Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.9 L+₹56,150 (5.98%)Rejected-AOC 7 2 S F ARIHANT ARCADE CENTRAL MARKET SHASTRI NAGAR MEERUT U P 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L2 | Rejected-AOC L2 | |
| 3 | L3₹10.0 L+₹59,771.80 (6.37%)Rejected-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L3 | Rejected-AOC L3 | |
| 4 | L4₹10.1 L+₹67,990 (7.25%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹11.0 L+₹1.6 L (17.1%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹25.0 L
EMD Value
₹49,940
Closing Date
1 Jul 2021, 6:00 pmClosed
GE(U) E/M Meerut Cantt
GE(U) E/M Meerut Cantt
TENDER FOR ITEM RATE CONTRACT FOR REWIRING TO INTERNAL ELECTRIFICATION AT MH MEERUT UNDER AGE E/M (ES) AT GE (U) E/M MEERUT CANTT.
2021_MES_447375_1
8341/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE(U) E/M Meerut Cantt
₹49,940
Yes
28 Aug 2021
2 Jun 2021
10 Jul 2021
2 Jun 2021
1 Jul 2021
17 Jun 2021
2 Jun 2021 - 10 Jun 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items will be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. to match with the adjoining surafces complete all as specified .
M&L point wiring for one light point/fan point/bell point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables in and including 25 mm dia or higher size PVC , medium grade concealed conduits and fittings, including 3mm thick plastic laminated sheet top cover plate with frame and pressed steel terminal switch boxes and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit & sunkin boxes and cover plate & frame etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one 3 Pin socket outlet on independent Board controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables in and including 25 mm dia or higher size medium grade , PVC concealed conduits and fittings, including 3mmthick plastic laminated sheet cover plate with frame and pressed steel terminal switch boxes and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit & sunkin boxes and modular cover plate & frame etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one 3 Pin socket outlet on same board with other swiches controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables including suitable size cover plate with frame and pressed steel terminal switch boxes and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit & sunkin boxes and modular cover plate & frame etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one light point/fan point/bell point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables in existing surface/concealed conduit of any dia, including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) and connecting to earth dolly and brass screws, washers etc. complete all as specified :-
M&L point wiring for one 3 Pin socket outlet on independent Board controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables in existing surface/concealed conduit of any dia including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) and connecting to earth dolly and brass screws, washers etc. complete all as specified :-
M&L point wiring for one 3 Pin socket outlet on same board with other swiches controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables in existing surface/concealed conduit of any dia including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) and connecting to earth dolly and brass screws, washers etc. complete all as specified :-
M&L point wiring for one 3 Pin socket outlet 16 Amps on independent Board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables in and including 20 mm dia or higher size medium grade ,PVC concealed conduits and fittings, including suitable size modular cover plate with frame and pressed steel terminal switch boxes and including continuous earth wire of 2.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit & sunkin boxes and modular cover plate & frame etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one 3 Pin socket outlet 16 Amps on independent Board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables in existing surface/concealed conduit of any dia including continuous earth wire of 2.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) and connecting to earth dolly and brass screws, washers etc. complete all as specified :-
Supply & fixing polycarbonate Switch piano flush type,SP, 6 Amps, one way complete all as specified.
S&F polycarbonate bell push flush type,SP, 6 Amps, one way ( ISI) marked complete all as specified.
S&F Buzzer, Ding dong, AC 230 Volts, single pole complete all as specified and directed.
S&F Polycarbonate Switch piano flush type , single pole, 16 Amp, one way (ISI) marked complete all as specified.
S&F socket out let 3 pin , 6 Amps (2 in 1 Multi purpose) flush type controlled by one switch ISI marked make complete all as specified.
S&F socket out let 2 in 1 , 3 pin , 15 Amps flush type controlled by one switch ISI marked complete all as specified.
S& F electronic ceiling fan regulator, rotary 0 to 04 steps, hum free, 100 watt complete all as specified and directed Two module complete all as specified.
S&F Lamp holder, polycarbonate type (Angular/Straight) complete all as specified and directed.
S&F polycarbonate insulated body ceiling rose 6A, 65x50mm with three terminals, ISI maked fixed complete all as specified.
S&F in repair Light emitting Diode (LED) tube light fitting surface type, indoor decorative aluminium extruded T5 LED battens , Integrated type, box type AC 220-240V, 50 hz, with acrylic diffuser 20 watt, 4' long, and making connections with and including 23/.0076 copper conductor flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S&F in repair Light emitting Diode (LED) tube light fitting surface type, indoor decorative aluminium extruded T5 LED battens , Integrated type, box type AC 220-240V, 50 hz, with acrylic diffuser 10 watt, 4' long, and making connections with and including 23/.0076 copper conductor flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S&F in repair Light emitting Diode (LED) panel recess mounting 2'x2' - 36 watts, 6000K, diffuser type optics, light fitting with separate electronic driver complete including cutting holes of required size in false ceiling and making good disturbed surfaces complete all as specified.
Taking down existing unserviceable submain wiring with PVC conduit and fittings and S&F submain wiring comprising two single core ,4 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 4 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire including cutting and chasing in wall and making good disturbed surfaces to match with the existing complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x4 sqmm wire and 1x4 sqmm earth wire shall be measured as one unit length)
Taking down existing unserviceable submain wiring with PVC conduit and fittings and S&F submain wiring comprising two single core ,6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire including cutting and chasing in wall and making good disturbed surfaces to match with the existing complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x6 sqmm wire and 1x6 sqmm earth wire shall be measured as one unit length)
Taking down existing unserviceable submain wiring with PVC conduit and fittings and S&F submain wiring comprising two single core ,10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire including cutting and chasing in wall and making good disturbed surfaces to match with the existing complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x10 sqmm wire and 1x10 sqmm earth wire shall be measured as one unit length)
S & F in repair MCB SP, 6 to 32 Amps, 240 Volts , 10 KA, 'C' curve rating (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
S&F in repair MCB SPN , AC, 40 amps, 240 Volts , 10KA 'C' series complete all as specified.
S&F in repair MCB SPN , AC, 63 amps, 240 Volts , 10KA 'C' series complete all as specified.
S&F in repair MCB TPN , AC, 100 amps, 415 Volts , 10KA 'C' series complete all as specified.
Taking down of existing unserviiceable Sheet metal enclosures (DB) complete and removing and S&F epoxy powder coated distribution box, SPN, 08 ways, 200 Amp capacity, 240 volts, IP-43 ,metal double door for MCB , grouted flush to walls including making good disturbed surafces of wall to match the adjoining surfaces complete all as specified and directed.
Taking down of existing unserviiceable Sheet metal enclosures (DB) complete and removing and S&F epoxy powder coated distribution box, SPN, 4 ways,200 Amp, 240 Volts IP-43 ,metal double door for MCB, grouted flush to walls including making good disturbed surafces of wall to match the adjoining surfaces complete all as specified and directed.
Taking down of existing unserviiceable Sheet metal enclosures (DB) complete and removing and S&F epoxy powder coated distribution box, SPN, 12 ways, 200 Amp, 240 volts, IP-43 ,metal double door for MCB , grouted flush to walls including making good disturbed surafces of wall to match the adjoining surfaces complete all as specified and directed.
Taking down of existing unserviiceable Sheet metal enclosures (DB) complete and removing and S&F epoxy powder coated distribution box, TPN, 4 ways, 415 volts, IP-43 ,metal double door for MCB/isolators , grouted flush to walls including making good disturbed surafces of wall to match the adjoining surfaces complete all as specified and directed.
S&F in repair SPN Sheet metal enlosures (factory made) with 10KA, 'B' curve Single pole MCB rated 20 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making connection complete all as specified.
S&F in repair Light emitting diaode (LED) bulb 12 watts, retrofit type, 240 volts complete all as specified and directed
Supply and fix driver suitable fpr 36 Watt LED Ceiling light fittings (140-270volt) as per existing fitting all as specified and directed.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level connected to GI earth lead wire 4 mm dia by means of nuts and bolts, check nuts and washers of galvanised iron or steel, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, GI wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 40mm thick precast RCC 1:2:4 type B-1, duly reinforced with 8mm dia TMT bars @ 150mm C/c and 6mm dia bars in lifting handles amd MS angle frame of angle iron 40x40x5 mm thick, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supplying, fixing including connecting and testing of energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium with toughened glass cover housing, 30 watts LED to achieve electrical safety class 1, CRI>70 colour temperature 5000k to 6000k with LED working life time >50000 burning hours with integrated constant current electronic driver, nominal volatge 240V, AC,50 Hz, operating voltage range 120-280V, suitable for ambient environmental condition of station, TDH<10%,, Pf >0.95, lumens >80 lm/W, Ingress protection not less than IP65, driver and luminaire shall comply not less than LM-79 or IS 16106 of 2012 including 32mm nominal bore light grade GI pipe brackets made out of 1.50M long GI pipe ,bent to shape and fixed to poles/ walls with Two Nos mild steel flat iron brackets of 40mmx6mm, comprisng 4 Nos mild steel hexogonal head bolts of 12 mm dia, 75 mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connections with cable complete all as specified and directed
AEGIS INTERNATIONAL
Jain Traders
SIDDHARTH TRADERS
R P G ELECTRONIC REGD
M/S JPS Electrical Engineer & Contractor
NITHYA INFRATECH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .