| Sl No | Description | Qty | Unit | Prakash Trading Corporation L1 | VEE ESS ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00 | Routine checking of complete central AC plant of 3 x 12 TR capacity as required during the contract period, fault detection by OEM/authorised partner of OEM with whom MOU stands signed for smooth functioning of the plant as well as for uninterrupted running all as required at site, complete all as specified and as directed | 10 | Each Job | 4,500 ₹45,000 | 4,000 ₹40,000 Lowest |
| 2.00 | Supply and topping of chiller/ compressor unit (12TR AC Plant) with R-407C refrigerant including leak testing and necessary associated repair works, complete all as specified and as directed | 460 | Per KG | 300 ₹1,38,000 Lowest | 500 ₹2,30,000 |
| 3.00 | Supply, installation, testing and commissioning of microprocessor controllers with scanners/ under voltage/ over voltage protections for chillers including caliberation/ settings as per the requirement of the system of chiller controller for proper safeties like under voltage, overvoltage, low pressure and high pressure complete including taking down old unserviceable controllers, complete all as specified and as directed | 3 | Each Job | 4,200 ₹12,600 Lowest | 5,000 ₹15,000 |
| 4.00 | Pressure transducers for suction pressure of compressors including taking down old unserviceable and testing, complete all as specified and as directed | 3 | Each Job | 900 ₹2,700 Lowest | 5,000 ₹15,000 |
| 5.00 | Pressure transducers for discharge pressure of compressors including taking down old unserviceable and testing, complete all as specified and as directed | 3 | Each Job | 900 ₹2,700 Lowest | 5,000 ₹15,000 |
| 6.00 | Complete overhauling of Delta cooling tower by chemical cleaning of sump, dismantling and servicing of cooling tower strainer, dismantling of cooling tower motor and fan and sprinkaler assembly, descaling of sprinkler pipes and adjustment of sprinkler speed and refitting of motor and fan assembly after satisfactory operation including descaler and replacement of PVC honeycomb fills, complete all as specified and as directed | 2 | Each Job | 16,000 ₹32,000 | 10,000 ₹20,000 Lowest |
| 7.00 | Repair & servicing of existing pump starters in the LT control panels of any rating/ type and any capacity, Replacing unserviceable components such as meters, cable lugs, Push buttons and CT coils etc including necessary wiring for DOL and Star- Delta starters using FRLS copper conductor of size not less than 1.5 Sqmm and necessary feruls and casing capping required to secure the wiring complete all as directed testing and commisioning to the entire satisfaction of the complete all as specified and as directed | 4 | Each | 3,900 ₹15,600 | 2,000 ₹8,000 Lowest |
| 8.00 | Servicing of condensor water pumps including replacement of impellors and seals, complete all as specified and as directed | 3 | Each Job | 2,200 ₹6,600 | 1,000 ₹3,000 Lowest |
| 9.00 | Servicing of chilled water circulations pumps including replacement of impellors and seals, complete all as specified and as directed | 3 | Each Job | 4,500 ₹13,500 | 1,000 ₹3,000 Lowest |
| 10.00 | Servicing of AHU cooling coil including chemical cleaning with OEM recommended chemical 'scalefoe', complete all as specified and as directed | 2 | Each Job | 4,500 ₹9,000 | 1,000 ₹2,000 Lowest |
Tender Value
₹20.0 L
EMD Value
₹40,000
Closing Date
21 Nov 2025, 6:00 pmClosed
Col Amit Bhardwaj
HQ, CWE Jammu PIN-900172
REPAIR TO AC PLANT AT BIRPUR UNDER GE KALUCHAK
2025_MES_737886_1
CWE/JP-56/2025-26
Open Tender
Civil Works
Works
180 days
GE Kaluchak
As per tender documents
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹40,000
Yes
16 Jan 2026
31 Oct 2025
24 Nov 2025
31 Oct 2025
21 Nov 2025
14 Nov 2025
31 Oct 2025 - 4 Nov 2025
Amount
Routine checking of complete central AC plant of 3 x 12 TR capacity as required during the contract period, fault detection by OEM/authorised partner of OEM with whom MOU stands signed for smooth functioning of the plant as well as for uninterrupted running all as required at site, complete all as specified and as directed
Supply and topping of chiller/ compressor unit (12TR AC Plant) with R-407C refrigerant including leak testing and necessary associated repair works, complete all as specified and as directed
Supply, installation, testing and commissioning of microprocessor controllers with scanners/ under voltage/ over voltage protections for chillers including caliberation/ settings as per the requirement of the system of chiller controller for proper safeties like under voltage, overvoltage, low pressure and high pressure complete including taking down old unserviceable controllers, complete all as specified and as directed
Pressure transducers for suction pressure of compressors including taking down old unserviceable and testing, complete all as specified and as directed
Pressure transducers for discharge pressure of compressors including taking down old unserviceable and testing, complete all as specified and as directed
Complete overhauling of Delta cooling tower by chemical cleaning of sump, dismantling and servicing of cooling tower strainer, dismantling of cooling tower motor and fan and sprinkaler assembly, descaling of sprinkler pipes and adjustment of sprinkler speed and refitting of motor and fan assembly after satisfactory operation including descaler and replacement of PVC honeycomb fills, complete all as specified and as directed
Repair & servicing of existing pump starters in the LT control panels of any rating/ type and any capacity, Replacing unserviceable components such as meters, cable lugs, Push buttons and CT coils etc including necessary wiring for DOL and Star- Delta starters using FRLS copper conductor of size not less than 1.5 Sqmm and necessary feruls and casing capping required to secure the wiring complete all as directed testing and commisioning to the entire satisfaction of the complete all as specified and as directed
Servicing of condensor water pumps including replacement of impellors and seals, complete all as specified and as directed
Servicing of chilled water circulations pumps including replacement of impellors and seals, complete all as specified and as directed
Servicing of AHU cooling coil including chemical cleaning with OEM recommended chemical 'scalefoe', complete all as specified and as directed
Disconnecting the electric connections of the electric motor 2 HP of the cooling tower blower, taking out the old unserviceable winding wire, cleaning the slots for rewinding, rewinding the electric motor 3 Phase, 415 volts with existing size of super enamelled copper winding wire including allied materials like cotton tapes, glass sleeves, varnishing and assembling the complete motor and testing, complete all as specified and as directed.
Descaling of condensors with 'scalefoe' 100 chemical by pressure pump, opening of condensor head and rodding with nylon brushes including fixing new gasket, condensors covers and refitting with covers, complete all as specified and as directed
V-Belt as per existing for AHU including taking down old unserviceable V-Belt, complete all as specified and as directed
Start push button assembly, complete all as specified and as directed
Stop push button assembly, complete all as specified and as directed
Water pressure gauge 100mm range ( 0 to 75psi) including taking down old unserviceable gauge, complete all as specified and as directed
Temperature gauge stem type including taking down old unserviceable gauge, complete all as specified and as directed
Electronic Star-Delta Timer type ST100 160 - 500V, for 3 - 30 sec Model No : ST80328OOOO Make :Schneider/ Siemens/ L&T/ Legrand/ ABB complete all as specified and as directed
Contactor, triple pole, 440 volts Model No MNX 110 including taking down old unserviceable contactor, complete all as specified and as directed
Prefilters (10 microns) in the AHU complete including taking down old unserviceable prefilters, complete all as specified and as directed
Y- strainer for chilled water and condensor water lines complete including taking down old unserviceable Y strainer, complete all as specified and as directed
AHU controls suitable for 12 TR water cooled air conditioning system complete including taking down old unserviceable AHU controls, complete all as specified and as directed
Filter drier 1/2" to 5/8" suitable for 12 TR Air conditioning plant including taking down old unserviceable filter, complete all as specified & directed. Make: Emerson/ Danfoss/ Catchall/ as per OEM
Non return valve 50 mm for pump, conforming to relevant IS with jointing materials including taking down old unserviceable valve, complete all as specified and as directed
Dismantaling and taking down existing duct of any size and type with insulation of any types complete all as specified and as directed
Supply , assembly and erection of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc of size 18 Gauge. complete all as specified and as directed Note:-The duct shall be fabricated in factory as per IS655-2006 and to be assembeled at the site, No fabriction at site will be permitted . Contractor must visit the site before quoting of the rates .The whole ducting shall be tested for any leakage and vibration after completion of job all as specified and directed.
S & F Framed brackets of angles or tees with web and flanges for duct supports cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 with taking down old u/s MS Channel support of AC duct complete all as specified and as directed
Supply and fixing for thermal insulation of supply/return air duct with cross linked closed cell performed sections of polyethylene (FR) insulation of 25 mm laminated with Aluminium Metalised polyester foil having a low stable k value of 1.6 with minimum density of 28 kg/cum duly pasted on duct with good quality adhesive and nitrile tape, isulation over duct shall be provided in such a way that it should cover the duct from all the sides including supports complete all as specified and as directed
M&L for Taking down and refixing existing grill of any size and any type complete all as specified and as directed
Dismantling and taking down unserviceable UG cable of any size complete all as specified and as directed
MCB, triple pole, 63 Amps, AC, 415v, 50Hz, breaking capacity 10 KA, C-curve including taking down old unserviceable MCB, complete all as specified and as directed
MCB, triple pole, 40 Amps, AC, 415v, 50Hz, breaking capacity 10 complete all as specified and as directed
MCCB of capacity 125 Amps, 3 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, AC, 50 C/S, including taking down old unserviceable MCCB, complete all as specified and as directed
MCCB of capacity 160 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S, including taking down old unserviceable MCCB, complete all as specified and as directed
Voltmeter (0-500V) digital flush type 96mm, square type including taking down old unserviceable voltmeter, complete all as specified and as directed
Ammeter (0-100A) digital flush type 96mm square type complete all as specified and as directed
Over load relay with range (12- 18) Amps including taking down old unserviceable relay, complete all as specified and as directed
Over load relay with range (07- 10) Amps including taking down old unserviceable relay, complete all as specified and as directed
Indoor Thermometer Digital Thermo-Hygrometer Temperature and Humidity Meter Room Climate Indicator with Calibration Touchable Night Light, Comfort Display MAX/MIN Data Sets, complete all as specified and as directed
On load change over switch in sheet metal enclosure, 200 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all as specified and as directed
MCCB of capacity 250 Amps, 4 pole, 415volt, 50Hz, breaking capacity 36 KA (minimum) or higher, adjustable thermal and fixed magnetic release, complete as per OEM standard design including taking down old unserviceable MCCB, complete all as specified and as directed
MCCB of capacity 200 Amps, 4 pole, 415volt, 50Hz, breaking capacity 36 KA (minimum) or higher, adjustable thermal and fixed magnetic release, complete as per OEM standard design including taking down old unserviceable MCCB, complete all as specified and as directed
Supply and fix of Impulse Emergency First aid kit box with basic medicine like Band Aid strips of min 20 Nos, Antiseptic cream, Cotton, Surgical tape 1 inch, non sterial gauge swabs, Hydrogen peroxide bottle, medical spirit bottle complete all as specified and as directed
Supply and fix of Cooling Tower Sprinkler Fan Apply for Round Type Counter Flow in Cooling Tower for smooth functioning of the plant as well as for uninterrupted running all as required at site, complete all as specified and as directed
Material and labour strip opening of compressor model screw type of Suitable Make , 12 TR capacity cheking of serviceability of parts, keeping a side for refixing , replacing the unsv worn out parts for top overhauling the compressor and remove the insulation of the coil/all spare parts including washer, nut & bolts cleaning, drying varnishing baking and refixing all as per the existing portion coil insulation binding properly after drying refixing in the same portion complete incl grinding, polishing and after minor repairs /replacement of minor parts with necessary split pins, recondition of suction and discharge valve replacing rubber sealing etc all as specified and directed by Engineer-in-charge Note for item No. (I) Replacement parts, Refrigerant gas and compressor oil for topping up will be measured and paid seperately, (ii) Labour element is included in unit rate (iii) Unit rate also includes evacuating gas and oil from the system and recharging on completion. Supply only following spares for the Compressor screw type Make The part shall be as per existing compressor make.
Main bearing non end driving for compressor complete all as specified and as directed
Main bearing driving end for compressor complete all as specified and as directed
Connecting rods complete all as specified and as directed
Discharge reed with springs (sets) complete all as specified and as directed
Suction reed with springs (sets) complete all as specified and as directed
Piston ring (sets) complete all as specified and as directed
Cylinder liner complete all as specified and as directed
Piston any size complete all as specified and as directed
Gasket set complete all as specified and as directed
Gudgen pin with bush. complete all as specified and as directed
Crank shaft complete all as specified and as directed
Internal Oil filter complete all as specified and as directed
External Oil filter complete all as specified and as directed
Oil pressur switch complete all as specified and as directed
Fuse as per existing complete all as specified and as directed
Compressor contactor complete all as specified and as directed
Compressor Oil complete all as specified and as directed
Filter drier complete all as specified and as directed
XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured electric cables (heavy duty) of size 120 Sqmm, 3.5 core with aluminium conductor (multistranded) 1100 volts grade (earthed) connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion and removal of old unserviceable cable, complete all as specified and as directed
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc, complete all as specified and as directed Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and as directed
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and as directed Note:- Punned thickness of sand will be measured and paid.
Supplying and laying reinforced precast, Class LV, Type I, flat, size 250mm x 150mm x 40mm concrete cable cover, complete all as specified and as directed
Galvanised iron tube 80mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified and as directed
M&L for Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 90 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and as directed
M&L for painting the exterior parts of cooling towers with epoxy seal paint as per the manufactures specifications including preparing the surfaces of cooling towers after removing all the PVC fill , nozzles, ID fan and cleaning the water collecting tray for algae free surfaces using necessary detergent chemicals complete sealing the leakage on the body if any while apply the epoxy sealing paint complete all as specified and as directed
Leak testing of the AC plant with nitrogen (N2) pressure after evacuating of the existing gas from the system into empty cylinder by separating the entire system, like compressors, evaporator, condensers, cooling coil and refrigerant lines and rectifying the leakage including cutting welding brazing etc and replacing of 'O' ring, washers, gaskets etc flushing out the Nitrogen and vaccumising, recharging the taken out refrigerant gas including testing complete all as directed to AC plants of capacity 3x12 TR AC plant complete all as specified and as directed
Supply & fix Scale guard of suitable size of existing Central AC following plants of 3x12TR capacity water cooled pipe line removing existing scale guard carefully without any damaging of pipe line and fix new scale guard testing complete all as specified and as directed
Supply and laying electrical rubber matt confirming IEC 61111 ISI marked of grade, 6 mm thick, 1.0 mtr width, blue/black coloured anti skid taxture finish ROHS/PAH complete including fixing on ground using necessary chemical adhesive liquid complete all as specified and as directed
M & L in repair for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dia and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil not less than 50 mtr from the earthing place all as specified and directed and tested on completion. including testingall complete all as specified and as directed
VEE ESS ENGINEERS (BID ID -3478047)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
tender56_merged.pdf
Tender Documents • 1.69 MB
BOQ_826232.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .