.5 mtr X 1.2 mtr. Retro reflective sheeting is fixed on this Alco bond sheets with suitable adhesive. The letter writing (as directed) is done with computerised cut machine and fixed on this retro reflective sheeting. This board is mounted on the MS frame and fixed on the frame with POP revets. B. For double sided board two such boards made of Alco Bond sheets fixed on the single frame with back to back. This are mounted with POP revets C. Fixing of board incl all fixing arrangement deemed to be included in this item. D. Letter writing (size, Nos of letters, colour etc) will be decided and directed by Engr-in-charge E. Rate shall include one measurement for double side back to back F. Lighting arrangement as directed shall be included in above quoted rate. G. Supplying and fixing of MS pipe for mounting board of suitable dia and height shall be included in above rate
M&L for loose filling with aggregate of gauge 40 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface of transformer and two pole / four pole structure complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
S&F post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp including provision of mounting pole of suitable dia and height complete all as specified and directed.
Supply and laying or fixing passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 4 sq. mm nominal cross section in service connections complete all as specified and directed.
M&L for MS chequred plate of thickness 5mm including cutting into required shape fixing on equal angle complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of MS bracket for mounting flood light fitting made out of MS angle iron of size 40x40x6 mm of length not less than 1.0 mtr, fixed to pole/ earth and grout using pcc & clamp, nut & bolts including painting of bracket with one coat of synthetic enamel paint over a coat of red oxide primer complete
S&F Exhaust fan, steel body, steel body AC Single phase 230 V of size 300 mm sweep with blades, and frame and louvers complete all as specified and directed by Engr-in-charge
M&L for cutting round holes suitable for fixing of exhaust fan of size upto 450 mm into through stone walls built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required and plastering in CM 1:4 external / internal surfaces and finished to match with the existing surfaces complete all as specified and directed by Engr-in-charge.
M&L for cement concrete (1:2:4) type B1 with 20 mm graded aggegate for plinth and staging of LT Panel Boards/ substn yard area including necessary work for preparation of base work and form work and finishing to all exposed surfaces by using extra cement all as directed.
M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engr-in-charge.
M & L for writing of letters on motors, pipeline and building not exceeding 30 cm height complete all as specified and directed by Engr-in-charge.
S & F of electro magnetic flow meter suitable for diameter of 80 mm dia built in earthing electrode including fixing of electronic display unit IP 65 which measures forward, back and total capacity of water flow through meter in cum/hr including power supply of AC 230 Volts and all electrical connections, sensor cable, M20 cable gland complete all as specified and directed by Engr-in-charge.
M & L for preparation of old painted surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
M & L for provision of box screen chamber of stain less steel of size 500 mm x 500 mm at MBBR tanks complete all as specified and directed by Engr-in-charge.
M & L for maintenance of air blowers including oil seal replacement, bearing replacement, oil filling, greasing complete all as specified and directed by Engr-in-charge.
Supply and installation of dosing system including dosing 0.25 HP induction motor, ejector, 6 mm pipe of required length complete all as specified and directed by Engr-in-charge.
Supply and installation of HDPE Pipe 100 litre capacity for dosing system complete all as specified and directed by Engr-in-charge.
M&L for replacement of filtration media of various layers of sand bed (fine sand, coarse, gravels, pebbles etc ) and removal of old media and cleaning of vessel, filling of new media etc in vessel size of 1600mm x 1800mm in pressure sand filter complete all as specified and directed by Engr-in-charge.
M&L for replacement of filtration media of various layers of sand bed (fine sand, coarse, gravels, pebbles etc ) and activated carbon media -600 IV above sand bed above sand bed and removal of old media and cleaning of vessel, filling of new media etc in vessel size of 1600mm x 1800mm in activated carbon filter complete all as specified and directed by Engr-in-charge.
S&F of V Belt of A 50 model complete all as specified and directed by Engr-in-charge.
S& F of butterfly valve of 80 mm dia complete all as specified and directed by Engr-in-charge.
S&F of butterfly valve of 50 mm dia complete all as specified and directed by Engr-in-charge.
S&F of multi stage non clog submersible pump set of capacity 2.0 HP of flowing discharge capacity 100 LPM to 600 LPM for outlet pipe of dia 50mm suitable for operation of 3 phase 415 volts including connecting accessories, fittings complete all as specified and directed by Engr-in-charge.
Supply only LED torch light 5 Watt long range rechargeble with side light and lithium ion battery of capacity of 3.7 V 1200 mAh complete all as specified and directed by Engr-in-charge. Make : BEAM 50 Havells or equivalent CG/Phillips /Bajaj
Supply only head torch light rechargeble one 3.7 V 1200 mAh with flexible head band and adjustable neck for better light of 3 Watt capacity complete all as specified and directed by Engr-in-charge. Make : Havells TREKBAND or equivalent CG/Phillips/ Bajaj
Material and labour for MS chequred plate of thickness 5mm including cutting into required shape fixing on equal angle complete all as specified and as directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead strip 32x6 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ NOTE - The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe
M&L for Earth Continuity conductor or Main Earth lead fixed to wall or batten or recess or chasses or burried in ground or drawn in conduit /pipe or fixed to poles or any any other indicated satution for loop earthing etc of size 32x6 galvased iron strip.
Repairs and Maint of LT Feeder pillar Boxes , replacing the unserviceable door hinges, locks , cutting the burnt portion of cable / lugs and crimping with new lugs of suitable size and connecting . Painting the Feeder Pillar Box with approved colour
Desludging of equalization tank of size 7.55 metres x 7.55 metres x 3.8 metres at STP (500 KLD capacity) completely by getting out sludge in every three months through sucking super soccer machine / manually and removal by using Sewage Non clog Sludge pump set, transporting sludge to location not beyond 1000 mtr distance at isolated place, cleaning internal surfaces, white washing, painting to side railing completely all as specified and as directed by Engineer-in-Charge.
M & L for desludging and cleaning of existing Stilling Chamber (SC) of STP (500 KLD capacity) and getting out sludge through sucking super socker machine/ manually and removal by using Sewage Non clog Sludge pump set, and removing and transporting sludge to location not beyond 1000 mtr distance at isolated place complete all as directed by Engineer-in-Charge. Note :- Pumping out sludge water from chamber / tank by using Diesel engne operated pump and necessary diesel is to be arranged by contractor completed all as directed by Engineer-in-Charge.
All as per item No - 52 but for desludging and cleaning of existing Fine Bar Screen Chamber of STP (500 KLD capacity).
All as per item No - 52 but for desludging and cleaning of existing GRIT Chamber (GC) oil and greese trap (CAGT) of STP (500 KLD capacity).
All as per item No - 52 but for desludging and cleaning of existing Anoxic Tank of STP (500 KLD capacity).
All as per item No - 52 but for desludging of existing MBBR tank 1 & MBBR tank 2 of STP (500 KLD capacity).
All as per item No - 52 but for desludging and cleaning of existing Intermediate Tank of STP (500 KLD capacity).
All as per item No - 52 but for desludging of existing Tube settler tank of STP (500 KLD capacity).
All as per item No - 52 but for desludging of existing set of Filter Feed Cum Chlorine Contact Tank of any size at STP (500 KLD capacity).
All as per item No - 52 but for desludging and cleaning of existing Treated Water Ttank of STP (500 KLD capacity).
All as per item No - 52 but for Desludging and cleaning of existing Sludge Tank of STP (500 KLD capacity).
All as per item No - 52 but for desludging and cleaning of existing Dual Media Filter (DMF) of STP (500 KLD capacity).
All as per item No - 52 but for desludging and cleaning of existing Activated Carbon Filter (ACF) of STP (500 KLD capacity).
All as per item No - 52 but for desludging and cleaning of existing Centrifuge of any size of STP (500 KLD capacity).
Desludging of Sewage wells of size upto 6m dia and 6m depth at diefferent locations i.e rear of Gurudwara, near swimming pool, near Krishna Mandir at Begumpet and getting out sludge through sucking super socker machine/ manually and removal by using Sewage Non clog Sludge pump set, and removing and transporting sludge to location not beyond 1000 mtr distance at isolated place complete all as directed by Engineer-in-Charge. Note :- Pumping out sludge water from chamber / tank by using Diesel engne operated pump and necessary diesel is to be arranged by contractor completed all as directed by Engineer-in-Charge.
Testing of chemical & Bacteriological quality of inlet (Raw water) and out let (treated water) sewage water of following parameters from state public health laboratory or NABL accredited laboratory. All samples to be collected from 500 KLD STP at AFS Begumpet. The treated sewage shall have following characteristics :- (a) pH = 6.5 to 8.5 (b) Suspeded solids = Less than 10 mg/l (c) Total dissolved solids (d) C.O.D = Less than 30 mg/l (e) BOD( 3 days at 27 degree C) mg/l = Less than 3 mg/l (f) Oil & Grease = Less than 1 mg/l (g) Faecal Coli form MPN/ 100 ml, maximum = Less than 200 (h) Total Coli form MPN/ 100 ml, maximum = Less than 200 (i) Faecal streptococci MPN/ 100 ml, maximum = Less than 200
Notes:- 1. Any other parameters required by Pollution Control Board shall be complied by the Contractor at no extra cost. The contractor shall submit the report contirming the above parameters for the testing of treated water on monthly basis from reputed/ Govt. approved Laboratory, The test report of treated water shall confirming the above parameters within the permissible limit of (+/-) 5%. Contractor will provide monthly testing of sewage inlet & outlet water of all STP's containing following parameter : PH value, Total suspended solids, oil & grease, BOD, COD as per IS 3025 (P-1) - 1987 from Govt / State Lab or approved NABL, Accredited laboratory and rate of same is deemed to be included in unit quoted rate. 2. Contractor will provide all testing instrument and a test lab in installation for instant testing at installation / STP for BOD incubator PH value, Temperature controller, Digital Nephelo tubidity meter digital TSD meter Digital PH meter and digital water marker in water testing lab testing, display chart on lab. No extra amount shall be paid for test lab & testing instrument
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft / loose dense soil, including removal of Bushes, grass, weeds, shrubs alongwith roots etc. and cleaning of all the area i.e surroundings of Sewage Treatment Plant of capicity 500 KLD - 01 No and surroundings of Sewage wells at diefferent locations i.e rear of Gurudwara - 01 No, near swimming pool - 01 No, near Krishna Mandir - 01 No( at AFS Begumpet Area) including treating the area by spraying anti vegetarian growth chemicals, including taking away all the waste from site and burning all as directed. all as directed by Engineer-in-Charge.
Dismantling the delivery pipe line of Non Clog Vertical Submersible Pump set of any capicity from sewage well, lifting / taking out of GI column Pipes of any dia including submersible cable and defective submersible pump set from bore well for servicing / repairs and lowering of repaired submersible pump set with GI column pipe of any dia, submersible cable etc. complete in the sewage well at various sites. The job is inclusive of M&L for disconnecting and jointing of submersible cable, disconnecting and reconnecting the delivery pipe line of submersible pump sets to sewage wells, testing for satisfactory running & continuous flow of sewage complete all as specified & as directed by the Engineer-in-Charge.
Repairs & Servicing of defective Pump of Non Clog Vertical Submersible of capacity upto 30 HP by dismantling the pump & replacinig unserviceable parts, assemble the pump properly, testing for satisfactory functioning complete all as specified and as directed. Note: (i) The rate are inclusive of trasporting the pump from bore well site to repair work shop & back to site. (ii) The rates are inclusive of turning / finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be measured and paid separately under relevant Items. (iv) The rates are inclusive of testing of pump at borewell installation for satisfactory functioning / running.
Supply only for the following unserviceable Pump parts of Non Clog Vertical Submersible of capacity upto 16 HP, as per existing or make as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
CI stage Casing
G M Bush
SS Sleeve
Brass impeller
MS key for Impeller
SS studs with Nuts 10mm
CI intermediate Section
SS coupling bush common for Pump & Motor with key
High Tensile steel shaft
Strainer
Supply only for the following unserviceable Pump parts of Non Clog Vertical Submersible of capacity upto 30 HP, as per existing make or as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
CI stage Casing
G M Bush
SS Sleeve
Brass impeller
MS key for Impeller
SS studs with Nuts 10mm
CI intermediate Section
SS coupling bush common for Pump & Motor with key
High Tensile steel shaft
Strainer
Repairs & Servicing of defective motor of Non Clog Vertical Submersible of capacity upto 30 HP by dismantling the motor & replacing unserviceable parts, assemble the motor properly, testing for satisfactory functioning complete all as specified and as directed. Note: (i) The rate are inclusive of transporting the motor to repair work shop & back to site. (ii) The rates are inclusive of turning / finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be measured and paid separately under relevant item. (iv) Rewinding of motor & servicing of Rotor if required will be measured & paid separately under relevant items. (v) The rates are inclusive of testing of motor at borewell installation for satisfactory functioning / running.
Supply only for the following unserviceable parts of motor of Non Clog Vertical Submersible of capacity upto 16 HP, as per existing make or as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
Bearing bush Gunmetal
Bearing Bush SS with Rubber
Oil seal
Thrust plate / thrust bearing set.
Sand Guard
CI thrust Casing
SS studs with nuts 8 MM
Supply only for the following unserviceable parts of motor of Non Clog Vertical Submersible of capacity upto 30 HP as per existing make as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
Bearing bush Gunmetal
Bearing Bush SS with Rubber
Oil seal
Thrust plate / thrust bearing set.
Sand Guard
CI thrust Casing
SS studs with nuts 8 MM
Rewinding of motor of Non Clog Vertical Submersible of capacity upto 16 HP by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure and dried, rewinding the motor using same gauge of insulated copper wire as existing, making the winding leak proof by applying varnish, drying etc., taking out the electrical terminals using suitable size of submersible flat cable upto 2.0 M, installing at its original position complete all as specified & as directed by the Engineer-in-Charge.
Rewinding of motor of Non Clog Vertical Submersible of capacity upto 30 HP by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure and dried, rewinding the motor using same gauge of insulated copper wire as existing, making the winding leak proof by applying varnish, drying etc., taking out the electrical terminals using suitable size of submersible flat cable upto 2.0 M, installing at its original position complete all as specified & as directed by the Engineer-in-Charge.
Dismantling existing unserviceable of Twin lobe Air Blower 350 cum / hr replacing defective components, carrying out servicing, assembling completely and test run blower to the satisfaction of Engr-in-Charge. Note: (i) The rate are inclusive of transporting the blower to repair work shop & back to site. (ii) The rates are inclusive of turning / finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be measured and paid separately under relevant item. (v) The rates are inclusive of testing the blower at STP installation for satisfactory functioning / running.
Supply only for the following unserviceable parts of Twin lobe Air Blower 350 cum / hr, as per existing make or as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
(a) Single row cylindrical roller Bearing suitable for Twin lobe air compressor 330 cum/hr
(b) Twin lobes suitable for Twin lobe air compressor 330 cum/hr
(c) V-Belt suitable for Twin lobe air compressor 330 cum/hr
(d) Gear oil (Servo Gear HP 90)
Taking down the existing unserviceable Twin lobe Air Blower 350 cum / hr and supply and fix complete blower assembly as per the existing make or as approved by Engr - in -Charge including supply & fix suitable size of V-Belt, supply and fill gear oil of suitable grade matching with the specifications of blower/OEM, assembling completely with existing 15 HP motor and test run the blower to the satisfaction of Engr-in-Charge. Note: (a) Quoted rate shall deemed to be included complete cost of transportation, labour, Spare parts, components, tools, and commisioning to the satisfaction of Engr-in-Charge.
Dismantling the delivery & suction pipe line of monoblock / centrifugal pump / Induction Motor of any capacity from 500 KLD STP , unscrewing foundation nuts, bolts and disconnecting electric supply, lifting / taking out defective pump set for repairs and re-installation of repaired pump set & connecting suction and delivery pipes & making electrical connections, tightening of foundation nuts & bolts after proper alignment. The Job is inclusive of testing for satisfactory running & continuous flow of water complete all as specified & as directed by the Engineer-in-Charge.
Repairs & servicing of defective monoblock / centrifugal pump set of capacity 0.5 HP to 3 HP from 500 KLD STP by dismantling the pump & removing unserviceable parts, assemble the pump properly after replacement of unserviceable parts all as specified and as directed by the Engineer-in-charge. NOTE:- (i) The rate quoted is deemed to be inclusive of transporting the pump from STP site to work shop & back to site. (ii) The rate quoted is deemed to be inclusive of turning/finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be paid & measured separately under relevant items. (iv) The rate quoted is deemed to be inclusive of oiling, greasing to bearing and bushes, providing suitable size of gland rope, replacement of foundation bolts, leak testing of pump at water supply installation for satisfactory functioning / running.
Supply only for the following unserviceable parts of monoblock / centrifugal pump set of capacity 0.5 HP to 3 HP, as per existing make or as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
CI Gland coller
SS Sleeve
MS/CI Impeller
MS key for Impeller
SS studs with Nuts 10 mm
SS coupling with rubber bushes common for Pump & Motor with Key, Nut bolts etc.
High Tensile steel shaft
SS bearings
Metallic motor cooling fan blade .
Rewinding of electrical motor of capacity 0.5 HP to 3 HP by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure, cleaning with CTC, dried and rewinding the motor using same gauge of insulated copper wire as existing & making the winding leak proof by applying warnish, drying etc. and re-connecting at its original position including testing of motor after installation for satisfactory functioning / running all as specified and as directed by the Engineer-in-charge.
Repairs & servicing of defective monoblock / centrifugal pump set of capacity 5 HP from 500 KLD STP by dismantling the pump & removing unserviceable parts, assemble the pump properly after replacement of unserviceable parts all as specified and as directed by the Engineer-in-charge. NOTE:- (i) The rate quoted is deemed to be inclusive of transporting the pump from STP site to work shop & back to site. (ii) The rate quoted is deemed to be inclusive of turning/finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be paid & measured separately under relevant items. (iv) The rate quoted is deemed to be inclusive of oiling, greasing to bearing and bushes, providing suitable size of gland rope, replacement of foundation bolts, leak testing of pump at water supply installation for satisfactory functioning / running.
Supply only for the following unserviceable parts of monoblock / centrifugal pump set of capacity 5 HP, as per existing make or as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
CI Gland coller
SS Sleeve
MS/CI Impeller
MS key for Impeller
SS studs with Nuts 10 mm
SS coupling with rubber bushes common for Pump & Motor with Key, Nut bolts etc.
High Tensile steel shaft
SS bearings
Metallic motor cooling fan blade .
Rewinding of electrical motor of capacity 5 HP by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure, cleaning with CTC, dried and rewinding the motor using same gauge of insulated copper wire as existing & making the winding leak proof by applying warnish, drying etc. and re-connecting at its original position including testing of motor after installation for satisfactory functioning / running all as specified and as directed by the Engineer-in-charge.
Repairs & servicing of defective monoblock / centrifugal pump set of capacity 15 HP from 500 KLD STP by dismantling the pump & removing unserviceable parts, assemble the pump properly after replacement of unserviceable parts all as specified and as directed by the Engineer-in-charge. NOTE:- (i) The rate quoted is deemed to be inclusive of transporting the pump from STP site to work shop & back to site. (ii) The rate quoted is deemed to be inclusive of turning/finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be paid & measured separately under relevant items. (iv) The rate quoted is deemed to be inclusive of oiling, greasing to bearing and bushes, providing suitable size of gland rope, replacement of foundation bolts, leak testing of pump at water supply installation for satisfactory functioning / running.
Supply only for the following unserviceable parts of monoblock / centrifugal pump set of capacity 15 HP, as per existing make or as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
CI Gland coller
SS Sleeve
MS/CI Impeller
MS key for Impeller
SS studs with Nuts 10 mm
SS coupling with rubber bushes common for Pump & Motor with Key, Nut bolts etc.
High Tensile steel shaft
SS bearings
Metallic motor cooling fan blade .
Repairs & servicing of defective inductiont motor of capacity 15 HP from 500 KLD STP by dismantling the motor & removing unserviceable parts, assemble the motor properly after replacement of unserviceable parts all as specified and as directed by the Engineer-in-charge. NOTE:- (i) The rate quoted is deemed to be inclusive of transporting the motor from STP site to work shop & back to site. (ii) The rate quoted is deemed to be inclusive of turning/finishing work for fixing of parts properly. (iii) The replacement of unserviceable parts will be paid & measured separately under relevant items. (iv) The rate quoted is deemed to be inclusive of oiling, greasing to bearing and bushes, , replacement of foundation bolts, leak testing of pump at water supply installation for satisfactory functioning / running.
Supply only for the following unserviceable parts of inductiont motor of capacity 15 HP, as per existing make or as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item) :-
High Tensile steel shaft
SS bearings
Metallic motor cooling fan blade .
Rewinding of electrical motor of any type of capacity 15 HP by taking out burnt copper winding from stator, cleaning the casing & slots with wire brush & washing with water under pressure, cleaning with CTC, dried and rewinding the motor using same gauge of insulated copper wire as existing & making the winding leak proof by applying warnish, drying etc. and re-connecting at its original position including testing of motor after installation for satisfactory functioning / running all as specified and as directed by the Engineer-in-charge.
Repairing fully Auto-matic star delta starter of capacity upto 30 HP, replacing defective components and test run to the satisfaction of Engr-in-Charge. Note: (a) Quoted rate shall deemed to be included complete except cost of components (b) Components will be measured and paid seperately under the relevent item this schedule.
Supply only for the following unserviceable parts of fully Auto-matic star delta starter of capacity upto 30 HP as per existing make or as approved by Engr - in Charge (fixing charges will be measured and paid under relevent item). Make as per the existing or as approved by Engr - in Charge :-
(a) Power contactor 3P, AC3, suitable for motor 15HP/20HP
(b) NO/NC Relay for mounting on contactor
(c) Start/stop Push button
(d) Motor ON/OFF indicator light
(e) Timer suitable for star delta starter
Taking down unserviceable DOL starter of capcity upto 12.5 HP and supply and fix DOL starter suitable for Pump set of capacity upto 12.5 HP, make as per the existing or as specified by the Engineer-in-charge.
Taking down unserviceable star delta starter starter of capcity upto 15 HP and supply and fix star delta starter suitable for, submersible pump set, induction motor of capacity upto 15 HP, make as per the existing or as specified by the Engineer-in-charge.
Taking down unserviceable star delta starter starter of capcity upto 30 HP and supply and fix star delta starter suitable for submersible pump set of capacity upto 30 HP, make as per the existing or as specified by the Engineer-in-charge.
Supply only MBBR Media virgin PP PU stabilized, Black colour, Media height-16mm, Media Dia-22mm, Structure-Cylindrical with external fins
M&L in repair for Tube settler media, MOC-PVC, Thickness-1.1mm, cross section size 75mm x 60mm, laying at angle of 60 degree including taking down old tube settler media all as directed by Engineer-in-Charge
Supply only Sodium Hypochlorite 12% solution
Replacement of coarse bubble diffuser, Material-EPDM, Silicon, Bubble dia-3mm all as per sample. Make: BIOTECH or equivalent as approved by GE
Replacement of fine bubble diffuser, Material-SS 304, Bubble dia-3mm all as per sample Make: BIOTECH or equivalent as approved by GE
Cross arms, bracing supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts in any shape or size as indicated or as directed inclusive of one primer coat or red oxide, one under coat and finishing coat of aluminium paint all as specified and as directed.
M&L in repair MCCB 3 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as directed
S&F CI specials such as bends (any type, radius and angle) Tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces, single branch, Y junction, double branch cross (all sockets or socket and spigot or all flanged or flanged and other socket or spigot) collars, caps and plugs etc . upto 150 mm dia as in repairs and all as per IS complete all as specified and as directed by Engineer-in-charge.
M&L for Submersible Copper cable 3 core 4 Sqmm PVC insulated all as directed.
M&L for Submersible Copper cable 3 core 6 Sqmm PVC insulated all as directed.
M & L for clearing cloged sewage from pipes of any size by dismentaling the pipe from any source of suction and discharge and refixing the same at existing position and checking the same for leak proof joints including relacing rusted nut bolts and arresting the leakages by welding and replacing CI/GI/MS specials.
Supplying, installation, testing and commissioning of 80 mm (3 inch) Butterfly Valve, PN 16 rating, cast iron body with ductile iron disc, EPDM seat, stainless steel shaft, lever/worm gear operated, complete as specified and directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of 15 mm brass impact sprinkler, full circle/part circle adjustable type, heavy duty with ½ inch BSP male threaded connection, corrosion resistant spring and bearing, suitable for working pressure 2.5 – 5.0 kg/cm², discharge capacity 0.25–0.75 lps, with adjustable jet breaker and range control, complete with all fittings as required, all as specified and directed by Engineer-in-Charge
Servicing and preventive maintenance of Analog / Addressable type Multi-Sensor Fire Alarm System comprising the following: dismantling and cleaning of all detectors, checking and ensuring the proper operation of power supply modules, battery backup, control panel wiring and connections; carrying out minor repairs to power cords and cables as required; diagnosing and rectifying all faults indicated by the panel; restoring the system to normal working condition; and carrying out functional test as directed by the Engineer-in-Charge.
Servicing / Repair of Fire Extinguishing System (Novec-1230 Gas Suppression Type) including removal, inspection, and reinstallation of cylinders, checking of pressure levels, servicing or replacement of control panel, detection modules, hooters, release valves, and associated accessories; reconnecting, testing, and recommissioning the system to ensure full operational performance of the gaseous suppression arrangement; all works complete as specified and directed by the Engineer-in-Charge.
Taking down unserviceable detector and Supply and fixing multisensor (smoke & heat) addressable type detector suitable as per existing make / fire alarm system complete all as specified and directed. Make: Ravel/EST-3/Notifire/ Honey well.
Taking down unserviceable MCP and Supply and fixing Mannual Call Point ( MCP) addressable type suitable as per existing make / fire alarm systemcomplete all as specified and directed. Make: Ravel/EST-3/Notifire/ Honey well.
Taking down unserviceable Sounder and Supply, install testing and commissioning of Addressable electronic sounder cum strobe suitable as per existing make / fire alarm system complete all as specified and directed. Make: Ravel/EST-3/Notifire/ Honey well.
Taking down unserviceable detector and Supply and fixing multisensor (smoke & heat) conventional type detector suitable as per existing make / fire alarm system complete all as specified and directed. Make: Ravel/EST-3/Notifire/ Honey well.
Taking down unserviceable MCP and Supply and fixing Mannual Call Point ( MCP) conventional type suitable as per existing make / fire alarm systemcomplete all as specified and directed. Make: Ravel/EST-3/Notifire/ Honey well.
Taking down unserviceable Sounder and Supply, install testing and commissioning of conventional electronic sounder cum strobe suitable as per existing make / fire alarm system complete all as specified and directed. Make: Ravel/EST-3/Notifire/ Honey well.
Supply and Refilling of FK 1230 (FK-5-1-12) Agent in cylinder of Gas suppression systems complete all as specified and directed by Engr-in-Charge
Supply and replacing Valve Re-build Kit from the Gas suppression systems complete all as specified and directed by Engineer - in -Charge
Supply and replacing Refilling Kit from the Gas suppression systems complete all as specified and directed by Engineer - in -Charge
Supply and replacing PESO appoved MS Valve of Size 50mm dia from the Gas suppression systems complete all as specified and directed by Engineer - in -Charge
Dismantling the Gas cylinder by removing the necessary connection from Gas release panel, trasnporting the cyclinder to authorised wksp of OEM after making suitable wrapping and packing for carrying out necessary leak proof and re-installation of Gas cyclinder after getting repaired and necessary gas filling , testing, commissioning complete all as specified and directed by Engineer in Charge. Note. Re-filling of Gas ( FK 1230 (FK-5-1-12) Agent) will be measured and paid separately.
Taking down UNSV battery from the Fire Alarm control Panel and Supply and fixing new Battery of 12 Volt DC lead acid battery 8 AH complete all as specified and directed by Engineer in charge Make : Exide/ Universal/Amron
Servicing of Solar Power Plant of 70 KW for the following:- 1 Monitoring 2 Cleaning 3 Inspections 4 Preventative Maintenance The annual maintenance service includes all the tasks outlined in the Scope of Work, including visual inspections, performance monitoring, electrical system maintenance, cleaning, and structural integrity checks complete all as directed by Engineer-in-charge.
Supply, installation, testing and commissioning of Loop Card for Addressable Fire Alarm Control Panel, suitable for connecting up to 254 addressable devices, designed for direct plugging into the slot provided in the motherboard of the panel, including all accessories, fixing arrangements, interconnections and making the system fully operational, complete as specified and directed by the Engineer-in-Charge
Supply, installation, testing and commissioning of RE-120GR Agent Release Panel, feature-packed control unit designed for dual function of fire detection and controlled release of gaseous suppression agent, having two independent detection circuits and one agent release circuit with programmable options, including necessary accessories, fixing arrangements, interconnections, and complete in all respects as specified and directed by the Engineer-in-Charge
Repairing / Replacing of Main Mother Board of Fire Alarm Control Panel including dismantling of defective board, supply and installation of compatible OEM recommended motherboard, testing, programming, configuration with existing loop devices, and commissioning the system to restore full operational status, as required at site complete all as specified and directed
Supply, installation, testing and commissioning of Power Supply Module (SMPS) suitable for Fire Alarm Control Panel, including wiring connections, DC output configuration, and testing on full load, complete as required and all as directed by Engineer-in-charge.
Supply and fixing of Display and Control Module for Fire Alarm Control Panel, consisting of LCD/LED indicators, status lamps, control switches (reset, silence, evacuate, acknowledge), including programming and testing, complete as specified and directed by Engineer-in-charge.
SRI SAI RAM ENTERPRISES (BID ID -3502767)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
8861ps.pdf
Tender Documents • 0.73 MB
BOQ_828861.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .