| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.0 L+₹2.6 L (11.6%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bid | |
| 3 | L3₹26.1 L+₹3.7 L (16.7%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest bid | |
| 4 | L4₹27.4 L+₹5.0 L (22.4%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L4 | Rejected-Finance Being other than lowest bid | |
| 5 | L5₹30.7 L+₹8.3 L (37.3%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
4 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Udhampur
GE (North) Udhampur PIN 901220 C/O 56 APO
REPAIR/REPLACEMENT OF CERTAIN B/R AND E/M ITEMS AT KRIMCHI COMPLEX AND ADJOINING AREA UNDER AGE BR-II OF GE (N) uDHAMPUR
2024_MES_656710_1
GE/U(N)-40/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE North Udhampur
Please refer tender documents
6 documents required · 6 mandatory
₹0
₹40,000
Yes
4 Oct 2024
30 May 2024
6 Jul 2024
30 May 2024
4 Jul 2024
21 Jun 2024
31 May 2024 - 6 Jun 2024
Amount
Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removal of debris outside MD land all as specified and as directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water including removal of debris outside MD land etc complete all as specified and directed by Engineer in charge.
Demolition Stone slabs and tiles laid dry or dry bedded or pointed of any description or thickness in floors, aprons etc complete all as specified and directed by Engineer in charge.
Dismantling floor , hearth or wall tiling including cement mortar bedding ( but not backing ), removing and rubbish off the premises outside MD land complete all as specified and directed by Engineer in charge.
M&L Verified light shade Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
M & L Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like one piece full in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
M & L for Coloured glazed ceramic coloured tiles 350X250X7/ mm x 450X350X7 mm on vertical surfaces of walls as in dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:4 and fair to recive tiles as in skirting/dado etc complete all as specified and directed by Engineer in charge.
S&F non skid ceramic coloured tiles of 7 to 8 mm thick (Square/rectangular) area of each tile exceeding .11sqm but n,exc .18sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 15mm thick screed bed in CM 1:6 complete all as specified & directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles complete all as specified and as directed by Engr-in-charge.
M&L Brick work with sub class 'B' bricks, straight or curved on plan, exceeding 6 meter mean radius built in cement mortar 1:6 complete all as specified.
All as per item No 10 herein before, but except bricks using existing bricks including cleaning etc .complete all as specified and directed by the Engr-in-charge. Note-Old bricks obtained against dismantling/demolition shall be used after properly cleaning.
M&L 10 mm thick rendering on other than fair faces of brick work or concrete surface in CM 1:6 including finishing even and smooth without extra cement all as specified.
M&L for rendering 5mm thick on ceiling surfaces in CM 1:3, complete all as specified.
M&L rendering 15mm thick in CM 1:4 on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing.
M&L Preparation of new plastered surfaces of ceiling and applying three coat of white wash, complete all as specified and directed by Engr-in Charge.
M&L Preparation of new plastered surfaces of wall and applying two coat of oil bound distemper over one coat of primer & 1mm thick wall putty , complete all as specified and directed by Engr-in Charge.
M&L Preparation of new plastered surfaces of wall and applying two coat of cement base paint over one coat of primer , complete all as specified and directed by Engr-in Charge.
M&L for demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and as directed by the Engr-in-charge.
M&L RCC Nominal Mix 20mm graded aggregate (1:2:4) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
M&L for mild steel TMT bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified.
S&F Sink with drainage board made of stainless steel 1mm thick kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets size 25x25x4mm thick and connecting union to pipe, and 125mm Sink Coupling with PVC waste pipe as size required & overall size 915mm x 460mm bowl size 410mm x 330mmx160 mm.
M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed by Engineer in charge.
S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping).
M&L 25 mm thick, Plain cement concrete 1:2:4 type B-1 using 20mmmm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M & L for water proofing treatment to the sunken portion area of each sunken portion with removing of exiting treatment with demolition of existing floor any type up to depth nexc 0.6m including filling of floor with PCC (1:4:8) using 40mm graded aggregate WC & P/S trap and cleaning with wire brush , one coat of bitumen @ 1.7 Kg per sqm , 15mm th plaster in CM 1:4 on all sides portion, one 450mm long 32 mm dia spout .water proofing powder3% mixed by weight of cement. complete all as specified and directed by Engineer in charge.
S & F in replacement WC (Squatt pattern ) including cement concrete bedding , size 580 x 440mm including PVC 'P or s trap front and back inlet and with internal foot rests (excluding flushing cistern ) including flush pipe and connector pieces of PVC and removed old CI Pipe including demolition of PCC up to 450mm depth complete all as specified and directed by Engineer in charge.
S&F in replacement wash basins, vitreous china(flat back or angle back type) size 550 X 400mm,with pedestal height 800mm including cutting for and pinning in ends of brackets or erecting stand including CP waste coupling 32mm and PVC waste pipe 32mm bore complete all as specified and directed by Engineer in charge
S&F continuous piano hinges mild steel, bright finish or electro galvanised with width of flap 30 mm when open.
S & F in replacement Wash down water closet (Pedestal pattern), complete with Pedestal pan and P trap, including connection to drain (or outgoing pipe) and to flushing pipe, antsyphonage pipe, etc. including PVC Seat and cover for pedestal pan and CP Jet alongwith flexible tube/pipe complete all as specified and directed by Engineer in charge.
S&F in replacement PVC low level flushing cistern of capacity 10 ltr. white with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or PVC 32mm dia and connection to pipes complete all as specified and directed by Engineer in charge
S & F in replacement for Vitreous China Urinal, half stall type, white (excluding flushing cistern, flush pipe ) but including urinal spreader with pvc connection 15mm size with PTMT nuts of length 450mm and PVC waste pipe of 32mm bore and CP waste Coupling complete all as specified and directed by Engineer in charge
S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm. complete all as specified and directed by Engineer in charge
S&F in replacement for chromium plated, 15mm Swan Neck pillar cock, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in charge
S&F in repairs Health faucet CP Brass with 8mm dia ,1 mtr long flexible tube with wall hook complete all as specified and directed by Engineer in charge.
S&F jets of EWC's with required size of jet pipe (flexible) and connections etc complete all as specified and directed by Engineer in charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan necks, etc, including cleaning or removal to store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) pipes of bore 110mm single socketed in any length with rubber ring joints fixed to walls/floor with stack clamps and fixed with nut and bolts complete all as specified.
S&F PVC (SWR) pipes of bore 75mm single socketed in any length with rubber ring joints fixed to walls/floor with stack clapms and fixed with nut and bolts complete all as specified.
S&F PVC (SWR) bends with access door any radius of bore 110 mm complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) bends with access door any radius of bore 75 mm complete all as specified and directed by Engineer in charge.
PVC (SWR) branch piece, single (single Y/T) equal or unequal of bore 110mm.
PVC (SWR) branch piece, single (single Y/T) equal or unequal of bore 75mm.
Dismantling water tanks and removing to store exc 250 litre but n exc 500 litre with all necessary fittings complete all as specified and directed by Engineer in charge.
Dismantling water tanks and removing to store exc 500 litre but n exc 1000 litre with all necessary fittings complete all as specified and directed by Engineer in charge.
Supply & Fixing rotational moulded polyethylene water storage tanks 500 ltr Capacity (Cylindrical vertical with closed top) with 20 mm ball valve, epoxy coated aluminum rod, plastic ball etc, hoisted and fixed in position including tank Nipple inlet and outlet and connecting pipes all as specified in SSR Part I complete all as specified & as directed.
Supply & Fixing rotational moulded polyethylene water storage tanks1000 ltr Capacity (Cylindrical vertical with closed top), hoisted and fixed in position including tank Nipple inlet and outlet and connecting pipes all as specified in SSR Part I complete all as specified & as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal from site to store bore of pipe 15mm complete all as specified and directed by Engineer in charge
Taking up or down steel tubing and connections, including cleaning for refixing or removal from site to store bore of pipe 20mm complete all as specified and directed by Engineer in charge
Taking up or down steel tubing and connections, including cleaning for refixing or removal from site to store bore of pipe 25mm complete all as specified and directed by Engineer in charge
Supply & Fixing tubes , medium grade of bore size 15 mm including all fixing accessories and laid in ceilings or laid in floors complete all as specified and directed by the Engr-in-charge.
Supply & Fixing tubes , medium grade of bore size 20 mm including all fixing accessories and laid in ceilings or laid in floors complete all as specified and directed by the Engr-in-charge.
Supply & Fixing tubes , medium grade of bore size 25 mm including all fixing accessories and laid in ceilings or laid in floors complete all as specified and directed by the Engr-in-charge.
Supply and fixing in replacement bib taps long body 15mm chromium plated (ISI Marked with valid CML No) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed including elbow/socket etc as required at site complete all as specified and directed by the Engr-in-charge.
Supply and fixing in repair CP shower with arm 15mm size 195mm long with bend of 45 degree with flange including taking down the existing UNSV shower of any type/shape complete all as specified and directed by the Engr-in-charge.
Supply and fixing in replacement angle cock 15mm chromium plated fitting as required at site and taking down existing unserviceable angle cock complete all as specified and directed by the Engr-in-charge.
Supply and fixing in replacement stop valve Concealed type long shank chromium plated brass fancy screwed down high pressure with crutch or butterfly handle dia 15mm screwed both ends for iron pipe or for unions and fixed including fittings as required at site, complete all as specified and directed by the Engr-in-charge.
S&F in repair Plastic water closet seat cover, white, closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified and directed by the Engr-in-charge.
S&F looking Mirror of size 600mm X 450mm X 5mm thick with Plywood commercial type fixed on back side and wooden frame compete all as specified.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) n.exc 1.5 Sqm each complete all as specified.
All as per item above but exceeding 1.5 Sqm and not exc 4 Sqm each complete all as per specified and directed by engr-in-charge.
Taking down shutters of any description n. exc 1 sqm each complete all as per specified and directed by engr-in-charge.
Ditto as above but exc 1 sqm and n. exc 2 sqm each complete all as per specified and directed by engr-in-charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube in opening as per complete all as specified and directed by the Engr-in-charge.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed .
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by the Engr-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins or spring clips and providing and fixing new clips or pins complete all as specified and directed by the Engr-in-charge.
S&F 3.00 mm thick plain/pin headed/frosted sheet glass, ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed by the Engr-in-charge.
S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples to wooden or steel door/window including wooden beading/nuts & bolts complete all as specified and directed by the Engr-in-charge.
S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by the Engr-in-charge.
S&F 150 mm long aluminium handles, cast type, anodised and fixed complete all as specified and directed by the Engr-in-charge.
S&F 100mm long Steel Butt hinges, heavy weight, cold rolled and fixed complete all as specified and directed by the Engr-in-charge.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by the Engr-in-charge.
S&F floor door stopper of 140mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by the Engr-in-charge.
S&F MS helical door spring 300mm size including roller and roller plate fixed to wooden or steel frames with welding etc complete all as specified and directed by the Engr-in-charge.
Taking down chowkats or frames (without taking off shutters from frame) exc 1.50 Sqm and not exc 4.00 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed by the Engr-in-charge.
M&L for pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified.
M&L for pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete , of frame size 105 x 60 mm, complete all as specified
M&L for factory made, 2nd class hard wood rail and style 35 mm thick, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
All as per item NO. 79 above but glazed and skeleton shutter with sash bar for glass / wire gauge. all as specified & directed by Engr-in-Charge.
Supply and fixing factory made steel windows (Box type) with glazing bars, dovetailed or welded including hinges, steel handles, steel peg stays etc including one shop coat of red oxide zinc chrome primer, fixed as in repairs, complete all as specified & shown in drawings, complete all as specified & directed by Engr-in-Charge.
Supply and fixing factory made steel windows (Box type) without glazing bars, dovetailed or welded including hinges, steel handles, steel peg stays etc including one shop coat of red oxide zinc chrome primer, fixed as in repairs, complete all as specified & shown in drawings, complete all as specified & directed by Engr-in-Charge.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 all as per specified.
S&F 18/19 mm thick prelaminated MDF board, for cupboard shutters and shelves solid core construction, complete all as specified and directed by the Engr-in-charge.
M&L preparing painting on steel surfaces of any description over 10cm in width or girth, on new surface over a coat of red oxidezin primer and two coat of synthetic enameled paint over it.
M&L preparing painting on wooden surfaces of any description over 10cm in width or girth, on new surface over a coat of pink primer and two coat of synthetic enameled paint over it.
Rendering 15mm thick on fair face of brick work or concrete surfaces with CM (1:4) even & smooth w/o using extra cement on roof surface complete all as per specified.
Priming the roof surface with bituminous primer @ 0.3 litres/Sqm and applying a coat of semi hot blown 85/25 grade bitumen @ 1.2 Kg/Sqm and thereafter supply and laying polymeric membrane, five layered, of weight not less than 3 Kg per Sqm with centre layer core of 90 micron high molecular density polyethylene film and bonded completely to the surface with overlap of 10cm (overlap to be thermo fused by flame) followed by another coat of semi hot blown 85/25 grade bitumen @ 0.7 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm including taking down existing membrane sheet incl plastering all as specified and as directed.
Two coats of aluminium paint on roof padding surfaces complete all as specified and as directed.
M&L for water proofing roof treatment, consists of a Atactic polypropylene modified polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyester non woven fabric matt (weight not less than 150 gm/sqm), laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm, with and including priming @ 0.40 lit/Sqm the surface with a coat of hot blown bitumen of grade 85/25 @ 1.2 kg/Sqm each at top and bottom of the membrane as bonding material, including sealing all joints by thermo fusion, complete including removal of existing treatment all as per manufacturer's instructions.
Supply only integral water proofing compound
M&L for rendering 15 mm thick in cement mortor 1:3 with water proofing compound on fair faces of brick work or concrete surfaces on top of roof surface up to G+3 building complete all as specified and as directed.
Machine cut kota stone slab flooring 18-20mm thick over 15 mm thick cement screed in CM 1:4 base and 15-16mm thick and 80mm wide white marble stone border along to wall laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Machine cut Kota stone slab 20-25mm thick in riser with bull nose, skirting, dado and pillar laid over 15 mm thick cement screed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, cutting, rounding edging, and polishing complete
Taking down carefully the existing Copper point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr -in- charge. Note : (i) Old dismantled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as, LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by engineer in charge.
Taking down Old Serviceable/unserviceable MCB& DB any type/size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by engineer in charge.
M&L for Point wiring for One light point controlled by one one way switch 5 Amp with 1.5 Sqmm single core multi stranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia and1.5mm wall thickness ISI marked terminated into annealed steel terminal boxes including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed by the Engr-in-charge.
M&L for point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLS multi stranded copper conductor, medium grade ISI marked drwan into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drwan in to and including surface PVC rigid non metallic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continuous earth wire connected to common earth dolly complete all as specified and directed by Engr-in-Charge.
All as per item No. 99 above but for bell / buzzer on independent board controlled by one push button bell switch.
All as per item Srl No. 99 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge.
All as per item No. 99 above but for one 5 Amps socket outlet on independent board.
All as per item No. 99 above but wire size 2x2.5 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
All as per item No. 99 above but controle by 2 Nos.of two way switch.
M&L for point wring for one light/ceiling fan controlled by one switch with 1.5 sqmm (nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLS in and including concealed PVC conduit 20 mm dia medium duty ISI marked, including suitable new steel sunken boxes, modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface for one light point, fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLS connected to common earth dooly complete including cutting, chasing the surface and then making good the same to match the existing surface and walls complete all as specified and directed by Engr-in-Charge.
M&L for Repair/ replacement of modular white cover plate with frame 2 module as per site requirement. Complete all as specified and directed by Engr-in-Charge.
M&L for Repair/ requirement of modular white cover plate with frame 4 module as per site requirement. Complete all as specified and directed by Engr-in-Charge.
M&L for repair/ replacement of modular white cover plate with frame 6 module as per site requirement. Complete all as specified and directed by engineer -in charge.
M&L for repair/ replacement of modular white cover plate with frame 8 module as per site requirement. Complete all as specified and directed by engineer -in charge.
All as per item No 105 above but for two way point wiring
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge.
S&F Socket out let flush type ,3 pin 6 Amps, all as specified and directed by Engineer- in - Charge.
All as per item No.11 above but wire size 2x2.5 Sqmm to controlled the 3 pin 6 / 16 Amps Modular socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
S&F Switch Modular type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39991/ Havells REO Cat No: AHESXXW201
S&F Socket outlet 2/3 Pin combined 2 module type 6/16 Amp complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39994/ Havells REO Cat No: AHESYXW161
S &F In replacement Modular fan regulator 120 W, 2 module. Complete all are Specified and directed by engineer- in-charge.
S&F in Replacement Switch Socket combination 16A,6Pin , 3 Module complete all as specified and directed by Engineer- in -charge
S&F in repair Socket out let Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
All as per item No. 105 above but for bell / buzzer on independent board controlled by one push button bell switch.
S&F Socket out let flush type ,3 pin 6 Amps, all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Cherry of Ordering Code : 14122/Havells REO Cat No: AHESXXW062
S&F Socket outlet Two in one, 3/5 Pin piano type 6/16 Amp flush type complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39994/ Havells REO Cat No: AHESYXW161
S&F Electric bell Buzzer (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by engineer in charge Make : Havells REO Ordering code : AHELEXW000/ ANCHOR
S&F switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge. Make : ANCHOR Penta Cherry, Ordering Code : 14123/ Havells REO Ordering code : AHEMBKW061
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engineer- in - Charge. Make : ANCHOR Penta Cherry, Ordering Code : 14123/ Havells REO Ordering code : AHEMBKW061
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item No 26
Sub main wiring with two run single core 4 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit/PVC casing & capping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable sub main of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 4 sqmm and one run 4 sqmm cable and one run of PVC conduit shall be measured as one RM
Sub main wiring with two run single core 6 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit/PVC casing & capping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable sub main of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 6 sqmm and one run 6 sqmm cable and one run of PVC conduit shall be measured as one RM
Sub main wiring with two run single core 1.5 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia in PVC concealed conduit/PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable sub main of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 1.5 sqmm and one run1.5 sqmm cable and one run of PVC conduit shall be measured as one RM
Sub main wiring with two run single core 2.5 sqmm FRLS copper conductor cable PVC insulated, 1100V grade including 25mm dia in PVC casing & capping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 2.5 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable sub main of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 2.5 sqmm and one run2.5 sqmm cable and one run of PVC casing and capping shall be measured as one RM
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 4 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD08/ Standard Cat No: DSDNSHODXW08/ Indo Asian Cat No : 810321
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD08/ Standard Cat No: DSDNSHODXW08/ Indo Asian Cat No : 810321
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 12 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD12/ Standard Cat No: DSDNSHODXW12/ Indo Asian Cat No : 810323
Supply and fix VTPN MCCB Double door Distribution Board 04 way 415 volts grade IP 43 Protection Grade with provision for (MCCB) as incoming and Three/single phase (TP/SP) outgoings, complete with insulated bus bar arrangement fixed flush to wall complete including connections should be provide with necessary reducer lugs all as specified and directed by Engr-in-charge. Make : C&S Cat No:CSDBMCCB100DD04IP43S/ Standard Cat No: DSDLVDRBAOFO04/ Indo Asian Cat No : 811888
S & F in repair Thermal magnetic MCCB 4 pole 63 Amps 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB. Make C&S Cat No: CSC2N4/ IndoAsian Cat No: 830022/ or equivalent makes to Standard
S & F in repairThermal magnetic MCCB 4 pole 100 Amps 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB. Make C&S Cat No: CSC2N4/ IndoAsian Cat No: 830022/ or equivalent makes to Standard
S & F in repair Thermal magnetic MCCB 4 pole 125/160 Amps 415 Volts 16ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB.Make C&S Cat No: CS3A4/ IndoAsian Cat No: 830095 / or equivalent makes to Standard
S&F in repair connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domestic loads incl necessary copper lugs etc all as specified and as directed by Engr-in-Charge. Make C&S Cat No: CSMBS2C40/ IndoAsian Cat No: 810078/ or equivalent makes to Standard
S&F in repair 'C' series MCB SP 6-32 Amps. Make C&S Cat No: CSMBS1C6 to CSMBS1C32/ IndoAsian Cat No: 810078/ or equivalent makes to Standard
S&F in repair 'C' series MCB SP 40 Amps. Make C&S Cat No: CSMBS1C40/ IndoAsian Cat No: 810060/ or equivalent makes to Standard
Fixing only serviceable MCB SPN/SP any capacity obtained from item no 03 as above all as specified and as directed by engineer in charge.
Fixing only LED tube light fittings of 5w/12W/20W/2'x2' panel light and LED bulk head fitting 9W as obtained from Srl item No-02 above complete with all afixing accessories.
S&F in repair LED light fitting with high output diffuser 1 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by engineer in charge.
S&F in repair LED light fitting mirror type with high output diffuser 2 feet, 10 /12 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by engineer in charge.
S&F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by engineer in charge.
S&F in repair LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded aluminium body with diffuser complete with testing all as specified and directed by engineer in charge.
S&F in repair surface/recessed mounting LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by engineer in charge. Make Crompton & Greeves
S&F in repair surface/recessed mounting LED warm light fitting POLARIS PAN NIO-III,PANEL 2'x2' PLR 36 FO-ww ,35/36 watt LED environmental friendly , new generation , aesthetically designed ,ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong /grid /ceiling all as specified and directed by Engr-in-charge Engr-in-Charge. Make - Havells /CG/ Wipro
Supply and fixing round/Square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete
S&F in repair surface/recessed mounting LED down lighter round/square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F in repair LED Garnet 20Watt LED Street light 6500 K as per sample fixed in repair complete all as specified and as directed by engineer in charge.
S&F in repair for MCB TPN 63 Amp, 415 Volts- C curve of 10kA Make : C&S Cat No: CSMBS3C63N/ IndoAsian Cat No 810098/ Havells
S&F in repair Metal clad Plug socket single pole enclosure with two pin earth plug and socket with one single 20 Amp , 240 volts MCB complete all as specified and directed by Engr-in-Charge.
S&Fin repair Switch Piano flush type single pole two way 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Cherry of Ordering Code : 14122/Havells REO Cat No: AHESXXW062
S&F in repair Switch Piano flush type single pole 5 Amps one way fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Cherry of Ordering Code : 14121/ Havells REO Cat No: AHESXXW061
S&F in repair switch piano flush type for bell Push 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : ANCHOR Penta Cherry,Ordering Code : 14123/ Havells REO Ordering code : AHEMBKW061
S&F in repair Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 14119/Havells REO Cat No: AHEKSWW063
S&F in repair Socket outlet Two in one, 3/5 Pin piano type 5 Amp/ 15 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39994/ Havells REO Cat No: AHEKYXW163.
S&F in repair Switch Piano type single pole 16/20 Amps One way, fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39991/ Havells REO Cat No: AHESXXW201
S&F in repair Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39998/ Havells REO Cat No: AHETOXW204
S&F in repair Switch socket combination box type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39998/ Havells REO Cat No: AHETOXW204
S&F in repair Switch socket combination box type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39998/ Havells REO Cat No: AHETOXW204
S&F in repair /replacement modular metal flush box 1/2 module complete all as specified and directed by Engr-in charge.
S&F in repair /replacement modular metal flush box 4 module complete all as specified and directed by Engr-in charge.
S&F in repair /replacement modular metal flush box 8 module complete all as specified and directed by Engr-in charge.
S&F in repair Ceiling rose, 3 terminal, PVC / polycarbonate, isolated body fixed in replacement, complete all as specified and directed by Engineer - in - Charge. Make: Anchor Ordering Code : 39072/ Havells REO Cat No: AHEEIXW000
S&F in repair Electronic type fan regulator Stepped type, 240 Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : ANCHOR Penta Cherry, Ordering Code : 14123/ Havells REO Ordering code : AHEMBKW061
S&F in repair Electric bell(Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed by engineer in charge. Make : Havells REO Ordering code : AHELEXW000/ ANCHOR
S&F in repair Modular fan step regulator 120W 02 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular switch 01 way 06A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular switch 01 way 16A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular bell push flush type 6A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular socket, 6A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular socket, 6A/16A-2/3 pin, 02 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair 3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
S&F in repair 3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
M&L for disconnecting all Electrical connection from MCB DB TPN/Wall Mounted Panel Box for reconnecting the same with providing proper Copper Bottle Lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire complete all as specified and directed by engineer in charge. Note : Replacement Burnt out MCBs of any type/size may be measured and paid separately under relevant Items
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase all as specified and directed by Engineer in charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
M&L for Cutting of hard standing n.exc 45 Cm depth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing all as directed .
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the Engr-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Supply and fixing LED street light fitting 25/35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed.
Supply and fixing of Rigid non metallic PVC conduit medium grade, 25 mm dia (external) inclusive of all fittings such as tees, bends, elbow, reducers, Junction box, with modular sheet cover, bell mouth tube ends etc and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed. (For Telephone wiring)
Supply & fixed in Repair MCCB 3pole, 415 V, fixed type ,125 Amps with breaking capacity 16 A,all as specified and directed by Engr-in-charge.
Supply & fixed in Repair MCCB 4 pole, 415 V, fixed type ,160 Amps with breaking capacity 36 KA, all as specified and directed by Engr-in-charge.
S&F in repair/Replacement of capacitor 2.5/3.15 mfd suitable for operate ceiling fan 1200/1400 mm sweep complete all as specified and directed
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated alumimiun conductor served with an inner sheeting of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 core. Nominal cross section in service connection.
Supply and lay in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing.
Supply and lay in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing.
Excavation in trenches in any type of soil n exc 1.5m deep and not exc 1.5m wide for laying of underground cable, electric pole and getting out complete all as directed.
Returning filling in including spreading leveling watering and well ramming 25cm in thickness in any type of soil.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
M&L for dry sand cushioning to underground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt all as specified and directed.
M&L GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia.
takashdeep traders
M/S IMTESH BHAT
KUMAR CONSTRUCTION CO
M/S JANDIAL ENTERPRISES
TULSI RAINA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .