Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 7TH FLOOR DN 12 SECTOR V SALT LAKE CITY KOLKATA 700091 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700091 | L1 | Accepted-AOC Quoting Lowest Rate | |
| 2 | L2₹21.7 L+₹3.2 L (17.6%)Rejected-Finance 184 187 TEMPLESTEPS BLOCK ANNASALAI LITTLEMOUNT CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L2 | Rejected-Finance Quoted high rate | |
| 3 | Rejected-Technical 327 328 III FLOOR INDRAPRASTH TOWER INDORE | INDORE | INDORE | MADHYA PRADESH | - | Rejected-Technical No response to T.O Memo 163 Dt. 28.01.21 |
Tender Value
₹27.0 L
EMD Value
₹53,972
Closing Date
26 Dec 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,PWD, Electrical Constn. Divn.
New Office Complex Building (5th Floor), Bhabani Bhawan Alipore, Kolkata_700 027
SITC of Lift WBHDCL
2020_PWDE_306058_1
WBPWD/ECD/eNIT04/2020-21
Open Tender
Electrical Work/ Equipment
Item Rate
100 days
Lake Garden
Please refer Tender documents.
3 documents required · 3 mandatory
₹53,972
O/O The EXE. ENGR., PWD, Electrical Constn. Divn.
2 Dec 2021
25 Nov 2020
28 Dec 2020
25 Nov 2020
26 Dec 2020
4 Dec 2020
3 Dec 2020
90 days
Amount
SITC of automatic Machine Room Less (MRL) lift (as per manufacturer design as per detailed spectfication below conforming to IS) and putting into operation after final testing in the existing shaft complete with all accessories and reparing the damaged wall/floor if any etc to complete as required.
Make: OTIS/KONE/SCHNIDLER
Type: Passenger Lift
Load: 6 Passenger / 408 Kg.
Control: Microprocessor based with AC Variable Voltage & Variable frequency (VVVF)
Machine: Energy Efficient Machine ; Gearless without Machine Room.
Speed: 1 M/s
Floor Served: G + 5
Landing: 5; All on same sides (Not stops at 1st Floor)
Total Rise:21.6 Mtr (Approx.) (Bidder should visit the site)
Operation: Microprocessor based simplex full collective with or without attenedent.
Signals: Digital Car postion indicator, car travels direction indicator in car and at all landing with call registration indicator.
Travelling Accuracy: ± 5mm (Micro Levelling Arrangement)
Car Inside: 1000mm (W) X 1050mm (D)/As per manufacturer standerd and approved by EIC
Car Entrance: Clear Opening 700mm (W) X 2000mm (H) protected with car door.
Car Encloser: Stainless Steel Sheet (20SWG) with hair line finish with hand rail.
Car Ceiling & Lighting: Stainless Steel with hair line finish with LED Lighting & Fan.
Car Ventilation: Pressure Fan with anodised Alluminium Grill.
Car Flooring: Decorative Granite Flooring (As per direction of EIC and according to departmental order.)
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system.
Landing Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system.
Door Opening: Automatic Power operated door with full length photocell assembly curtain sensor.
PROTECTIVE DEVICES & OTHER ACCESSORIES
ARD: Automatic Rescue device complete with dry maintenance free batteries as required for automatic evacuation to the neareast floor in case of power failure/single phasing/others.
Over Load Protection: Fully loaded with over load protection. On over loading the lift car will not start withdoor remaining open and audio display indication.
Emergency Lighting In Car: Battery operated emergency lighting in the lift car.
Intercom System: Battery operated InterCom System in Lift Car, Machine Room & Control Room.
Emergency Alarm: Battery Operated alarm bell system in Lift Car & Control Room.
Fireman Switch: Fireman Switch at main landing terminal.
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.
Belt: As per manufacturer's standard conforming to IS.
DIMENSION OF SHAFT & POWER SUPPLY
Available Shaft Dimension: 1650mm X 1550mm
Pit Depth: 1350mm (Bidder should visit the site)
Overhead: 4000mm
Electric power supply: AC 415V, 3Phase, 50Hz terminated in machine room as per IS.
06 Person PWD-friendly Passenger Lift without Machine room and havng same specification as specified in Sl no1.00 to 1.36 except 1.15 & 1.20. In this Lift, Car Entrance- Clear Opening 800mmX2000mm and Car Door- Stainless Steel Center/Telescopic Opening automatic door provided with V3F controlled door drive System with additional features as per PWD Act 1995 (As per following Annexure-I)
Annexure-I ADDITIONAL SPECIFICATION FOR LIFTS AS PER PWD Act, 1995 • The lifts should open to circulation lobbies or corridors at each level with minimal change in illumination level from elevator cab to building space. Elevators should not open to face directly into sunlight and glare. • The lifts shall have minimum internal car dimensions of 2000 mm x 1100 mm wide, with a minimum clear entrance width of 800 mm, and shall have handrails extending to within 150 mm of the corners at the rear and sides of the car. • The top of the gripping surface of the handrails shall be at a height of 850 – 950 mm, with a clear space of 30 mm - 50 mm between the handrails and wall. • The lifts shall be fully automatic with horizontally sliding doors and providing audible annunciation on opening and closing. The essential lift control buttons shall have a minimum dimension of 20 mm and shall be provided within 900-1200 mm above the finished floor level of the car as well as hall.
• Braille and tactile markings shall be placed either on or to the left of the control buttons and shall be in Arabic numerals and/or symbols. Tactile markings shall have a minimum dimension of 15 mm height and be raised 1 mm minimum. • The tactile marking of the push buttons for the main entrance floor shall be identified with a symbol in a star shape. • The emergency alarm push button shall also be in a tactile bell shape. • A detection device shall be provided to reopen the lift doors in the event of hitting any obstacle • The detection device shall be positioned at a height of between 500 mm to 600 mm above the floor of the lift car. • An emergency alarm push button together with a buzzer, an indication light for acknowledgement and an intercom shall be provided in each lift car and be connected to the office of the building manager or caretaker. The office of the building manager or caretaker shall be equipped with a buzzer, indication light(s) (one for each lift) and an intercom connected to the lift car(s).
The indication light for acknowledgement shall be in the form of a blinking light adjacent to the intercom speaker and a notice. When light blinks, it indicates the emergency call has already been received. The sentence Please be patient and wait for the rescue written in Englisg & Bengali shall be provided next to the blinking light. This system shall be powered by an emergency electricity supply system to work in the event of power failure
Note: 1) All the above rates should be quoted inclusive of the all taxes & duties including LWC @1% 2) Total is rounded off to the nearest rupee 3) Rates should be quoted inclusive of cost of maintenance, servicing, supply & replacement of spares for one year from the date of commissioning. 3) @10% of the tendered amount should be submitted by the successful bidder in the form of Bank Guarantee from any schedule bank within seven working days from the date of issuance of LOA, if the accepted bid value is 80% or less of the Estimated amount put to tender
Otis Elevator Company(India)Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .