| Sl No | Description | Qty | Unit | rbs engineering L1 | AR POWER AUTOMATION L4 | exSel Corporation L3 | AR Electricals & Hardware L2 |
|---|---|---|---|---|---|---|---|
| 1.00Details of Work/Supply. | |||||||
| 1.01 | Supply of License for SCADA (ALSTOM-DS agile Version 5.0.4.7) server :- SCADA application software server as per site requirements. | 1 | No. | 4,49,900 ₹4,49,900 Lowest | 6,00,000 ₹6,00,000 | 5,00,000 ₹5,00,000 | 4,50,400 ₹4,50,400 |
| 1.02 | Poviding & Installation of New Gateway for remote data configuration to SLDC/ALDS with Licence and its application software as per following specifications: (1) Multiple- master communication capability. (2) Support IEC60870-5-101/103/104, DNP3 serial/TCP MODBUS RTU/ ASCII/ TCP, IEC62056-DLMS, IEC61850, SNMP, SNTP, MQTT (3) Data Point support:- 5000 (4) Port Connectors:- 4 serial (RS22/485) and 2 Ethernet. (5) Power Supply (AC-DC) 85-265V AC 50-60 Hz, 100-370V DC. (6) Reliability:- IEC61850-3 complitanat Hardware,DNV certiied IEC61850 server, HOT- Standby redundancy specific Synchronisation (IEC104/DNP3.0 etc) Suitable for existing ALSTOM make SCADA system installed at 132KV S/S Patara, including Installation work and all softwrae configuration and its Testing as per site condition and all other associated work required to comple the job satisfactorily. | 1 | No. | 2,24,500 ₹2,24,500 Lowest | 2,99,000 ₹2,99,000 | 3,50,000 ₹3,50,000 | 2,25,000 ₹2,25,000 |
| 1.03 | Work of Gateway remote data configuration to SLDC (Sending Data to remote station on protocol at IEC-101). Work includes: (a) Complete checking of SAS gateway panel including artchitecture and settings.(b) Programming and Configuration of gateway with addresses & settings (provided by client) to link from Sub-Station to Data centre- Lucknow. (c) Complete Testing of SAS gateway and complete Data communication & Validationb b/w SubStation to Data centre, Lucknow. (Firm shall ensure proper uninterrupted Data Transmission to ALDS for atleast Six months free of cost.) | 1 | Job | 74,900 ₹74,900 Lowest | 1,50,000 ₹1,50,000 | 90,000 ₹90,000 | 75,000 ₹75,000 |
| 1.04 | Work of Gateway remote data configuration to ALDS (Sending Data to remote station on protocol at IEC-104). Work includes: (a) Complete checking of SAS gateway panel including artchitecture and settings. (b) Programming and Configuration of gateway with addresses & settings (provided by client) to link from Sub-Station to Data centre- Modipuram. (c) Complete Testing of SAS gateway and complete Data communication & Validationb b/w SubStation to Data centre, Modipuram. (Firm shall ensure proper uninterrupted Data Transmission to ALDS for atleast Six months free of cost.) | 1 | Job | 74,900 ₹74,900 Lowest | 1,50,000 ₹1,50,000 | 90,000 ₹90,000 | 75,000 ₹75,000 |
| 1.05 | Repairing of hardware of existing HMI (PC-1 & PC-2) and Restoration of all healthy 132 & 33 KV feeders real time Data at Local SCADA HMI as perviously running on the SCADA installed at 132KV S/S Patara. | 2 | Job | 15,000 ₹30,000 Lowest | 30,000 ₹60,000 | 25,000 ₹50,000 | 15,500 ₹31,000 |
| 1.06 | Configuration and commissioning of 132/33 KV Substation in SCADA:- Work Included as SLD generation for Feeder bay in existing HMI , remote operation from HMI , Events / Alarms generation and report configuration , interlocks and soft logics configuration and its testing if any . Hot and stand by server configuration. | 1 | Job | 5,49,990 ₹5,49,990 Lowest | 6,00,000 ₹6,00,000 | 5,50,000 ₹5,50,000 | 5,50,000 ₹5,50,000 |
| 1.07 | Configuration of relay for making CID files for IEC61850- compatible as per requirement :-Work include configuration of relay as per the signal list /drawing verifying the signal from switch ward to panel with operation of each equipment from BCU of all 132 & 33 KV feeders installed at 132 KV S/S Patara and satisfying the logic as per the scheme. (Work also includes Checking operation of CBs from remote SCADA HMI succesfully in presence of Supervising Engineer and finally submitting report for Data checking duly signed in 03 set.) | 17 | Job | 10,000 ₹1,70,000 | 28,000 ₹4,76,000 | 28,000 ₹4,76,000 | 9,990 ₹1,69,830 Lowest |
| 1.08 | Supply & Installation of Patch Cords, RJ45/Cat5 cables per the site requirement. Work Includes Checking and Troubleshooting of Communication Architecture of Fibre Optic Ring system to make SCADA system operational, including splicing of fibre optics patch cord of damage fibrs is any required under the jurisdiction of Supervising Engineer. | 1 | Lot | 70,000 ₹70,000 Lowest | 75,000 ₹75,000 | 75,000 ₹75,000 | 70,500 ₹70,500 |
| 1.09 | Repair & Rectification of the 2 KVA UPS system along with batteries installed for SCADA HMI at 132KV S/S Patara. | 1 | Job | 12,000 ₹12,000 Lowest | 25,000 ₹25,000 | 25,000 ₹25,000 | 12,500 ₹12,500 |
Tender Value
₹16.6 L
EMD Value
₹19,590
Closing Date
3 Oct 2025, 3:00 pmClosed
SE ETC Banda
SE ETC Office, 220 KV S/S Tindwari Road, Banda
WORK FOR RECTIFICATION OF DEFFECT IN EXISTING ALSTOM MAKE SCADA SYSTEM AND CONFIGURATION OF GATEWAY FOR DATA TRANSMISSION TO SLDC AND SUB SLDC AT 132 KV SUB STATION PATARA, HAMIRPUR, UNDER ETD HAMIRPUR.
2025_UPTCL_1071898_2
T-43/ETC(B)/2025-26
Open Tender
Electrical Works
Item Rate
30 days
Banda
As per tender document.
2 documents required · 2 mandatory
₹590
As per NIT
₹19,590
10 Oct 2025
20 Sept 2025
4 Oct 2025
20 Sept 2025
3 Oct 2025
20 Sept 2025
Amount
Details of Work/Supply.
Supply of License for SCADA (ALSTOM-DS agile Version 5.0.4.7) server :- SCADA application software server as per site requirements.
Poviding & Installation of New Gateway for remote data configuration to SLDC/ALDS with Licence and its application software as per following specifications: (1) Multiple- master communication capability. (2) Support IEC60870-5-101/103/104, DNP3 serial/TCP MODBUS RTU/ ASCII/ TCP, IEC62056-DLMS, IEC61850, SNMP, SNTP, MQTT (3) Data Point support:- 5000 (4) Port Connectors:- 4 serial (RS22/485) and 2 Ethernet. (5) Power Supply (AC-DC) 85-265V AC 50-60 Hz, 100-370V DC. (6) Reliability:- IEC61850-3 complitanat Hardware,DNV certiied IEC61850 server, HOT- Standby redundancy specific Synchronisation (IEC104/DNP3.0 etc) Suitable for existing ALSTOM make SCADA system installed at 132KV S/S Patara, including Installation work and all softwrae configuration and its Testing as per site condition and all other associated work required to comple the job satisfactorily.
Work of Gateway remote data configuration to SLDC (Sending Data to remote station on protocol at IEC-101). Work includes: (a) Complete checking of SAS gateway panel including artchitecture and settings.(b) Programming and Configuration of gateway with addresses & settings (provided by client) to link from Sub-Station to Data centre- Lucknow. (c) Complete Testing of SAS gateway and complete Data communication & Validationb b/w SubStation to Data centre, Lucknow. (Firm shall ensure proper uninterrupted Data Transmission to ALDS for atleast Six months free of cost.)
Work of Gateway remote data configuration to ALDS (Sending Data to remote station on protocol at IEC-104). Work includes: (a) Complete checking of SAS gateway panel including artchitecture and settings. (b) Programming and Configuration of gateway with addresses & settings (provided by client) to link from Sub-Station to Data centre- Modipuram. (c) Complete Testing of SAS gateway and complete Data communication & Validationb b/w SubStation to Data centre, Modipuram. (Firm shall ensure proper uninterrupted Data Transmission to ALDS for atleast Six months free of cost.)
Repairing of hardware of existing HMI (PC-1 & PC-2) and Restoration of all healthy 132 & 33 KV feeders real time Data at Local SCADA HMI as perviously running on the SCADA installed at 132KV S/S Patara.
Configuration and commissioning of 132/33 KV Substation in SCADA:- Work Included as SLD generation for Feeder bay in existing HMI , remote operation from HMI , Events / Alarms generation and report configuration , interlocks and soft logics configuration and its testing if any . Hot and stand by server configuration.
Configuration of relay for making CID files for IEC61850- compatible as per requirement :-Work include configuration of relay as per the signal list /drawing verifying the signal from switch ward to panel with operation of each equipment from BCU of all 132 & 33 KV feeders installed at 132 KV S/S Patara and satisfying the logic as per the scheme. (Work also includes Checking operation of CBs from remote SCADA HMI succesfully in presence of Supervising Engineer and finally submitting report for Data checking duly signed in 03 set.)
Supply & Installation of Patch Cords, RJ45/Cat5 cables per the site requirement. Work Includes Checking and Troubleshooting of Communication Architecture of Fibre Optic Ring system to make SCADA system operational, including splicing of fibre optics patch cord of damage fibrs is any required under the jurisdiction of Supervising Engineer.
Repair & Rectification of the 2 KVA UPS system along with batteries installed for SCADA HMI at 132KV S/S Patara.
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
AR Electricals & Hardware (BID ID -5579591)
exSel Corporation (BID ID -5577190)
AR POWER AUTOMATION (BID ID -5576752)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .