Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L3₹27.5 L+₹8.5 L (13.9%)Accepted-AOC QR NO A 1 SECTOR II NALCO TOWNSHIP DAMANJODI ODISHA 763008 | KORAPUT | ODISHA | 763008 | L3 | Accepted-AOC Accepted L1 Rate | |
| 3 | L2₹61.7 L+₹56,955 (0.93%)Rejected-AOC SATSANG BHEJAPUT DAMANJODI KORAPUT ODISHA 763008 | KORAPUT | ODISHA | 763008 | L2 | Rejected-AOC L2 | |
| 4 | L4₹75.0 L+₹13.9 L (22.8%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹1.0 Cr+₹41.4 L (67.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
25 Sept 2023, 3:00 pmClosed
GM,TnC
GM,TnC, NALCO, DAMANJODI
REPAIR AND MAINTENANCE OF TARFELTING, ROOF TREATMENT AND ALLIED WORKS IN ALUMINA PLANT, NALCO, DAMANJODI
2023_NALCO_770346_1
TnC/AR/03/eR-2565
Limited
Miscellaneous Works
Item Rate
730 days
NALCO, DAMANJODI
Not Applicable
7 documents required · 7 mandatory
₹0
₹60,000
Yes
21 Nov 2023
6 Sept 2023
27 Sept 2023
6 Sept 2023
25 Sept 2023
6 Sept 2023
Amount
22.8.1) Providing and laying four courses water- proofing treatment with bitumen felt over roofs/existing R.C.C roof/corrugated CGI, AC sheet roof at all heights consisting of first and third courses of blown bitumen 85/25 or 90/15 applied hot @ 1.45 Kg per square meter of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6mm and down size spread at 0.006 cum per square meter including preparation of surface, making groove of 25 mm, inserting the felt & sealing the joint at required places all complete but excluding grading as per direction of Engineer-In-Charge.Bitumen felt ( hessian base ) type 3 grade I conforming to IS: 1322
22.19.1) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator only. APP 3 mm thick
22.14.1) Providing and laying grading concrete for water proofing treatment with cement concrete 1:2:4 (1cement: 2 coarse sand: 4 graded stone grit of 20mm and down nominal size) and water proofing compound as per manufactures specification and curing all complete as per direction of Engineer-in-Charge. (CEMENT SHALL BE ISSUED FREE OF COST AT NALCO'S STORE ).
12.41.2) Providing of fixing on wall face unplasticised-PVC moulded pipes with all fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS-5382, leaving 10 mm gap for thermal expansion. 110 mm dia meter
Repair of tarfelting defects like balooning, peeled off layers etc. by cutting out the damaged portion by knife or suitable means, application of blown bitumen and fusing of cut edges to bottom layer by heating with blow lamp, laying another layer of blown bitumen to receive new bitumen felt layer ( Hessian base or self finished bitumen felt), laying of blown bitumen for the final layer of stone grit of 6 mm etc. complete the new layer of bitumen felt should be provided with an over lap of 300 mm on all sides & at all heights.
14.1.2) Repairing to plaster of thickness 12mm to 20mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing, plastering the surface of the walls complete at all heights including disposal of rubbish to the dumping ground within 50 metres lead, curing etc all complete with cement mortar 1:4 (1 cement : 4 coarse sand) (CEMENT SHALL BE ISSUED FREE OF COST AT NALCO'S STORE) (Necessary scaffolding shall be erected by the party at his own cost)
Dismantling of old tarfelting from roof at all heights & parapet wall and stacking the dismantled tarfelts within a lead of 100 M including all tools & tackles, labours etc. all complete as per the specification and direction of Engineer-in-Charge.
15.42.3) Dismantling of HCI rain water pipes of standard length at all heights including scaffolding ( if required), cleaning , refixing the same with proper alignment, cement jointing or returning to the Nalco store etc. complete as per direction of Engineer-In-Charge.
15.2.1) Dismantling and demolishing cement concrete work nominal mix 1:3:6 or richer mix including disposal of debris/ dismantled material lead of 50 mtrs. as per the direction of Engineer-in-Charge.
15.7.4) Demolishing brick / other masonry work manually/by mechanical means including stacking of serviceable material and disposal of un serviceable material within 50 mtr lead as per direction of EIC.(IN CEMENT MORTAR)
1.1.1) Removing the excavated materials, surplus earth, dismantled materials, debris of any description any other waste materials, spoil including loading, unloading into trucks/ tractors using baskets by head load or any other means and transporting by mechanical transport and unloading at the earmarked low lying areas, spreading, levelling etc. all complete for the following leads. Removal up to 5 KM within Alumina plant at low lying areas.
Rectification of cracks/grooves in masonary by chipping off the existing plastering, making grooves filling with cement concrete (1:1:2), reconditioning, preparing groove using cement plaster (1:4) on top with 3% approved quality water proofing compound by weight of cement, painting to match as per existing surface complete at all heights with temporary scaffolding etc. complete. (CEMENT SHALL BE ISSUED FREE OF COST AT NALCO'S STORE)
Fixing PVC nozzles in walls/floors of RCC structures and injecting cement slurry mixed with special admixture under pressure through these nozzles to prevent seepage through concrete including finishing and closing the nozzles as per the direction of Engineer-In-Charge. Grout pump is to be used for the grouting purpose. (CEMENT SHALL BE ISSUED FREE OF COST AT NALCO'S STORE)
M/S M H ZAMAN
M/S AMULYA CONSTRUCTION
SAROJA KUMAR SWAIN
Technocrats Construction & Consultancy Services
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_809811.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .