Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.4 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | 1 | Accepted-AOC beingL1 | |
| 2 | 2₹7.3 L+₹73,725 (11.3%)Rejected-Finance | 2 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 3 | 3₹7.9 L+₹1.4 L (20.8%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | 3 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 4 | 4₹9.1 L+₹2.5 L (38.6%)Rejected-Finance E 37 CWE AF SOUTH BANGALORE A I A II B I | BENGALURU URBAN | KARNATAKA | 560001 | 4 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in required category |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
21 Feb 2024, 6:00 pmClosed
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
MAINT AND REPAIRS TO STREET LIGHTS SECURITY LIGHT SOLAR LIGHTS OF ANY TYPE, GARDEN LIGHTS POST TOP LANTERN AND CONNECTED ITEMS AT AFAC UNDER AGE (I) (AF) COIMBATORE.
2024_MES_639102_1
8960_E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Coimbatore
Class-E category-b(i) (see NIT for detail)
8 documents required · 8 mandatory
₹500
AGE I AF Coimbatore
₹18,000
Yes
29 Feb 2024
25 Jan 2024
26 Feb 2024
25 Jan 2024
21 Feb 2024
9 Feb 2024
25 Jan 2024 - 8 Feb 2024
Amount
M&L for taking down the unserviceable street light/flood light/Post top lanter/Garden light fitting of any type & capacity from its original location by unscrewing the nuts, bolts, washers etc and and carrying to work shop for repair/replacement and re-fixing the same position complete all as specified and directed by the Engr-in-charge. Note: - (1) All T&P required shall be provided by the contractor. Minor spare parts such as connector , nut, bolts, washers, etc required for repair/replacement shall deemed to be included in quoted rates
Taking out care fully old existing LT cable of any size from the trenches by removing bricks and keeping cable & bricks aside for re-use or for taking credit complete all as specified and directed
Supply only LED Driver suitable for Street light for capacity 25- 40 W complete all as specified and directed
Supply only LED Driver suitable for Street light for capacity 45-90 W complete all as specified and directed
Supply only Energy saving and environmental friendly long life 45W LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening separate drive compartment with IP66 and impact resistance of IK08 complete all as specified and directed Make : Havells ENDURASUNDOWNSL45WLED 765 PAS YBOPC / Bajaj /Crompton or Equivalent
Supply only LED Driver suitable LED Flood light for capacity 100-150 complete all as specified and directed
Supply only Energy saving and environmental friendly long life ecxclusive innnovative die-cast aluminium IP66 flood light 150W LED Make : Havells JETAIRSFLS150WLED757P2AV2WBLTG /Bajaj/Crompton or Equivalent
Supply only post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
Material only in repair for unserviceable post top lantern LED type of any watt and size 230 watt volts AC outdoor type with decorative post top by replacing wornout driver, LED lamp, flexible cable and make the light in operational condition complete all as specified and directed.
M/L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, multi stranded, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core complete all as specified and directed
M/L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, multi stranded, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 core complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out in Hard/dens soil for laying of UG cables complete all as specified and directed
Returning, filling in, including removing vegetation roots, sieving, spreading, leveling, upto 18 cm thickness for cable cushioning with the soil excavated under item No.1 above.complete all as specified and directed
Removing excavated materials (soils) to a distance not exc 50m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed
Supply and laid well burnt bricks sub-class 'B' designation 75 for cable protection, brick shall be laid dry flat as width of brick eqals to the length of cable and the gap between adjacent brick shall not exceeded 10 mm, complete all as specified and as directed.
M&L for riddled earth filling in trenches above and below the cable as in cable protection.complete all as specified and directed. Note:- Punned thickness shall be mesured and paid.
M&L for horizontal boring under road/path/hard standing suitable for inserting GI pipe 80 mm dia under the road/path/hard satnding complete and the depth of horizontal bore shall not be less than 50 CM below the normal ground level by trench less technology usin necessary machine complete all as specified and directed
M&L for GI pipe 80 mm dia light grade with all fittings for cable protection laid under road/path/hard standing or fixed with wall/pole etc complete all as specified and directed
S&F Cable junction box IP66 halogen free and weather proof for out door installation made of thermoplastic material of size 167mm x125mm x 82 mm, suitable for upto 16 sqmm cable entry & cable out opening , fitted with 01 Nos MCB , SPN 32 Amps for incomer and 01 Nos MCB SP,06 Amps as out going complete internally pre-wired fitted with terminals,connectors etc and including neccessary fixing arrangement such as nuts, bolts, washers, MS clamps made of 20x5 mm and painting etc & making connection complete. Make: Hensel, Cat No. KF1616B or equivelent in Sintex, Array
M&L for GI bracket of size 32-50 mm dia and 1.20 Mtr long GI pipe light grade bent to shape ncluding neccessary fixing arrangement such as nuts, bolts, washers, MS clamps made of 20x5 mm and painting etc & making connection complete
Laying only Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade With Grey cement and pigment
S&F in replacement of Digital timer switch with astonomical function for switching on/off lights 2 out output 16A and other electrical deices according to the rising/setting of the sun for street light and making connetion complete as in position and as directed by Engr-in-Charge Make : Legrand (DX3 time switches) /Havells/Bajaj
M&L for painting of street light pole of 9 mtr long including preparation of old paint surface, painting two coats of aluminium paint over a coat of red-oxide then writing pole number over black strip complete all as specified and direted please. Note :- Painting to be carried after removing brackets and two holes to be made for insertion of hanging wire
S&F in replacement of PVC insulated and FR PVC round copper conductor (flexible) 1100V 1.0 Sqm 3 core and making connetion complete as in position and as directed by Engr-in-Charge
S&F in replacement of solar street light with motion sensor with inbuilt battery of 7 W lumen out put 1000 complete all as specified and directed Make : Philips BRC010LED10/765
M&L for GI pipe of 32-50 mm dia GI pipe light grade bent to shape ncluding neccessary fixing arrangement such as nuts, bolts, washers, and painting etc from Junction box to copping connection complete all as specified and directed
M&L for cross arms, bracking supports clamps and bacl plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed
M&L for LED Bollard light in IP 65 with robust design and efficient light distribution 10 W complete with necessary PCC work complete all as specified and directed
p.chinnasamy
R K BUILDERS
SEMBA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .