Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-Finance | L1 | Accepted-Finance 1st Lowest | |
| 2 | L2₹23.9 L+₹1.6 L (7.28%)Accepted-Finance | L2 | Accepted-Finance 2nd Lowest |
Tender Value
₹22.3 L
EMD Value
₹44,687
Closing Date
29 Jul 2022, 10:00 amClosed
EE WSD APWD
EE WSD APWD Port Blair
Replacement of old conventional Air conditioners with Ductable Split type centralized units in Conference hall and Seminar hall at TGCE, Port Blair
2022_APWD_6646_1
41/NIT/WSD/2022-23
Open Tender
Air-Conditioner
Works
90 days
Port Blair
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹44,687
18 Aug 2022
15 Jul 2022
29 Jul 2022
15 Jul 2022
29 Jul 2022
20 Jul 2022
15 Jul 2022 - 29 Jul 2022
Amount
SITC of 11 TR ductable Split AC, single circuit,03 ph, 415 Volts unit complete with all components like air cooled condenser , indoor coil unit, blower, Filters, controller, display unit and outdoor copper condensers unit with scroll compressors,fan etc including pressure testing, vacuumising the system, & Installation of all hardware components,hanging on ceiling the IDU with suitable size bolts/brackets etc. as required make:- Hitachi, Model:-Toushi series R410a (or equivalent model in Mitsubishi/ Carrier/ Blue star/Daikin/Fujitsu) as per the instruction of E-in-C.
SITC of 8.5 TR ductable Split AC, single circuit,03 ph, 415 Volts unit complete with all components like air cooled condenser , indoor coil unit, blower, Filters, controller, display unit and outdoor copper condensers unit with scroll compressors ,fan etc including pressure testing, vacuumising the system, & Installation of all hardware components,hanging on ceiling the IDU with suitable size bolts/brackets etc. as required make:- Hitachi, Model:-Toushi series R410a (or equivalent model in Mitsubishi/ Carrier/ Blue star/Daikin/Fujitsu) as per the instruction of E-in-C.
Providing and fixing of refrigerant hard drawn copper pipes of following sizes (Suction & delivery) of split type AC i/c providing electrical cables (4 core 4sqmm), insulation, extra gas charging, cutting, drilling holes on the wall for passing gas pipes , fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish and covering with PVC non adhessive tape over the insulation of refrigerant pipes and as per the direction of E-in-C
Refrigerant pipes of Sizes 7/8" & 1/2"
Supplying and fixing of air ducting fabricated out of GI Sheet confirming to latest IS:655 and complete with dampers, tab hangers, anchor fasteners, vanes, access door, framework etc and complete as required and as indicated below. GI Sheet shall be grade 120 confirming to latest IS:277
Duct with 0.8mm thick GI sheet (22SWG)
Duct with 0.63mm thick GI sheet(24SWG)
Supply & Fixing of air powder coated Aluminium grills/diffusers with / without volume control dampers of following description with necessary frame work complete as required.
Supply Air Ext.Al. Square/rectangular Diffusers with VCD
Return Air Ext.Al. Grilles 0,15,30 &45 deg. deflection without VCD
Supply and fixing of Thermal insulation of following thickness for supply air ducting made of Class 0 endless sheet with self adhesive pre-covered with Alumunium foil,make ARMAFLEX or equivalent, complete as required.
19 mm (code no COA-19mm/EAL +SA)
09 mm (code no COA-09mm/EAL +SA)
Supply and fixing Acoustic insulation of supply air ducting immediately after discharge of packaged unit made of 20 mm thick self adhesive Ductliner sheets make:- ARMASOUND super silence ductliner,code no ASD-SA-140-20 or equivalent, complete as required.
Fabrication and fixing of stand/Pedestal required for out door unit & bracket for AC duct supports made of suitable size MS Angle including painting with anti corrosive primer and metallic paint as required.
Supplying and fixing of following sizes of CPVC plumbing pipe along with accessories for fixing as drain pipe to IDU of ductable split type Air conditioner in surface/recess make: PRINCE SMARTFIT or equivalent including connections using cpvc cement solvent,providing suitable size union in every 03 metres, elbows, Tee, F.T.A etc ,cutting the wall and making good the same in case as required Make: PRINCE SMARTFIT or equivalent.
Making of box enclosure for indoor AHU with 19 mm marine plywood and suitable size M.S Angle framing of size(3m x 2m x 1m),insulating the space inside the enlcosure with Thermacol sheet 12 mm thick for installation of indoor unit of Ductable split Air conditioner, making good the same, painting the enclosure with two coats of wood primer and two coats of enamel paint including removing & re-fixing of existing ceiling boards, carrying out necessary minor alterations in the Alumunium frame works of ceiling wherever required for laying of AC duct, and carrying out necessary replacement of ceiling boards if damaged during duct work etc. as per requirement of site and the instruction of E-in-C.
AKABEA INFRASTRUCTURES PRIVATE LIMITED
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .