Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹27.2 L+₹84,581.50 (3.21%)Rejected-AOC SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹28.2 L+₹1.9 L (7.17%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹28.5 L+₹2.2 L (8.22%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹28.8 L+₹2.5 L (9.36%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
31 Mar 2021, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Provision of certain sanction works (03) in the area of AGE B/R I under GE (N) Ahmednagar
2021_MES_428098_1
8507 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹64,000
Yes
9 Apr 2021
5 Mar 2021
2 Apr 2021
5 Mar 2021
31 Mar 2021
19 Mar 2021
Amount
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor etc complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor etc complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic coloured tiles of size 350 x 250 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 15 mm thick on stone masonry surfaces in cement and sand mortar (1:6) on wall finished even and smooth without using extra cement with sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 10 mm thick on concrete surfaces in cement and sand mortar (1:4) on ceiling finished even and smooth without using extra cement surface finish etc complete all as specified and directed by Engineer-in-Charge
M&L for 3 coats of white wash on newly / old plastered surfaces including preparation of wall etc complete all as specified and directed by Engineer-in-Charge
M&L for 3 coats of white wash on newly / old plastered surfaces including preparation of ceiling etc complete all as specified and directed by Engineer-in-Charge
Material and labour for special treatment to sunken slab floor incl WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment, then injection grouting the weak areas on the concrete surface with cementitious grout and applying 10mm thick cement plaster in CM 1:4. Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished rainforce with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torach and sealing all joints etc and preparing the surface complete. and providing PCC 1:5:10 type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC 1:4:8 type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, non-skid glazed tiles as per existing pattern/size/tint, area of WC exc 1.00 Sqm but nexc 5.00 sqm etc after dismantling the existing sunken floor etc complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame) etc complete all as specified and directed by Engineer-in-Charge
Taking down steel windows / ventilators, of any description and size each etc complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each etc complete all as specified and directed by Engineer-in-Charge
S&F in repair Steel ventilator with top hung shutter including hinges, steel peg stay, etc complete all as specified and directed by Engineer-in-Charge
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge
S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded plain coloured PVC `C' channel having a PVC sheet strip of 20 mm width stuck and plain colour PVC sheets for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter with lock rail and panel of 9 mm BWP commercial plywood. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long aluminium anodised handle, cast type etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long mild steel barrel tower bolt, stove enamelled black, with bright bolt etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long mild steel pressed handles, oval type, stove enamelled black etc complete all as specified and directed by Engineer-in-Charge
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples etc complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones etc complete all as specified and directed by Engineer-in-Charge
M&L for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position etc complete all as specified and directed by Engineer-in-Charge
All as per item No 27 (here-in-before) but 20mm dia pipe.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling etc complete all as specified and directed by Engineer-in-Charge
All as per item No 29 (here-in-before) but 20mm dia pipe.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls all as directed.
S&F 110 mm dia PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequaletc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC (SWR) bend any radius etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC (SWR) bend with access door any radius etc complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) floor trap, 75 mm dia with grating including jointing with solvent cement etc complete all as specified and directed by Engineer-in-Charge
Supply and fix PVC valveless, syphonic action type, flushing cistern,low level, all accesories all as directed. Make :- Sleek essence series of Hindware or Cat part No E8303 of Parryware or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs wash hand basin vitreous China white, flat back type of size 550 X 400 mm pedastal type including pedastal, CP waste chain and plug and porcelain stopper, waste pipe, a pair of brackets,or errecting stand and PVC connection all as specified and directed. Make :- Cat Part No 10098 of Hindware or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs looking mirror of size 600 mm X450 mm all as directed. Make:- Cat part No C 8606 Of Parryware or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren complete all as specified and directed.Make :- Cat Part No C0117 Of Parryware or Cat Part No 20042 of Hindware or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fixing in repairs vitreous china wash down water closet (Pedestal pattern) white including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom and cover and MSCP almn hinges device complete connecting to 'P' or 'S' trap etc complete all as specified and directed by Engineer-in-Charge Make:-Petite series Cat part No C0287(S)/88(P) including seat cover Cat part No E8309 of Parryware or equivalent makes mentioned in list of makes in Appendix `C'
S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including conncetion to flushing pipe and waste pipe providing and fixing plugs bedding urinal against wall etc complete all as specified and directed by Engineer-in-Charge
Supply and fix bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as directed.Make:- Cat part No MOR 1020 A (Orintal series) of MARC or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as directed.Make:- Cat part No MOR 1010(Orintal series) of MARC or equivalent in or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in repair stop valve, 15 mm dia, cast copper alloy,screwed down high pressure screwed down high pressure with cruitch or butterfly handle screwed both ends for iron pipe or for unions all as directed. Make:- Cat part No MOR 1320 (Orintal series) of MARC or equivalent makes mentioned in list of makes in Appendix `C'
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair health faucet (hand shower) with 8 mm dia 1 m long flexible tube wall mounted / hooked all as per Cat Part No 573 of Jaquar or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs, shower rose with shower arm from Make:- Cat part No MARC MSR1050 (Shower) and MOR 1260(Shower arm) from MARC or equivalent makes mentioned in list of makes in Appendix `C'
S&F in repairs, aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges etc complete all as specified and directed by Engineer-in-Charge
S&F in repair toilet paper holder, vitreous China white box type fixed to wall with chromium plated (CP) brass secrws etc complete all as specified and directed by Engineer-in-Charge
Dismantling of water tanks of capacity n.exc 1000 ltrs and removing from site etc complete all as specified and directed by Engineer-in-Charge
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 1000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting complete all as specified and directed.
S & F of ball brass valve, 20mm bore dia of pipe, high pressure with polythene float and flynet complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed by Engineer-in-Charge
Supplied and fixed 20mm Bore dia of pipe gun metal and glob or gate valve with iron wheel head, screwed both ends for iron pipe etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs 32 mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
Material and Labour for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out etc complete all as specified and directed by Engineer-in-Charge
Material and labour for 75 mm thick plain cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate as in sub base etc complete all as specified and directed by Engineer-in-Charge
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge
M&L machined pressed precast concrete interlocking paver block glossy with grey cement and pagment, any shpae and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over a stone dust cushion of 30mm thick etc complete all as specified and directed by Engineer-in-Charge
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge
M&L for Filleting in any position and to any shape in cement lime mortar 1:4 including all mitres, stops, (exc 25 sqcm but n'exc 50 sqcm etc complete all as specified and directed by Engineer-in-Charge
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge
M&L for Cement concrete (1:4:8) Type D2 using 40 mm graded stone aggregate in foundations, filling and mass-concrete in lean concrete of drain etc complete all as specified and directed by Engineer-in-Charge
M&L for Pre-cast cement concrete block masonry Type C1 (1:3:6) 20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement and sand mortar (1:6), etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15mm thick plaster on fair faces of brick work or concrete surfaces to be finished even and smooth (without using extra lime or cement in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:2:4 type B1 using graded stone aggregate as in coping including necessary formwork, weatherig, slightly rounded or chamfered angle and throating etc complete all as specified and directed by Engineer-in-Charge
Returning , filling in including in spreading , leveling,watering and well raamming in layers.n exc 25 cm in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
Removing surplus & soil to a distance exc. 250 m but n exc. 500 m & depositing where directed by engineer - in charge at a level n exc 1.5 mtr above the starting point etc complete all as specified and directed by Engineer-in-Charge
M&L for form work to sides of concrete foundations, footings, bases of columns rafts and raft beams sides and sofits (if any) of foundation and plint beams and similar work in fair finished surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M25 design Mix using 20mm graded stone aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge
S&F Steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 etc complete all as specified and directed by Engineer-in-Charge
M&L for prepration of new steel surfaces over 10cm in width or girth & applying 2 coats of synthetic enamel paint over a coat of red oxide primer.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-ChargeNOTE: Wire cloth, glass, guard bars and painting shall be measured and paid separately.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, etc complete all as specified and directed by Engineer-in-Charge NOTE: Wire cloth, glass, guard bars and painting shall be measured and paid separately.
M&L for glazing with 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane etc complete all as specified and directed by Engineer-in-Charge
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC Boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. (Make of Cable : Finolex/RR Cable/Havells & Make for Casing & capping : AKG/PRESTOPLAST/PRECISION): - Note : 1. Porper colour coding must be utilize for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by one switch
One fan point controlled by one switch
One 3 pin 5 Amps socket outlet on same board controlled by one switch
One 3 pin 5 Amps socket outlet on independent board controlled by one No piano type switch 5 Amps single pole one way
All as per Item No 80 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket outlet on independent board
S&F switch piano flush type single pole, one way 5/6 Amps etc complete all as specified and directed by Engineer-in-Charge.
S&F Switch socket combination 2 in 1, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination 5 in 1, 5/16 Amps flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement double door Sheet metal enclosures factory made DBs 8 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB , SP, AC, 240 volts of 06 to 40 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
S&F LED Tube light fitiing 20 Watt with LED light source with uniform light output, surge protecttion of 2 KV with wide voltage protection 160-360 V with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories all as specified & directed Make ; Philips Astra Line 20 W 4 Ft or its equivalent makes mentioned in list of makes in Appendix `C'
S&F LED Tube light fitiing 9 Watt with LED light source with uniform light output, surge protecttion of 2 KV with wide voltage protection 160-360 V with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories all as specified & directed Make ; Philips Astra Line 9 W 2 Ft or its equivalent makes mentioned in list of makes in Appendix `C'
S&F LED Tube light fitiing 9 Watt with LED light source with uniform light output, surge protecttion of 2 KV with wide voltage protection 160-360 V with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories all as specified & directed Make ; Philips Astra Line 9 W 2 Ft or its equivalent makes mentioned in list of makes in Appendix `C'
S & F Lumeno LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder and wall light etc complete all as specified and directed by Engineer-in-Charge
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through in and incl PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly all as specified & directed. (Make of Cable : Finolex/RR Cable/Havells & Make for PVC Casing & Caping : AKG/PRESTOPLAST/PRECISION): - Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) Note: Two run of 6 sq.mm cable i.e for one run for phase, one run for neutal with one run of 6 sq.mm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25mtr depth and top edge of the earth plate not less than 1.5mtr below normal ground level connected to galvanised earth lead wire 4.0Sqmm dia by means of nuts,bolts & washer etc. Earth wire connected upto main earth point/DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 ( using 20 mm graded stone agregate) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of ms bar @ 15 mm CIC with both way lifting arrangement complete including all necessary excavation & earth work all as specified and directed
M&L point wiring complete with 1.5sqmm single core unsheathed PVC insulated FRLS cable 1100 V grade multistranded copper conductor of different code of ISI marked drawn through and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including provision of PVC box of suitable size for mounting switches / sockets and fan regulators etc complete all as specified and directed for the following:-
(a) One light point controlled by one switch one way
(b) One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way
(c) One switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board.
M&L switch piano flush type single pole,one way, 5 Amps, 240 V etc complete all as specified and directed by Engineer-in-Charge
S&F lamp holder,PVC/Polycarbonate type with back plate suitable for batten fittings etc complete all as specified and directed by Engineer-in-Charge
M&L sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in PVC Casing caping 20mm etc complete all as specified and directed by Engineer-in-Charge (a) 2 run of 4sqmm PVC FRLS copper cable and 1run of 2.5 sqmmPVC FRLS copper cable for earth wire Note for sub main wiring :- 2 runs of wire and 1 run of earth wire will be measured as one unit i.e RM 2. Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted rate.wiring 2 run of wire and1 run of earth wire .
S&F sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 4 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 10 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB , SP, AC, 240 volts of 06 to 40 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories all as specified & directed Make ; Havells E-LITE LED PRIDE PLUS NEO Cat No LHEXACP71N1W020) or its equivalent makes mentioned in list of makes in Appendix `C'
S & F Lumeno LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder and wall light etc complete all as specified and directed by Engineer-in-Charge
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver all as specified and directed Make: Havells/philips/wipro etc complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth and getting out in hard /dense soil etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of under ground cable, pole foundation and stays etc and getting out in soft/disintergrated rock etc complete all as specified and directed by Engineer-in-Charge
Returning, filling in including levelling, watering and well ramming in layers, n.exc 25 cm each in soil etc complete all as specified and directed by Engineer-in-Charge
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Cutting to existing CI/GI pipe line upto 80 /50/25 mm dia for taking connection up to 25 mm dia GI pipe including insertion of CI /GITee complete all as specified and directed including Exc & earth Work
Supply and lay in trenches/or on wall medium grade steel water tubing galvanised with all fittings and joints etc complete for following size :-
(a) 20 mm bore
S&F Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed by Engineer-in-Charge
Supply and fix gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for for 20 mm bore etc complete all as specified and directed by Engineer-in-Charge
Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm (2 ”) dia etc complete all as specified and directed by Engineer-in-Charge
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm bore etc complete all as specified and directed by Engineer-in-Charge
Supply and fix gun metal gate Valve,conforming to IS 13095, 50 mm (2.5”) dia etc complete all as specified and directed by Engineer-in-Charge
Supply and fix gate Valve, stop, screwed,25 mm dia pipe etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of LED Flood Light 70 Watt, Lumans output 7000 with high luminious efficiency , protected to IP-65 with front toughened glass .and connecting with 4 sqmm twin core aluminium cable approx 2.00mtr Length. Make: Philips cat part No BVP120LED 70 CW NB FG S1PSU GR or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fixing GI pipe Bracket for street light of Light Grade 40mm bore including making bends as required etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing of MS clamps of size 25x3 mm with nut, bolt and washers duly painted in two coats of aluminium paint over a coat of red oxide etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing 1100 volts 10 Sqmm stranded conductor grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire one twin core cable flat or circular, etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing sintex box of size 200x175x100mm for street ligt control box including 35x5mm size MS FI clamp with Nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge
Supply and laying or fixing or passing in trenches/ on pole / through pipes, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 10 sq mm 2 core including connection with cable glands & lugs etc and testing on etc complete all as specified and directed by Engineer-in-Charge
Supply and laying or fixing or passing in trenches/ on pole / through pipes, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 35 sq mm 3.5 core including connection with cable glands & lugs etc and testing on completion etc complete all as specified and directed by Engineer-in-Charge
S&F double door sheet metal enclosures factory made DBs 8 way, 240 volts protection class IP-42 suitable for fixing fo MCB, SPN confiming as per IEC 61439-3 suitable for Flush mounting and surface mounting with 100 A copper Bus bar with Neutral bar Earth bar and cable ties for cable management, fully shrouded Neutral bars, Prefitted masking sheet compete all as specified and as directed
S&F MCB single Pole of 240 6-32 Amps , 10 KA capacity C Series etc complete all as specified and directed by Engineer-in-Charge
S&F MCB SPN 240 volt 63 Amps 10 KA capacity C series etc complete all as specified and directed by Engineer-in-Charge
Supplying and laying HDPE pipe of 70 mm dia bore for UG cable passing under floor/road crossing / wall etc complete all as specified and directed by Engineer-in-Charge
An amount of Rs 22,399.00 shall be deducted from BOQ on account of schedule of credit
sunway associates
M/s.Abhay Kulkarni and Associates
Ms. M.D. Auty
M/s. A P INFRA
Priyadeep Construction
TAKSHASHILA ELECTRICALS
M/s. N D Karande
R. T. Saluji
AMAR CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .