Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.5 LAccepted-Finance | 1 | Accepted-Finance found eligible | |
| 2 | 2₹5.4 L+₹89,998 (20.0%)Accepted-Finance HOUSING COLONY UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 2 | Accepted-Finance found eligible | |
| 3 | Not Admitted-Fee/PreQual/Technical JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
Closing Date
24 Jan 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, MID Akhnoor Nowshera
Office of Executive Engineer, MID Akhnoor Nowshera
Providing/fitting, installation, testing and commissioning of protection panel cum FASD starters for pumping unit no. 01 ,02 along with other allied works at LIS Seripalai.
2023_IFC_202673_1
MID/AN/176
Open Tender
Electrical and Maintenance Works
Item Wise
30 days
AKHNOOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Executive Engineer, MID Akhnoor Nowshera
Exempted
Office of Executive Engineer, MID Akhnoor Nowshera
7 Feb 2023
17 Jan 2023
25 Jan 2023
17 Jan 2023
24 Jan 2023
19 Jan 2023
18 Jan 2023
Providing/fitting, installation, testing and commissioning of protection panel cum automatic star delta starters for pumping unit no. 01 &02 along with other allied works at LIS Seripalai. Description of panel Designing, fabrication, installation, testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. for pumping unit no. 01 & 02 at L.I.S Seripalai. The panel shall be dust and vermin proof fabricated out of 16 SWG CR Sheet supported on M.S. angle of suitable size and having provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: M.C.C.B.The panel should be fitted with an M.C.C.B. of 400 Ampere capacity, 1 no. volt meter, 1 no ammeter along with a set of CTs, 1 No. V.S.S., 1 No. A.S. switch and a set of RYB indicators at incoming side including the bus bars . Outgoing no. 1 : The panel should be fitted with a 120 HP automatic star delta starter comprises of 3 Nos. air break contactors compatible with 120HP induction motor (2 nos. 185 A for main and delta supply, 1 No. air break contactor 140 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no. 1 Outgoing no. 2: The panel should be fitted with a 135 HP automatic star delta starter comprises of 3 Nos. air break contactors compatible with 135HP induction motor (2 nos. 185 A for main and delta supply, 1 No. air break contactor 185 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no.2. Protections device / fault analyzer : A protections devise / fault analyzer shall be fitted with the panel with capability to protect each motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings : A. Voltage related fault: Single phasing, under voltage, over voltage, unbalance voltage. B. Current related fault: Over current / load, dry running, unbalance current / load, earth leakage, short circuiting. C. Display line current of RYB Phase and also line voltage of RY ,YB and BR phase. Bimetal overload relay: Bimetal over load relay of suitable range should be fitted with in the each starter as an extra protection to protect the motors in case of failure of fault analyzer . The job also includes Providing/ fitting of 50 sq mm single core copper cable or equivalent capacity ( 65 mtrs. approx.) from starter no. 01 &02 to motor no. 1 &2 as per site conditions Complete job includes cost of providing/ fitting ,transportation charges ,hire charges of tool and tackles charges, hire charges of skilled and unskilled labour, and all kinds of taxes thereof. complete job Make of MCCB – Any reputed make as per ISO standards.. Make of contactor – Any reputed make as per ISO standards... Make of cable – Any reputed make as per ISO standards..
M.S J K HYDRAULIC ENGGG AND FABRICATOR WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .