Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC Quoted rates lowest | |
| 2 | L2₹32.9 L+₹2.0 L (6.38%)Rejected-Finance | L2 | Rejected-Finance Quoted rates not lowest | |
| 3 | L3₹37.3 L+₹6.5 L (20.9%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Quoted rates not lowest |
Tender Value
Refer Docs
EMD Value
₹75,360
Closing Date
11 Mar 2021, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT-10
PROVN OF MT STORE TWO WHEELER STAND FOR PARKING OF 20 X TWO WHEELERS AT PT GROUND AND SPL REPAIR TO BLDG NO P 34 AT ENTITY B 61 WEU ARMY CAMP HIRANKUDNA UNDER GE NORTH DELHI CANTT 10
2021_MES_409383_3
CWE/D-55/2020-21
Open Tender
Civil Works
Item Rate
120 days
Delhi Cantt
AS PER NIT
7 documents required · 7 mandatory
₹500
GE NORTH DELHI CANTT
₹75,360
Yes
7 May 2021
25 Feb 2021
12 Mar 2021
25 Feb 2021
11 Mar 2021
27 Feb 2021
Amount
Demolition of reinforced cement concrete of any description and in any position all as directed and specified.
Seprating, scraping and cleaning of reinforcement, all as directed and specified.
M & L for Design Mix M-25 in lintals, beams exc 1.50 mtrs clear span , columns landings, balconies,canopies,chajja, deck slabs , shelves and the like ,complete all as specified and directed.
M&L mild steel TMT bars 10 mm dia cut to length bent to shape required incl cranking,bending, spirally, hooking and binding with and incl MS wire 0.9 mm dia complete all as specified and directed.
All as per srl Item No-4 but 5mm dia and over as in stirrups, space and binder, all as directed and specified.
M & L for rough finish surface form work to side and soffits of floor,roof beamand simmilar works all as directed and specified.
M & L for Providing,Plain cement concrete 1:2:4 Type B-0(12.5 mm graded stone aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rouinded for chamfered angles and throating, including formwork all as directed and specified.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and directed.
M&L non skid coloured ceramic tiles, 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry, pointed in coloured cement to match the colour of tiles over and including screed bed 15mm thick in cement mortar 1:6 all as directed and specified
M&L for glazed ceramic coloured tiles of size 450x350x7mm thick vertical surface such as dado, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including layer 10mm thick in cement mortar 1:4 complete all as directed and specified
M&L for grinding and mirror polishing of machine cut kota stone slab flooring including filling in neat grey cement slurry mixed with pigment to match the shade of the slab where as required etc complete as directed and specified.
Dismantling Stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc.complete as directed and specified.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick cement morter (1:6) screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc complete all as directed and specified.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 all as directed and specified.
All as per Item No. 15 above but except bricks complete all as directed and specified.
M & L for Removing mortar from bricks built in cement mortar and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish complete all as directed and specified.
M&L for Brick work with subclass‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 all as directed and specified.
Taking down chowkhats or frames with shutters(without taking off shutters from the frames) not exceeding 1.5 sqm and remove from site as directed and specified.
All as per item No 19 here-in-before but exceeding 1.5. sqm but n.exc 4 sqm each and -ditto- complete as directed and specified.
Refixing in same opening chowkhats or frames with shutters(without taking off shutters from the frames) not exceeding 1.5 sqm as directed and specified.
Ditto but exceeding 1.5. sqm but n.exc 4 sqm each complete as directed and specified.
M&L mild steel angle iron Fe-290 (Gde E-165) and other section in door chowkats and frames all as specified and directed.
Supply and fix for 35 mm thick 2nd class hard wood plain, framed, panelled door shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats.
Supply and fix 35mm thick, 2nd class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc with rails and styles including cut and mitered beards for securing wire cloth etc, the size of members as specified in SSR , Part I section 8, clause No 8.24 (a) and as directed
S&F box type mild steel windows glazed / gauzed incl frame made of hollow sections 60 x 25 x 1.25 mm thick 50 x 20 mm x 1.25 mm thick MS Hallow pipes as in windows shutter with sash bars incl 150 mm size MS tower bolts 2 No each leaf, MS handle made of Z section 100 mm long 2 Nos each leaf, mild steel cleat 55 mm x 25 mm x 75 mm long 2 Nos each leaf, MS Pintel hing 75 mm long 14 mm dia 02 Ns each leaf complete all as specified and directed of make : M/s Tee Pee Industries, Amritsar, M/s Metal Window Corp New delhi/ M/s Chandini Industries, Ghaziabad.
S&F mild steel work of any section as in framed window guard bars/grills as directed and specified
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc 0.5 Sqm in each pane as directed and specified
Supply and fix Galvanised mild steel wire cloth of 0.56 mm nominal dia of wire, average width of apparature 1.18mm & fixed with tinned tacks or galvanised wire staples as directed and specified.
Supply and fix in repair Galvanised mild steel wire cloth of 0.56 mm nominal dia of wire, average width of apparature 1.18mm & fixed with tinned tacks or galvanised wire staples as directed and specified.
S & F 300mm long Mild steel sliding door bolts plate type, store enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed.
Supply and fix Mild steel medium weigh butt hinges 100mm size and fixed as directed and specified.
S & F Aluminium anodisedl barrel tower bolts of extruded section and fixed length of bolt 150 mm all as specified and directed .
S & Faluminium handle cast type , size of handle 150mm all as specified and directed
S & F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, as specified all as specified and directed .
S&F Factory made solid panel PVC door shutter 30 mm thick ( style ) consisting of frame made out of mild steel tubes for top and bottom rails . Mild steel frame shall be covered with heat moulded plain cover PVC 'C' channel having a PVC sheet strip of 20 mm complete all as specified and directed
Demolition of cement concrete of any description and in any position(unreinforced) in ground floors below or above ground level n.exc 15 cm thick all as directed and specified.
Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate, 75mm thick as in plinth protection/pavment and the like, finish the surfaces even and fair without using extra cement. It should be laid in alternate bays, each bay n.exc 3m length with joint to be filled with bituminous mastic filling comprising a mixture of Part of heated hot blown bitumen 85/25 penetration and two parts of heated sand all as specifed and directed.
Taking down 15mm bore steel tubing and connections including cleaning for re-fixing or removal to store all as specified and directed .
All as per item No39 here-in-before but 20mm bore and -ditto- complete all as specified and directed
Supply and fix galvanised steel water tubes medium grade 15mm dia with fittings, fixed to walls ceilings and laid in floor etc complete all as directed and specified.
All as per item No 41 here-in-before but 20mm bore and -ditto-complete
Refixing 15mm dia old tubing and connection in new of old position (wall, ceiling floor etc) including making good dismantled cortion as per existing finish or surfaces complete as directed and specified. .
All as per item No.43 here-in-before but 20mm bore complete all as specified and directed.
Supply & Fix rotational moulded polythene water storage tanks, 500 Ltr capacity, white colour tripple layer cylindrical, vertical with closed top, hoisted and fixed in position including dismantling existing water tanks all directed and specified.
S & F 15mm bore PTMT high pressure rate float valve with aluminium rod and ball complete as directed and specified.
S & F in repair vitreous china squatting pan ‘ORISSA’ pattern of size 580mm x 440mm, white with integral foot rest including ‘P’ or ‘S’ trap and concrete bedding etc complete all as directed and specified.
S & F in repair PVC valvesless, syphoni action type, finishing cistern 10 Ltrs capacity, low level, white, with inlet, ball valve float and handle including brackets.
S & F in repair bib taps cast copper alloy C.P 15mm bore with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed all as directed and specified.
S & F in repair concealed stop valve cast copper alloy C.P 15mm bore screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union all as directed and specified.
M & L for in repair 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as directed and specified
ditto as Item No.51 but 20mm dia all as directed and specified
Supply and fix PVC connections 15mm bore with PTMT nuts with washers of length 600 mm all as directed and specified.
Supply & Fix grating square/round 150mm size of PTMT all as directed and specified
M&L Taking down cement plaster of any description from brick, stone walls or concrete surfaces including raking out joints, hacking for key,scrubbing down with water , rendering 10mm thick in cement mortar 1:6,mixed with PD proof 101 LW(+) of Dr fixit or equvalant integral WP admixer @200 ml/bag of cement over two coats of super latex 302 of Dr fixit or equ. in the ratio 1:4: 7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 Kg of homogenious mixture per Sqm in two coats and finished the surface even and fair without using extra cement complete all as specified and directed. Note- PD proof 101 LW(+) and super latex 302 shell be measured and paid seperatly
M&L Taking down cement plaster of any description from brick, stone walls or concrete surfaces including raking out joints, hacking for key,scrubbing down with water,and rendering 15 mm th in cm (1:4) in two layers (10mm+5mm ) mixed with PD proof 101 LW(+) of Dr fixit or equvalant integral WP admixer @200 ml/bag of cement over two coats of super latex 302 of Dr fixit or equ. in the ratio 1:4: 7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 Kg of homogenious mixture per Sqm in two coats and finished the surface even and fair without using extra cement complete all as specified and directed. Note- PD proof 101 LW(+) and super latex 302 shell be measured and paid seperatly
Supply only PD proof 101 LW (+) of Dr Fixit or equivalent
Supply only super latex 302 of Dr fixit or equivalent
M&L for preparation of new plastered surfaces any description and apply two coats of oil bound distemper over a coat of primer on plastered surface area all as specified and directed. .
M&L for preparation of new plastered surfaces any description and apply two coats of cement base paint over a coat of alkali resistant primer on plastered surface area all as specified and directed. .
Preparing plastered or unplastered old decorated surfaces of walls complete removal of exiting treatment and applying two coats of oil bound distemper all as specified .
Preparing plastered or unplastered old decorated surfaces of walls complete removal of exiting treatment and applying two coats of cement based paint all as specified .
Material and labour preparation of new wooden surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer all as directed and specified.
Material and labour preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed and specified..
Material and labour preparation of old/previously treated wooden surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint all as directed and specified.
Material and labour preparation of old/previously treated steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint complete all as directed and specified.
M&L Providing precast cement concrete louvres and jallies, 40mm thick type B-0(1:2:4)(measured solid), including all mouldings set in cement mortar 1:4 complete all as specified and directed.
Impregating cream for injection into masonary or concrete wall against capilary rising humidity. Rising bar supper strong (product No-201) of chowgale building chemicals or equivalent Pidilite/Dr Fixit /Sika / Phosrock /Asian complete all as spd and directed. METHODOLOGY 1. The surface must be sound , absorbent,clean free from dust oil paint etc 2. The plaster must be knocked out at least 50 Cm beyound the visibily penitrated area. 3. Damaged morter,joints are to be scraped out to adepth of appx. 2-3 Cm. Loose morter/ ,concrete to be removed. 4. Drilling bore hole 8-10 mm dia upto 50-60 Cm deep starting from ground level at an angle of min 30 degree into the wall/masonary . Vertical ofset will be min 300 mm. 5. Injucting of cream will be carried out with heigh pressur injucting machin @ 100-150 ML/Miter /hole in single injuction .For uniform filling injuction nazzel will be pulled out . 6. Injuction prosses will be repeted after 24 Hours for propper filling of cream.
M&L for MS work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) ,round or square pipes ms plate , purpose made bolt etc including distance pieces etc.all as specified and direcred.
Dismantling asbestos cement (corrugated, semicorrugated etc) sheet in roof coverings including ridges,valley gutters etc complete all as directed and specified.
S&F Pre- painted plane galvalume aluminum zinc coating GI based steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed.
S&F Pre- painted corugated galvalume aluminum zinc coating GI based steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed.
M & L 4 mm thick size non asbestos fibre cement building boards fixed or laid / inserted to timber/ GI / Aluminiumframe work with screws complete all as per manufacturers instructions and as directed.
S&F GI powder coated frame work of size 605 x 605 mm, for seamless celing comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed.
Surface excavation n exc 30cm deep and averaging 15cm deep & getting out in Soft/loose soil complete all as specified and as directed
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 in depth and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting ouut, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Returing, filling in incl spreading levelling watering and well ramming in layers not exc 25cm complete all as specified and as directed.
Removing excavatged material(Soil) n. exc. 50m and deposting where directed at a level n.exc. 1.5m above the standing point complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
100mm thick broken stone hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering as required all as specified and directed.
M & L for machine pressed precast concrete interlocking payer block any shape and size confirming to IS -15658-2006 of 60 mm thickness (M-35 Grade) with grey cement and no pigment all as specified and directed.
M&L cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in coping incl necessary form work and finishing of exposed surface all as directed and specified.
M&L for damp proof course 40mm thick using PCC 1:2:4 type( B-O) using 12.5mm graded stone aggregate over applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cum. per sqm complete all as specified.
M&Lfor preparing of plastered or unplastered new surface of walls by applying three coats of white wash complete all as specified and as directed
M&L steel work of tubular pipes (medium weight) includingh embeding in concrete and screwing etc. posts and struts in fencing including cutting tops to shape as directed, drilling holes, motching for wire etc. flat iron fillets including all necessary drilling olting or riveting etc. and similar work conforming to Fe-290 Gde E-165.compplete all as specified and directed.
S&F beam and channel sections with flange plates caps, bases splices, angle brackets, cleats and other connections and conforming to Fe-410-W (gde-E-250) quality A complete all as specified and directed.
M&L Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticai or to batter complete all as specified and as directed.
M&L Form work to sides of pillers, post, columns and stanchions as specified and directed.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces complete all as specified and as directed.
M&L Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces complete all as specified and as directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces complete all as specified and as directed.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M&L for RCC(design mix) M-25 in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC(design mix) M-25 in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC(design mix) M-25 in Chajjas complete all as specified and as directed.
M&L for RCC(design mix) M-25 in Slabs supported on walls, beams and collumns ub floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified and as directed.
M&L rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and fair without using extra cement using WPC all as specified and as directed. Note : WPC @ 3% by weight of cement shall be measured under saparate item.
M&L for Integral water proofing compound of Dr Fixit or equvalent all as specified and as directed.
M&L rendering 15 mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and fair without using extra cement all as specified and as directed.
M&L rendering 10 mm thick in CM 1:3 to soffits of slab finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified as as directed
M&L PCC 1:5:10 type E-2 (using 40 mm graded aggregate) thick as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for Cement concrete type B-1, 1:2:4 (20mm graded aggregate) 35 mm thick complete all as specified and as directed
M&L for Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto as per item 29 slab in skirting 20-25mm thick over 10 mm thick cement plaster 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for APP modified plastomeric bituminous water proofing membrane minimum 3mm thick and weighting not less than 3.0 kg / sqm of black plain finished reinforced with non woven polyster matt,with fusable finish laid over compatable bitumen primer at the rate of 0.35 Ltr/Sqm torching overlaps with a propane or abutane gas torch, with a over lap of 75mm at the sides and 100 at the ends and sealing incl applying a coat of cold emulsion bituminous primer all as per manufactur's instructions incl preparation of surface, including 15 mm thick cement screed bed in CM 1:4 complete all as specified and directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded
M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed.
S&F Rolled mild steel Framed work ~Fe-410 - W (Gde-E-250)quailty-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete all as specifed.
S&F35 mm thick 2nd class hardwood plain framed panelled shutters (two panel ) with lock rail and panels of 9mm CWR plywood. The size of rail and stile as per IS 1003 (Qart I), klin seasoned and chemically pressure treated complete all as specified and directed.
S&F 150mm long Mild steel barrel tower bolts, stove enamellled black, with bright bolt and fixed complete all as specified and directed.
S&F 150mm long Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc including making good the disturbed surfaces to match with the existing complete
M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories,GI metal flush box of 1.60 mm thick suitable for modular/conventional switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :-
(a) One light point controlled by one switch
(b) One ceiling/exhaust fan point controlled by one switch
(c) One socket outlet 5 Amps controlled by one switch on same board
(d) One socket outlet 5 amps controlled by one switch on independent board
(e) One bell point controlled by one bell push switch
All as per serial item No 116 above but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 1.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire.
S&F modular switch 6 Amps, one way, one module 240 volts, complete all as specified and directed.
S&F modular socket, 3 pin 6 Amps,240 volts, 2 module, complete all as specified and directed.
S&F modular switch 16 A, 1 module,240 volts, complete all as specified and directed.
S&F modular socket 6/16 A, 5 pin, 2 module, 240 volts, complete all as specified and directed.
S&F modular bell push with indicator 6 amps, one module, complete all as specified and directed.
S&F modular C/fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts , complete all as specified and directed.
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 7W LED bulb , complete all as specified and directed.
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size, complete all as specified and directed.
S&F ding dong bell, AC, 230 volts, single pole , complete all as specified and directed.
M&L for two single core (submain) PVC insulated cable with 2.5 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 1.5 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit & fixing accessories including cutting chases & making disturbed surfaces , complete all as specified and directed.
All as per above but with 4 sqmm and 2.5 sqmm as earth wire
Taking down unsv MCB DB incl MCBs any type/ size from wall/ existing main board and removing from site, complete all as specified and directed.
S&F sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 'C' curve, 240 Volt , complete all as specified and directed.
S&F MCB DB, single pole and neutral with 200 Amps rated bus bar, 12 way, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface, complete all as specified and directed.
S&F MCB DP/SPN, 63 amps, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs, complete all as specified and directed.
S&F MCB SP 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs, complete all as specified and directed.
S&F wall mounted LED batten with aluminium housing and initigrated electronic drive 20 watt fixture 4 feet provided for efficient heat dissipation with polycorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F LED Bulkhead luminaire, 10 watt of polycarbonate housing and enclosed with acrylic diffuser IP-65 protection incl connection, complete all as specified and directed.
S&F surface/wall mounted LED batten 10 watt 2 feet long, extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F exhaust fan, 230mm sweep, 230V, AC, steel body with louver shutter etc complete and connection from ceiling rose to fan terminal incl cutting of hole at wall for required size and making good disturbed surface, complete all as specified and directed.
Taking down C/fan any make/sweep from ceiling carefully, cleaning to remove any type of sticky dust with cleaning material as required and re-fixing in its original position with necessary connection after repairing, greasing, oiling, replacement of minor items such as pins, nut bolts, flexible wire etc incl spray painting in white colour, complete all as specified and directed.
Taking down geyser any make/size from wall carefully, cleaning to remove any type of sticky dust with cleaning material as required and re-fixing in its original position after required repair work incl necessary connection after repairing incl painting in white colour, complete all as specified and directed.
M&L for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI wire of size 4mm dia as earthing lead (upto the body of the equipment) by means of GI bolts, nuts, check nuts and washers and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) , complete all as specified and directed.
S&F Switch piano flush type 5/6 Amps single pole one way 230 Volts, complete all as specified and directed.
S&F Switch piano flush type 15/16 A single pole one way 230 Volts, complete all as specified and directed.
S&F Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volt, complete all as specified and directed.
S&F Socket Outlet 2 in 1 3/6 pin 5and15 Amp flush type 230 Volts, complete all as specified and directed.
S&F Sheet metal enclosure DB 8 way, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, DB to be flushed/ grouted on wall including connecting all connections of wire to MCBs with proper lugs & arrangements, complete all as specified and directed.
S&F MCB DP 40 Amp, 240 Volts, AC of breaking capacity 10 KA, 'B' curve, complete all as specified and directed.
S&F MCB SP 240 Volts, AC 6 to 32 Amps, breaking capacity 10 KA, 'B' curve complete
S&F wall mounted LED batten with polycarbonate housing and initigarated electronic drive 18/20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flexible copper conductor cable of suitable size , complete all as specified and directed.
S&F energy efficient wall mounted LED bulk head luminaire of polycarbonate housing and enclosed with acrylic diffuser 10 watt, 230 volt, AC, IP-65 protection , complete all as specified and directed.
S&F ceiling rose 6 Amp 3 terminal incl connection, complete all as specified and directed.
S&F Ceiling Fan 1200mm sweep, AC, 230 Volt, BEE 5 star rated with all accessories incl connection using 3 core copper flexible PVC wire of size 1.5 sqmm , complete all as specified and directed.
S&F electronic fan step regulator fiush type 120 watt, 230 Volt, complete all as specified and directed.
Supply and laying or fixing or passing through pipe 1100V grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 core nominal cross section in service connection , complete all as specified and directed.
M&L for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable, complete all as specified and directed.
M&L for one layer of bricks class 'B' laid flat across the cable for protection cover on the top of the sand cushioning for LT cable protection, complete all as specified and directed.
M&L for GI pipe 40 mm, light grade with clamps made out of MS flat 40 x 5 mm thick, fix on pole/wall , complete all as specified and directed.
M/s Vijay Enterprises
MOHIT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .