| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-Finance | L1 | Accepted-Finance Will be accepted if found reasonable | |
| 2 | L2₹13.9 L+₹2.2 L (19.2%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹16.0 L+₹4.3 L (37.2%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹16.7 L+₹5.0 L (43.2%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹18.0 L+₹6.3 L (53.6%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹15 L
Closing Date
16 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GOLCONDA
GE GOLCONDA LANGERHOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
REPAIR AND MAINT OF SPLIT WINDOW ACs DESERT COOLER REFRIGERSTORS AND DEEP FREEZERS UNDER GE GOLCONDA
2021_MES_476318_1
CA No. GE/Gol/ 41 of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE GOLCONDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GOLCONDA
Exempted
19 Oct 2021
18 Sept 2021
18 Oct 2021
18 Sept 2021
16 Oct 2021
2 Oct 2021
18 Sept 2021 - 30 Sept 2021
60 days
Amount
SPLIT / WINDOW TYPE AC
Taking down carefully old burnt/unserviceable compressor unit of 1.0 ton capacity window type/Split type AC and replacing the same with New compressor including necessary accessories and mounting materials, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete for any make of AC all as directed. Make : Kirloskar / Voltas/ LG/OEM
All as per item No : 2 above but for Window/Split type AC 1.50 Ton Capacity
All as per item No : 2 above but for Window/Split type AC 2.00 Ton Capacity Note for item 2 to 4:- Rate quoted shall be inclusive of R-22 refrigerant gas charging, testing and commissioning.
S & Fix Relay assembly and connecting with necessary wiring complete suitable for Window/Split type of AC 1.0/1.5/2.0 Ton Capacity and taking out the old unserviceable one. Make : Shriram /Renutraul / Voltas
S & Fix Over load protector complete suitable for Window/Split type AC of 1.0/105/2.0 Ton Capacity including removal of old Un Serviceable. Make : Shriram /Renutraul / Voltas
S & Fix Thermostate set complete for window/split type AC of any make/model of Capacity 1.0/1.5/2.0 Ton including removing the old unserviceable Make – Renutraul/Annapurna/Usha
S & Fix Blower fan motor, with fixing arrangement complete operating on 215 / 240 Volts, single phase AC supply, multi speed suitable for Window AC 1/1.5/2.0 Ton capacity including taking out the old one. Make : OEM
Rewinding of outdoor fan motor with same guage and turns and weight of copper enameled wire and replacement of bearing, testing and commissioning for 1.0/1.5/2.0 Ton split type AC of any make/ model complete all as directed.
S & Fix capacitor of 36/45 MFD for Window/Split type AC's all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON
S & Fix capacitor of 50/60 MFD for Window/Split type AC's all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON
S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for window /Split type AC 1 Ton to 2 Ton capacity and taking out the old unserviceable one.
S & Fix Wiring kit for window type AC of 1.0/1.5/2.0 Ton capacity with copper wire PVC insulated single core of size1.5 sq mm, clips, terminal connector etc complete all as directed and taking out the old unserviceable one.
All as per item No : 13 above but Split type AC of capacity 1.0/1.5/2.0 ton .
Cleaning the unit with CTC except evaporator and condensor and leak testing the system with Nitrogen gas and detecting the leak and repairing, brazing and sealing the leakage including charging the refrigerant R-22 gas to the required pressure and weight of gas for 1.0/1.5/2.0 Ton capacity window type ACof any make complete all as directed Note :- Gas charging will be measured separately against relevant item of this schedule.
All as per item No : 16 above but Split type AC of capacity 1.0/1.5/2.0 ton .
Servicing of split type AC units of 1/1.5/2.0 ton capacity, cleaning of the evaporator coils externally with Caustic Soda / Chemical to remove the dust particles deposited on the cooling coil, cleaning of the condensing units to reduce the discharge pressure with the Caustic Soda / Chemical and testing complete all as directed.
Servicing of window type Air Conditioners of capacity 1/1.5/2.0 ton capacity, cleaning of the evaporator coil externally with Cautic Soda / chemical to remove the dust particles, cleaning of the filters and testing complete all as directed.
S & Fix Air Filter to the window /Split type Air Conditioners of 1/1.5 /2.0 Ton capacity and taking out the old unserviceable one.
S & Fix Evaporator coil, including connected brazing welding work and provn of refrigerant suction/discharge line suitable for Window AC / Split Type AC 1.0/1.5 / 2.0 TR capacity including removing the unserviceable evaporator coil from the existing position all as directed.
S & Fix new remote control assembly for split type AC 1.5 /2.0 TR capacity including removing of the old unserviceable complete all as directed.
Taking out the unserviceable condensor coil and S & F new condensor coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length for window AC/Split type AC 's of 1.5 Ton capacity all as directed including taking down old U/S condenser coil.
S & Fix Front grill for Window AC as existing make/model and taking out the old unserviceable one.
S & Fix indoor blower motor for split type AC of capacity 1.5/2.0 Ton as per existing model complete all as directed and taking out the old unserviceable one. Make : OEM
S & Fix PVC drain pipe 25 mm for rectifying water leakage from AC units complete all as directed and taking out the old unserviceable one.
S & Fix copper tube of size 3/8, 5/8 inch dia includng necessary soldering and connecting and testing, between indoor to out door units of split type AC 1.5/2.0 Ton complete all as directed and taking out the old unserviceable one.
All as per Item No-27 above but size of copper tubing 1/2, 1/4 inch dia complete all as directed.
S & Fix insulation felt for split type AC 1.5 / 2.0 Ton copper tube inlet/outlet to out door unit up to 3 mtr in length complete all as directed.
Taking out unserviceable 1 Pole contactor from split AC and replacing the same with new contactor suitable for 240V,50Hz coil complete all as directed and taking out the old unserviceable one.
S & Fix Oscillation motor for the indoor unit of the split type AC of 1.5/2.0 Ton capacity complete all as directed and taking out the old unserviceable one.
Taking out unserviceable dummy nuts from the split AC units and S & Fix new Brass Dummy / Flare nuts of existing size complete all as directed.
S & Fix Fan blade for 1.5/2 Ton capacity window/Split type ACs as per existing size/ model complete all as directed and taking out the old unserviceable one.
Taking down UNSV Indoor unit of Split type AC of 1.5 TR capacity any make, model and S & F new indoor uint of same capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as directed. Make : OEM
Repairs to PCB of split type AC 1.5 /2.0 TR capacity including of replacement of electronic spares complete all as directed.
WATER COOLER
Taking out burnt / unserviceable compresser from existing water cooler compressor and S & F new sealed compressor unit including necessary welding/brazing/pressure testing withe refregerant after charging leak proof condition and testing complete for water cooler of capacity 40/60 ltrs. Note:- Rate quoted shall be inclusive of R-22 refrigerant gas charging, testing and commissioning. Make : kirloskar/Shriram/Voltas/OEM
Taking out burnt / unserviceable compresser from existing water cooler and S & F new sealed compressor unit including necessary welding/brazing/pressure testing withe refregerant after charging leak proof condition and testing complete for water cooler of capacity 80/100 ltrs. Note:- Rate quoted shall be inclusive of R-22 or R-134a Refrigerant gas charging, testing and commissioning. Make : kirloskar/Shriram/Voltas/OEM
S & F relay assembly and connecting with necessary wiring complete for water cooler of 40/60/120 ltrs capacity and taking down unserviceable one Make:- Renutraul/Annapurna/Usha
S & Fix Over load protector complete suitable for Water cooler of capacity 40/60/150 Ltr including removal of old Un Serviceable Make – Renutraul/Annapurna/Usha
S & Fix starting capacitor of 60/80 MFD for water cooler all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON
S & Fix Thermostate set complete for Water cooler of any make/model/capacity including removing the old unserviceable Make – Danfoss / Renutraul/Annapurna
S & Fix capacitor of 6/10 MFD for water cooler/ Refrigerator all as directed and taking out the old unserviceable one. Make- CONCAP BHEL/TIBCON
S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Water cooler capacity 40/80/120/150 ltrsand taking out the old unserviceable one.
Cleaning the gas system with CTC, rectification of leakages, M&L Charging gas with refrigerant gas incl cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for Water cooler 40 /60/150 ltrs capacity Note :- Gas charging will be measured separately against relevant item of this schedule.
S & Fix Connecting lead PVC sheathed 3 core copper wire cable, 4 sq mm 3 metre long with plug top 15 Amps for water cooler/Deep Freezer and taking out the old unserviceable one.
S & Fix PVC Float assembly to the water coolers including removing of the unserviceable from the existing position all as directed.
S & Fix Tap assembly to the water coolers of SS make including removing of the damaged unserviceable existing tap from the existing position all as directed. Make:JAISON
S & Fix Water cooler condenser suitable for 40/60 ltrs cooling capacity including necessary welding/brazing/pressure tesing with Nitrogen Complete and taking out the old unserviceable one.
S & Fix Water cooler condenser suitable for 80/120 ltrs cooling capacity including necessary welding/brazing/pressure tesing with Nitrogen Complete and taking out the old unserviceable one.
S & Fix PVC drain pipe 40 mm dia for water cooler complete all as directed and taking out the old unserviceable one.
REFRIGERATOR
Taking out burnt / unserviceable compressor from existing refrigerator and S & F new sealed compressor unit including necessary welding/brazing/pressure tesing with Nitrogen afer charging leak proof condition and testing complete for refrigerator of 165 ltrs capacity. Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning. Make : kirloskar/Shriram/Voltas/OEM
S & F relay assembly and connecting with necessary wiring complete for Refrigerator of 165/286 ltrs capacity and taking down u/S one Make:- LG/Godrej /Whrilfool
All as per item No :53 above but 310 ltrs capacity
S & Fix Thermostate set complete for Rifrigerator of any make/model/capacity including removing the old unserviceable Make – Danfoss / Renutraul/Annapurna
S & Fix Over load protector complete suitable for Refrigerator of any make/ model of 165/ 280/ 310 Capacity including removal of old Un Serviceable :-Make : Shriram /Renutraul / Voltas
S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Refrigerators of capacity 280/310 ltrs and taking out the old unserviceable one.
Cleaning the gas system with CTC, rectification of leakages, M&L Charging gas with refrigerant gas incl cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for refrigerator 165 /310 ltrs capacity Note :- Gas charging will be measured separately against relevant item of this schedule.
S & Fix Connecting lead PVC sheathed 3 core copper wire cable, 4 sq mm 3 metre long with plug top 15 Amps for water cooler/Deep Freezer and taking out the old unserviceable one.
S & Fix Magnetic door gasket for refrigerator of existing size and make including taking out the old gasket of refrigerator of capacity 165 / 286 / 310 ltrs.
S & Fix fan blade for Frost free motor of Refrigerator capacity 210/280/310 ltrs and taking out the old unserviceable one.
Removing burnt out fan motor of frost free Refrigerator/deep freezer motor and refixing with new one all as directed
Removing the burnt out Glass Heater of frost free refrigerator and fixing with new one all as directed.
S & Fix Refrigerator freezer box with door of capacity 165 Ltrs including necessary welding/brazing/pressure tesing with Nitrogenof any make and taking out the old unserviceable one.
S & Fix Refrigerator freezer box with door of capacity 280 Ltrs including necessary welding/brazing/pressure tesing with Nitrogenof any make and taking out the old unserviceable one.
S & Fix Refrigerator door handles suitable for any capacity and any make and taking out the old unserviceable one.
S & Fix metal fuse for refrigerator of any capacity and taking out the old unserviceable one.
S & Fix Refrigerator timer for frost free refrigerator of any capacity and taking out the old unserviceable one.
S & Fix Refrigerator condenser coil of 165 ltrs capacity including necessary welding/ brazing/ pressure tesing with Nitrogen Complete and taking out the old unserviceable one.
S & Fix Refrigerator condenser coil of 310 ltrs capacity including necessary welding/ brazing/ pressure tesing with Nitrogen and taking out the old unserviceable one.
S & Fix complete wiring kit for Refrigerator of any make/model of capacity 285/310 Ltrs with copper wire PVC insulated single core of size1.5 sq mm,testing & complete all as directed. Note : any Accessaries required for this job will be measured & paid separately and taking out the old unserviceable one.
DEEP FREEZER
Taking out burnt / unserviceable compressor from existing Deep Freezer and S & F new sealed compressor unit including necessary welding/brazing/pressure testing with refrigerant after charging leak proof condition and testing complete for Deep freezers of any capacity. Note:- Rate quoted shall be inclusive of R-134a refrigerant gas charging, testing and commissioning. Make : Kirloskar/ Shriram/Voltas/Hitachi
S & Fix Over load protector complete suitable for Deep Freezer of any make/model of capacity 280/310 Ltrs including removal of old Un Serviceable Make : Shriram /Renutraul / Voltas
S & Fix Thermostate set complete for Deep Freezer of any make/model of capacity 280/310 Ltrs including removing the old unserviceable Make – Danfoss / Renutraul/Annapurna
S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for Deep Freezer and taking out the old unserviceable one.
Cleaning the gas system with CTC, rectification of leakages, M&L Charging gas with refrigerant gas incl cutting/welding/brazing and leak testing with nitrogen, testing including commissioning complete for deep freezer 280/310 ltrs capacity Note :- Gas charging will be measured separately against relevant item of this schedule.
DESERT COOLER
S & Fix capacitor of 4/5 MFD for Desert Cooler all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON
S & Fix Khas-khas screen(set of three) for desert coolers of any make and size and removing the old screen Complete.
S & Fix Fan blade of desert cooler Metallic/PVC as per existing model complete for desert coolers of any make complete for capacity 3000/4000 CUM and taking out the old unserviceable one.
S & Fix PVC water tube and distribution with 3 way PVC connection & bends assembly complete, for desert coolers of any make complete for capacity 3000/4000 CUM and taking out the old unserviceable one.
S & Fix Switch assembly as approved by the Engr-in-charge, for desert coolers of any make for capacity 3000/4000 CUM and taking out the old unserviceable one.
S & Fix in replacement of old unserviceable fan motor with new fan motors of desert coolers of 4000/5000 Cum capacity with nuts, bolts, brackets, connecting arrangeents reconnecting inclduing removing of the old U/S and testing complete all as directed. Make: OEM
S & Fix water circulating pump 1/7 HP, SP 1340 RPM having a head of 1.5 mtr suitable for desert cooler including nuts and bolts, washers brackets for fixing connecting with necessary wiring commissioning and testing and including takig down the old water circulating pump Make-OEM
S & Fix Front grill / side grill of desert cooler suitable to existing one any make/model complete for capacity 3000/4000 CUM and taking out the old unserviceable one.
STABILIZER
M&L for repairing of stabilizer of 1 KVA capacity including rewinding of Transformer,complete including replacement of PCBs, minor spare parts all as directed by Engr-in-charge.
All as per Item No-89 above but 4 KVA capacity for window /Split A/C 2.0 Ton complete all as directed.
Description all as per Item No-83 above but 5 KVA capacity for window /Split A/C 2.0 Ton complete all as directed.
Supply & charge refrigerant gas R-22 upto required level complete all as specified and directed.
Supply & charge refrigerant gas R-134a upto required level complete all as specified and directed.
S & Fix Sheet metal enclosure with single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps 'C' series, 230 Volts including removing of the old unserviceable. Make : STANDARD /INDOASIAN/C&S/OEM
S & Fix Plug top 3 Pin, 5 Amps 230 Volts including removing of the old unserviceable all as directed. Make : Anchor/Maru
All as per item No 95 here-in-before but 15 Amps.
S & Fix 3 pin industrial plug top suitable for industrial metal clad socket, single phase, 230 Volts, AC including MCB reconnecting complete all as directed and taking out the old unserviceable one. .Make- LEGRAND/C&S
SHANTI MARKETING AND SERVICES
SANJEEV CONSTRUCTIONS
STANDARD AGENCIES
MOHAMMED MUMTAZ ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .