Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹42.6 L+₹4.7 L (12.3%)Rejected-Finance SIDDHARTH CO 24 PADMAVATI SOCIETY VALLABH NAGAR BHURAVAV GODHRA GUJARAT 389001 | PANCH MAHALS | GUJARAT | 389001 | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹46.2 L+₹8.3 L (22.0%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹46.5 L+₹8.6 L (22.7%)Rejected-Finance 12 138 MANAS NAGAR BARA REWA POST OFFICE BANSAGAR COLONY REWA | REWA | REWA | MADHYA PRADESH | 486001 | L4 | Rejected-Finance Being other than Lowest Tenderer | |
| 5 | L5₹47.5 L+₹9.6 L (25.4%)Rejected-Finance | L5 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
3 Mar 2025, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIL KUMAR S GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8172 REPAIR MAINTENANCE OF EARTHINGS LIGHTENING PROTECTION SUBMAIN MCCBs DBs AND CERTAIN EM WORKS AT VARIOUS OTM AND TECHNICAL INSTALLATION UNDER AGE EM I UNDER GE NW KUNJALI
2025_MES_697589_1
8172/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
8 May 2025
12 Feb 2025
5 Mar 2025
16 Feb 2025
3 Mar 2025
17 Feb 2025
12 Feb 2025 - 16 Feb 2025
Amount
Material and labour for earthing in replacement complete with galvanised iron earth plate electrode of size 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with and including galvanised earth strip of size 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20 mm bore galvanised iron pipe (light grade) wire mesh, charcoal or coke and common salt in alternate layer of 15 cm (compacted thickeness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20 mm graded aggregate), 50 mm thick precast RCC (1:2:4) cover slab (re-inforced with 8 mm dia complete all as shown and specified in electrical plate No-5 of SSR part-I of 1991. NOTE:- The unit rate includes earthing lead and protection pipe i.e. GI pipe, light grade, 40 mm bore upto 7.5 metre from top of earth plate.
Material and labour for earthing in replacement complete with galvanised iron earth plate electrode of size 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with and including galvanised earth strip of size 25 x 4 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20 mm bore galvanised iron pipe (light grade) wire mesh, charcoal or coke and common salt in alternate layer of 15 cm (compacted thickeness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20 mm graded aggregate), 50 mm thick precast RCC (1:2:4) cover slab (re-inforced with 8 mm dia complete all as shown and specified in electrical plate No-5 of SSR part-I of 1991. NOTE:- The unit rate includes earthing lead and protection pipe i.e. GI pipe, light grade, 40 mm bore upto 7.5 metre from top of earth plate.
All as per item No 3 above but connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
All as per item No. 3 above but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead complete all as specified and as directed. .
Material and labour in repairs for earth continuity conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed with poles or any other indicated situation for loop earthing etc as required using aluminium strip of size 25 x 3 mm including necessary drilling works, jointing, base insulators etc complete all as specified and as directed.
Material and labour in repairs for earth continuity conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed with poles or any other indicated situation for loop earthing etc as required using galvanised iron strip of size 32 x 6 mm including necessary drilling works, jointing, insulators etc complete all as specified and as directed. Note : The cost insulators for fixing continuity conductor along wall/roof/any other position is deemed to be included in the quoted rate.
All as per item No 6 above but for 25x4mm galvanised iron strip complete all as specified and as directed.
All as per item No 6 above but copper strip 32 x 6mm complete all as specified and as directed.
All as per item No 6 above but for 20x3mm copper strip complete all as specified and as directed.
All as per item No 6 above but for 6 sq mm area aluminium wire complete all as specified and as directed.
All as per item No 6 above but for 25x3mm aluminium strip complete all as specified and as directed.
S&F in repair of 50 Sqmm single core copper cable or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed.
Supply and fix in repairs air termination, single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and as directed.
Supply and fix in repairs air termination, single pointed, copper rod 12mm dia and 300mm long compete all as specified and directed.
M&L in repair test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. head screw complete all as specified and directed.
Supply and fixing in repair GI pipe light grade 40 mm bore complete all as specified and directed.
Supply and fixing in repair GI pipe medium grade 20 mm bore alongwith connected all fittings complete all as specified and directed.
Supply & fix in repair of JEF Nimbus Early Streamer emission Air terminal (ESEAT). ESEAT shall have a corrosion resistant stainless steel body (AISI 316 grade) capable of working in hazardous atmosphere. The Air terminal shall be non-radioactive and require no special licensing. The unit shall be fully autonomous (no battery, no external power supply required ), collect energy from ambient electric field. ESEAT model must be tested in a high voltage laboratory in accordance with NFC 17 102 for a series of 100 shock waves equal to 325µs in order to measure the average gain in triggering. The average gain in triggering time (ΔT) obtained during the lab test for the offered model must be mentioned in the test report. ESEAT must work on negative as well as positively polarized discharges. ESEAT must have been tested for such discharges by a reputed Indian Laboratory like Central Power Research Institute (CPRI). A dedicated tester should be available to test the healthiness of the ESEAT on request ( Courtesy : Page No. 37, Point No. 3 of Clause 8.6 of the Revised NFC 17-102 version 2011 ). ESEAT Model : NLP 2200 - Radius of protection = 30 Mtrs Level of protection considered for the project = Level I.
Supply & fix in repair of Standard / Side mounting / Special Mounting Structure of GI + Aluminium of height 4.5 Mtrs with base plate suitable for roof mounting on concrete base and with FRP adapter without GUY kit complete all as specified and as directed.
Supply and fix in repair test link box in order to disconnect the earth termination system for enabling measurements complete all as specified and as directed..
Supply & fix in repair of 4 Digit electromechanical Lightning Event Counter in WEATHER PROOF ENCLOSURE. The counter should give the number of strikes intercepted by the lightning arrester complete all as specified and as directed..
M&L in repair JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set incl Supply of Eco Friendly weather proof High Density Polyethylene Earth Pit Chamber complete all as specified and as directed. Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Material and labour for repair/replacement of concrete earth pit in PCC (1:3:6) type C-1 (with 20 mm graded aggregate), 50 mm thick precast RCC (1:2:4) cover slab (re-inforced with 8 mm dia complete all as shown and specified in electrical plate No-5 of SSR part-I of 1991 complete all as specified and as directed..
M&L for periodical Servicing & maintenance of Aquaguard of capacity 15/20/50/100 ltrs /hr at site by authorised service provider for smooth functioning of the plant. (Necessary spare parts shall be measured and paid seperately under relevant item here-in- after, however cost of small items like plain washer, spring washer, 3/4'' nut, screw, UV ring, pipe, float valve, inlet fitting, elbow, FR switch etc. shall deemed to be included in the item rate complete all as specified and as directed.
Supply and fixing in replacement the following spare parts of RO Plant capacity 15/20/50/100 ltr /hrs complete to make plant functional/serviceable complete all as specified and as directed. (a) Pump 75/100 GPD. Make - Aquafresh/ Natura/ Aquatic or equivalent
(b) Solinoid Valve complete all as specified and as directed. Make :- Hero/ Aqua Fresh/ Natura
(c) S.M.P.S ( switch mode power supply) complete all as specified and as directed. Make :- Zed Blue/ Brother/ Micro Plus
(d) Ultra Violet Tube complete all as specified and as directed. Make Aqua Grand/ Aqua Fresh Natura
(e) Ultra Violet Barrel complete all as specified and as directed. Make :- Aqua Fresh/ Aqua Guard
(f) Sediment filtercomplete all as specified and as directed. Make Aqua Fresh/ Aquajen/ Natura
(g) Carbon filter complete all as specified and as directed. Make :- Aqua Fresh/ Natura/ Aqua Guard
(h) Membrane 75/100 GPD complete all as specified and as directed.Make :- Dow Filmtec/ Aqua Fresh/ Pentair/ Hi- teCH/Vontron/CSM
(i) Minaral Catridge (active copper) complete all as specified and as directed.. Make Aqua Grand/ Aqua Fresh Natura
M&L for periodical servicing and maintenance of RO plant of capacity 250 ltrs/day, and rectifing the defects including necessary dismantling and taking out for repairing and refixing on site, replacing spares as required . Note : Cost of minoe spares required are included in quoted rate by the contractor.
Supply and fixing in replacement the following spare parts of RO Plant capacity 15/20/50 ltr /hrs complete all as specified and directed. (a) Carbon filter . Make :- Aqua Fresh/ Natura/ Aqua Guard
(b) Membrane of existing capacity complete all as specified and as directed.
(c) Carbon filter complete all as specified and as directed. . Make :- Aqua Fresh/ Natura/ Aqua Guard
(d) Sediment filter complete all as specified and as directed. Make Aqua Fresh/ Aquajen/ Natura
(e) Pump motor not less than 2 hp capacity suitable for or as per existing type complete all as specified and as directed.
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces complete all as specified and as directed.
Taking down old U/S tube light fittings single/Twin ,Reccess is mount fitting , etc and making good the distrubed surface matching with existing surface complete all as specified and as directed.
Taking down old u/s MCB DBs complete with MCBs, isolator etc of any type and capacity from wall/ceiling etc & making good to the disturb surfaces complete all as specified and as directed.
M&L in repair point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly for One light point controlled by one 5A switch complete all as specified and as directed.
All as per item No. 31 but for One Fan point controlled by one 5A switch complete all as specified and as directed.
All as per item No. 31 but for One 5A flush type switch socket point on same board board complete all as specified and as directed.
All as per item No. 31 but for One 5A flush type switch socket point on independent board complete all as specified and as directed.
M&L for point wiring (Work station for computer)complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete necessary electric connection for each workstation point comprising of 03 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/ Plaza
S & F in repairs modular switch 1 way 6A, 1 module all as specified and directed.
S & F in repairs modular switch 1 way 16A, 1 module all as specified and directed.
S & F in repairs modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed.
S & F in repairs modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed.
S&F for modular fan step regulator, 120W - 2 modular all assspecified and directed.
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as specified and as directed.
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408595 or equivalent make in list of manufactures including making connection complete all as specified and as directed.
S & F in replacement of MCB 40 to 63 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and as directed. Make Legrand cat No 408596 or equivalent make in list of manufactures including making connection complete all as specified and as directed.
S & F in replacement of MCB 40 to 63 Amps capacity, C Curve type suitable for 240 volts AC supply,FP with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and as directed. Make Legrand cat No 408792 or equivalent make in list of manufactures including making connection complete all as specified and as directed.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 protection surface mounting SPN 16 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make -Legrand cat No 507613 or equivalent make in list of manufactures. (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make -Legrand cat No 507610 or equivalent make in list of manufactures (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make -Legrand cat No 507610 or equivalent make in list of manufactures (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting TPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make -Legrand cat No 507720 or equivalent make in list of manufactures (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting TPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make -Legrand cat No 507753 or equivalent make in list of manufactures. (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
taking down and M&L for sub-main wiring with 2 runs of 2.5 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing and caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
Taking down & M&L for sub-main wiring with 2 runs of 4.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 3 run of cable and one run of PVC casing caping shall be measured as one unit.
Taking down and M&L for sub-main wiring with 2 runs of 6.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC capping casing not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 3 run of cable and one run of PVC casing caping shall be measured as one unit.
Taking down and M&L for sub-main wiring with 4 runs of 10.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade Caping casing not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 10.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of PVC casing capping :- Precision/ pesto plast / National/Plaza (b) 5 run of cable and one run of PVC casing caping shall be measured as one unit.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 16 sqmm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as specified and directed. Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
All as per item No. 54 above but for cable size 25 sqmm 3.5 core complete all as specified and directed.
All as per item No. 54 above but for cable size 35 sqmm 3.5 core complete all as specified and directed.
All as per item No. 54 above but for cable size 50 sqmm 3.5 core complete all as specified and directed.
All as per item No. 54 above but for cable size 95 sqmm 3.5 core complete all as specified and directed.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10sq mm 4 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed.. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
S &F in repair 20 Watt 4 FT LED tube light fitting integrated Batten T5: Nakshatra series indooor light decorative alluminiumextruded T5 LED Batten-integrated type complete all as specified and directed. Make- C & S CAT PART NO LTTB4F20WLED/W,or equivalent make in list of manufactures
S &F in repair 10 Watt 2FT LED tube light fitting integrated Batten T5: Nakshatra series indooor light decorative alluminiumextruded T5 LED Batten-integrated type complete all as specified and directed.. Make- C & S CAT PART NO LTTB2F10WLED/W ,or equivalent make in list of manufactures
S &F in repair Ceiling light 36 WATT-2ft X 2 ft SURFACE mounted backlit panel,cygnus-cs series surface mounting powder coated with CRCA full glow LED panel:CYGNUS- CS SERIES complete all as specified and directed..make- C&S CAT PART NO-LTCSP36WLED2X2 or equivalent make in list of manufactures
Supply and fixing in replacement outdoor type flexible LED AC rope/striplight 60 Watt, IP67 of any colour as per existing complete all as specified and directed .. Make : Havells cat part No. LHEHCPP1ATA6F075 or equivalent make in list of manufactures
Supply & Fix in repairs LED spot light not less than 12W LED , white/ warm white/Yellow or as per existing, recessed mounted deep adjustible all as specified directed.
Supply and erecting of cast iron 3 to 5 mtr long Heritage type street light pole in repairs with double Arms duly painted duly fixed with 2 x 40 W LED post top light including excavation, earth work, PCC as in foundation, nuts, bolts, washers of any size complete all as specified and directed. Note: Excavation, Earth work, PCC(1:3:6) type C2 foundation and PCC(1:2:4) type B1 coping etc are deemed to be included in the quoted rate. ii) FRP outdoor loop box alongwith 3 pole connector and 06 amps MCB to be included in the quoted rates (iii) The asthetic and design appearance of pole shall be finalised by Engr-in-Charge/GE
M&L for dismantling old u/s pole from site and supply and erection of solar column street light pole with connected solar street light with lithium ferro phosphate battery, solar panel, solar charger built into the luminaries with pressure dia cast aluminium body with efficacy more than 175 lum/watt with capacity not less than 20W complete all as specified and directed by Engr-In-Charge. Make :Bajaj cat part No. BSSL 45M 20W SL or equivalent make in list of manufactures
M&L for dismantling old u/s pole from site and supply and erection of solar column vertical light pole with the column vertial lights attachment for solpole with lithium ferro phosphate battery, solar panel, solar charger built into the luminaries with pressure dia cast aluminium body with efficacy more than 175 lum/watt with capacity not less than 20W complete all as specified and directed . Make :Bajaj cat part No. BSSCL 45M 20W VL or equivalent make in list of manufactures
Supply & Fix in repairs LED spot light not less than 7W LED , white/ warm white/Yellow or as per existing, recessed mounted deep adjustible complete all as specified and directed.
Supply & Fix in repairs LED Slim down light not less than 22W LED , Color temp : 3 in 1, white/ warm white/Yellow or as per existing, LED Round Recess PDC Aluminium Housing Downlights,not less than 5700K light complete all as specified and directed.
Supply and fix in repair drivers for 36 Watt, 2ft x 2 ft surface/recess mounted LED light complete all as specified and directed.
Supply and fixing in replacement of integrated all in one type solar street light with lithium ferro phosphate battery, solar panel, solar charger built into the luminaries with pressure dia cast aluminium body designed for mounting on pole with bracket suitable for tilting at various angles with efficacy more than 175 lum/watt with capacity not less than 40W complete all as specified and directed by Engr-In-Charge. Make : Philips cat part No. BRP710LED40CWMRS1 or equivalent make in list of manufactures
Supply and fixing in replacement of integrated all in one type solar flood light (IP-66) with lithium ferro phosphate battery (25.6V, 30AH), solar panel, solar charger built into the luminaries with pressure dia cast aluminium body designed for mounting on stand/pole with bracket suitable for tilting at various angles with efficacy more than 170 lum/watt with capacity not less than 100W complete all as specified and directed . Note : Cost for material and fixing of required stands for mouting flood lights is deemed to be included in the quoted rate.
Supply and fix in repair aviation light 48 Watt complete all as specified and directed.
siddharth and company (BID ID -3244476)
Shree Ayyappa Engineering (BID ID -3248332)
Rama Construction Co (BID ID -3248091)
Shetty Construction Co (BID ID -3247813)
SHRI SAI ENTERPRISES (BID ID -3247189)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .