Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-Finance | ₹16.1 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹16.5 LRejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | ₹16.5 L | L2 | Rejected-Finance Bidder rate is High |
| 3 | L3₹18.2 LRejected-Finance VILL BALIPOTA P O NARAJOLE P S DASPUR DIST PASCHIM MEDINIPUR PIN 721211 WEST BENGAL | NARAJOLE | PASCHIM MEDINIPUR | WEST BENGAL | 721211 | ₹18.2 L | L3 | Rejected-Finance Bidder rate is High |
| 4 | Rejected-Technical | - | - | Rejected-Technical technically reject |
Tender Value
Refer Docs
EMD Value
₹34,261
Closing Date
18 Dec 2025, 3:00 pmClosed
EE II CKHED
central kolkata health electrical division P12 CIT Road 1st floor Kol 14
Repairing and renovation of Electrical Installation Works for Plastic OT at Ground Floor Baker Building under the NRS Medical College and Hospital Kolkata Electrical Installation Work
2025_WBPWD_955709_1
WBPWD/EE-II/CKHED/ eNIT-72/25-26
Open Tender
ELECTRICAL WORKS ORG
90 days
NRS MCH
As per NIT
4 documents required · 4 mandatory
₹34,261
19 Jan 2026
21 Nov 2025
22 Dec 2025
21 Nov 2025
18 Dec 2025
26 Nov 2025
Amount
Distn. Wiring in 22/0.3 (1.5 sqmm) single core standard 'FR' PVC insulated & unsheathed single core standard copper wire (Finolex/Havells/RR/Kable Unilay) in 19 mm core, 3 mm thick polythyn pipe complete with all accesorries embedded in wall to light/fan/call bell points with modular type switch (Brand approved by EIC) fixed on modular GI switch board with top cover place flushed in wall incl. mending good damages to original finish. (Average run 8 mtrs.)
a) On board
b) Average run 10 mtr
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloster/RR Kable/Finolex/KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire incl. cutting channel and making necy. connection as required.
a) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [Vide page no-E-9,item no-1(s)](For power Board)
b) 2x6 sqmm+1x 4 sqmm ECC) [Vide page no-E-9,item no-1(y)](TPNDB to SPNDB and Oxygen Pendent Board)
c) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [Vide page no-E-9,item no-1(a1)] (for OT pendent Light and 3tr AC)
d) 3x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC[Vide page no-E-9)(For Auto clave and 5 tr AC)
e) 4 x 10 sqmm+2x 6 sqmm ECC) [Vide page no-E-9,item no-1(d1)](UPS Change Over to UPS Power DB)
f) 4 x 16 sqmm + 2 x 10 sqmm ECC) [Vide page no-E-9,item no-1(g1)] (For VTPN to TPN)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes
a) 2x2.5 sqmm+1x 1.5 sqmm ECC [F-5,9(i)]
b) 2x4 sqmm+1x 2.5 sqmm ECC [ F-5,9(ii&i)]
c) 2x6 sqmm+1x 4 sqmm ECC) [ F-5,9(iii&ii)]
d) 4 x 10 sqmm + 2 x 6 sqmm ECC [ F-5,9(iv&iii)]
e) 4 x 16 sqmm + 2 x 10 sqmm ECC) [ F-5,9(v&iv)]
Cutting channel of 31 mm x 31 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works
a)13 mm dia 3 mm thick polythene pipe without earth continuity wire.
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
a)19 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [ D-9,13 ] Incoming - 230V,40A, DPMCB Isolator [Legrand] (1-nos) [D-5,6] Outgoing - 10KA, (C-characteristics) 6-32A, SPMCB [Legrand] - (12-nos) [D-6,7]
2+12 way [Legrand/ L&T]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10, 14] Incoming - 415V,63A, FPMCB Isolator [ Legrand ] (1-nos) [ D-5,6 ] (1-nos) Outgoing - 10KA, (C-characteristics) 6-32A, SPMCB [ Legrand ]- (18-nos) [ D-6,7 ]
6 way [Legrand/ L&T]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Vide page No D-11, Item No-15] Incoming - 415V, 25/35KA, 160A, FPMCCB (1 -nos)[Vide page No D-8, Item No-10] Outgoing - 10KA, (C-characteristics) 63A, TPMCB - (6 -nos)[Vide page No D-6, Item No-7
6 way [Legrand/ L&T]
Supply & Fixing 240 V, 4 nos. 6/16 A, 5 pin Modular type plug socket with 4 nos. 16A Modular type switch, 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand/Cabtree)
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand/Cabtree)
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. For three nos Autoclave machine and large size water Imersion heater) (Make:- Legrand/Cabtree)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket without plug top on 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand/Cabtree).
Supply & Fixing 240 V, 25 A, Modular type starter and 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand/Cabtree)
Supplying & Fixing of PVC water proof type Loop box(Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass Stud/ terminal make- AC /DC. & 63A FP MCB (L&T) having hinged PVC top cover & 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement,one NL on porcelain insulator etc. on wall as per direction of EIC.(For AC outDoor)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision with 415V,63A four pole MCB,concealed in wall after cutting the wall & mending good the damages to original finish incl. painting,connection & provision for earthing. attachment(Indoor switching)
Supply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. all accessories. (Make- Crompton /Havells/ Usha / Orient) [BEE 5 star rated]Sweep Size- 1200 mm (48"), Wattage :5 55 Watt, R.PM :5 350 Air Deliverv > 220 C.M.M
Supply & Delivery of 230V, 50Hz, 450 mm sweep heavy duty full metal body wall bracket fan having wattage,; 90 Watt, RPM,; 1350, Air Displacement 100 complete with a ll accessories. (Make - Orient/Crompton/ EPC) [BEE star rated]
Supply and Delivery of 4 feet Industrial box type single LED tube fitting incl.Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply and Delivery of 4 feet Industrial box type twin LED tube fitting incl.Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimumluminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Mal{e- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply & Delivery of 240V recess mounted 2'x2' LED downlight having following wattage in white powder coated pressure die cast aluminium housing ,with glare free uniform illumination, suitable for 2' x 2' grid ceiling with CCT (5700K- 6500K) having minimum luminous efficiency of 120 Lm/ Watt or better & 50,000 LED burning hours or more. [Mal{e- Philips/Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing fan down rod (14 SWG- white MS pipe zinc plated) having 19 mm OD 1.8 + / - 0.05 mm thick complete with cutting, making holes for fixing 'd0 '0".'0 the fan incl. necessary con nection wir e (2Xl.5sqmm cu wire) as per direction of EiC
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 3x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. ]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 3x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply of 4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KE!/ Havells/ Gloster as approved by E.1.C]
a) 4 Core 70 sqmm(panel to VTPN)
b) 4 Core 240 sqmm(Out side Fedder panel to building floor panel)
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers,setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.
a) 4 Core 70 sqmm
b) 4 Core 240 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
a) 4 Core 70 sqmm
b) 4 Core 240 sqmm
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [ISi mark, IP55 rated]
a) 300 mm (12") , 4 Blade, RPM s 950, Wattages 55 Watt, Sound levels 46 dB, Air Displacement (In CMH) >750
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [D-14,32 ]
300 MM (12”) for Al
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By TATA-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as per GS.
Connecting the equipments body to earth busbar incl. S & F 25 mm x 3 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode as to GS.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Solid No 10 SWG GI wire
S/laying 100 mm dia GI (ISI-M) pipe for cable protection with all fittings etc in UG trench as per GS.
Supply,Installation,Testing of floor mounted cubicle type indoor compartmentalized 415V., 50 Hz. dust & moisture proof LT Distribution panel board with following electrical accessories fabricated from 14 SWG CRCA sheet with MS angle frame as required. The base of panel should be made with 75 x 40 x 4.4 mm MS channel. The panel should have adequate strength & space to accommodate the incoming & outgoing switches and bus-bars with all interconnection in between the switches and bus-bars with copper flat / flexible wire of suitable capacity. The panel should be provided with cable alley for facilitating connection of all the incoming & outgoing XLPE Cables with termination arrangement by S&F copper terminal stud / bolt of required sizes. The panel with earthing attachment is to be painted with powder coated paint as per direction of EIC. The panel board should consist with the followings:- A. INCOMING:-- 1) 415V., 630A., TPN main switch of open execution type with 3 nos.630Amp. HRC fuses [L&T, Cat no SK 95521] -1no 2) 415V., 630A,ON load Change Over switch. [L&T, Cat no.CO46300OOOO] - 1 No B.Bus Bar:- 4 nos tinned Copper bus bar of size 2x(80X5) mm, mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu bars - 1set.
C.OUTGOING:--(all are SS enclosure type) 1) S & F 415V, 160A, 36kA, 4 Pole MCCB (make -- Legrand, Equivalent L&T, Schneider) ---4 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 95, with spreader terminal,MIL base plate etc as required. 2) S & F 415V, 100A, 36kA, 4 Pole MCCB (make -- Legrand,Equivalent L&T,Schneider) ---10 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 93, with spreader terminal,MIL base plate etc as required. 3) S & F 415V, 63A, 36kA, 4 Pole MCCB (make -- Legrand, Equivalent L&T, Schneider) ---2 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 95, with spreader terminal,MIL base plate etc as required. CABLE ALLEY cable alleys on both sides for out going connection are to be made incl. S & F suitable nos of Brass Studs type connector on insulated chair having current carrying capacities as per the out going switches rating. Inter connection with the M S & Stud connectors is to be made with suitable size stranded copper wire as per the switch rating as specified in Interconnection
INTERCONNECTION Inter connection to be made same with 40X5 mm (For 100A and 160A MCCB) and 20x5 mm (for 63 A MCCB) copper bar/ 35sqmm (For 100A and 160A MCCB) &16sqmm(for 63 A MCCB) stranded flex copper cable (Finolex/Havells/Polycab/RR kabel) & metering circuit with 1.5 sq mm single core stranded FRLS PVC copper wire with proper copper socketing & taping ( R Y B & N). All nut bolts are of Stainless steel type.
READING ARRANGEMENT a) S & F digital multifunction meter (L&T, MFM5010 LED meter CI 1.0 with RS485, cat no-- WL501011OOOO/Schneider Conzerv-EM6400NG)---1nos (for incoming ) c) 500 volt 400/5A CT Coil ( Kappa Make) - 3 nos (for incoming) e) LED type indicating lamp ( R Y B ) - 3nos (incoming) f)Panel mounted digital Voltmeter in 96x96 mm² (AE/ HPL) [0 - 500 Volt] - 01 no. g)Panel mounted digital Ammeter in 96x96 mm² (AE / HPL) [0 - 400 Amp.] - 01 no. f) 2 A MCB ("C" curve, Legrand) --- 3 nos g) Danger board -- 02 no
Drawing and Make,cat no of all items and Cubical Panel must be approved prior any execution/manufacturing work.Test reports of each MCCBs and others should be submitted along with the drawing for necy. approval from EIC.
Dismantling of existing old LT panel box after disconnecting of all incoming & outgoing cables and connected MCCBs/SFUs and others accessories also to be shifting to store room and also mending good damages to original finish as directed by EIC.
Dismantling of existing old VTPN,HTPN,SPNDB,cable,Switch board, power plug, computer board and wiring system after disconnecting of all incoming & outgoing cables/wires and connected accessories also to be shifting to store room as its original condition as directed by EIC.
Supply & Fiixing of indoor type LED SIGN Board i) 8'(L)x4'(B)x.5''(W) ii) 6(L)x4'(B)x.5''(W) fabricated from 3 mm thick ACP sheet on all five sides finished with approved metallic colour & suitable size hollow Al rectangular bar as frame inside the box. All LED Module, wiring to be fixed inside the ACP box. Silicon adhesives, SS screws to be used in such a way so that ingress of water can be restricted inside the box and maintenence / replacement of the LED modules can be done easily. All screws/nuts & bolts/clamps etc metals used inside the box should be of non-ferrous metal/Stainless steel.
SIZE-i)8'X4'=32 sqft.x2 (Front/back)=64.00 sqft ii)4'X0.5'=2.0 sqft x2(Top/bottom) =4.00 sqft iii)8'X0.5'=4.00 sqft X2 (Top/bottom) =8.00 sqft Total=76.00 sqft Plastic OT DEPARTMENT OF Plastic surgery NRS MC&H,KOLKATA-14
Supply & Fixing of Special type of 3D Boxing type letter(6" x 3.5") with top cover openable made from imported 3mm thick Acrylic sheet to accomodate LED module. Only front side of the letter should emit light. side to be made from opaque acrylic sheet. Letter height, width & depth of the letter will be proportionate & as per direction of E.I.C.. Suitable Ratio should be maintained between the letter size, spacing between each letters & spacing between each words as per the direction of the E.I.C. (Calculation of area (square inch) of a letter will be HeightXBreadth of the letter inclusive all wastage. ( letter 33 nos) i)8”x4”=32”Per letter x5 nos. letter=160 sq.inch*80%=128sq.inch II)8”x0.5”=4.00”Per letter x27 nos. letter=108.00 sq.inch*80%=87.00sq.inch Total-215.00 sq inch
Supply & Fixing of LED within the acrylic letter from backside (Make: SAMSUNG-Korea/ROHS) having the following specifications: COLOUR:WHITE or as per the choice of EIC. LIFE:70,000 burning hours. INTENSITY: Uniform without any bright/dark patches. VISIBILITY: 100Mtrs at least for normal eye vision. AMBIENT AIR: 0-50°C; 100% Relative Humidity. POWER CONSUMPTION: 1.5 Watt per module. (1 module consists of 3 nos LED)
SITC of water proof 400 watt Power Supply unit to be fitted inside the Sign board box. inclusive of water tight gaskette fitted stainless steel hinged door box. Input: 100V-240V AC; 4A; 50Hz. Output: 12V DC; 17-20A constant power supply. Make: Meanwell/Ven/Resang or equivalent.
Supply & Fixing of structural type frame suitable for ACP fascia fixing of size (6" x4"x 2" ) to be made by 3mm thick 2" dia square pipe including necessary machining , welding and jointing materials.
Supply & Fixing extra supporting of structure by 3mm thick 1"x 1" square pipe of 6" & 4" length 4 nos each .
S & F of 26 SWG G.I. sheet for covering of back side of iron frame incl. fabrication charge.
Painting the MS structure with 2 coats of RO primer and one coat of synthetic enamel paint after scrapping the structure emery paper properly.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of through 20mm dia PVC rigid conduit pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm)
Transpotatation charges of the above mentioned board from Co's workshop to work site.
Rate is inclusive all taxes and cess
Defect Libility Period 1 year
Electromech Engineers Co-Operative Society Ltd. (BID ID -7566012)
EFFORTECH (BID ID -7619081)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.45 MB
revised2911.pdf
Tender Documents • 0.50 MB
BOQ_2293631.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid