Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest and Quoted rates are reasonable | |
| 2 | L2₹31.1 L+₹63,544.50 (2.09%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹31.2 L+₹79,927.10 (2.63%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹31.7 L+₹1.3 L (4.21%)Rejected-Finance 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹31.8 L+₹1.4 L (4.44%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
26 Mar 2024, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD CAMP PULGAON PIN 442303
Repair to PCC Path, drain and fencing in Zone A RA Area at CAD Pulgaon
2024_MES_644986_1
8093/PUL/E8
Open Tender
Civil Works
Item Rate
180 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE PULGAON
₹60,000
Yes
24 Apr 2024
4 Mar 2024
2 Apr 2024
4 Mar 2024
26 Mar 2024
21 Mar 2024
4 Mar 2024 - 20 Mar 2024
Amount
M&L of machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade including 50 mm sand cushioning with grey cement and pigment including demoltion of existing and disposal of rubbish complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling mass concrete and sub base including demolition of cement concrete in ground floors and pavings and disposal of rubbish complete all as specified and as directed.
M&L PCC 1:4:8 type D2 (using 40 mm graded aggregade ) in foundation filling and mass concrete for post holes complete all as specified and as directed.
M&L in repairs for hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection/ path/hardstanding even and smooth without using extra cement including demoltion of existing damaged PCC and disposal of rubbish complete all as specified and as directed.
M&L for 100mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in path/paving/hard standing and finishing the surfaces even and smooth without using extra cement including demoltion of existing damaged PCC and disposal of rubbish complete all as specified and as directed.
M&L for coloured, textured finish/ non skid ceramic tiles of th (8-10 mm), area of each tile n exc 0.36sqm, laid in floors/path/ hardstanding/wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed in CM 1:4 including dismantling of existing floor/wall tiling with cement mortar bedding (but not backing) and removing the rubbish off the premishes complete all as specified and as directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, laid in floors/path/ hardstanding/wall etc set and jointed in neat cement slurry with a mixture of white and grey cement with no pigments and incl 15mm thick screed bed in CM 1:4 including dismantling of existing floor/wall tiling with cement mortar bedding (but not backing) and removing the rubbish off the premishes complete all as specified and as directed.
M&L for granite (of any type) work (table rubbed and polished) of 14-16 mm th as in steps,floor, jambs, pillars, window-cills, cooking platforms and like laid over cement screed of 10mm th in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including demolition of existing stone slab and tiles of any description or th in floors , aprons etc complete all as specified and as directed.
M&L 14-16mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incluing demolition of existing wall tiling of any description and removing the rubbish off the premises complete all as specified and as directed.
M&L for RCC nominal mix type B1 1:2:4 (20mm graded aggregate) as in Columns, Slabs, Soffits, Beams, Chajjas including demolition of existing RCC and removing the rubbish off the premises complete all as specified and as directed.
M&L for Formwork to flat surfaces to sides of concrete for Columns, Slabs, Soffits, Beams, Chajjas with fair finish of concrete complete all as specified and as directed.
M&L mild steel TMT bars 10 mm dia and over cut to length, bend to shape required, incl cranking bending spirally for hooking for column, hooking ends and binding with 0.9 mm dia annealed wire confirming to ISI complete all as specified and as directed.
M&L mild steel 6 to 8mm mm dia TMT bars as in stirrups, spacers and binders, bend to shape required, incl cranking bending spirally for hooking for column, hooking ends and binding with 0.9 mm dia annealed wire confirming to IS complete all as specified and as directed.
M&L for Brick work with fly ash bricks straight or curved on plan exc 6m in radius but built in 1:6 cement mortar including demoltion of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc complete all as specified and as directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1 : 6 including demoltion of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc complete all as specified and as directed.
M&L for Raised pointing to random or polygonal rubble, un coursed or brought upto courses CM 1:4 complete all as specified and as directed.
Taking down cement plaster of any description on brick/ Stone Walls or from Concrete Surfaces incl raking out joints, hacking for key, scrubbing down with water etc all as specified and removing unserviceable material outside premises complete all as specified and as directed.
M&L for 15mm thick rendering in two coats on stone/ brick/ concrete surfaces (external) finished even and smooth without using extra cement etc. 1st coat 10 mm thick in CM 1:6 and 2nd coat 5mm thick in CM 1:4 mix with water proofing compound as per manufacturer instructions complete all as specified and as directed. Note : WPC shall measured and paid Seprately
Supply only Integral water proofing Compound
M&L in repairs for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directe incuding necessary formwork required complete all as specified and as directed.
M&L for preparation of new or old plastered/unplastered surfaces of wall and applying two coats of cement base paint over a coat of white cement primer complete all as specified and as directed.
M&L for preparation of new or old plastered/unplastered surfaces of wall and applying three coats of whitewash complete all as specified and as directed.
M&L for PCC(1:2:4) type B-1 (using 20mm graded stone aggregate) as in surface channel in drains including demolition of cement concrete (un reinforced) of any description and in any position complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
Add or deduct for each 25 mm girth or part thereof over or under 30cm
M&L in repairs Reinforced concrete pipes, 300mm inner dia class NP2, laid and jointed complete with collars complete all as specified and as directed.
Dismantling post or post struts (wood steel or RCC) any section, including taking out embedded portion and making good posts embedded in concrete complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for fencing post complete all as specified and as directed.
M&L for reinforced cement concrete type B-1 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts straining or terminal posts, struts etc for fencing averge sectional area exc 100 and n exc 250 sq cm with or without chamfered angles and flat, splayed rounded or mitered tops and including necessary form work complete all as specified and as directed.
M & L for mild steel angle, flat work and other steel Sections as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or rivetting etc conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M & L for preparing new or previously untreated of steel and applying two coats of synthetic enamel paint over a coat of red oxide over 10 cm in width or girth complete all as specified and as directed.
S&F in repair MS galvanised chain link fencing with exc 3mm dia wire of 75 x 75 mesh size any type standard fixed with angle iron post and MS flat complete all as specified and as directed.
S&F in repair galvanised 2 strand, steel barbed wire 2.2 mm dia barbed wire with 2 mm dia barbs at 75 mm spacing and straining and fixing as directed by EIC.
S&F Mild steel screw bolts (machine made) 11 mm to 15 mm dia exceeing 5cm & n exc 10cm long with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and as directed.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.complete all as specified.
M&L for precast cement concrete jallies in PCC (1:2:4) type B0 (12.5 graded agg), 35 mm thick (measured solid) set in CM 1:6 including all moulding etccomplete all as specified and as directed.
M&L for preparing new or previously untreated surfaces, of steel and iron work of any description not otherwise described not exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
SHREE SIDDHIVINAYAK TRADERS
I P Constructions
MAHARASHTRA ENTERPRISES
M/S L M Chourasia
M/s VILAS RATAN MENDHE
M/s Dara Constructions, Pulgaon
SHRI RANI SATI TRADERS
NEELKAMAL BUILDERS
M/S Ramakant Chourasia
Bidder Name
M/S L M Chourasia
SHRI RANI SATI TRADERS
SHREE CONSTRUCTIONS
SHREE SIDDHIVINAYAK TRADERS
M/s VILAS RATAN MENDHE
M/S Ramakant Chourasia
MAHARASHTRA ENTERPRISES
M/s Dara Constructions, Pulgaon
NEELKAMAL BUILDERS
I P Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .