Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC WARD NO 11 HOUSE NO 305 JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹38.9 L+₹1.5 L (4.03%)Rejected-Finance HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹41.6 L+₹4.3 L (11.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹43.8 L+₹6.4 L (17.3%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹49.9 L+₹12.5 L (33.6%)Rejected-Finance HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | MOHAN LAL AND SONS L4 | slathia construction works L5 | PARDEEP SHARMA L1 | PROACH ASSOCIATES BUILDERS & ENGINEERS L3 | M/S N.K. POWER SYSTEMS AND PROJECTS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth strip 32X6 mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:3:6 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009, complete all as specified and directed by Engineer-in-Charge. | 35 | Each | 2,800 ₹98,000 Lowest | 3,500 ₹1,22,500 | 3,800 ₹1,33,000 | 4,300 ₹1,50,500 | 3,800 ₹1,33,000 |
| 2.00 | Supply and fix earth pit chamber board of 3.15mm thick mild steel sheet of size 45cmX30cm fixed with12mm thick MS rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters 6cm height i.e Eart pit No, Location, Earthing test Value and date complete all as specified and directed by Engineer-in-Charge. | 110 | Each Job | 450 ₹49,500 | 1,500 ₹1,65,000 | 180 ₹19,800 Lowest | 240 ₹26,400 | 200 ₹22,000 |
| 3.00 | Material and labour for repairs of earthing chamber of size 450x450x300mm depth outside & 250x250x250 mm depth of PCC (1:4:8) type D-2 & including provn of PCC cover including painting of two coat as directed complete all as specified and directed by Engineer-in-Charge. | 155 | Each | 450 ₹69,750 | 300 ₹46,500 | 200 ₹31,000 Lowest | 500 ₹77,500 | 240 ₹37,200 |
| 4.00 | Material and labour for Painting of earth pit chamber with two coat of acrylic emulsion paint including making the earth pit and colour of paint complete all as specified and directed by Engineer-in-Charge. | 200 | Each | 20 ₹4,000 Lowest | 50 ₹10,000 | 20 ₹4,000 Lowest | 400 ₹80,000 | 40 ₹8,000 |
| 5.00 | S & F GI earth continuity conductor or main earthing lead of size 32X6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. complete all as specified and directed by Engineer-in-Charge. | 100 | RM | 80 ₹8,000 Lowest | 110 ₹11,000 | 130 ₹13,000 | 160 ₹16,000 | 140 ₹14,000 |
| 6.00 | S & F copper earth continuity conductor or main earthing lead of size 25x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. complete all as specified and directed by Engineer-in-Charge. | 20 | RM | 400 ₹8,000 | 75 ₹1,500 Lowest | 480 ₹9,600 | 890 ₹17,800 | 590 ₹11,800 |
| 7.00 | Supplying and laying in replacement of GI tubing light grade 40mm bore for protection of strip fixing to pole/wall or in such similar position complete all as specified and as directed by Engineer-in-charge. | 95 | RM | 200 ₹19,000 Lowest | 350 ₹33,250 | 340 ₹32,300 | 290 ₹27,550 | 400 ₹38,000 |
| 8.00 | Design, Supply, installing testing and commissioning factory fabricated out door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engineer-in-charge.
Including Supply and fixing the following :- | 5 | Each Job | 1,18,000 ₹5,90,000 | 1,35,000 ₹6,75,000 | 88,000 ₹4,40,000 | 81,000 ₹4,05,000 Lowest | 1,08,000 ₹5,40,000 |
| 8.01Incoming :- (a) 400 Amps 4 Pole 36 KA Outgoing :- (a) MCCB 160 Amps 4 Pole 25KA-04 Nos. MCCB 63 Amps 4 pole 16KA. (b) MCB TPN 63 Amps -04 Nos. (c) MCB DP 63 Amps-08 Nos. (d) Voltmeter 0-500V with selector switch (Digital type)-01 No. (e) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No. (f) Indicating lamps (RYB) -01 Set (g) PCC Foundation (Civil works) for grouting of panel (h) BUs bar 1200 Amps | ||||||||
| 9.00 | Design, Supply, installing testing and commissioning factory fabricated In door type totally enclosed LT cubical wall mounted panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on wall with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engineer-in-charge. Including Supply and fixing the following :- | 7 | Each Job | 75,000 ₹5,25,000 | 65,000 ₹4,55,000 | 51,000 ₹3,57,000 | 79,000 ₹5,53,000 | 46,000 ₹3,22,000 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 May 2026, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur PO-Garhi Pin-182121
Repair/Maint to LT Network system at 135 EME, Signal Regt, PBE and other locations under GE (Utilities) Udhampur
2026_MES_761909_1
GE/U-31/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹90,000
10 Jun 2026
24 Apr 2026
18 May 2026
24 Apr 2026
15 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth strip 32X6 mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:3:6 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009, complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
| - | Supply and fix earth pit chamber board of 3.15mm thick mild steel sheet of size 45cmX30cm fixed with12mm thick MS rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters 6cm height i.e Eart pit No, Location, Earthing test Value and date complete all as specified and directed by Engineer-in-Charge. | - | Each Job | - | - |
| - | Material and labour for repairs of earthing chamber of size 450x450x300mm depth outside & 250x250x250 mm depth of PCC (1:4:8) type D-2 & including provn of PCC cover including painting of two coat as directed complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
| - | Material and labour for Painting of earth pit chamber with two coat of acrylic emulsion paint including making the earth pit and colour of paint complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
| - | S & F GI earth continuity conductor or main earthing lead of size 32X6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. complete all as specified and directed by Engineer-in-Charge. | - | RM | - | - |
| - | S & F copper earth continuity conductor or main earthing lead of size 25x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. complete all as specified and directed by Engineer-in-Charge. | - | RM | - | - |
| - | Supplying and laying in replacement of GI tubing light grade 40mm bore for protection of strip fixing to pole/wall or in such similar position complete all as specified and as directed by Engineer-in-charge. | - | RM | - | - |
| - | Design, Supply, installing testing and commissioning factory fabricated out door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engineer-in-charge.
Including Supply and fixing the following :- | - | Each Job | - | - |
| - | Incoming :- (a) MCCB 125 Amps 4 Pole -01 No (Incoming)
Outgoing :- (a) MCCB 63 Amps -02 Nos.
(b) MCB TPN 63 Amps -04 Nos.
(c) MCB DP 63 Amps-08 Nos.
(d) Voltmeter 0-500V with selector switch (Digital type)-01 No.
(e) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No.
(f) Indicating lamps (RYB) -01 Set
(g) PCC Foundation (Civil works) for grouting of panel
(h) BUs bar 1200 Amps | - | - | - | - |
| - | Design, Supply, installing testing and commissioning factory fabricated In door type totally enclosed LT cubical wall mounted panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on wall with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement, including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engineer-in-charge. Including Supply and fixing the following :- | - | Each Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDER31.pdf
Tender Documents • 1.29 MB
BOQ_853448.xls
BOQ • 8.31 MB
Amendmenttodate.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .