| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAdmitted-Fee/PreQual/Technical/Finance | ₹3.1 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | K. M. ENTERPRISE L1 |
|---|---|---|---|---|
| 1.00 | S/F of copper refrigerant line 1/2" & 1/4" (nominal size) including providing thermal insulation neoprene rubber tube for 1/2" & 1/4" on copper pipe including wrapping with non adhesive PVC tape, S/Laying 4x2.5 sq.mm Copper control cable etc as required. | 30 | Mtr | 1,44,000 ₹1,69,920 Lowest |
| 2.00 | Supplying & Charging refrigerent (R-410/R32) in existing AC unit as per manufacturer recommendations ater proper vacummization, leaktestung, complete as required | 4 | kg | 8,400 ₹9,912 Lowest |
| 3.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
a) 4x 4 Sqmm+2x4 Sqmm | 5 | Mtr | 4,750 ₹5,605 Lowest |
| 4.00 | Supplying and fixing of PVC trunking for covering the AC copper pipe, cable etc as reqd.
(a) 100mm x 50mm | 36 | Mtr | 79,200 ₹93,456 Lowest |
| 5.00 | Supplying & fixing of following 25 mm dia CVPC pipe for draining out the condensated water from the indoor AC units, complete as reqd. | 36 | Mtr | 10,800 ₹12,744 Lowest |
| 6.00 | Supplying & fixing of AC Controller for operating 4 Units in desired time and sequence, with monitoring of room temperature for its operation, including making all electrical connections , etc. as required. | 1 | Nos | 19,500 ₹23,010 Lowest |
Tender Value
₹3.0 L
EMD Value
₹6,000
Closing Date
13 Jul 2026, 3:00 pmClosed
Execuitve Engineer (E)
BSNL ED SVP
Providing Electrical Infrastructure in defence room at CANI, CLS Building, Port Blair (SW. Providing wiring for AC Units, extended copper pipe, and allied switchgears)
2026_BSNL_282557_1
17/ED/SVP/2026-27, dated 01.07.2026
Open Tender
Electrical Works
Item Rate
30 days
Sri Vijaya Puram
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹6,000
Yes
14 Jul 2026
1 Jul 2026
14 Jul 2026
1 Jul 2026
13 Jul 2026
1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S/F of copper refrigerant line 1/2" & 1/4" (nominal size) including providing thermal insulation neoprene rubber tube for 1/2" & 1/4" on copper pipe including wrapping with non adhesive PVC tape, S/Laying 4x2.5 sq.mm Copper control cable etc as required. | 30 | Mtr | - | - |
| 2 | Supplying & Charging refrigerent (R-410/R32) in existing AC unit as per manufacturer recommendations ater proper vacummization, leaktestung, complete as required | 4 | kg | - | - |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
a) 4x 4 Sqmm+2x4 Sqmm | 5 | Mtr | - | - |
| 4 | Supplying and fixing of PVC trunking for covering the AC copper pipe, cable etc as reqd.
(a) 100mm x 50mm | 36 | Mtr | - | - |
| 5 | Supplying & fixing of following 25 mm dia CVPC pipe for draining out the condensated water from the indoor AC units, complete as reqd. | 36 | Mtr | - | - |
| 6 | Supplying & fixing of AC Controller for operating 4 Units in desired time and sequence, with monitoring of room temperature for its operation, including making all electrical connections , etc. as required. | 1 | Nos | - | - |
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.51 MB
BOQ_329641.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .