Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-Finance | L1 | Accepted-Finance Accepted as 1st Lowest Bidder for the subjected work | |
| 2 | L2₹1.9 L+₹30,390 (19.0%)Accepted-Finance | L2 | Accepted-Finance Accepted as 2nd Lowest Bidder for the subjected work | |
| 3 | L3₹2.1 L+₹45,765 (28.6%)Accepted-Finance | L3 | Accepted-Finance Accepted as 3rd Lowest Bidder for the subjected work |
Tender Value
₹2.2 L
EMD Value
₹4,400
Closing Date
15 Sept 2021, 4:00 pmClosed
Executive Engineer, KPDCL, ED-2nd, Rajbagh
Office of the Executive Engineer, KPDCL, ED-2nd, Rajbagh, Srinagar
Creation of 100 kVA, 11/0.433 Sub-Station alongwith laying of HT/LT network at NawchiBagh, Parraypora, Sub-Division Baghat in order to relieve critically overloaded existing Sub-Station - (Key Materials shall be Provided by the Department)
2021_PDD_133666_1
ED-II/13 of 2021-22 Dated 06/08/21
Open Tender
Electrical Works
Turn-key
15 days
nawchibagh, parraypora, Sub Division Baghat
Please refer Tender documents.
3 documents required · 3 mandatory
₹200
Ex. Engineer,KPDCL,ED2nd Credited to MH 0801 Power
₹4,400
23 Sept 2021
9 Aug 2021
17 Sept 2021
9 Aug 2021
15 Sept 2021
10 Aug 2021
9 Aug 2021 - 10 Aug 2021
Amount
Installation, Testing and Commissioning of 100 kVA, 11/0.433 KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2/Reclaimed (Aluminium Wound) (DT shall be Provided by the Department)
Erection of ST Poles 9 Mtr (ST-410 SP33) including loading from Stores at Bemina, Carriage and Unloading upto site including site carriage also (Poles shall be Provided by the Department)
Erection of ST Poles 8 Mtr (ST-410 SP15) including loading from Stores at Bemina, Carriage and Unloading upto site including site carriage also (Poles shall be Provided by the Department)
Laying, Stringing and Commissioning of 0.03 ACSR Conductor including loading from Stores at Bemina, Carriage and Unloading upto site including site carriage also (Conductor shall be Provided by the Department)
Laying, Stringing and Commissioning of 0.05 ACSR Conductor including loading from Stores at Bemina, Carriage and Unloading upto site including site carriage also (Conductor shall be Provided by the Department)
Supply, Installation and Commissioning of Gapless Surge Arrestor, 9 kV, 10 kA, LA with polymer/porcelain housing, Stn. Type
Supply, Installation and Commissioning of 11 KV Horn Gap Fuse Set 3-Phase 200 Amp (porcelain type)
Supply, Installation and Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type comprising of 9 No. insulators, pipes and lock pad etc complete job (porcelain type)
Providing and Fixing of Galvanized Ch. Iron X-Arm 8.5' long x 07 No. (75x40x6mm) duly fabricated
Providing and Fixing of Galvanized Ch. Iron X-Arm 8.5' long x 02 No. (100x50x6mm) duly fabricated
Providing and Fixing of Galvanized Angle Iron Brace 10 ft x 2 no. (50x50x6mm) as Transformer Belt
Supply, Laying, Testing and Commissioning of 120 mm sq 1-Core, 1.1 KV grade XLPE Unarmoured Cable FRLS Type as per approved specifications
Providing and Fixing of Aluminium Thimbles 120 mm sq (heavy duty)
Providing and Fixing of Solderless Clamp suitable for 100 kVA (heavy duty)
Providing and Earthing of Sub-Station -- (Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm) for connection of Transformer Body, G.O Set & Lightening Arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of rickmasonary with RCC slab cover.
Providing and Fixing of Anti-Climbing Device with Clamps
Supply, Installation, Testing and Commissioning of 160 Amp MCCB TPN (Adjustable Type) with breaking capacity 36 kA, alongwith Enclosure (as per approved specifications) and galvanized angle iron stand duly grouted
Providing and Fixing of 11 KV Danger Plate with Clamp
Providing and Fixing of Pole Collars of 50x8mm Flat Iron (GI) with galvanized nuts and bolts
Providing and Fixing of Galvanized Ch. Iron Cross Arm 6'3'' long (75x40x6mm) X 03 No. duly fabricated
Providing and Fixing of Galvanized Angle Iron 5'6'' ft x 03 No. (50x50x6mm) duly fabricated
Providing and Fixing of Galvanized Ch. Iron Cross Arm 4 ft long (75x40x6mm) X 02 No. duly fabricated
Providing and Fixing of Galvanized Angle Iron 2'6'' ft x 02 No. (50x50x6mm) duly fabricated
Providing and Fixing of F-Top fabricated of (GI) Channel Iron (75x40x6mm) 1.5' long and of 6'' horizontal length with galvanized nuts and bolts
Providing and Fixing of 11 KV Polymeric Composite Pin Insulator 12 kV, 5 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm complete in all respects as per REC Standards
Providing and Fixing of Bobin Insulators 40 mm
Providing and Fixing of Galvanized Nuts and Bolts of Sorts
Providing and Fixing of GI Wire 8 SWG
Providing and Fixing of LT Shackle Insulator 16 KN with GI nuts and bolts
Providing and Fixing of GI Muki Clamp of 50x8 mm flat iron with end inner dia 18 mm for Shackle Insulators suitable for ST Pole 8 mtr long
Providing and Fixing of 11 kV Polymeric composite Disc Insulator 12 kV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm with fittings
Providing and Earthing of ST Poles 9 mtr long complete by GI pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI strip
Providing and Earthing of ST Poles 8 mtr long using GI Wire 8 No. having 115 turns
Providing and Painting of ST Poles With 1 coat of Red Oxide and 2 coats of Aluminium Paint
Providing and Cement Bottoming of ST Poles in 1:2:4 Mix upto 1/6th plantation depth of pole below ground, 9'' above ground, circular with radius 6'' around the pole girth/surface, top surface tappered outwards as per REC Standards (0.5 cum/pole)
WAZA ELECTRICALS
M/S BS TECHNO POWER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .