Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹46.5 L+₹5.2 L (12.5%)Rejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹49.7 L+₹8.3 L (20.1%)Rejected-Finance VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical MAHAVEER NAGAR BARMER RAJASTHAN 344001 MAHAVEER NAGAR BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | - | Rejected-Technical Not Approved |
Tender Value
₹42.2 L
EMD Value
₹85,460
Closing Date
25 Oct 2024, 6:00 pmClosed
GE (AF) Utarlai
GE(AF) UTARLAI
PROVN OF MOTIVATION SQUIRE , OVERHEAD SHED,EARTHING PIT ,COMMERCIAL POWER SUPPLY AND VARIOUS OTHER SANCTIONED WORK AT AIR FORCE STATION UTTARLAI
2024_MES_676687_1
8547/E8
Open Tender
Civil Works
Item Rate
365 days
UTTARLAI
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Utarlai
₹85,460
Yes
30 Nov 2024
26 Sept 2024
26 Oct 2024
27 Sept 2024
25 Oct 2024
11 Oct 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate as in foundation filling / mass concrete/ sub base floor,complete all as specified and directed.
Removal of excavated soil to a distance n exc 50m depositing where distance at a level n.exc 1.5m heights from starting point.
M & L for block masonry with solid pre-cast cement concrete blocks made out of cement concrete 1: 3: 6 type C-1, using 20 mm graded crushed stone aggregate, exc. 10 cm in width and setting in cement mortar 1 : 6 complete all as specified and directed
M&L for rendering 10mm thick in CM 1:4 on brick/concrete surfaces finished even and smooth without using extra cement all as directed.
M&L for broken stone hardcore of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface as specified
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work on vertical/curved/flat surface on any structure.
M&L for M25,infoundations,including,rafts,footing,foundations beams; plinth beams,bases for columns,etc. basement slabs,under-reamed piles and mass concrete. (20mm graded aggregates) (Up to Ground Level) in war memorial structure
M&L for RCC M-25 (20mm agg.) Columns, pillars, piers, posts and struts of any shape curved /flat/vertical in war memorial structure
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions in flat/curved/vertical shape in war memorial structure etc all as specified & directed
S&F TMT bars (Fe 500),10 mm dia and over in reinforcement cut to length, bent to shape required incl bending spirally cranking, hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified.
M&L 20mm thick granite slab with fully rounded edges on platform, on war memorial structure in any shape such as vertical/curved/flat with adhesive or laid in neat cement slurry over and incl 15mm thick screed bed in CM 1:6 and incl ornamental work on granite such as name engraving on granite complete all as specified and directed by Engineer -in -Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified
M&L PCC 1:3:6 type C-2 (using 40mm graded stone aggregate as in foundation filling / mass concrete,complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, steel conforming to Fe410 - w (Gde - E 250) quality (B), complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410-W(Gde- E-250) quality- B, complete all as specified and as directed.
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S & F Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces of any description, not otherwise described over 10cm width or girth, complete all as specified and directed.
M&L for One coat of synthetic paint for Small articles such as metal switch blocks, metal ceiling roses, articles of builder's hardware such as door springs, hooks, knobs, fasteners, stays, locks, latches, etc., straps to roof trusses, gates and similar articles, when unconnected with other painting or when painted in a different tint at various scattered location in tech & domestic area complete all as s[pecified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil, complete all as specified and as directed.
Returning , filling in soft / loose soil, including spreading, levelling , watering and well ramming in layers n, exc 25cm thick, complete all as specified and as directed.
Removing excavated materials, exc. 250KM but N. exc 500 KM and depositing where directed at a level n, exc, 1.50 m above the starting point, complete all as specified and directed.
M & L PCC1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping or similar work etc including necessary form work complete all as specified and directed.
M&L for Rendering 15mm thick in cement mortar (1:4) on brick walls or concrete surfaces, finished even and smooth without using extra cement , complete all as specified and directed.
M&L for applying two coats of cement base paint on newly plastered surfaces of walls including preparation of new surfaces complete.
Reinforced cement concrete Type B1 1:2:4 (using 20mm graded stone aggrgate) in:-Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, complete all as specified and directed
Reinforced cement concrete Type B1 1:2:4 (using 20mm graded stone aggrgate) Columns, pillars, piers, posts and struts complete all as specified and directed
Reinforced cement concrete Type B1 1:2:4 (using 20mm graded stone aggrgate) Beams, cantilevers beam bressummers, lintels span complete all as specified and directed
Reinforced cement concrete Type B1 1:2:4 (using 20mm graded stone aggrgate) Slabs supported on walls, beams and columns in floors, roofs, andings, balconies, canopies, deck slabs complete all as specified and directed
M &LFormwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors andbeams,
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;exceeding 200mm thick (Horizontal or slopingcomplete all as specified and directed
S&F TMT bars (Fe 500),5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified.
M&L for applying roof treatment on top of roof with APP modified membrane with non woven polyester reinforcement (centre core) shall be laid by torch application method with overlap 100mm on length side and 100mm on width side including a coat of bituminious oil based primer ( IS : 3884) @ 250gm / Sqm weight not less than 3 kg/Sqm complete all as specified and directed
M&L for rendering 10mm thick in cement mortar (1:4) on concrete surface as on roof slab, finished even and smooth without using extra cement mix with water proofing compound as per manufacturer instruction complete all as specified and directed
M&L for preparation of old treated steel surfaces of any description over 10cm width or girth and applying one two of synthetic enamel paint over a coat of red oxide primer in complete all as specified and directed
Earth work in excavation by mechanical means (Hydraulic excavator) means in any kind of soil over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge
Removing excavated material exc, 1.50 km but n exc. 5 km and depositing where directed
Soil stablization of sub grade soil by uniform mixing of cement OPC 43 grade/lime/other additive @ 4% cement by weight of soil ( Percentage of cement/additives for estimation purposes only. Type of additive and, percentage required for blending to be given in mix design) item will include pulverisation of soil, spreading of additives, blending mix by tractor towed rotovator, addition of water/drying of mix to required moisture content and compaction in layers not exceeding 15 cm thick using suitable vibratory roller to required moisture content and compaction using suitable vibratory roller to required 98% Maximum Dry Density. Provisions of IRC SP:89-2010 be referred to for this item.
To carry out test for determine Carry out Field California Bearing Ratio test for proposed subgrade at OGL. As per preocedure laid down in IS-2720 (Part-16) along with determine CBR vaslue and applying suitable corrections. Note : (i) Based on above investigation, the results are to be obtained. The finding would be based on interpretation of results, analysis and computation as per relevant Indian Standards. (ii) Submission of result with detailed report in quadriplicate. (iii) Test to be conducted at restricted area during no flying hours.
S & F SS Railing of grade 304 made of hollow tubes ,channels,plates etc inc welding grinding buffing polishing and making curvature and fitting the same with stainless steel nuts and bolt complete
M & L for 16 to 18 mm thick dholpur stone/ jodhpur stone of any type to work on vertical surface on any structure incl backing coat and fixing arrangement if any as directed by Engr-in -charge.
M&L for shifting of transformer upto 100 KVA from one location to another within a range of 5 Km (Approx) with and including dismantling all electrical and mechanical accessories and refixing the same after completion of shiting & connecting testing complete all as specified and directed. Note: Minor items lugs nut bolt etc requreid for connection after installation are deemed to be included in quoted rates
Supply and erect0Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 ( 11 metres long) complete all as specified and directed.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M & L for Aluminium conductor including streching, steel reinforced on poles complete all as specified and directed by Engineer in charge Note - rate of ACSR conductor deemed to be included in quoted rates
Supply and fix Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
Supply and fix lightning arrestor expulsion type HT 11 KV 10 KA station class with all necessary fittings, transmission class, discharge capicity 65 kiloamp complete all as specified and directed
Supply & install testing and commmissioning of factory made, CPRI approved outdoor LT electric panel ( KIOSK) consisting of double door, weather proof,separate compartment with locking arrangement, cubical panel floor mounting fabricated out of 3.15 mm thick CRCA sheet on angle iron frameof 25x25x5mm and legs made of angle iron 40x40x6mm, painted with seven tank process powder coated and pre coted primer including necessory PCC 1:3:6 type C2 foundation and earth work and comprising the following: (a) Bus bar chamber of 3 phase 4 strip 415 volts with 160 Amps copper strip 1 set (b) MCCB 125 Amp 16 KA 4 pole -01 Nos (c) MCCB 63 Amp 16 KA 4 pole -01 Nos (d) MCCB 40 Amp 16 KA 4 pole -01 Nos (e) MCB 40 Amp C Curve SPN -02 Nos (f) Voltmeter digital 0-500 volt = 01 (g) Amp meter digital 0 -200 Amp = 01 (h) Indicator lamp yellow , Red , blue - 01 Set (j) Complete Int wiring with copper condutor - 1 Lot (k) Extra space for two feeders with MCCb of 63 Amps. Note :(I) All termination of cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
Material & labour for Electrical Earthing with GI plate electrod of size 60 cm x 60 cm x 6 thick burried directly in ground vertically earth pit not less than 2.5 mtr deep below normal ground level with the top edge of the earth plate at a depth not less 1.5 mtr below normal ground level connected to GI strip earth lead of size 32 x 6 mm by means of bolts, nuts, washers made of galvanised iron and connected main control board/switch gear/pannel boards all as specified and shown in Electrical plate No 3 of MES shcedule (SSR) Part-I, 2009 including necessary excavation and earth work in any type of soil, charcoal dust, salt and PCC 1:2:4 type B1 in chambler RCC 1:2:4 type B1 cover slab with 6 mm dia mild steel bars at 100 mm center to center both ways and with 6 mm dia MS hook complete and testing resistence all as specified and as directed. Note:- (i) GI strip 32 x 6 mm upto 7.5 mtr length shall be deemed to include in this items rate. (ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contactor.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 4 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70.0 sq mm 3.5 core
Material and labour for clean dry tibba sand in trenches/ducts for cushoning to cable complete all as specified. (Punned thickness shall be measured & paid)
Supply and laying stone patti 40-50 mm thick, 25-30 cm wide abutting each other for cable protection complete all as specified.
M & L for Stay assembly 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) including PCC complete all as specified and directed by Engineer in charge
Supply and fixing of Recess mounted asthetic LED under canopy luminarie 80W comprises of pressure die cast housing & frame with toughened glass, IP66 protection, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including anti bird spikes fixed on the light fitting complete with fixing arrangement for light at the site all as specified.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core
Material and labour for Boring of holes under road, pavement, hardstanding by trench less technology using ultrasound technique and necessary machine including providing HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply installation and testing of Outdoor type LT junction Box suitable for housing CVT And MCB Box of size approx length 3 feet, Breadth 3 feet Height 3.5 feet total enclousre made up of 3.15mm CRCA sheet, conopy, 25 x 5 mm angular frame through out, double door opening in front and rear with locking arrangement of 12 inch aldrops, 12 lever locks, 1100 volts danger notice board on 4 sides, 7 tank processed powder coated outdoor type epoxy coating of post box red color, four no cable gland plates individually fixed in the bottom, weather proof neoprine gaskets to aviod moisture ingress, necessary PCC founation and earth work complete all as specified and directed.
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with copper plate electrode 60cm x 60cm x 6 mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including copper earth strip 25mm x 3mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. The earthing shall be of inclusive of excavation & earth work in any type of soil/strata, charcoal dust common salt, PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering complete all as specified and directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any additional length shall be paid seperately. (ii) Ontesting after completion, if the desired earth resistance is not obtained, the earthing will be redone at no extra cost by the contractor
S&F in replacement sheet metal powder enclosure powder coated versatile double door single pole and neutral (SPN) distribution board for MCB provisions 230Volt, 50Hz AC supply for 04 way. fitted with copper bus bar rated 200amps, neutral link , earth bar including making good the disturbed surface complete including taking down old DB all as specified.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 40 to 63 AMP of poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP of poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
M&L for Point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5 Sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping (ISI Mark) with all accessories including providing providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3mm thick hylum plastic laminated bakelite sheet top cover for mounting of switches alongwith copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cable of size 1.5 Sqmm as continous earth wire connected to common earth and earth dolly complete all as specified. Make of Cable :- Havells/Polycab/Finolex
One Fan point controlled by one switch 6/5 Amp.
One 3 pin 6/5 Amp socket outlet controlled by one switch indep board.
S&F Switch Socket Combination 2 in 1, 3 pin, 6/5 Amp piano flush type (ISI marked), 240 Volts complete all as specified & directed. Make : Anchor/Havells (Reo)/Kinjal/Kay
S&F Exhaust fan of size 450mm sweep 1400 RPM, iron/steel body heavy duty with louver single phase suitable for 230 volts 50 Hz and connecting up complete including provision of 3 core flexible cord cable of size 27/0.183 from ceiling rose to connector of fan including cutting hole in existing brick/block/stone wall for providing suitable opening on wall and fixing on existing wall with fixing arrangements and making good disturbed surfaces complete all as specified and directed. Make : CG/Bajaj/Havells
S&F Wall mounted swing high speed fan of size 400mm sweep 1350 RPM, single phase suitable for 230 volts 50 Hz and hanging with fixing arrangements on existing brick/block/stone wall and making good disturbed surfaces complete all as specified and directed. Make : CG/Bajaj/Havells
Disconnection and taking down carefully serviceable emergency bell from existing place and shift to another place as directed and reconnecting after fixing on and including suitable size PVC junction box as per sample complete all as specified.
Supply and laying Double wall corrugated HDPE duct pipe 50mm outer dia confirming to IS: 16205 (Part 24) of approved colour with fittings for cable protection complete laid in trenches or fixed on walls with clamps of suitable size all as specified and directed by Engineer-in-charge.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 Sqmm 4 core complete all as specified and directed. Make of Cable : Havells / Polycab / Finolex
S&F in MCB DB CRCA sheet powder coated SPN 8 way double door factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables and flush to wall by making the hole in the wall and fixing the DB with cement work and plastering to match with existing surfaces complete all as specified and as directed.
S&F MCB SPN having braking capacity 10 KA, 35 to 60 Amp, 240 volts 'B' curve complete all as specified and as directed.
S&F MCB single pole having braking capacity 10 KA, 6 to 32 Amps 240 volts 'B' Curve complete all as specified and as directed.
M&L for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC Conduit concealed type of suitable size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly including cutting chases in brick/block/stone wall wherever necessary, replastering and making good to match with existing surfaces complete all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of conduit ISI Marked will be measured as one length. (b) Unit rate includes for cutting chases for cunduits and sunken boxes and making good.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and as directed. Note:- The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
Supply and install 2 TR 5 star rated inverter split air conditioner comprising of indoor & outdoor units, mounting arrangements, SEER 3.2, 100% inner grooved copper tube/condenser, stepless compressor control, working capacity for ambient temp upto 52 degree centigrade, refrigerant gas R-410 (a)/R-32, protection from power fluctuation from 160V to 255V, white colour, manufacturer warranty two years on AC, 10 years on compressor, 5 years on controller/PCB by means of making suitable holes on existing wall of any thickness , any type and making good the surface as per existing complete all as specified and directed. Make : LG/Hair/ L Loyyd/Carrier/Hitachi Note :- Cost of copper tubing of both sizes and copper wire from outdoor unit to indoor unit upto three mtr and installation of AC is deemed to be included in the item rate. If the copper tubing needs extra beyond three mtr will be measured and paid for saperately in relevant schedule of item.
Supply and install 1.5 TR 3 star rated inverter split air conditioner comprising of indoor & outdoor units, mounting arrangements, SEER 3.2, 100% inner grooved copper tube/condenser, stepless compressor control, working capacity for ambient temp upto 52 degree centigrade, filter clean indicator, refrigerant gas R-410 (a)/R-32, protection from power fluctuation from 160V to 255V, white colour, manufacturer warranty two years on AC, 10 years on compressor, 5 years on controller/PCB by means of making suitable holes on existing wall of any thickness , any type and making good the surface as per existing complete all as specified and directed. Make : LG/Hair/L Loyyd/Carrier/Hitachi Note :- Cost of copper tubing of both sizes and copper wire from outdoor unit to indoor unit upto three mtr and installation of AC is deemed to be included in the item rate. If the copper tubing needs extra beyond three mtr will be measured and paid for saperately in relevant schedule of item.
S & F refrigent pipe or tube (Copper) 5/2" / copper cable as per size of AC wiring for Split type AC 1.5 TR/2.0 TR capacity complete all as specified directed by Engr-in- Charge.
Supply and fixing single pole and neutral enclosure with 3 pin earth industrial plug and socket with one MCB SP 20 Amps complete.
Supply and fix Distribution board made out of sheet metal duly powder coated, factory made, enclousure double door type TPN 4 way with 200 amps rated copper bus bar, neutral bar, earth bar, 43 protection fixing of DB flush to wall surface complete all as specified and directed.
Supply and fixing MCBs TPN, 415 Volts 64 Amps, 10 KA B Curve Make : C&S, LEGRAND or Equivalent
Supply and Fixing MCB single pole, 240 volts 32 Amps 10 KA B Curve capacity.Make : C&S, LEGRANDS or Equivalent
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core in wall/floor and making good surface complete all as specified and directed
Supply and fixing GI pipe light grade 50mm dia for protection of XLPE cable under Road/Path/PCC and making good complete all as specified and directed.
S&F for submain wiring complete with two runs of 4.0 sqmm single core multi stranded copper conductor FRLS PVC insulated but unsheathed cabel 1100 volts grade drawn through and including PVC conduit (External) heavy duty 20mm dia including necessary conduit accessories and fittings surface in wall/ceiling etc including sealing threaded joints in conduit accessories with teflon tape including 4.0 sqmm single core multi stranded copper conductor FRLS PVC insulated but unsheathed cabel 1100 volts grade as earth wire. Note : All runs of cables and 1 run of conduit shall be measured and paid as one metre length of unit.
Supply and fixing MCBs TPN pole and neutral, 415 Volts up to 40 Amps, 10 KA B Curve Make : C&S,LEGRAND or Equivalent
M & L for Earthing complete with copper earth electrode 60×60cm ×3mm burried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level connected to and including copper strip of size 20x3 mm by means of nut, bolt, check nut and washer etc made of copper alloy and connection to test point and earth dolly all as shown in electrical plate No. 3 SSR Part I 2009 and specified or indicated including excavation and earth work in any type of soil/ strata PCC (1:3:6) type C-1 in chamber, precast 50 mm thick in cement concrete (1:2:4) type B-1 with CI frame, funnel, GI Pipe 20 mm bore medium grade for watering and 40 mm bore GI Pipe middium grade for protection and test point complete . Note:- (i) Copper strip 20 x 3 mm including GI pipe upto 7.5 mtr length shall be deemed to include in this items rate. (ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contactor.
S&F Copper Strip 20x3. mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground complete all as specified and as directed. NOTE : All Joints should be joined by Brazing
M & L for dismentling of serviceable Split indoor and outdoor units of AC and shifting to new proposed location without damaging any part of the AC complete all as specified and directed.
M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise and making good surface complete all as specified and directed. (Thickness of wall 25 cm)
M&L for installation of split indoor and outdoor units received from item No 1 above, with wall stand etc and charging of gas including testing complete all as specified and directed.
M&L Chemical earthing complete with plate 90x60cmx5mm thick copper plate electrode buried direct in ground vertically not less than 4.70 mtrs deep below ground level with top edge of the plate not less than 3.60 mtrs deep below ground level earth pit size should be 1600mmx1600mmx5000mm with connected to copper strip of size 32x6 mm as earthing lead by means of bolt nut and brazing , check nut and washer all as directed to test point including necessary excavation and earth work (in any type of strata ) and providing alternate compacted layer of 100mm each of charcoal , common salt , magnesium sulphate and all around the plate in continuous layers upto 1.80m height from bottom and below 3.20 m from top as per drg attached & balance pit will be filled with vegetable soil up to ground level including watering pipe GI medium grade of 25 mm dia and 50 mm dia pipe medium grade for earth strip protection up to 7.5 mtr , PCC type C1 chamber , cast iron chamber frame , heavy duty funnel and RCC pit cover all as directed . Copy of drg attached. Note:-(i) Copper strip 32X6 mm including GI tubing 50mm dia beyond 7.5 mtr length shall be paid separatly (ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contactor.
S&F Galvanised Iron Tubing/Pipe 40mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps etc.,complete all as specified and as directed.
S&F earthing pit identifier / marker having tringular plate of base 30 cm & vertical height of 20 cm for equipment earthing pit and writing letters e.g. EQ 1/10 mounted on 25 mm dia GI pipe medium grade project 60 cm above the ground and embeded suitably in concrete PCC 1:2:4 type B2 of size 20 cm x 20 cm x30 cm. The identifier & Earthing pit cover shall be painted with two coat of synthetic enamel paint over a coat of primer and writing letter e.g. EQ 1/10 on the plate and earth pit cover all as specified and directed by Engr-in-Charge.
S&F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x 25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw , complete all as per specified and as directed.
M/s godara infratech and power industries (BID ID -3149746)
m/s jogaram sujaram (BID ID -3149784)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .