| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹29.6 L+₹2.1 L (7.66%)Rejected-Finance H O 325 JAIPUR HOUSE AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹30.6 L+₹3.2 L (11.5%)Rejected-Finance 0 NAGLA UDHA AZIJ PUR SOHALLA ROAD DHANOLI AGRA AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹30.7 L+₹3.2 L (11.7%)Rejected-Finance NAGLA NANDA DHANAULI JAGNER ROAD AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹31.1 L+₹3.6 L (13.1%)Rejected-Finance | L5 | Rejected-Finance Being higher bidder |
| Sl No | Description | Qty | Unit | durgey traders L3 | Rakesh Kumar L2 | FUTURE Inc. L1 | M/S Arti Constructions L4 | M/s S.M. Construction L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Taking up/down GI tubing in any length including fitting from trenches, walls, ceilings for relaying/replacement for the following sizes all as specified and directed :- | ||||||||
| 1.01 | 15mm bore tubing | 734 | RM | 10 ₹7,340 | 5 ₹3,670 Lowest | 10 ₹7,340 | 10 ₹7,340 | 5 ₹3,670 Lowest |
| 1.02 | 20mm bore tubing | 1,604 | RM | 10 ₹16,040 | 5 ₹8,020 Lowest | 10 ₹16,040 | 12 ₹19,248 | 5 ₹8,020 Lowest |
| 1.03 | 25mm bore tubing | 664 | RM | 10 ₹6,640 | 5 ₹3,320 Lowest | 10 ₹6,640 | 15 ₹9,960 | 6 ₹3,984 |
| 1.04 | 40mm bore tubing | 596 | RM | 10 ₹5,960 | 15 ₹8,940 | 10 ₹5,960 | 22 ₹13,112 | 7 ₹4,172 Lowest |
| 1.05 | 50mm bore tubing | 696 | RM | 10 ₹6,960 | 15 ₹10,440 | 10 ₹6,960 | 25 ₹17,400 | 8 ₹5,568 Lowest |
| 1.06 | 80mm bore tubing | 584 | RM | 10 ₹5,840 | 30 ₹17,520 | 15 ₹8,760 | 30 ₹17,520 | 9 ₹5,256 Lowest |
| 1.07 | 100mm bore tubing | 592 | RM | 10 ₹5,920 Lowest | 30 ₹17,760 | 15 ₹8,880 | 35 ₹20,720 | 10 ₹5,920 Lowest |
| 2.00Laying only GI tubing in any length with connections, laid in trenches as retrieved from item No.1 here-in-before after cleaning, washing or removing old screw thread as required with and including providing new fittings, as required complete all as specified and directed for the following sizes:- | ||||||||
| 2.01 | 15mm bore tubing | 48 | RM | 10 ₹480 | 5 ₹240 Lowest | 10 ₹480 | 20 ₹960 | 20 ₹960 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
23 Jul 2025, 6:00 pmClosed
GE TECH AREA AGRA
Military Engineers Services Garrison Engineer (AF) Tech Area Agra - 282008
PETTY/ESSENTIAL REPAIRS TO WATER SUPPLY SYSTEM AT SUKH NIWAS, DSML, ML AREA, SU COMPLEX OF GE (AF) TECH AREA AGRA
2025_MES_708173_1
8200-1689/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
AF TECH ATREA AGRA
Class D category a(ii)
8 documents required · 8 mandatory
₹500
Yes
GE TECH AREA AGRA
₹70,000
Yes
27 Aug 2025
24 Jun 2025
28 Jul 2025
24 Jun 2025
23 Jul 2025
9 Jul 2025
Amount
Taking up/down GI tubing in any length including fitting from trenches, walls, ceilings for relaying/replacement for the following sizes all as specified and directed :-
15mm bore tubing
20mm bore tubing
25mm bore tubing
40mm bore tubing
50mm bore tubing
80mm bore tubing
100mm bore tubing
Laying only GI tubing in any length with connections, laid in trenches as retrieved from item No.1 here-in-before after cleaning, washing or removing old screw thread as required with and including providing new fittings, as required complete all as specified and directed for the following sizes:-
15mm bore tubing
20mm bore tubing
25mm bore tubing
40mm bore tubing
50mm bore tubing
80mm bore tubing
100mm bore tubing
Laying or fixing only, GI tubing with connections in any length as retrieved from item No.1 here-in-before, fixed to wall, ceiling or laid in/on floor after cleaning, washing or removing old screw thread as required with and including providing new fittings, wherever required, complete all as specified and directed for the following sizes :-
15mm bore tubing
20mm bore tubing
25mm bore tubing
Supply, laying, testing of GI tubing medium grade, laid in trenches in any length including required GI fitting complete all as specified and directed for the following bore :-
15mm bore tubing
20mm bore tubing
25mm bore tubing
40mm bore tubing
50mm bore tubing
80mm bore tubing
100mm bore tubing
Supply, fixing, testing of GI tubing medium grade, fixed on walls / ceiling or laid in/on floor in any length including GI fitting and fixing accesoories complete all as specified and directed for the following bore :-
15mm bore tubing
20mm bore tubing
25mm bore tubing
M&L for drilling & tapping cast iron mains in position for branch connection of 20mm bore GI pipe with MS clamps including necessary earth work if required etc complete all as specified and directed.
S&F in renewal gun metal globe or gate valve with iron wheel head, screwed both ends ISI marked complete all as specified & directed for the following sizes:-
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
S&F in renewal 15mm bore bib tap, standard of PTMT any colour screwed for iron pipe and fixed complete all as specified and directed.
M&L in renewal for lead joints including spun yarn & taking out old lead by burning etc for the following bore of CI pipe/fittings complete all as specified and directed. Note: (i) The quoted rate shall be deemed to include necessary earth work. (ii) Old taken out lead to be used in making of lead joint.
300mm bore
200mm bore
150mm bore
100mm bore
80mm bore
Dismantling, opening head of sluice valve, taking out wedge nuts / spindle with nuts / wedge for replacement and refixing after replacement of Gun metal wedge nuts and stainless steel spindles and refacing /regrinding sheet etc for the following size of sluice valve including nuts, bolts, washer, rubber packing and gland complete all as specified and directed.
300mm bore
150mm bore
100mm bore
80mm bore
S&F in renewal of cast iron body sluice valve ISI marked PN 1.6 and conforming to IS 14846 with stainless steel spindle of following sizes :-
200mm bore
150mm bore
100mm bore
80mm bore
M&L in renewal for ‘D’ joints complete with collars, rubber ring, nuts & bolts etc for following bore complete all as specified and directed:-
300mm bore
200mm bore
150mm bore
100mm bore
80mm bore
50mm bore
S&F in renewal of non return valve ISI marked including complete fixing accessories of following sizes:-
150mm bore
100mm bore
80mm bore
Supply, lowering and testing in renewal 32mm dia UPVC column pipe in bore well ISI marked pressure rating PN-15 kg/cm2 and with jointing material and fitting including taking down old U/S HDPE/UPVC pipe all as specified and directed.
Supply & laying in renewal PVC insulated and PVC sheathed copper conductor cable 2.5 Sqmm, 3 core flat for 1100 volts AC including connecting with submersible motor to starter panel complete all as specified and directed.
Supply and fixing in renewal wall mounted cubical type panel board with locking arrangement, comprising of starter, condenser, volt meter, indicator lamp, Amp meter, MCB/cut out of suitable capacity for 1.5/2 HP single phase submersible pumping set including fixing arrangement complete all as specified and directed.
Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc.1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
Removal of excavated material to a distance not exc 50 Meter and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
Taking out unserviceable submersible pump set including motor from bore well of capacity 1.5HP after disconnecting all electrical connections & supply, fixing, lowering, commissioning & testing of submersible pump set of discharge capacity 70 LPM at 57 metre head single phase, 230 volt AC electric driven 2900 RPM of 1.5 HP including necessary wiring from motor to panel etc complete all specified and directed.
Taking out unserviceable submersible pump set including motor from bore well of capacity 12.5 HP after disconnecting all electrical connections & Supply, installation, commissioning and testing of V-8 Submersible pump, electric driven 415 V, three phase suitable for 200 mm dia bore well (Casing pipe size 150 mm) of 12.5 HP capacity, 4 stage, outlet size 100 mm, 16-55 mtr head, 1700-500 LPM complete all as specified and directed.
S&F in replacement of fully automatic star-delta starter of relay range 8.9-13.5 Amps of capacity suitable upto 12.5HP motor, AC-3 phase heavy duty, 415 volts, 50 Hz including fixing arrangement on wall complete all as specified and directed.
M&L for construction of brick masonry valve pit with sub-class 'B' bricks (old size), built in cement mortar (1:6), of size (90 x 90 x 90) cm (internal dimension) with one brick thick walling and 150 cm x150 cm x 10 cm base foundation with PCC (1:3:6), type C2, cement plastering 10 mm thick with cement mortar (1:4) on internal & exposed surfaces, of brick work with and including MS cover of size 01mtr x 01mtr made out from 3 mm thick MS sheet iwith (40 x 40 x 5) mm angle iron framing & painting the steel surfaces with two coats of synthetic enamel paint (first quality) over a coat of red oxide primer, including necessary excavation and earth work and demolition of the existing old valve and removal of old demolished materials and surplus excavated soil to a distance n.exc 50m etc complete all as specified and as directed.
Carryout day to day rectification of water supply complaint such as repair, reconnection and replacement of water supply system in air force station Agra area all as directed by Engr in Charge. Note:- (a) 01 x Pipe fitter and 01 x helper will be detailed by the contractor for attending above complaints on daily basis. Cost of which shall be deemed to be included in quoted rates. (b) Replacement of major items shall be measured and paid under relevant items of this schedule. (c) Pipe fitter and helper so detailed by the contractor will report to MES complaint cell at 0845 hrs morning to receive complaint slip from department and complaints shall be rectified within 08 Hours. If contractor fails to detail above tradesmen a panel recovery @ Rs.1000.00 per day shall be made to contractor and shall be recovered from his RAR/Final bill. (d) Repairing upto 06 Complaints at different water supply system with minor fittings/fixtures materials costing upto Rs 500/- will be considered as one job.
S&F in replacement of ball brass valves of 20mm dia size, high pressure, with polythelene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in replacement of ball brass valves of 25mm dia size, high pressure, with polythelene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Demolition of concrete of any description and in any position, cutting roads, cement concrete in floor/paving all as specified and directed.
M&L for PCC 1:2:4 (nominal mix) type B-2 using 40mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed.
Rakesh Kumar (BID ID -3360344)
durgey traders (BID ID -3360210)
M/S Arti Constructions (BID ID -3360960)
M/s S.M. Construction (BID ID -3360430)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .