| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC B 204 2ND FLOOR MANSAROVER GARDEN NEW DELHI 110015 | WEST | DELHI | 110015 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹21.7 L+₹2.9 L (15.6%)Rejected-Finance | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹21.9 L+₹3.1 L (16.7%)Rejected-Finance 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L4₹23.8 L+₹5.0 L (26.5%)Rejected-Finance HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | L4 | Rejected-Finance Other Than Lowest Bidder | |
| 5 | L5₹24.9 L+₹6.1 L (32.3%)Rejected-Finance 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chandigarh
GE Chandigarh N Area Pin-160003
MAINT AND REPAIR TO SEWAGE DISPOSAL SYSTEM IN N AREA UNDER GE CHANDIGARH
2023_MES_622314_1
GE/CHD-59/2023-24
Open Tender
Civil Works
Item Rate
334 days
Chandigarh
Class E category a(ii) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹50,000
Yes
13 Dec 2023
9 Oct 2023
15 Nov 2023
9 Oct 2023
13 Nov 2023
1 Nov 2023
10 Oct 2023 - 16 Oct 2023
Amount
Deploying safaiwala for attending/ clearing daily complaints of blockages of floor traps, gully traps, WC's (Indian/ European) at Ground floor or above ground floors (upto 2nd floor) upto first manhole including cleaning throug door bends with and including necessary T & P required for this purpose. Note :- (a) The contractor shall provide safaiwala, per day for 8 Hrs to attend the above complaints for complete tenure of contract. The quoted rate by the contractor against this item shall deemed to be included the cost of the aforesaid manpower. (b) All the safaiwalas shall attend the MES complaint cell of AGE B/R Army at N area at 08:30 Hrs to collect the complaints and submit the same duly signed by the occupant at 1630 Hrs in the complaint cell. It will be responsiblity of contractor to ensure their attendance & completion of complaints. (c) The contractor will ensure the cleaning/clearing of all the complaints (irrespective of Nos) within 24 Hrs by deploying addl s'walas if needed. Nothing extra will be paid on this account. (d) Contractor shall be solely responsible for supplying all the safety measures required by the safaiwalas during working hours. (e) All the waste material/ sludge shall be disposed off out of MoD land. (f) Contractor shall be solely responsible for supplying all the rodding set/tools required by the safaiwalas during working hours. (g) if contractor failed to fulfill the requirement of safaiwala as required and directed by Engg-in-Charge, Recovery @ Rs1000/- per person per day will be charged.
Dewatering/Desluding of sockage well/septic tank (any size and depth), desilting and removing sludge from manholes as in foul conditons and removing of sludge beyond MD land and deposited in borrow pits including excavation of borrow pits and covered with 10cm thick layers of soil complete all as specified and directed by Engr-in-Charge Note for item No. 2. Dewatering /desludging shall be done by suction pump / any mechanical means and disposal by truck mounted trailors to dispose off sludge etc beyond MOD land earmaked by local Muncipal Corporation
Cleaning of drain pipes of any size by rodding manually or mechanically from manhole to manhole for cleaning and well flushing with water after cleaning . Note: (i) The rate include for taking off manhole cover and re-fixing the same after cleaning /removing the waste materials and sludge near by suitable distance and depositing in the borrow pits as directed by Engineer-in-Charge. (ii) The rates also include for earth work /excavation and removal of surplus spoil for borrow pits.
Cleaning of CI pipes of any size laid in trenches including bends/junction/gully traps etc and removing of sludge if any to a distance exc 50 m and desposting as directed by at site complete all as specified and directed
Cleaning of CI pipes of any size laid in walls including bends/junction/gully traps etc and removing of sludge if any to a distance exc 50 m and desposting as directed by at site complete all as specified and directed
Cleaning of manholes of various size, depth not exceeding 1.5 m including taking off manhole covers and re-fixing the same after cleaning, dewatering and desludging manually or mechanically removing the waste materials and sludge to a distance exceeding 100m and depositing where directed by Engineer-in-Charge in borrow pits. Note: The rates include labour, earth work /excavation and removal of surplus soil for borrow pits all as specified and directed
Cleaning of manholes of various size, depth exceeding 1.5 m including taking off manhole covers and re-fixing the same after cleaning, dewatering and desludging manually or mechanically removing the waste materials and sludge to a distance exceeding 100m and depositing where directed by Engineer-in-Charge in borrow pits . Note: The rates include labour, earth work /excavation and removal of surplus soil for borrow pits all as specified and directed
Excavating in trenches in soft/loose soil, n.exc. 1.5m wide and n.exc 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n.exc. 10 sqm on plan and n.exc 1.5m in depth and getting out.
All as per item No 08 above but exc. 1.5 m but n.exc. 3.00 m in depth
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point.
Demolition and breaking up drain pipes, 150 mm internal dia (Salt glazed stoneware, AC or reinforced concrete) set in cement mortar including haunching and bed concrete.
Demolition and breaking up drain pipes, 200 mm internal dia (Salt glazed stoneware, AC or reinforced concrete) set in cement mortar including haunching and bed concrete.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 150 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 200 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested.
M&L for providing reinforced concrete pipes , claps NP2 laid and jointed complete with collars 150 mm dia (internal) laid in trenches & jointed etc all as specified and by Engr-in-Charge as directed
M&L for providing reinforced concrete pipes , claps NP2 laid and jointed complete with collars 200 mm dia (internal) laid in trenches & jointed etc all as specified and by Engr-in-Charge as directed
Demolition of brick work/stone masonry work built in cement mortar complete etc all as specified and directed by Engr - in - charge.
M&L Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4) complete all as specified.
M&L Brick work using old size bricks (Except Bricks) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:4) complete all as specified.
M&L for rendering 15 mm thick in CM 1:4 on brick masonry surfaces finished even and smooth without using extra cement using WPC etc all as specified and directed Note :- WPC shall be measured and paid separately
Supply only Water proofing compound of ISI marked all as specified and directed
Taking down cement plaster on brick walls or stone walls of any descrition etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
M&L for preparation of surfaces of newly plaster of walls and applying two coats of cement base paint Complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in cills, steps, bands, copings, bed plates, blocks for inserting hold fasts etc. and the like including weathering, slightly rounded or chamfered angles and throating as directed.
M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in surface channels, drains (forming fair finished) complete all as specified and directed by EIC.
S&F in repairs salt glazed stoneware gully traps, 150x150mm square or round mouthed, type P complete all as specified.
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests with 'P; & 'S' trap and including flush cistern and flush pipe complete all as specified and directed.
S & F vitreous china wash down water closet (pedestal pattern) white with, plastic seat cover white and connection to out going pipe & to flushing cistern, sheet cover and flush pipe, anti-syphonage pipe etc as in repair complete all as specified and as directed.
S&F Vitreous China wash basin with pedestal, white, flat back, size 550 x 400 mm, including fixing acessories like galvanised brackets & rag bolts, IN REPAIR, complete all as specified and directed.
S&F in repair 10 Ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including bracketsPVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets fixed in repair complete all as specified.
Dismantling of cast iron/ reinforced concrete/PVC drain pipes, 100/75/50mm, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors 100 mm bore complete all as specified and directed.
S&F Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors 75 mm bore complete all as specified and directed.
S&F Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall 100 mm bore complete all as specified and directed.
S&F Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall 75 mm bore complete all as specified and directed.
S&F Cast iron in repair Bends (any radius), diminishing pieces or tapers (larger bore measured) 75 mm bore with ovel access door complete all as specified and directed.
S&F Cast iron repair Bends (any radius) with duck's foot or heel rest 100 mm bore complete all as specified and directed.
S&F Cast iron repair Bends (any radius) with duck's foot or heel rest 75mm bore complete all as specified and directed.
S&F Cast iron 100 mm bore junction single T equal or unequal with access door fixed in repair complete all as specified.
S&F Cast iron 75 mm bore junction single T equal or unequal with acess door fixed in repair complete all as specified.
Dismantling of PVC (SWR) Pipes/AC pipe of any size and description fixed in wall , jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S & F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified
S & F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified
S & F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with necessary stack clamp complete all as specified and directed
S & F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with necessary stack clamp complete all as specified.
S & F In Repair 75 mm PVC (SWR) bends any radius with acess door complete all as specified.
S & F In Repair 110 mm PVC (SWR) bends any radius with acess door complete all as specified.
S & F In Repair 75 mm PVC (SWR) tee junction any radius with acess door complete all as specified.
S & F In Repair 110 mm PVC (SWR) tee junction any radius with acess door complete all as specified and directed.
PVC (SWR) in repair floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Demolition of cement concrete of any type and any position complete all as specified.
M&L for 75 mm thick Cement concrete type D- 2,1:4:8 (40mm graded aggregate) as in sub base complete all as specified and directed.
Material and labour for factory made Precast RCC man hole covers (type A-1, 1:1½:3, using 20 mm graded stone aggregates), of size 900mm x 600mm x 70mm with plain faces, including MS flat 70x3mm thick frame/ring , set in cement mortar 1:4 complete all as specified.
Material and labour for factory made Precast RCC man hole covers (type A-1, 1:1½:3, using 20 mm graded stone aggregates), of size 600mm x 600mm x 70mm with plain faces, including MS flat 70x3mm thick frame/ring , set in cement mortar 1:4 complete all as specified.
S&F Factory made prepolished vibro compacted chequered tile 25mm thick in required size, shape & colour set jointed and pointed in neat cement sullry with grey cement and pigment over and including 20mm screed bed in CM 1:4 complete all as specified and as directed.
M&L for 60mm thick pre-cast cement concrete (Design mix M-35) grade pre-polished moulded vibratory compacted inter locking paver block coloured of any shape (confirming to ISI-15658-2006) laid over and including 50 mm thick (compacted thickness) sand cushioning and joint filled with sand complete all as specified and as directed.
Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
S&F galvanised iron tubing 15 mm, `medium grade' with all fitting and fixed complete to concealed in walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs Complete.
S&F galvanised iron tubing 20 mm, `medium grade' , with all fitting and fixed complete to concealed in walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs Complete.
Fixing only tubes, any grade, to concealed in walls and ceilings or laying in floors 20 mm, `medium grade' galvanised, with new fittings and fixed complete to walls ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs Complete.
Fixing only tubes, any grade, to concealed in walls and ceilings or laying in floors 15 mm, `medium grade' galvanised, with new fittings and fixed complete to walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs Complete.
Demolition of cement concret/ lime concrete/brick bates of any description and in any thick , any position not otherwise specifically provided for including chaina mozaic, WC etc complete all as specified and as directed.
M&L cement concrete 1:7:12 using 40mm graded aggregate in sunken floor all as specified and directed.
M&L for rendering 15mm thick in cement plaster (1:3) mixed with liquid water proofing compound as manufactures instruction on brick/ concrete surfaces finished even and fair complete all as specified and directed.
M&L for providing and laying 3mm thick APP modified polymer reinforced water proofing membrane with minimum weight of 3.60kg/sqm including appliying bitumenous primer @ 0.30 litre per sqm over cleaned and dry roof surface and parapet, The APP membrane shall be laid using torch application with minimum 10cm side overlap and 15cm end overlap and shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant & The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slope towards rain water pipe outlet complete all as specified and directed.
S&L for 50mm dia GI spout pipe 600mm long embedded in cement concrete 1:2: type B0 using 12.5mm graded stone aggregate complete all as specified and directed.
S&F Low density polythene pipes of dia 50mm bore (LDPE) of pressure rating 6 Kgf/cm2 fixed complete to walls, ceiling or in floor etc. complete all as specified and directed.
S&F single piece WC of size 365x655x765 with flushing cistern and connection pipe, P or S trap (closed pattern incl all necessary accessories like rag bolts, kitt /gel gasket etc, including flushing cistern, pvc seat cover , jet and flush pipe) complete all as specifed and directed.
M&L for Non skid, Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06sqm but not exc 0.11sqm laid as in floors/skirting, set and jointed with cement slurry over & including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with coloured cement to match with surfaces of tiles complete all as specified and in any pattern and shade/colour as directed by Engr-In-charge.
M & L Glazed ceramic coloured tiles in vertical surface 300X 450 X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match . The tiles shall be laid in pattern with two or more colured tile including rendering 10 mm thick on brickwork or concrete surfaces finished even and fair in CM 1:4.combinations all in any pattern and shade/colour as directed by Engr-In-charge.
M&L for Framed work as in greating, manhole cover frame, etc., complete, drilled for fixing of steel sheeting or other covering. including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete complete all as specified.
Demolition of reinforced cement concrete of any type and any position complete all as specified.
M&L for providing precast RCC slabs in CC 1:2:4 type B1 , 1:2:4: (20mm graded stone aggregate) as in manhole cover slabs (for manholes etc) of any size & thickness set in cement mortar 1:6.Note:- (i) The quoted rates shall deemed to include for providing two handles of MS round bars 12mm dia made to shape & of length 65cm long in each cover complete (ii) Reinforcement shall be measured & paid separately.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed.
Paper Powers
KUMAR AND COMPANY
His Construction Company
M/s Super Trading Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .