Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹33.9 LAccepted-AOC R O ABI GUZAR THE BUND SRINAGAR 190001 J K | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹36.2 L+₹1.2 L (3.55%)Rejected-Finance | L-2 | Rejected-Finance BEING L-2 | |
| 3 | L-3₹39.4 L+₹4.4 L (12.6%)Rejected-Finance | L-3 | Rejected-Finance BEING L-3 | |
| 4 | L-4₹46.5 L+₹11.5 L (32.8%)Rejected-Finance | L-4 | Rejected-Finance BEING L-4 |
Tender Value
₹45.5 L
EMD Value
₹90,900
Closing Date
3 Nov 2022, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
PROVN OF 02 x TOILET AND SPECIAL REPAIR TO BLDG NO P1 TO P5 ASKON NODE PUMP HOUSE T-68 AND WIRING OF BLDG NO T20 T26 AND T33 AT CERTAIN UNITS UNDER AGE BR P AND AGE EM OF GE 861 EWS
2022_MES_556006_1
GE 861 EWS-58/2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹90,900
Yes
21 Nov 2022
4 Oct 2022
10 Nov 2022
4 Oct 2022
3 Nov 2022
20 Oct 2022
Amount
Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone boulder masonry built in cement mortar including all arches quoins etc but excluding ashlar facing, dressed stone work & precast concrete articles etc complete all as specificed and directed.
Demolition of cement concrete (unreinforced) in ground floors & paving n.exc 15 cm thick (below or above ground level) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed.
Taking down chowkat or frame with shutters (without taking shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed.
Taking down of shutter any description area exceeding 1 sqm but not exceeding 2 sqm each complete all as specified and directed.
Dismantling timber scantling unframed 40 sq cm and over in section in any position, complete all as specified and directed.
Dismantling of timber scantling under 40 Sqcm, fixed in any position in fillet rails, posts rafters purlin etc complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets & snap grid frame etc, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting , any gauge and thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar, complete all as specified and directed..
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
Demolition and breaking up 100mm dia drain pipes (Salt glazed ware, AC, PVC or Reinforced concrete) set in cement mortar and removing rubbish from site complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
RCC M-25 design mix using 20 mm graded aggregate in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, etc basements slabs under rammed piles and mass concrete complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate as in beams, cantilevers, bressummers lintels over 1.5 m span complete all as specified and directed.
Form work to sides of concrete foundations, footings, bases of columns, raft beams sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
Form work to sides and soffits of floor or roof beam haunching , lintels, cantilevers shelved including supports overhangs etc also splays between floors and beams, etc complete all as specified and directed.
MS TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed.
MS TMT Bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed.
Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed.
Walling of random rubble masonry with best quality stone, uncoursed, well bonded, bedded and solidly hearted and built in CM 1:6, all as specified.
Precast cement concrete type C-1(using 16mm graded crushed stone aggregate) hollow block masonry with hollow blocks exceeding 10cm in width and setting in mortar 1:6, complete all as specified and directed.
Providing precast cement concrete louvers and jallies, 35mm thick, type B-0 (1:2:4) 12.5mm graded aggregate, (measured solid), including all mouldings but excluding frame, set in CM 1:4, complete all as specified and directed.
5mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 finished the surface even and smooth without using extra cement, complete all as specified and directed.
10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified.
15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 75mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
25mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crused stone aggregate) as in floors to recieve floor finishes, complete all as specified.
50mm thick PCC 1:3:6 type C-2 (40 mm graded stone aggregate) as in sub-floor, sub-base, floor and pavings, etc., complete all as specified and directed.
75mm thick PCC 1:3:6 Type C-2 (40 mm graded stone aggregate) as in sub-floor, sub-base, floor and pavings, etc., complete all as specified and directed.
75mm thick PCC 1:4:8 Type D-2 (40 mm graded stone aggregate) as in ramp, complete all as specified and directed.
100mm thick PCC 1:4:8 Type D-2 (40 mm graded stone aggregate) as in sub-base of floors, complete all as specified and directed.
Cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.06 sqm but not exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Non-skid coloured joint free ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
Glazed ceramic coloured tiles 450mm x 300mm x 6-7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
Chequered coloured cement concrete tiles of size 200 x 200 x 25mm thick, glossy finished, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed.
Rolled mild steel in roof trusses (framed),trussed ,purlins,crane girders,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and directed.
35mm thick, 2nd class hardwood (Sal/ Hollock) factory made, plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneers on both faces. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified and directed.
35mm thick, 2nd class hardwood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, worught, framed rebated on the solid, rounded of chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in ceiling flat and sloping with nails to timber frame, complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in walls with nails to timber frame, complete all as specified and directed.
2nd class softwood, as in scantling and similar work, clean sawn, timber fixed in position, complete all as specified and directed.
2nd class softwood plain fillets square/rectangular or triangular in section of sectional area exc 13 Sqcm but n exc 25 Sqcm, complete all as specified and directed.
2nd class softwood plain fillets bull nosed splayed chamfered or rounded on one edge or face in section of sectional area exc 3 Sqcm but n exc 6 Sqcm, complete all as specified and directed.
2nd class softwood plain fillets bull nosed splayed chamfered or rounded on one edge or face in section of sectional area not exc 3 Sqcm, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plaind steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall and eave boards fixed with self tapping screws, complete all as specified and directed.
250mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
150mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
100mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
150mm long, extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
125mm long, aluminium handles, cast type, anodised, complete all as specified and directed.
100mm long, aluminium handles, cast type, anodised, complete all as specified and directed.
100mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
3mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
3mm thick figured glass pin headed type and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
S & F in repairs sheet glass shelf assembly 12cm wide consisting of 5.5mm thick glass with CP bracket guard and railing 60cm long, complete, all as specified and directed.
Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples,complete all as specified and directed.
Steel water tubing, 15mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Steel water tubing, 20mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Rotational moulded polythylene 1000 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position, complete all as specified and directed.
Rotational moulded polythylene 1000 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20mm brass ball valve high pressure with brass rod & high density plastic ball including dismantlling of existing tank, complete all as specified and directed.
Vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, jointing to flush pipe, complete all as specified and directed.
S&F in repairs vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, jointing to flush pipe including 10 litre PVC cistern, complete all as specified and directed.
Vitreous china, wash hand basin, flat back of size 630mmx450mm with brackets including cutting for and pinning in ends of brackets, complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including 'P' or 'S' trap, seat cover and fixing bolts, flushing cistern and flush pipe including 10 litre PVC cistern & making good to floor in cement mortar M-15 (1:2:4) type B-1 (using 20mm graded crushed stone aggregated), complete all as specified and as directed.
Vitreous china bowl urinal flat back, size 465 x 355 x 265 mm, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with grating and union for discharge pipe, complete all as specified and directed.
S&F in repairs vitreous china bowl urinal flat back, size 465 x 355 x 265 mm, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with grating and union for discharge pipe, complete all as specified and directed.
S&F in repairs vitreous china soap tray, white, size 160mm x160mm x 90mm embedded in the wall, complete all as specified and directed.
S&F in repairs Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour, complete all as specified and directed.
S & F in repair for 125mm size brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe of 15mm dia or union, complete all as specified.
10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets, complete all as specified and directed.
10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets (fixed in repair), complete all as specified and directed.
S&F in repair vitreous china, wash hand basin, white, flat back, of size 550mmx400mm, oval type including cutting for and pinning ends of brackets or erecting stand, waste coupling and waste pipe, complete all as specified and directed.
PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed.
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed.
20mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
S&F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and fixed in pipe etc., complete all as specified and directed.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
15mm bore bib tap, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed.
S & F in repair 15mm bore bib tap, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed.
S & F in repair 15mm bore bib tap with wall flange, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed.
15mm bore stop valve, fancy type, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
S & F in repair 15mm bore stop valve, fancy type, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
15mm bore pillar tap, cast copper alloy, with capstan head, chromium plated screwed down high pressure, with or without lettered hot/cold with long screwed shanks and fly nuts screwed for iron pipe, complete all as specified and directed.
S & F repair 15mm bore pillar tap, cast copper alloy, with capstan head, chromium plated screwed down high pressure, with or without lettered hot/cold with long screwed shanks and fly nuts screwed for iron pipe, complete all as specified and directed.
32 mm dia waste coupling of PTMT (half or full threaded) (minimum weigth 45 gms) complete all as specified.
32 mm dia PVC waste pipe suitable for wash hand basin, complete all as specified.
CP brass soap dish, complete all as specified and directed.
150mm size grating square of PTMT (minimum weight 100gms), complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges, complete all as specified and directed.
S&F in repairs harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc, complete all as specified and directed.
S&F in repairs towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats, complete all as specified and directed.
Supply, fixing, jointing and testing, 20mm bore gun metal globe or gate valve with iron wheel head screwed head both for iron pipe & fixed, complete all as specified and directed.
110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
110mm bore dia PVC (SWR) bends, complete all as specified and directed.
110mm bore pipe PVC (SWR) vent cowl and fixed, complete all as specified and directed.
110mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed.
110mm bore pipe PVC (SWR) 'S'/'P' trap and fixed, complete all as specified and directed.
S&F in repairs 100mm dia outlet PVC (SWR) multi floor trap with openable grating including jointing with solvent cement, complete all as specified and directed.
100mm dia outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
Construction of septic tanks, exc, in ordinary soil, foundation In PCC 1:2:4, brick work in CM 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fiber reinforced cover with angle iron frame Vent shaft and sludge chambers etc., complete for 100 users complete all as specified and directed. Drg No CESZ/TD-01/2015 Sheet 1/3, 2/3.
Construction of soakage well for users, excavation in ordinary soil, foundation PCC 1:3:6 wells of honey combed and solid in M-25 concrete, including intercepting chamber chamber screen chamber, brick work CM 1: 4, RCC cover slab in M-25/ RR masonry filling with brick bats, complete of size 1.80m dia 3.0m deep as shown in drg complete all as specified and directed. Drg No CESZ/TD-01/2015 Sheet 3/3.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint (camoflauge pattern) over a coat of alkali-resistant priming coat, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali-resistant priming coat, complete all as specified and directed.
Complete removal of existing treatment of walls & applying two coats of cement base paint over a coat of alkali-resistant priming coat, complete all as specified and directed.
Preparation of new plastered surfaces of wall to receive 3mm thick wall care putty and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of oil bound distemper over a coat of priming coat and wall care putty, complete all as specifed and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Preparation of old painted wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint to match the existing surface, complete all as specified and directed.
Preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of old painted steel surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
Preparation of new plastered or unplastered surfaces of wall and applying three coats of white wash,complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash,complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-136 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-136 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No-136 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
Switch piano flush button types 16 Amp, single pole, one way complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 Amp flush type, universal, complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
Socket outlet, 3 pin, 6 Amps flush type, complete all as specified and directed.
Modular one way switch 6 Amp, 1 module, complete all as specified and directed.
Modular one way switch 16A, 1 module, complete all as specified & directed.
Modular socket outlet, 6A-2/3 pin combined 2 module, 230 volts complete all as specified and directed.
Modular socket outlet, 6A/16A-2/3 pin combined 2 module, 230 volts complete all as specified & directed.
Modular white cover plate with frame, 3 module, complete all as specified and directed.
Modular white cover plate with frame, 4 module, complete all as specified and directed.
Modular white cover plate with frame, 6 module, complete all as specified and directed.
Modular white cover plate with frame, 8 module, complete all as specified and directed.
Modular fan step regulator, 120W - 2 module, complete all as specified & directed.
Stepped type electronic fan regulator flush type, AC 230 volts, duly ISI marked including connector on the existing sheet etc. as reqd., complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
LED lamp 9/10 W, complete all as specified and directed.
LED lights fitting 1x20W, 4' long, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
S & F in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
12watt 220 volts AC round shape recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking out old, complete all as specified and directed.
15watt 220 volts AC round shape recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking out old, complete all as specified and directed.
LED street light fitting 35 watt 230 V AC outdoor type with high pressure die-cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, complete all as specified and directed.
S & F in repair LED street light fitting 35 watt 230 V AC outdoor type with high pressure die-cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, complete all as specified and directed.
S & F in repair 70 watt LED flood light 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including connecting up with 2.50sqmm copper conductor from junction box to light fitting in non-metallic PVC conduit pipe, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB distribution board , 240 volts TPN, vertical type double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCCB 4 pole, 415 volts adjustable type, 63 Amps with breaking capacity 25 KA complete all as specified and directed.
MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts "B" series capacity of 32 Amps, 10kA and making connections, complete all as specified & directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor (solid), served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10.0 sqmm, complete all as specified and directed.
Supply & fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor (solid), served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10.0 sqmm, complete all as specified and directed.
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., complete all as specified and directed.
Supply & fixing in repair electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. including taking down old unsv, complete all as specified and directed.
Supply & fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC), complete all as specified and directed.
Exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material, complete all as specified and directed.
Supply & fixing in repair exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material, complete all as specified and directed.
Supply & fixing in repair exhaust fan, steel body AC single phase, 230V of size 450mm sweep, heavy duty with blades and frame and louvers including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material, complete all as specified and directed.
Supply & fixing in repair wall fan 450mm sweep, high speed, 230 volts AC single phase, 50 Hz with jerk free oscillation, smooth running, three blades including pull cords and necessary fixing arrangement, complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked incl taking down old unsv, complete all as required at site or directed.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 35 sqmm nominal cross section 3.50 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 25 sqmm nominal cross section 4.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 sqmm nominal cross section 2.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified.
Supply and laying in repairs 50mm dia GI tubing light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 9.0%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
M/S STARE BUILDERS
M/S JAMSHEED ALI CONSTRUCTIONS
NAJAR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .