Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹34.3 L+₹5.4 L (18.7%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹40.2 L+₹11.3 L (39.2%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹40.6 L+₹11.7 L (40.3%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹42.3 L+₹13.4 L (46.4%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
3 Apr 2023, 6:00 pmClosed
GE AF LOHEGAON
LOHEGAON, PUNE, 411032
REPAIR, REPLACEMENT AND MAINTENANCE OF DEFECTIVE ITEMS OF FLAME PROOF WIRING, FITTING, FIRE DETECTION, ALARM SYSTEM, INTERNAL ELECTRIFICATION AND MISC WORKS AT 9 BRD UNDER GE (AF) LOHEGAON AT AF STN PUNE
2023_MES_577586_2
8630/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF LOHEGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹92,000
Yes
5 Sept 2023
15 Mar 2023
4 Apr 2023
15 Mar 2023
3 Apr 2023
22 Mar 2023
Amount
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire all as directed.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc all as directed.
Taking down existing light fittings any typeafter disconnecting all electrical connection complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets all a specified and directed
One light point controlled by one switch.
One Exhaust/Wall mounted /Ceiling point controlled by one regulator/switch
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A onsame board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping 25mm size with all fittings/fixture etc fixed wall and open recessed type Plastic switch board) made of robust Synthetic material Fire Proof, Anti corrosive & shock proof ISI Marked complet for housing one 15 A Switch / sockets complete
S&F Vertical double door Distribution board TPN 4 way suitable rated busbar consisting of MCCB. 100A 4 pole 10KA - 1 No including connecting with cables/sub main wiring, fixed on surface of wall with fastners, making good the disturbed surface all as directed
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and with suitable rated bus bar including connecting with cables/sub main wiring, fixed on surface of wall with fastners, making good the disturbed surface all as directed
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with suitable rated bus bar including connecting with cables/sub main wiring, fixed on surface of wall with fastners, making good the disturbed surface all as directed
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link and with suitable rated bus bar including connecting with cables/sub main wiring, fixed on surface of wall with fastners, making good the disturbed surface all as directed
Supply and fix MCB SPN 40 Amp, 230 volt 'C' series complete
S&F MCB SP 240 volt 6 to 32 A 'C' series complete
Supply and fix switch piano flush type 5 A one way.
Supply and fix socket 2 in one 5 Pin 5 Amps.
Supply and fix switch socket combination multipurpose 3 pin 6/16 Amps.
Supply and fix switch socket combination multipurpose 3 pin 5 Amps.
Supply and fix switch piano flush type 15 Amps
Supply and fix Socket out let 2 in 1, 3 pin 5 and 15 Amps
Supply and fix Piano switch bell push type switch 5 A.
Supply and fix bell electric 230V single pole complete as directed.
S & F Fan Regulator electronic step type 100 W complete as directed
S&F angle / batten holder insulated body with back plate for batten fittings
Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Supply and fix high quality indoor Surface and wall mounted LED batten 20 Watt, provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 1.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal.
S & F MCCB, 4P, 125 Amp, 16 KA incl nacessary cable luges complete all as specified and directed
Supply and fix Energy efficient recess mounted LED panel fitting 34/36 Watt suitable for 2'x 2' grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with including 1.5sqmm 3 core copper conductor PVC insulated wire from ceiling rose to light fitting all as directed
Supply & fix heavy duty wall mounted fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V , 1200 mm sweep
S & F MCCB, 4P, 63 Amp, 16 KA incl nacessary cable luges complete all as specified and directed
Taking out carefully by disconnecting Electrical / Any type cables connectionos from existing panels/DBs of old UG cables or wires of any size and capacity with MS/GI pipes /PVC conduuit pipes of any size from existing wall after unscrewing screws, removing clamps and refixing the same properly for good layout on wall / floor by using new clamps and screws of suitable size as requred on site or as to fit in cable trays size and re-connecting all connections properly complete all as directed by Engr-in-Charge
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm
M & L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 2.5 Sq mm ( 22 / 0.3 mm ) single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping all as directed. ( Note : one run of phase one run of neutral and one run of earth wire with one run of casing capping shall be measured & paid as one length.)
Ditto all as per Ser Item No 35.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x6.0 sq. mm + 1x4.0 sq. mm earth wire
Ditto all as per Ser Item No 35.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x10.0 sq. mm + 1x6.0 sq. mm earth wire
Taking down ceiling fan single phase 240 V 1200 mm /1400mm sweep from the existing position including disconnecting supply cable from ceiling rose / connector opening ceiling fan carefully and taking out worn out/defective spare parts such as bearing/ bush shaft , blades, split pin condenser rubber reel nuts and bolts and washer etc cleaning and washing the bearings /bushs thoroughly and applying necessary lubricants etc and reassembling of ceiling fan after replacement of wornout parts and hanging in original position connecting and testing complete all as directed by Engr - in - Charge [Note :- Replacement of spares for ceiling fan shall be measured and paid seperately]
Ditto all as per Ser Item No 38.00 above but for exhaust fan 300 / 450 mm sweep complete all as specified and directed
Ditto all as per Ser Item No 38.00 above but for wall mounting fan any sweep complete all as specified and directed
Supply and fix ball bearing SKF 6201
Supply and fix ball bearing SKF 6202
Supply and fix ball bearing SKF 6203
S&F Gunmetal bush
Supply and fix capacitor 2.5 Mfd /3.15 mfd
Supply and fix capacitor 4 Mfd
Supply and fix rubber reel with nuts bolts and split pin for ceiling fan
Supply and fixing PVC unsheathed 3 core cable copper flexible wire 1 Sqmm size
M&L for rewinding of ceiling fans of 1200 / 1400 mm sweep with suitable size of copper winding wire of same gauge & number of turns complete with insulation all as directed by Engineer-in-Charge.
M&L for rewinding of exhaust fans of 300 / 380 / 450 mm sweep with suitable size of copper winding wire of same gauge & number of turns complete with insulation all as directed by Engineer-in-Charge.
M&L for rewinding of wall fans of 400 mm sweep with suitable size of copper winding wire of same gauge & number of turns complete with insulation all as directed by Engineer-in-Charge.
S&F fan clamp suitable for ceiling fan complete as directed.
S&F fan blade suitable for existing wall mounting fan / exhaust fan complete as directed
Taking down Geyser 25/50 Ltrs from the existing position including disconnecting supply cable from connector opening geyser carefully and taking out worn out/defective spare parts such as Thermostat, appratus terminal plate, glass wool, element etc cleaning and reassembling of geyser after replacement of wornout parts and hanging in original position connecting and testing complete all as directed by Engr - in - Charge [Note :- Replacement of spares for geyser shall be measured and paid seperately]
Supply and fix thermostat suitable for geyser of any make and any size as per existing one.
Supply and fix indicating neon lamps suitable for geyser of any make.
Supply and fix apparatus terminal plate assembly with provision of inlet and outlet copper tubing including nuts bolts and washers suitable for geyser of any type and any make.
Supply and fix PVC connecting pipe heavy duty 15 mm dia for inlet and outlet with brass coupling .
Supply and fix for glass wool suitable for any type and make for geyser
Supply and fix geyser element 250 V 1.5 KW suitable for 25 ltrs capacity.
S&F Syphene assembly on existing geyser suitable for 25 Ltrs Geyer
Supply and fix exhaust fan steel body 380 mm sweep copper winding complete withframe and louvers shutter, voltage 230V, 50 Hz, RPM 1200 complete all as directed
Supply & Fix in replacement Recessed pressure die-cast aluminium luminaire fitting 18W suitable for ceiling cutout dia 175 mm round dia in powder coated white finished with drop down PC diffuser with optimized heat sink for efficent heat dissiption with replaceable electronic driver
Supply & fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cables stranded conductor flat or circular 6 Sqmm
Supply & fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cables stranded conductor flat or circular 10 Sqmm
Taking down existing serviceable tube light fittings / recessed fitiing any type keep in custody and refixing the same as required on site and directed incl disconnecting and connecting connection for smooth functioning complete .
Taking down carefully after disconnecting all connections and refixing serviceable MCB DB VTPN/SPN as required and directed on site making all electrical connection and testing for smoothing functioning complete
S&F Vertical double door Distribution board TPN 4 way 200 A rated busbar consisting of MCCB. 63A 18KA - 1 No , including connecting with cables/sub main wiring, fixed on surface of wall with fastners, making good the distrubed surface all as direcected including taking down of old DB,
Supply and fix sheet metal enclosure MCB DB double door SPN 16 way 230 V with neutral link and wwith bus bar, including connecting with cables/sub main wiring, fixed on surface of wall with fastners, making good the distrubed surface all as direcected including taking down of old DB,
Supply, laying, jointing, testing and commissioning of LT under ground cable 50 Sq mm 4 core, 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles/and steel structure etc as required on site with proper size saddles and clamp laid under roads/path/ drain /culverts or enclosed in GI pipe/ fix complete all as specified
Ditto all as per Ser Item No 70.00 above but 35 Sq mm 3.5 Core complete all as directed
Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete as directed
M & L for sub main wiring with two runs of single core 2.5 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 1.5 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC conduit/capping all as directed by Engr-in-Charge. ( Note :Two runs of phase & Neutral and one run of earth wire and one run of PVC conduit/Casing capping of suitable size shall be measured & paid as one length.) all as directed including taking down of old unserviceable sub main wiring wiring complete
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x4.0 sq. mm + 1x2.5 sq. mm earth wire
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x6.0 sq. mm + 1x4.0 sq. mm earth wire
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x10.0 sq. mm + 1x6.0 sq. mm earth wire
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 4x6.0 sq. mm + 2x4.0 sq. mm earth wire
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 4x10.0 sq. mm + 2x6.0 sq. mm earth wire
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 4x16.0 sq. mm + 2x10.0 sq. mm earth wire
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x6.0 sq. mm + 1x4.0 sq. mm earth wire in suitable size of metal conduit as required on site and directed
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x10.0 sq. mm + 1x6.0 sq. mm earth wire in suitable size of metal conduit as required on site and directed
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 4x6.0 sq. mm + 2x4.0 sq. mm earth wire in suitable size of metal conduit as required on site and directed
Ditto all as per Ser Item No 73.00 above but S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 4x10.0 sq. mm + 2x6.0 sq. mm earth wire
S&F Hot Dip galvanised solid perforated cable tray and cover of width 450 mm, depth 100 mm and thickness (12 SWG) fabricated from GI sheet GI coupler plate and hardware and all nacessary Vertical or horizontal fixing arrangements as required on site complete as directed by Engr-in-Charge
S&F Hot Dip galvanised perforated cable tray and cover of width 100 mm, depth 25 mm and thickness (16 SWG) fabricated from GI sheet GI coupler plate and hardware and all nacessary Vertical or horizontal fixing arrangements as required on site complete as directed by Engr-in-Charge
S & F Rigid non-metallic PVC conduit 20 mm to 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
M& L for wiring complete with 2.5 sqmm single core multistanded copper conductor FRLS PVC insulated and unsheathed cable 1100V grade conforming to IS 694 drawn through steel ERW conduit of 25mm ( external) flame proof, heavy grade ISI marked including necessary conduit accessories surface on wall , ceiling etc. including sunken type pressed steel terminal boxes with phinolic laminated sheet of approved shade 3mm thick including 1.5mm PVC insulated flame retardent copper conductor as in continous earth wire for-
One flame proof light point/Fan Point controlled by one way metal clad switch
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V
Supply and fixing LED light fitting 1x 20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size
Supply & Fixing flame proof single phase exhaust fan 305 mm 12" 230 volts, 1440 RPM, fitted with FLP motor 0.25 HP including louver and making hole in existing wall for fixing the fan making good the disturbed surface complete.
Supply & Fix in replacement Recessed pressure die-cast aluminium luminaire fitting 20W suitable for ceiling cutout dia 175 mm round dia in powder coated white finished with drop down PC diffuser with optimized heat sink for efficent heat dissiption with replaceable electronic driver
Supply & Fix in replacement Recessed pressure die-cast aluminium luminaire fitting 9/10W suitable for ceiling cutout dia 100 to 150 mm round dia in powder coated white finished with drop down PC diffuser with optimized heat sink for efficent heat dissiption with replaceable electronic driver
M & L for comprhensive maintenace of Fire alarm system installed at various Tech Bldgs of 9 BRD comprehensive maintenance the following works including Note:- (i) The maintenance cost of fire alarm system shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as batteriess and other cleaning materials etc. (ii) Servicing shall be carried out authorised dealer of manufacturer i.e. OEM. (iii) Non attending the complaint with in 3 days @ Rs. 1000.00/day shall be recovered for the fourth day by the contractor. (iv) The complaint shall be generated by Telephonically/Verbally by concern JE E/M or Engr-Incharge.
(v) Servicing of quaterly basis of fire alarm system installed in following Bldgs including first hand repairs, consisting of normal repairs and cleaning of all components such as smoke detectors/manual call point/sounder/translator/expendor / input/output module etc of any type installed in Bldgs using proper method and tools , replacement of unserviceable Battries of connected system , tightening of all connections as required including replacements of defective spares and required calibration of control pannel and connected items check and maintain the system for efficent functiong of intire system, including troubleshooting and clearance of all faults from the panel.Testing of each Fire alarm system in presence of User and MES Rep and give quaterly basis servicibility report duly signed by user and Engr-in-Charge comlete all as specified & directed in all respect. Note : Major Items if required for Repair shall be measured & paid separately under respective item. (a) OTS Lab ( Hochiki Wireless) (b) DS Lab ( Hochiki Wireless) (c) Terc Lab No 1 ( Hochiki Wireless) (d) Terc Lab 2 ( Hochiki Wireless) (e) NWIT ( Hochiki Wireless) (f) Fire Station ( Hochiki Wireless) (g) ABR Lab ( Hochiki Wireless) (h) ACMI Lab ( Hochiki Wireless) (j) CAFS Lab ( Hochiki Wireless) (k) Site 2 & 4 ( Hochiki Wireless) (l) Clothing store ( Hochiki Wireless) (m) LSW ( Hochiki Wireless) (n) Armoury ( Hochiki Wireed) (o) D Level ( Honywell Morley wired) (p) Tech Bldg Labs ( wired Hony Bell)
Material and labour for supply and fix armored fire cable copper conductor of size 1.5 sqmm two core FRLS in Red colour fixed on wall / roof with GI saddle complete all as specifed and directed by Engineer-in-Charge at site
Supply of Hybrid Wireless Optical Smoke Sensor with Bi-directional wireless communication, Self optimising wireless amplitude and frequency, in-built magnet test, operating on 865 MHz with communication range up to 1200 m in open air, 95% RH (non condensing), Primary & Secondary Power Supply, RED compliant, LPCB Approved, Approved to EN54-7 & 25
Supply of Hybrid Wireless Manual Call Point with Bi-directional wireless communication, Self optimising wireless amplitude and frequency, Resettable Element, fully addressable and intelligent monitoring functionality operating on 865 MHz with communication range up to 1200 m in open air, 95% RH (non condensing), Up to 10 year battery life Dependant on operational usage, Primary & Secondary Power Supply, LPCB approved, Approved to EN54-11 & 25
Supply of Hybrid Wireless Sounder with Bi-directional wireless communication, Self optimising wireless amplitude and frequency, 4 Tone Settings, fully addressable and intelligent monitoring functionality operating on 865 MHz with communication range up to 1200 m in open air with Max. sounder output 93 dB(A) @ 1 metre, 95% RH (non condensing), Up to 10 year battery life Dependant on operational usage, Primary & Secondary Power Supply, LPCB approved, Approved to EN54-3 and 25
Supply of Hybrid Wireless Translator Module with Bi-directional wireless communication, Self optimising wireless amplitude and frequency, Loop Powered, allows the connection of up to 126* radio field devices to an addressable fire detection loop, Incorporates a Loop Short Circuit Isolator and an OLED display, operating on 865 MHz with communication range up to 1000 m in open air, 95% RH (non condensing), RED compliant, LPCB Approved, Approved to EN54-17, 18 and 25
Supply and Fix 230V AC power supply opereated metal gong bell with 12" dia metal gong including fixing accessories all as directed
Supply and fix push button station 230V AC with flush head actuator Red with legend start with 01 NO contact including base box and top cover all as directed
ASHWAMEDH ENGINEERS
sapana enterprises
Yashwanti electricals
K K ENGINEERING SERVICES
M/s Harshal Traders
M/S SVOJAS ELECTROMECH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .