Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC being lowest and reasonable | |
| 2 | L2₹44.7 L+₹9.9 L (28.4%)Rejected-Finance BANPURA BATWARA SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹46.5 L+₹11.7 L (33.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹49.4 L+₹14.6 L (41.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
15 Feb 2021, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS BB CANTT SRINAGAR
PROVN OF 02 X LBW AND 01 X SR AND CERTAIN MINOR AND REVENUE WORKS UNDER AGE B/R-II OF GE 864 EWS AT BB CANTT SRINAGAR
2021_MES_413857_1
864/WS-48/2020-21
Open Tender
Civil Works
Item Rate
270 days
BB CANTT SRINAGAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹94,000
Yes
18 Mar 2021
18 Jan 2021
17 Feb 2021
18 Jan 2021
15 Feb 2021
1 Feb 2021
60 days
Amount
S&F anodised aluminium frame for doors, windows, ventilators, partitions, powder coated of any colour (thickness or powder coating not less than 50 micron) with two rebates including joining cleats for fixing etc., complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium door shutter, sliding door shutters / partitions with aluminium section weighing 0.55 Kg/Rm, powder coated of any colour (thickness or powder coating not less than 50 micron) including necessary jointing cleats, glazing clips, rubber neoprene packing, suitable handles (02 Nos) in each door, mortice lock arrangement, hinges, anodised aluminium snap beading, screws etc. panelled (02 Nos), filled with 5mm thick PVC sheet manufactured by Rajshree Indore or technocommercially equivalent or 5.5mm thick frosted glass, fitted with roller, bottom and upper guide channels, complete all as specified and directed by Engineer-in-Charge.
S&F 4mm thick, 600x600mm in size HSPC (High Pressure Steam Cured) pre-metered self embossed, textured designer board, E-board Classic, to be fixed and including GI based powder coated snap grid / section (Make - Armstrong or equivalent as approved by GE), size 600x600mm with main runner 38x24x0.90mm thick, cross tee 28.6x24x0.90mm and wall angle 19x19x0.90mm duly suspended with 4mm dia GI wire hangers 1200mm C/C both ways, fixed with steel dash fasteners or from purlin of the roof with alignment clip including providing provisions for light fittings/fixtures of any size and finally applying two coats of oil bound distemper with preparation of surfaces, complete all as specified and directed by Engineer-in-Charge.
S&F 15mm thick 1st class soft wood Australian wood panelling, fixed with tounged and grouted as wall panelling including fillets fixed on walls and including applying two coats varnishing, polishing and preparation with sneezing, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, shafts, wells, cesspits, manholes, pier holes, sewage line etc. and getting out in any type of soil, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 5.00 above but depth exc 1.50 Mtr but not exc 3.0 Mtr.
Excavation over areas not exc. 1.50 mtr deep and getting out in any type of soil, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 7.00 above but depth exc 1.50 Mtr but not exc 3.0 Mtr.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.50 mtr above ground level, complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in, mass concrete and sunken portion etc., complete all as specified and directed by Engineer-in-Charge.
M&L for RCC (Design Mix) M-25 as in foundations includings rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under reamed piles and mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for RCC (Design Mix) M-25 as in columns, pillars, piers, posts and struts, complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to rough finished sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam and similar work vertical or to batter, complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to rough finished sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 16.00 above but 5mm dia and over upto 10mm dia as in strirrups, spacers and binders etc.
M&L for cement concerte 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in benching, bed plates, copings and the like including necessary formwork and finishing all exposed surfaces, complete all as specified and directed by Engineer-in-Charge.
M&L for rolled mild steel framed work as in doors or gates of channels, angle or other section with gusset plates, rails, rolling wheel, bottom runner, braces, plain plate, chequred plate, hold fast with bracket etc. complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings or steel sheeting or other covering, running rails and guides and hanging, also fastening and fixing complete all as specified and directed by Engineer-in-Charge.
M&L for granite work with 20mm thick slab (of any type), table rubbed and polished, as in steps, window cills, cooking platforms and the like in single piece, set in neat cement slurry and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15mm thick screed bed or bedding layer in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
S&F 25mm bore galvanised steel water tubing, medium grade including short lengths with all fittings such as tees, elbows, sockets, bends, union, nipples, brass nuts and diminishing pieces etc. complete, fixed to walls or ceiling or laid in floors, complete as specified and directed by Engineer-in-Charge.
S&F 20mm bore galvanised steel water tubing, medium grade including short lengths with all fittings such as tees, elbows, sockets, bends, union, nipples, brass nuts and diminishing pieces etc. complete, fixed to walls or ceiling or laid in floors, complete as specified and directed by Engineer-in-Charge.
M&L for preparation of new surfaces of steel or iron of any description, exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engineer-in-Charge.
M&L for broken stone or boulders hardcore of gauge not exc 63mm, deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
M&L 100mm thick plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregates), as in sub base or floor etc., complete all as specified and directed by Engineer-in-Charge.
M&L 75mm thick plain cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregates), as in flooring, complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6.0 mtr mean radius, built in CM 1:6, complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in CM 1:4 on brick work or stone masonry or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) As per site requirement water proofing compound shall be mixed with cement mortor. (b) Water proofing compound shall be measured and paid saperately under respective item.
M&L for 15mm thick rendering in CM 1:6 on brick work or stone masonry or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer and over and including 3mm thick wall care putty, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer, complete all as specified and directed by Engineer-in-Charge.
M&L for rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410-W (Gde-E-250) Quality 'A', complete all as specified and directed by Engineer-in-Charge.
S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers as in roofs, walls etc. with grade of zinc coating 275, complete all as specified and directed by Engineer-in-Charge.
S&F 0.63mm thick plain, galvanised, mild steel sheeting as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc., complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surface, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
M&L 75mm thick plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregates), as in plinth protection, laid in alternate ways (not exc 2.0 Sqm each), finished the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles, 7-8mm thick (square/rectangular), area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, as in floor etc., set and jointed with neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over and including 15mm thick screed in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured tiles of size 450x300mmx7mm thick as on vertical surfaces / skirtings / dados etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick rendering in CM 1:3, complete all as specified and directed by Engineer-in-Charge.
S&F hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick 2nd class hardwood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters, window, ventilator as specified in SSR Part-I (Specifications) (2009) and fitted to chowkats at site, complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick 2nd class hardwood factory made, plain, framed, flush shutter with lock rail and panel of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces, size of rail and stile as per IS:1003 (Part-I), kiln, seasoned and chemically pressure treated, complete all as specified and directed by Engineer-in-Charge.
S&F 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc. and fixed at site, complete all as specified and directed by Engineer-in-Charge.
S&F 300mm size mild steel ordinary rat tail, rod pattern spring including roller plate, complete all as specified and directed.
S&F floor door stopper of aluminium body and tongue anodised with land drawn steel spring overall length of cover plate 140mm, fixed with screw, complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section, 150mm size. complete all as specified.
S&F 150mm long anodised aluminium handle, cast type, complete all as specified.
S&F 100mm size butt hinges, medium weight, cold rolled mild steel.
S&F 250mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or xtruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and directed.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed by Engineer-in-Charge.
M&L 60mm thick glazed coloured, machine pressed precast concrete interlocking paver block of any shape, finished type, confirming to IS-15658-2006, M-35 grade, laid over and including 25mm thick sand cushining and jointed in neat cement slurry with grey cement and no pigment, complete all as specified and directed by Engineer-in-Charge.
M&L for chequered cement concrete tiles of size 200x200x25mm thick, set, jointed and pointed in neat cement slurry with white cement and pigment as in treads / floor etc. over and including 20mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick DPC (damp proof course) in cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) mixed with integral water proofing compound, to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engineer-in-Charge. Note :- Integral water proofing compound shall be measured and paid separately under respective item of BOQ.
Supply only Integral water proofing compound.
S&F 0.50mm thick prepainted galvalume aluminium zinc coating steel GI based corrugated steel sheet of any colour having tensile strength of 550 Mps as in roof covering/caldding to wall, fixed with self taping screws, complete all as specified and directed by Engineer-in-Charge.
S&F 0.50mm thick prepainted galvalume aluminium zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified coloured ceramic tiles, 10mm thick (square), area of each tile not exc 0.36 Sqm as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick in CM 1:6 screed bed or bedding layer, complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified coloured ceramic tiles, 10mm thick (square), area of each tile not exc 0.36 Sqm as in skirtings / dados etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick in CM 1:3 plaster, complete all as specified and directed by Engineer-in-Charge.
S&F sink with drainage board, made of stainless steel 1.0mm thick, kitchen or laboratory with plugs, washers and CP waste coupling and waste pipe including bedding in CM to dwarf wall or including fixing cantilever brackets of suitable size and connecting union to pipe, overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engineer-in-Charge. Make :- Neelkanth / Nirali / Bluestar / Prayag
Moulding of sides of granite slab 16-20mm thick, complete all as specified and directed by Engineer-in-Charge.
S&F aluminium anodised powder coated (Powder coating not less than 50 micron) window and ventilator shutters, side hung type without sash bar shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, hinges, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21, 100mm long (2 Nos), suitable handle (1 No.), complete all as specified and directed by Engineer-in-Charge.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed by Engineer-in-Charge.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore galvanised steel water tubing, medium grade including short lengths with all fittings such as tees, elbows, sockets, bends, union, nipples, brass nuts and diminishing pieces etc. complete, fixed to walls or ceiling or laid in floors, complete as specified and directed by Engineer-in-Charge.
S&F 15mm bore chromium plated bib tap, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, high pressure including CP brass wall flange, screwed for iron pipe, complete all as specified and directed by Engineer-in-Charge.rticular Specifiactions.
M&L for rolled mild steel work in compound girders & stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates including all lattice bars, stiffeners, gusset plates etc. conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed by Engineer-in-Charge.
M&L for lagging to 20mm bore pipe, used in internal water supply or plumbing all round with 25mm thick bonded mineral wool preformed SNAPON section of sensity 144Kg/Cum, confirming to IS-9842, provided with chicken mesh netting 25 gauge 20mm mesh binging wire and reinforecement with plaster of paris, complete all as specified and directed by Engineer-in-Charge.
S&F 1000 Ltrs capacity rotational moulded polythylene water storage tank, tripple layered, white in colour (cylindrical vertical with closed top), hoisted and fixed in position, complete all as specified and directed by Engineer-in-Charge.
S&F ball brass valve, high pressure with polythene float and fly nut, screwed for iron pipe or brass ferrule 20mm bore, complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (salt glazed stoneware / AC / reinforced concrete) of 150/200/300mm bore, set in cement mortar, complete all as specified and directed by Engineer-in-Charge.
Supplying & Laying 150mm bore reinforced concrete pipe, Class NP-2, laid and jointed complete with collars, complete all as specified and directed by Engineer-in-Charge.
Supplying & Laying 200mm bore reinforced concrete pipe, Class NP-2, laid and jointed complete with collars, complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in bed to drain pipes of 200mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6.0 mtr mean radius, built in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class "B" bricks, straight or curved on plain of any radius in half brick thick walls, built in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
M&L for walling of random rubble stone masonary, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 77.00 above but EXCEPT STONE.
M&L for PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete, sub base etc., complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) of any description and in any position, not otherwise specifically provided for, complete all as specified and directed by Engineer-in-Charge.
M&L for Precast cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) in cover slab, set in cement mortar 1:4 with plain faces, complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, as in handles / rungs, complete all as specified and directed by Engineer-in-Charge.
M&L for form work to soffits of suspended slab such as roof slab, floor slab, landings, chajjas and similar work not exc 200mm thick horizontal or sloping, flat rough finished surface of concrete, complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregates) as in foundation, filling in and mass concrete, sub base etc., complete all as specified and directed by Engineer-in-Charge.
M&L for cutting into existing manholes of internal dia of pipe 150mm for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished and re-forming benching as required, complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) as in ground floor and paving, not exc 15cm thick below or above ground level, complete all as specified and directed by Engineer-in-Charge.
Cutting holes into or through in brick walls, built in cement mortar and stone walls, built in cement mortar, exc 150 Sqcm and not exc 400 Sqcm of surface area and making good disturbed surface for matching of existing wall, complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in CM 1:3 with using water proofing compound to sides and bottom of sunken slab, finishing the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. Note :- WPC shall be measured and paid separately under respective item of BOQ.
Roughening surfaces of old concrete by sweepping, clean and washing down with water to remove dust, complete all as specified and directed by Engineer-in-Charge.
S&F 40mm bore GI pipe, medium grade as in spouts projecting at least 10cm clear of the wall, complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound.
S&F in replacement PVC low level flushing cistern 10 Ltrs capacity, valveless, syphonic action type, white with inlet, ball valve, float and handle including brackets, PVC 32mm dia flushing pipe, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement vitreous chine wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe) including PVC seat cover, white, closed pattern with recessed bottom and connection to drain pipe and to flushing pipe, anti-syphonage pipe etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement vitreous china, wash hand basin, flat back of size 630mm x 450mm (Padestal pattern), ivory/superior colour including MS brackets (As required at site) and cutting for and pinning ends including 32mm dia brass CP waste fitting including makng good disturbed surface to match with existing surface, complete all as specified and directed by Engineer-in-Charge.
S&F European vitreous china wash down water closet pan, superior colour including flushing cistern and all fittings, complete all as specified and directed by Engineer-in-Charge. Make :- Cera / Hindware / Parryware Cat Part No. 2004, 2104, 2338 & 2204
S&F in replacement health faucet 15mm dia with 8mm dia 1.00 mtr long flexible tube and wall hook, complete all as specified and directed. Make :- Jaquar Cat Part No. 573 or technocommercially equivalent make in Marc / Hindware
S&F in replacement swan neck cock for sink, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe 15mm bore, complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore stop valve, fancy type, cast copper alloy, chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for union, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement angle valve, fancy type, chromium plated with wall flange, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15mm bore, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified.
S&F in replacement 15mm bore fancy type pillar tap, cast copper alloy with capstan head, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shank and fly nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in replacement 20mm dia CP tubular towel rod, 60cm long between flange, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement sheet glass shelf assembly, consisting of 5.50mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 450mm long with aluminium alloy brackets and guard rail, complete all as specified and directed.
Dismantling of 100/75mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed by Engineer-in-Charge.
Supply & Laying 100mm bore cast iron soil, waste and vent pipe, in any length with or without ears with cement joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge.
Supply & Laying 75mm bore cast iron soil, waste and vent pipe, in any length with or without ears with cement joints, laid in trenches or in floors, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 108.00 above but fixed on walls.
All as per Srl item No. 108.00 above but 50mm bore and fixed on walls.
S&F 100mm bore cast iron sanitary connections, short connections pipe of length upto 300mm, complete all as specified and directed by Engineer-in-Charge.
S&F cast iron oval access door, fixed to 100mm bore pipe, complete all as specified and directed.
All as per Srl item No. 112.00 above but 75mm bore and fixed on walls.
S&F cast iron floor trap with grating to 75mm bore including jointing to waste pipe, fixed in cement concrete 1:2:4, type B-1, complete all as specified and directed.
S&F 100mm bore cast iron bend (any radius), diminishing pieces or tapers, complete all as specified and directed.
S&F stack clamp, made out of 50x5mm flat iron and 16mm dia round iron stays including bolts and nuts and screwing ends of stay to wall or roof, suitable for 110mm bore pipe, complete all as specified and directed by Engineer-in-Charge.
S&F waste coupling of chromium plated, 32mm dia (half or full threaded) (Minimum weight 45gms), complete all as specified and directed.
S&F grating doom 125mm dia of PTMT (Minimum weight 25gms), complete all as specified and directed.
S&F High density polyethylene (HDPE) 32mm dia pipes of pressure rating 6 kgf/Sqcm, complete all as specified and directed.
Taking up or down 15mm bore steel water tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 120.00 above but 20mm bore.
Dismantling water tank and removing to store exc 250 Ltrs capacity but not exc 500 Ltrs capacity, complete all as specified and directed by Engineer-in-Charge.
S&F 500 Ltrs capacity rotational moulded polythylene water storage tank, tripple layered, white in colour (cylindrical vertical with closed top), hoisted and fixed in position, complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. and removal of debris outside MoD land, complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick PCC 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregates) as in floors etc., complete all as specified and directed by Engineer-in-Charge.
M&L for non skid coloured ceramic tiles, 7-8mm thick (square/ractangular), area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick in CM 1:6 screed bed or bedding layer, complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for one light point / fan point, controlled by one switch SP 230 volts with 1.5 Sqmm copper conductor cable (multistranded) PVC insulated FRLS, unsheathed, surface type, drawing in and including PVC casing & caping or PVC conduit 19mm dia, ISI Marked having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes, made out of 1.2mm thick sheet including one coat red oxide primer on internal and external surface covered with 3mm thick hylam brand IS-2036 Marked laminated sheet cover (for mounting switches, sockets, regulators etc.) including 1.5 Sqmm PVC insulated (multistranded) FRLS unsheathed copper conductor earth wire, complete all as specified and directed by Engineer-in-Charge. Make of wire :- Havells / KEI / HPL / Polycab
All as per Srl item No. 128.00 above but for one 3/5 Pin 5 Amps socket outlet point, controlled by one switch on independent board.
All as per Srl item No. 128.00 above but for one 3/5 Pin 5 Amps socket outlet point, controlled by one switch on same board.
M&L for point wiring for one 15 Amps socket outlet, controlled by one switch with 2.5 Sqmm copper conductor cable (multistranded) PVC insulated FRLS, unsheathed, surface type, drawing in and including PVC casing & caping or PVC conduit 25mm dia, ISI Marked having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes, made out of 1.2mm thick sheet including one coat red oxide primer on internal and external surface covered with 3mm thick hylam brand IS-2036 Marked laminated sheet cover (for mounting switches, sockets, regulators etc.) including 1.5 Sqmm PVC insulated (multistranded) FRLS unsheathed copper conductor earth wire, complete all as specified and directed by Engineer-in-Charge. Make of wire :- Havells / KEI / HPL / Polycab
M&L for point wiring complete with PVC insulated and unsheathed, copper conductor cable, multistanded FRLS, single core 1100 volts grade electric cable of size 1.5 Sqmm (nominal area) in and including concealed rigid PVC conduit/casing and caping of suitable size (as per site requirement) and including 1.50 Sqmm PVC insulated & unsheathed copper cable as continuous earth wire with all accessories including lugs required, complete all as specified and directed for one light point or one fan point, controlled by one switch SP 230 volts, complete all as specified and directed by Engineer-in-Charge. Make of wire :- Havells / KEI / HPL / Polycab Note :- Modular white cover plate with frame and metal flush box shall be measured and paid saperately under respective item of BOQ.
All as per Srl item No. 132.00 above but for one 3/5 Pin 5 Amps socket outlet point, controlled by one switch on independent board.
All as per Srl item No. 132.00 above but for one 3/5 Pin 5 Amps socket outlet point controlled by one switch on same board.
All as per Srl item No. 132.00 above but for one bell point controlled by one switch.
All as per Srl item No. 132.00 above but using 2.5 Sqmm single core, multistranded copper conductor PVC insulated and unsheathed FRLS cable for 3/6 pin 15 Amps socket outlet controlled by one switch on independent board with and including 1.5 Sqmm green solid copper conductor cable, PVC insulated FRLS unsheathed as continuous earth wire with lugs. Make of wire :- Havells / KEI / HPL / Polycab Note :- Modular white cover plate with frame and metal flush box shall be measured and paid saperately under respective item of BOQ.
S&F switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and directed. Make :- Anchor / Cona / Standard / SSK
S&F switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and directed. Make :- Anchor / Cona / Standard / SSK
S&F socket outlet 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and directed. Make :- Anchor / Cona / Standard / SSK
S&F socket outlet 2 in 1, 3 pin, 5 & 15 Amps, flush type, complete all as specified and directed. Make :- Anchor / Cona / Standard / SSK
S&F modular bell push, 6 Amps, one way, 1 module, complete all as specified. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F bell electric ding dong type, AC, 230 volts, single pole, complete all as specified. Make :- Anchor / Cona / Standard
S&F modular fan regulator, electronic rotary, 0-4 steps, 100 watt, 240 volts, 50 Hz, hum free, 2 module, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F modular switch 6 Amps, 230 Volts, one way switch, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F modular switch 16/20 Amps, AC, 230 volts, one way, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F modular socket 6 Amps, AC, 230 Volts, 2/3 Pin combined, 2 module, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F modular socket 6/16 Amps, 2/3 Pin combined, AC, 230 Volts, 2 module, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F lamp holder insulated body PVC / Polycarbonate body with back plate suitable for batten fitting, complete all as specified and directed. Make :- Anchor / Cona / Standard
S&F ceiling rose, three terminals, polycarbonate isolated body, complete all as specified and directed. Make :- Anchor / Cona / Standard
S&F modular white cover plate with frame, 2 module and metal flush box 2 module, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F modular white cover plate with frame, 3 module and metal flush box 3 module, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F modular white cover plate with frame, 4 module and metal flush box 4 module, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F modular white cover plate with frame, 6 module and metal flush box 6 module, complete all as specified and directed. Make :- Anchor Roma / Legrand Aretor / Crabtree
S&F stepped type electronic fan regulator, flush type, complete all as specified and directed. Make :- HPL / Cona / SSK
S&F LED light fitting fixture 20 Watt, decorative ultra slim with co-extruded channel in thermally conductive material with plastic housing, heat sink, environmental friendly, energy efficient, ready to use, complete all as specified and directed. Make :- Havells Cat Part No. LHEXBXPNIN1WO20 / Wipro Cat Part No. LL20-221-XXX-65-NE / HPL Cat Part No. HLPT51820PCGCW / Philips Cat Part No. BN021CLED20SPSUCDLGR.
S&F 10 Watt, 6000 K LED bulk head luminaire with opal diffuser etc. complete with accessories, complete all as specified and directed. Make :- Havells Cat Part No. LHEXCGP7PN5W010 / HPL Cat Part No. HLPLEDBH10W(CW) or technocommercially make of Wipro / Crompton
S&F LED 10 Watt (candle/ball type) with B-22 base, complete all as specified and directed. Make :- Havells / Bajaj / Philips / Halonix
S&F round / square surface mounted slim panel LED downlighter with complete diffuser, 18 Watt, complete all as specified and directed by Engineer-in-Charge. Make :- Wipro Cat Part No. LD81-171-XXX-60-SM / Crompton Cat Part No. LCDSPLN-R/S-18-CDL / Havells Cat Pat No. LHEAAVP7IL1W018
S&F 60 Watts LED building security light fitting including suitable bracket and nuts, bolts etc., complete all as specified and directed by Engineer-in-Charge. Make :- Havells / Bajaj / Halonix
S&F 60 Watts LED decorative post top for 360 degree direct light with IP-65 protection light fitting and including suitable bracket and nuts, bolts etc., complete all as specified and directed by Engineer-in-Charge. Make :- Crompton Cat Part No. 60CDL/MOR or technocommercially equivalent make in HPL / Wipro / Halonix
S&F sheet metal enclosure double door for mounting MCBs with 200 Amps rated busbar 4 way AC 240 volts with IP-43 protection including cutting chases to wall for fixing DB and making good the disturbed surface to match with existing surface, complete all as specified and directed by Engineer-in-Charge. Make :- L&T / HPL / ABB
S&F sheet metal enclosure double door for mounting MCBs with 200 Amps rated busbar 8 way AC 240 volts with IP-43 protection including cutting chases to wall for fixing DB and making good the disturbed surface to match with existing surface, complete all as specified and directed by Engineer-in-Charge. Make :- L&T / HPL / ABB
S&F MCB SPN 40 Amps, 240 Volts, 50 Hz, AC, made from moulded self-extinguishing thermostate plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. Make :- L&T / HPL / ABB
S&F MCB SPN 63 Amps, 240 Volts, 50 Hz, AC, made from moulded self-extinguishing thermostate plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. Make :- L&T / HPL / ABB
S&F MCB SP 6-32 Amps, 240 Volts, 50 Hz, AC supply, suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. Make :- L&T / HPL / ABB
M&L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 2x4 Sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in and including PVC conduit / casing & capping and making good the disturbed wall surfaces to match with existing specifications, complete all as specified and directed by Engineer-in-Charge. Make :- Havells / Plaza / KEI / HPL / Paragon
M&L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 2x6 Sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including PVC conduit / casing & capping and making good the disturbed wall surfaces to match with existing specifications, complete all as specified and directed by Engineer-in-Charge. Make :- Havells / Plaza / KEI / HPL / Paragon
M&L for 10 Sqmm 1100 volts grade heavy duty cable PVC insulated multistranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC hseathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
S&F ceiling fan, AC, single phase, 230/240 Volts of size 1200mm sweep including connecting with PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm and hanging arrangements made out of MS clamps with nuts, bolts and washers, complete all as specified and directed by Engineer-in-Charge. Make :- Anchor / Almonard / Havells / Bajaj
S&F ventilating fan, made out of high quality engineering plastic, resistant to colour change with anti-static properties, 250mm sweep, suitable to work on 230 Volts, 50 Hz, AC supply including connecting to ceiling rose, complete all as specified and directed by Engineer-in-Charge. Make :- Havells / Bajaj / Crompton
S&F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts, 3 Phase, 50 C/s, 4 way complete with appropriate size copper busbar and neutral link confirming to Cat Part No. 607913 of Legrand or technocommercially equivalent make of L&T / Standard, complete with one MCCB 3 Pole, 415 Volts, 100 Amps rating with repturing capacity 16 KA and 12 Nos of MCB SP 63 Amps of the same make as of distribution board and including cutting chases to wall for fixing DB and making good the disturbed surface to match with existing surface all as required at site, complete all as specified and directed by Engineer-in-Charge. Note :- Outgoing MCBs will be measured and paid saperately under respective items.
Supply & Laying XLPE insulated armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 70 Sqmm x 3.5 Core, complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm bore GI tubing, light grade for passing cable through culvert / under the floor, along with the pole, complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick, burried directly in ground (Earth pit not less than 3.25 metre deep below normal ground level) with top edge of plate not less than 2.5 mtr below normal ground level, connecting to the galvanised iron earth lead wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth strip, protected by provision of GI pipe, light grade, 40mm bore including provision of cement concrete pit in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore medium grade GI pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal filling test point made out of 40x6mm flat iron with fixing arrangement funnel wire mesh and earth work in hard/dense soil, returning, filling in and removal of surplus soil to a distance not exc 50 mtr, complete all as per electrical plate No. 03 of SSR Part-1 (2009) and connecting to earth test point including testing on completion.
M/S SUHEEL CONSTRUCTIONS
M/S NEW IQBAL ENTERPRISES
M/S Tajamul Ah Buchh
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .