Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAdmitted-Finance E BLOCK 2ND FLOOR INTERNATIONAL TRADE TOWER NEHRU PLACE VILLAGE TOWN NEHRU PLACE CITY DELHI SOUTH DELHI DELHI 110019 INDIA | SOUTH EAST DELHI | DELHI | 110019 | ₹2.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.1 Cr+₹1.4 Cr (51.5%)Admitted-Finance FLAT NO 53 FLATTED FACTORY COMPLEX BLOCK C 3RD FLOOR JHANDEWALAN CENTRAL DELHI DELHI 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹4.1 Cr+₹1.4 Cr (51.5%) | L2 | Admitted-Finance |
| 3 | L3₹5.6 Cr+₹2.9 Cr (107.7%)Admitted-Finance B 405 NOIDA ONE SECTOR 62 NOIDA 201301 | NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹5.6 Cr+₹2.9 Cr (107.7%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT RECOMMENDED |
| Sl No | Description | Qty | Unit | Heat Trace India Pvt Ltd L2 | SST GS INDIA PVT LTD L1 | eltherm India Private Limited L3 |
|---|---|---|---|---|---|---|
| 1.00Electrical Heat Tracing along with Insulation Works of Tank | ||||||
| 1.01Design, detail engineering, submission of drawings & calculations, procurement, testing at vendor's works, supply including procurement services of all equipment / materials for complete Electrical Heat tracing system as mentioned in tank PDS, Electrical SOW attached elsewhere in the tender; including supply of required quantities & rating of weatherproof PDBs & LDPs, all power and control cables from PDBs/LDPs to tracers/RTDs, multi circuit temperature controller, junction boxes, T-connectors, heating tape, tracer, interface equipment with Owner’s DCS system, necessary connectors and all associated materials, earthing materials, mandatory spares, commissioning spares, special tools & tackles and consumables, construction, fabrication, transportation of equipment/ materials from contractor's warehouse/store to place of installation, unpacking, surface preparation, installation, testing, mechanical completion, pre- commissioning and commissioning required for completing & establishing a fully functional and operative Electrical Heat Tracing System and associated facilities including any balance field engineering, supply of all erection materials & structural supports/MS frames required (for installation of PDBs, LDPs, Power connectors, T-connectors, junction boxes, heating tape/tracer, necessary fixing arrangement of cables on tank, etc.), laying, connection & termination of all power & control cables from PDB/LDP to tracers/RTDs, testing of multi circuit temperature controller, installation of earthing material and connection to purchaser's earthing grid, installation of metallic tags, aluminum fixing tape, cable glands & lugs, all other associated materials, etc. as required for process, testing and commissioning of complete system providing construction and all other activities complete as per scope of work/supplies detailed in various sections of the tender document, drawings, specifications, including civil works such as concrete foundations, excavation, disposal of surplus earth, sand, bricks, aligning, levelling, grouting / welding, bolting, riveting, etc. including all labour and materials as per tender document, approved drawings, specifications of this tender and direction of Engineer in charge. | ||||||
| 1.02 | For Tank 261-TK-2002 | 1 | Lumpsum | 25,97,683 ₹25,97,683 | 4,63,233 ₹4,63,233 Lowest | 11,41,000 ₹11,41,000 |
| 1.03 | For Tank 261-TK-2003 | 1 | Lumpsum | 49,11,843 ₹49,11,843 | 15,99,333 ₹15,99,333 Lowest | 25,24,000 ₹25,24,000 |
| 1.04 | For Tank 261-TK-2011 A | 1 | Lumpsum | 1,13,91,129 ₹1,13,91,129 | 32,24,211 ₹32,24,211 Lowest | 46,67,000 ₹46,67,000 |
| 1.05 | For Tank 261-TK-2011 B | 1 | Lumpsum | 1,13,91,129 ₹1,13,91,129 | 33,07,564 ₹33,07,564 Lowest | 46,67,000 ₹46,67,000 |
| 1.06APPLICATION OF INSULATION FOR ELECTRICAL HEAT TRACED TANKS: Supply of all materials, application of insulation as applicable on outside surface of tank shell, roof, nozzles, manholes, appurtenances, attachments etc., including supply of all materials and installation of all insulation supports as per Job Specification: C068-261-06-43-IL- S001, applicable standards and completing the work in all respect as per drawings, specifications, standards and instructions of Engineer-in-Charge. Surface preparation and primer application on insulated surfaces is covered under painting Schedule of rate. All materials shall be Supplied by Contractor . | ||||||
| 1.07 | For tag no 261-TK-2002 & 261-TK-2003
Inner Layer (Rock wool) : 25mm | 2,600 | m² | 995 ₹25,87,000 Lowest | 2,394 ₹62,24,400 | 3,370 ₹87,62,000 |
| 1.08 | For tag no 261-TK-2002 , 261-TK-2003 & 261-TK-2011A/B Outer Layer (In Situ PUF) : 50mm | 4,110 | m² | 1,030 ₹42,33,300 | 1,002 ₹41,18,220 Lowest | 5,500 ₹2,26,05,000 |
| 1.09 | For tag no 261-TK-2011A/B Inner Layer (Rock wool) : 65mm | 3,020 | m² | 1,125 ₹33,97,500 Lowest | 2,585 ₹78,06,700 | 3,700 ₹1,11,74,000 |
Tender Value
Refer Docs
Closing Date
2 Mar 2026, 4:00 pmClosed
General Manager (Commercial)
Bridge and Roof Co. (India) Ltd Kankaria Centre (4TH/5th Floor) 2/1 Russel Street Kolkata 700 071
WORKS CONTRACT FOR ELECTRICAL HEAT TRACING ALONG WITH INSULATION OF TANK ON SUB-CONTRACT BASIS IN CONNECTION WITH TANKAGE WORK FOR LUBE MODERNIZATION and BOTTOM UPGRADATION (LMBU) PROJECT OF HPCL, MUMBAI REFINERY, INDIA
2026_BandR_897694_1
BANDR/HO/71171/EHT and INSUL /SC / NIT 02
Limited
Miscellaneous Works
Works
240 days
HPCL, MUMBAI REFINERY, INDIA
ALL Technical Document Detail is provided in eNIT page 121 as a GOOGLE LINK
9 documents required · 9 mandatory
₹0
Exempted
27 Mar 2026
9 Feb 2026
4 Mar 2026
9 Feb 2026
2 Mar 2026
11 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical Heat Tracing along with Insulation Works of Tank | |||||
| 1.01 | Design, detail engineering, submission of drawings & calculations, procurement, testing at vendor's works, supply including procurement services of all equipment / materials for complete Electrical Heat tracing system as mentioned in tank PDS, Electrical SOW attached elsewhere in the tender; including supply of required quantities & rating of weatherproof PDBs & LDPs, all power and control cables from PDBs/LDPs to tracers/RTDs, multi circuit temperature controller, junction boxes, T-connectors, heating tape, tracer, interface equipment with Owner’s DCS system, necessary connectors and all associated materials, earthing materials, mandatory spares, commissioning spares, special tools & tackles and consumables, construction, fabrication, transportation of equipment/ materials from contractor's warehouse/store to place of installation, unpacking, surface preparation, installation, testing, mechanical completion, pre- commissioning and commissioning required for completing & establishing a fully functional and operative Electrical Heat Tracing System and associated facilities including any balance field engineering, supply of all erection materials & structural supports/MS frames required (for installation of PDBs, LDPs, Power connectors, T-connectors, junction boxes, heating tape/tracer, necessary fixing arrangement of cables on tank, etc.), laying, connection & termination of all power & control cables from PDB/LDP to tracers/RTDs, testing of multi circuit temperature controller, installation of earthing material and connection to purchaser's earthing grid, installation of metallic tags, aluminum fixing tape, cable glands & lugs, all other associated materials, etc. as required for process, testing and commissioning of complete system providing construction and all other activities complete as per scope of work/supplies detailed in various sections of the tender document, drawings, specifications, including civil works such as concrete foundations, excavation, disposal of surplus earth, sand, bricks, aligning, levelling, grouting / welding, bolting, riveting, etc. including all labour and materials as per tender document, approved drawings, specifications of this tender and direction of Engineer in charge. | - | - | - | - |
| 1.02 | For Tank 261-TK-2002 | 1 | Lumpsum | - | - |
| 1.03 | For Tank 261-TK-2003 | 1 | Lumpsum | - | - |
| 1.04 | For Tank 261-TK-2011 A | 1 | Lumpsum | - | - |
| 1.05 | For Tank 261-TK-2011 B | 1 | Lumpsum | - | - |
| 1.06 | APPLICATION OF INSULATION FOR ELECTRICAL HEAT TRACED TANKS:
Supply of all materials, application of insulation as applicable on outside surface of tank shell, roof, nozzles, manholes, appurtenances, attachments etc., including supply of all materials and installation of all insulation supports as per Job Specification: C068-261-06-43-IL- S001, applicable standards and completing the work in all respect as per drawings, specifications, standards and instructions of Engineer-in-Charge. Surface preparation and primer application on insulated surfaces is covered under painting Schedule of rate. All materials shall be Supplied by Contractor . | - | - | - | - |
| 1.07 | For tag no 261-TK-2002 & 261-TK-2003
Inner Layer (Rock wool) : 25mm | 2,600 | m² | - | - |
| 1.08 | For tag no 261-TK-2002 , 261-TK-2003 & 261-TK-2011A/B Outer Layer (In Situ PUF) : 50mm | 4,110 | m² | - | - |
| 1.09 | For tag no 261-TK-2011A/B Inner Layer (Rock wool) : 65mm | 3,020 | m² | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_943571.xls
BOQ • 0.39 MB
TECHNICAL_SPECS.rar
Additional Documents • 1.56 MB
eNIT_EHT_INSUL_HPCL_71171_TANKAGE_R.pdf
Tender Documents • 1.38 MB
CORRIGENDUM_II_EHT_INSUL_02.pdf
PDF • 0.53 MB
CORRIGENDUM_I_EHT_INSUL_02.pdf
PDF • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .