| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹73.0 L+₹13.5 L (22.7%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹87.2 L+₹27.7 L (46.6%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹87.5 L+₹28.0 L (47.1%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹88.5 L+₹29.0 L (48.8%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L5 | Rejected-Finance Not being lowest tender |
| Sl No | Description | Qty | Unit | MV Engineers And Contractors L7 | mayur enterprises L5 | Rajindera Enterprises L4 | M/s JAIMAA ASSOCIATES L1 | DS CONSTRUCTION L3 | M/s Birja Nand L2 | Vijay Electricals L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out Old vintage HT 33 KV UG cable of size 300 sqmm 3 core for rerouting at site from trench/pole complete all as specified and directed.
(Location- Near Rangsala-275 RM,Tigris road via salvage Depot to DGNCC gate -500RM) | 775 | RM | 300 ₹2,32,500 | 400 ₹3,10,000 | 150 ₹1,16,250 | 80 ₹62,000 Lowest | 200 ₹1,55,000 | 300 ₹2,32,500 | 200 ₹1,55,000 |
| 2.00 | Supply, laying, jointing and testing in replacement of XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of sizes 3 Core, 300 Sqmm,33 KV grade (earth) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed.
(Location- Near Rangsala-275 RM,Tigris road via salvage depot to DGNCC gate -500RM) | 775 | RM | 2,900 ₹22,47,500 | 3,500 ₹27,12,500 | 3,500 ₹27,12,500 | 1,950 ₹15,11,250 | 2,800 ₹21,70,000 | 2,000 ₹15,50,000 | 1,000 ₹7,75,000 Lowest |
| 3.00 | Material & Labour in replacement of complete jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 Sqmm complete all as specified and directed. | 4 | Each | 45,000 ₹1,80,000 | 16,000 ₹64,000 | 25,000 ₹1,00,000 | 16,000 ₹64,000 | 15,000 ₹60,000 | 31,000 ₹1,24,000 | 8,000 ₹32,000 Lowest |
| 4.00 | M&L in replacement of bore earthing 150 mm dia, depth 20 mtr below ground level using earth electrode 50 mm dia GI pipe medium grade duly drilled hole of 12 mm dia 15 cm C/C on both side of the pipe including lowering in bore well upto the depth of 19 mtr and one mtr above the ground level the pipe electrode should be filled around commercial salt charcoal dust/Breeze and magnesium phosphate of 30 cm layer each upto the full length of pipe. The bore well should have 06 mtr of length 150mm dia MS pipe for protection of bore well Welding of GI strip 50 x 6 mm on earth electrod GI pipe 50 mmdia upto the 20 mtr below ground level 15 mtr from the bore well to test point. Necessary water connection by GI steel tubing light grade10 mm dia complete all as specified and directed.
Note :- GI strip more than 30 mtr will be measured and paid separetely. | 4 | Each | 65,000 ₹2,60,000 | 45,000 ₹1,80,000 | 50,000 ₹2,00,000 | 18,000 ₹72,000 | 1,50,000 ₹6,00,000 | 40,000 ₹1,60,000 | 800 ₹3,200 Lowest |
| 5.00 | Taking out Old vintage HT11 KV UG cable of size 300 sqmm 3 core for rerouting at site from trench/pole complete all as specified and directed. ( Loc :- At Rangsala khyber to SFC-500RM, At rain water harvesting budha chowk Shankar Vihar to CAMS -150 RM, SV to VRC-150 RM, SV to Anuj Vihar-150RM) | 950 | RM | 260 ₹2,47,000 | 100 ₹95,000 Lowest | 150 ₹1,42,500 | 180 ₹1,71,000 | 100 ₹95,000 Lowest | 300 ₹2,85,000 | 200 ₹1,90,000 |
| 6.00 | Supplying, laying, testing and connecting in replacement / rerouting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing of size 300 sqmm, 3 core cable complete all as specified and directed. ( Loc :- At Rangsala khyber to SFC-500RM, At rain water harvesting budha chowk Shankar Vihar to CAMS -150 RM, SV to VRC-150 RM, SV to Anuj Vihar-150RM) | 950 | RM | 2,200 ₹20,90,000 | 2,200 ₹20,90,000 | 2,300 ₹21,85,000 | 1,490 ₹14,15,500 Lowest | 2,050 ₹19,47,500 | 1,600 ₹15,20,000 | 2,300 ₹21,85,000 |
| 7.00 | Supply and fix in replacement of cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm to 300 sqmm 3 core | 8 | Each | 6,500 ₹52,000 | 5,000 ₹40,000 Lowest | 10,000 ₹80,000 | 7,000 ₹56,000 | 6,000 ₹48,000 | 15,000 ₹1,20,000 | 8,000 ₹64,000 |
| 8.00 | Taking out Old vintage HT11 KV UG cable of size 185 sqmm 3 core for rerouting at site from trench/pole complete all as specified and directed by Enge-in-Charge. (Location :-SV to DRDO at Rain water harvesting near budha chowk-150RM, ) | 150 | RM | 190 ₹28,500 | 100 ₹15,000 Lowest | 150 ₹22,500 | 180 ₹27,000 | 200 ₹30,000 | 150 ₹22,500 | 2,000 ₹3,00,000 |
| 9.00 | Supplying, laying, testing and connecting in replacement / rerouting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with 185 Sqmm, 3 Core multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed (Location :-SV to DRDO at Rain water harvesting near budha chowk-150RM, ) | 150 | RM | 1,800 ₹2,70,000 | 1,500 ₹2,25,000 | 1,600 ₹2,40,000 | 1,050 ₹1,57,500 | 1,600 ₹2,40,000 | 1,600 ₹2,40,000 | 1,000 ₹1,50,000 Lowest |
| 10.00 | M & L in replacement of cable jointing kit for HT 11 KV (E) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core 185 sqmm XLPE cables complete all as speicfied and directed. | 2 | Each Job | 6,500 ₹13,000 | 5,000 ₹10,000 | 3,500 ₹7,000 Lowest | 7,000 ₹14,000 | 10,000 ₹20,000 | 15,000 ₹30,000 | 5,000 ₹10,000 |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
4 Aug 2025, 6:00 pmClosed
HQ CWE (U) Delhi Cantt-110010
HQ CWE (U) Delhi Cantt-110010
CALIBRATION OF RELAYS BREAKERS 33 KV GIS PANEL AT SHANKAR VIHAR SUB STATION REPAIR REPLACEMENT OF WORN OUT SPARES OF 33/11KV SWITCH GEAR HT 33/11KV CABLE 110V/52V/24V BATTERY BANKS MAINTAIN TO OUTDOOR TRANSFORMER CT PT LA LINE DIFFRENTIAL RELAYS PR
2025_MES_719193_1
CWE (U)/D-20/2025-26
Open Tender
Civil Works
Works
270 days
HQ CWE (U) Delhi Cantt
Please refer Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (U) Elect Supply
₹1.6 L
Yes
30 Sept 2025
8 Jul 2025
11 Aug 2025
8 Jul 2025
4 Aug 2025
29 Jul 2025
Amount
Taking out Old vintage HT 33 KV UG cable of size 300 sqmm 3 core for rerouting at site from trench/pole complete all as specified and directed. (Location- Near Rangsala-275 RM,Tigris road via salvage Depot to DGNCC gate -500RM)
Supply, laying, jointing and testing in replacement of XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of sizes 3 Core, 300 Sqmm,33 KV grade (earth) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed. (Location- Near Rangsala-275 RM,Tigris road via salvage depot to DGNCC gate -500RM)
Material & Labour in replacement of complete jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 Sqmm complete all as specified and directed.
M&L in replacement of bore earthing 150 mm dia, depth 20 mtr below ground level using earth electrode 50 mm dia GI pipe medium grade duly drilled hole of 12 mm dia 15 cm C/C on both side of the pipe including lowering in bore well upto the depth of 19 mtr and one mtr above the ground level the pipe electrode should be filled around commercial salt charcoal dust/Breeze and magnesium phosphate of 30 cm layer each upto the full length of pipe. The bore well should have 06 mtr of length 150mm dia MS pipe for protection of bore well Welding of GI strip 50 x 6 mm on earth electrod GI pipe 50 mmdia upto the 20 mtr below ground level 15 mtr from the bore well to test point. Necessary water connection by GI steel tubing light grade10 mm dia complete all as specified and directed. Note :- GI strip more than 30 mtr will be measured and paid separetely.
Taking out Old vintage HT11 KV UG cable of size 300 sqmm 3 core for rerouting at site from trench/pole complete all as specified and directed. ( Loc :- At Rangsala khyber to SFC-500RM, At rain water harvesting budha chowk Shankar Vihar to CAMS -150 RM, SV to VRC-150 RM, SV to Anuj Vihar-150RM)
Supplying, laying, testing and connecting in replacement / rerouting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing of size 300 sqmm, 3 core cable complete all as specified and directed. ( Loc :- At Rangsala khyber to SFC-500RM, At rain water harvesting budha chowk Shankar Vihar to CAMS -150 RM, SV to VRC-150 RM, SV to Anuj Vihar-150RM)
Supply and fix in replacement of cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm to 300 sqmm 3 core
Taking out Old vintage HT11 KV UG cable of size 185 sqmm 3 core for rerouting at site from trench/pole complete all as specified and directed by Enge-in-Charge. (Location :-SV to DRDO at Rain water harvesting near budha chowk-150RM, )
Supplying, laying, testing and connecting in replacement / rerouting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with 185 Sqmm, 3 Core multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed (Location :-SV to DRDO at Rain water harvesting near budha chowk-150RM, )
M & L in replacement of cable jointing kit for HT 11 KV (E) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core 185 sqmm XLPE cables complete all as speicfied and directed.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil) for laying of cables or GI pipe and getting out including levelling of bottom suface to required level complete all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed.
Supplying and laying in replacement reinforced precast concrete cable cover, class HV, type 2 with peak size 450mmx 230mm x 50mm complete all as specified and directed.
Laying only old HT cable cover (450mmx 230 mm x 50mm) obtained from excavation complete all as specified and direcetd.
Supplying and laying in replacement of un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.
Laying only old HT cable cover (300mmx 180mm x 40mm.) obtained from excavation complete all as specified and direcetd.
Returning filling in, including spreading, levelling, watering and well ramming (soil) in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed
M&L for ON load / ON line Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 33 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed. Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately .
Supply and topping up of transformer oil of approved quality as per IS :335(2018) having dielectric strength of 45-60 KV in 2.5mm gap for filling in OLTC & for topping up in transformer as required complete all as specified and directed.
M&L for replacement earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below groundlevel) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip of size 32x6mm upto 7.5 Mtr length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
M & L for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole HT structure/ 33 KV yard and etc , outside area of HT installation and removing all rubbish to a distance not exceeding 50 m as directed at site.
Supply in replacement of Current Transformers draw type 11kV, 400/200/1-1, Core1: Class 5P10, 10VA, Core2: Class 0.5, 10 VA .
Suplying and fix in replacement of sub station electrical insulation mat of size specification as per IS 15652 2006 as specified and directed for the following
11 Kv size 2 Mtrx1 Mtrx2.5mm thick.
33Kv size 2 Mtrx1 Mtrx3mm thick.
Supply only rubber hand gloves ISI Marked suitable for working on HT 33/11 KV.
Material and labour for servicing of HT control panel including outdoor CT, PT and relays in control panel of outdoor breaker of capacity 1250 Amps and rating 36 KV complete details mentioned as under:- Details of servicing of HT Panel (breaker) :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iv) Checking the contact for wear. Replace if the contact piece has worn out. (v) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (vi) Check for rust and wear. (vii) Checking of spring charge mechanism (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (ix) Check for loosened connections, rust, damaged lead wires. (x) Checking of control circuit & tighten the connections if any.
M&L for Servicing & Repairs to Air-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petrolium jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed. (Note:Spare parts will be paid under respective items)
Supplying and fixing in replacements, male/moving contact/ rotating blade of HDE copper silver plated of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc complete all as specified and directed.
Supplying only in replacements, Fixed Contacts, made of HDE copper, silver plated, of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc. complete all as specified and directed.
Supplying ,fixing , testing of master trip relay in replacements , 24 Volt DC in control panel including wiring complete as directed at site.
Supplying ,fixing , testing of master trip relay in replacements ,110V Volt DC in control panel including wiring complete as directed at site.
Supplying ,fixing , testing of master trip relay in replacements ,50 Volt DC in control panel including wiring complete as directed at site.
Supplying ,fixing , testing of Trip circuit supervision relay in replacements, 50/24 Volt DC in control panel including wiring complete as directed at site.
Supplying ,fixing , testing of DC supervision relay in replacements, 50/24 Volt DC in control panel including wiring complete as directed at site.
Supplying and fixing PT fuse for 11 KV/110 V PT complete as directed at site.
Supply and fix in replacement Digital volt meter 0-15 KV in HT 11 KV VCB panel working on auxilary supply of 110V including associated wiring, if reqd, complete all as specified and directed.
S&F in replacement of PG clamps aluminium cast alloy suitable for ACSR conductor suitable for (weasel / panther ) for straight connections/ cross connections of type( as per conductor) 33 kv yard with GI nuts, bolts etc complete all as specified and directed.
Material and labour for Preparation of old painted surfaces of 33 KV yard including all steel structures/ frame/gate of bus bay at Grid at an height of 10 mtrs to 15 mtr from GL consisting for 5 nos isolator per bay CT and PT and VCB supporting structure by brushing/cleaning stains, greasy spots with thinner, applying two coats of spray painting of existing colour (synthetic enamel paint) with spraying machine in the yard including all safety measures complete all as specified and directed.
Material and labour for Preparation of old painted surfaces of fencing of 33 KV yard shankar vihar grid by brushing/cleaning stains, greasy spots with thinner, applying two coats of painting of existing colour (synthetic enamel paint) in the yard complete all as specified and directed.
Supply and fix in replacement of silica gel breather assembly complete with breather unit and silica gel including connecting with proper rubberised gasket and necessary fittings GI fittings for fixing/assembling upto 1000KVA transformer complete by removing the unserviceable silica gel breather assembly complete all as specified and directed.
Supply and installation in replacement Anti-condensation space-heater withThermostatic control in cable and circuit breaker compartments of HT switchgears complete all as specified and directed.
Taking out of heavy duty cooling fan ,3 phase, 50 Hz of size 18" form power transformer 33/11 KV of capacity 8/10 MVA ,servicing of the fan by opening including cleaning, greasing , replacement of defective spares parts such as bearing/ bushing, capacitor, canopy, clamp, blade, etc with new one and painting of fan body with synthetic enamel paint and re-assembling in same position after repairs and testing complete all as specified and directed. Note :- (a) The cost of spare parts deemed to be included in quoted rates . (b) Rewinding of the fan will be measured and paid separately under respective item of schedule here-in-after.
S & F in replacement of hooter complete with switch etc suitable for warming HT 11 KV VCBs internal chambers
S & F in replacement of Exhaust fan 450 mm sweep heavy duty with heavy duty bearings , balanced blades/louvers single phase supply complete with acessories all As specified and as directed.
Opening of the VCB , 11 KV 400 to 2000 Amps of any make by removing of the Breaker from the existing position after disconnecting all the connections from the system, servicing, Overhauling of the same, checking of the same for proper operation, spring charge, charged control cables are fastened tightly to the terminals, any abnormality, VCB, cleaning the surface of the insulators, fasten the bolts, checking and correcting interrupting units, mechanism, linkages etc, fasten the hardwares of control wiring, check that the split pins, Circlips, dowell pins etc. have not come out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vaccum pots/chambers is within limit including opening of the shutters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reassembling, control limit switches reconnecting of the breaker for smooth functioning all as directed.
Decarbunizing/cleaning complete HT cable ougoing/Incoming circuit of CTs & PTs, 3 phase, cleaning with CTC and ensure proper decarburizing, re-fixing the same after applying backtol (Red) solution to the spout, checking all the connections, tightening the nuts, bolts thimbles for incoming and outgoing system complete, as specified and directed, rate quoted is inclusive of bactol red, CTC & cotton waste provided by contractor.
Material and labour for testing and calibration of 11 Kv HT Panel Complete as mentioned under - (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (ii) DC Supply supervision relay. (iii) Master trip relay Note:- (I) DC Supply for relay testing shall arranged by the contractor.
Supply,laying,jointing,testing and connecting in replacement of OFC cable,armoured 12 core including earth work for laying of HDPE duct for OFC complete all as specified and directed.
M&L in replacement of HDPE duct of size 40 mm, PN 6 manufatured as per IS-4984 & ISO-4427standards in PE-63 grade including earth work for laying of HDPE duct complete all as specified and directed.
S&F OFC joint enclosure HDPE type suitable for 12 core armoured optical fibre cable including splicing,isopropyle alcohol for clening complete all as specified and directed.
Material and labour for preparation of old painted surfaces of floor mounted indoor/outdoor type transformer 8/10 MVA capacity by cleaning/rubbing with course cloth wire brushes to remove dust deposits oil grease and repainting by applying one coat of spray paint with synthetic enamel paint of approved colour without disturbing/damaging the electrical net work system/equipment including making of capacity /rating /incoming outgoing details in capital english alphabet of size all as specified and directed.
M&L for splicing work of optical fibre cable of 6/12 core for connection at fibre optic distribution box complete all as specified and directed.
S&F patch cord having any type of connectors (SC/LC/ST/FC) at both ends as per site requirment complete all as specified and directed.
S&F in replacement OFC 12 LIU port complete all as specified and directed.
Supply, fixing and testing in replacement of the 33 KV current Transformer shall be paper impregnate oil immersed type,single phase 50 HZ confirming to IS:2705/1992 ( Part I,II,III & IV) with latest amendment in all respect except where ever modified in this specification:- Note: CT should be matched with existing (a)Normal system voltage (KV rms) 33 KV (b) Highest system voltage (KV rms) 36 kv (c) Frequency 50 Hz (d) Transformation ratio (CT Ratio) 400-200/1-1-1-1A (e) Rated output (VA burden) core 1-15 VA, Core 2-30 VA (f) Accuracy class -core1-1.0, core2-5P10 (g) Short time current 31.5KA RMS for 3 sec (h) Rated continuous thermal current 120% of rated current (j) Insulation Level- 36/70 KV.170 KVP (k) Max. temp. rise over max. ambient temp. of 50 deg. C at rated continuous thermal current at rated frequency and with rated burden.
Supply, jointing and testing of end termination joint in replacement of outdoor type heat shrinkble type complete with jointing material and accessories suitable for 33 KV(E) XLPE armoured aluminium conductor cable of size 300 to 400 sqmm 3 core complete all as specified and directed.
Supply, jointing and testing of end termination joint in replacement of indoor type heat shrinkble type complete with jointing material and accessories suitable for 33 KV(E) XLPE armoured aluminium conductor cable of size 300 to 400 sqmm 3 core complete all as specified and directed.
Material and labour for route tracing the 11 KV HT cable.
Material and labour for route tracing the 33 KV HT cable.
Material and labour for preparation of old painted surfaces of floor mounted outdoor type power transformer 8 MVA capacity by cleaning/rubbing with course cloth wire brushes to remove dust deposits oil grease and repainting by applying one coat of spray paint with synthetic enamel paint of approved colour without disturbing/damaging the electrical net work system/equipment including making of capacity /rating /incoming outgoing details in capital english alphabet of size all as specified and directed.
Taking down defective unserviceable 33 KV HT bush porcelain insulator and supply and fix new 33 Kv HT bush porcelain insulator for power transformer outdoor 10 MVA all as specified and directed
Opening of HT box of power transformer, disconnecting/Isolating HT Cable connections of power transformer of capacity 10 MVA capacities, checking of transformer pressure release valve, oil condition and charging of transformer and making all necessary connections / assembly & control circuits all as specified and directed.
M&L for boring of holes under road/pavement/hard standing including material and labour for HDPE pipe of 160mm dia suitable for 06 Kg/cm working pressure. Wall thickness of pipe not less than 6.5 mm. Note :-(i) The contractor will be responsible for taking permission from appropriate authority i.e NHAI/IGL, if needed for above said work. (ii) Depth of the trench less shall not less than 2 mtr from ground level otherwise specified due to site requirement and contractor has to maintain the depth of trenchless upto 4 mtrs from ground level if required as per site condition all rates quoted shall be deemed to be included to maintain the trench less depth as directed during excavation to avoid damages to the existing services . (iii) The cost of quoted is deemed to be included for repairs/rectification for damaged done to the existing /communication and water supply system/sewage system during excavation of work.
Supply and fix cable route indicator made of RCC with 8 mm TMT @ 150mmc/c bothways size 0.9 M height x 30 cm wide x 10 cm thick tapered on top visible above ground duly painted with synthetic enamel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33/11 KV will be given by Engr-in-charge complete all as specified and directed.
M/s Birja Nand (BID ID -3382403)
DS CONSTRUCTION (BID ID -3381908)
Rajindera Enterprises (BID ID -3380018)
mayur enterprises (BID ID -3379681)
Vijay Electricals (BID ID -3382499)
MV Engineers And Contractors (BID ID -3378384)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .