Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.6 L+₹4.7 L (15.8%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹35.9 L+₹6.0 L (20.1%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹37.0 L+₹7.1 L (23.8%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹38.0 L+₹8.1 L (27.2%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
Tender Value
₹45.0 L
EMD Value
₹89,950
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR/MAINT OF WINDOW/SPLIT ACs, WATER/DESERT COOLERS, REFRIGERATORS, DEEP FREEZERS AND OTHER CONNECTED ITEMS AND REPAIR/REPLACEMENT OF INTERNAL ELECTRIC WIRING LIGHT FITTING AND FIXTURES IN MD AND OTM ACCN AT AF STN SARSAWA UNDER GE(AF) SARSAWA
2024_MES_666320_1
8124/SAR-T-38/2024-25
Open Tender
Civil Works
Item Rate
330 days
GE(AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) SARSAWA
₹89,950
Yes
3 Oct 2024
17 Jul 2024
19 Sept 2024
17 Jul 2024
12 Sept 2024
31 Jul 2024
17 Jul 2024 - 31 Jul 2024
Amount
Servicing of split AC 1.5 /2 TR rating by removal of dust/dirt and carbon particles from indoor and out door unitwith water spray pump duly collected in jacket.
Servicing of window AC 1.5 TR rating by removal of dust/dirt and carbon particles from indoor and out door unitwith water spray pump duly collected in jacket.
S&F in replacement Condenser fan blade made out of aluminium/plastic as per matching to existing suitable for window /split type AC upto 2.0 ton capacity.
S&F in replacement Front grill suitalbe for window type AC upto 2 ton capacity
S&F in replacement of condensing coil suitable for window type room AC of capacity 1.5 ton.as per sample.
S&F in replacement cooling coil suitable for window type room AC of capacity 1.5 ton as per sample.
S&F in replacement Condensing coil suitable for split type AC of capacity 1.5 ton as per sample.
S & F in replacement cooling coil suitable for split type AC of up to capacity 1.5 ton as per sample.
S&F replacement of Indoor unit suitable for 1.5 TR split type AC.
S&F replacement of Outdoor unit suitable for 1.5 TR split type AC without compressor.
S&F in replacement PCB for window/Split type AC up to 2 Ton capacity suitable for existing make.
S&F in replacement Blower/ condensor fan motor of three speed, testing, commissioning complete suitable for window type 1.5 Ton AC suitable to operate 230V AC all as specified and directed.
S&F in replcement of blower motor suitable for indoor unit rating and capacity as per site requirement for upto 2.0 ton capacity Split type AC complete all as specified and directed.
All same as per ser item No 13 above here in before but suitable for condensor fan of out door unit of split AC up to 2.0 TR capacity.
S&F in replacement Blower fan made out of platic suitable for indoor unit split type AC upto 2.0 ton capacity.
Suuply & Fix in replacement of genuine company sealed compressor suitable for any type of existing make for split/ window type AC capacity 1.5 Ton with all fixing accessories complete all as specified and as directed by Engineer-in-charge. Make : HITACHI/LG/Blue Star Note : Repaired and repainted compressor not accepted only genuine compressor are accepted. with test report and one year warranty certificate from OEM.
All same as per ser item No.16 here-in-before but of split/ window type AC capacity 2.0 Ton. Make : HITACHI/LG/Blue Star
S&F in replacement Running Capacitor of 06-45 Mfd suitable for window / split type AC. Tibcon or equivalent
S&F in replacement Wiring kit suitable for 1.5 to 2.0 ton capacity AC complete.
S&F in replacement Air filter of existing make : synthetic, PVC suitable for 1.5 to 2.0 ton capacity AC window/Split type.
S&F in replacement Refrigerant gas filter and capilary assembly complete suitable for AC upto 2 ton capacity.
S&F in replacement gas charging pin valve
Taking out window type AC complete unit from any height/ any floor storey building and shifting to another locatiion in the same or other building in the complex as directed complete with making of opening of suitable size in wall/window as per site requirement.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves, disconnecting the suction and discharge copper pipe and shifting to another locatiion in the same or other building in the complex as directed .
Supply and charging the gas refrigerant (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, injection of nitrogen to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
All same as per item No 25 here-in-before but split type AC up to 2 TR capacity complete.
M&L for replacement of gas/Split valve ¼” for split AC 1.5 ton capacity
All same as per item no 27 above here in before but gas/split valve 1/2"
S&F in replacement compressor shut off valve 3/8" for split AC 1.5 ton capacity.
S&F in replacement compressor shut off valve 3/8" for split AC 2 ton capacity.
S & F in replacement of Copper tubing of size 1/4" suitble for any type of split type AC complete all as specified and directed.
All same as per Ser item No. 31 but size 1/2"
All same as per Ser item No. 31 but size 3/8"
All same as per Ser item No. 31 but size 5/8"
S&F in replacement PVC pipe of suitable size to drain out condensation water for any type of AC including necessary clamping arrangement to wall.
S&F in replacement PVC conduit 50mm dia including all clamps, tees & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey.
S&F in replacement of synthetic rubber tube for thermal insulation for refrigerant copper piping of size 1/4" internal dia split type AC complete all as specified and directed suitable for the under mentioned sizes.
All same as per ser item No. 37 but size 1/2"
All same as per ser item No. 37 but size 3/8"
All same as per ser item No. 37 but size 5/8"
S&F in replacement of window AC kit complete chasis including cooling coil, condensing coil, fan motor, blower, condensing fan and complete body without compressor suitable for window AC of capacity upto 1.5 ton complete all as specified and as diretced by Engineer-in-charge
S&F in replacement of remote for window / split type AC as per matching existing. Make:Universal/LG/Lloyd
S&F in replacement metal plug top 2 pole and earth, 20 Amps, 250 volts suitalbe for sheet metal enslousers complete all as specified and directed Make:Havells/L&T/Legrand.
S&F in repalcement metal clad socket 2 pole and earth, 20 Amps 250 volts suitalbe for sheet metal enclusers complete all as specified and directed.Make:Havells/L&T/Legrand.
S&F in replacement MCB single pole, 6-32 Amps, 10 KA 240 Volts, 50 HZ type. C series.Make:Havells/L&T/Legrand.
S&F in replacement sheet metal enclosure single pole and neutral with 2 pin and earth socket complete with one single pole MCB 6- 32 A, 10 KA 'C' seriesMake:Havells/L&T/Legrand.
S&F in replacement of PVC insulated FRLS sheathed flexible copper conductor 3 core 1100 volts round grade of size 2.50 Sqmm complete all as specified and directed..Make RR KABEL/Havells/Finolex
S&F in replacement of PVC insulated FRLS flexible copper conductor cable 1100 volts round grade, 3 core of size 1.5 Sqmm complete all all as specified and directed.
S&F in replacement of PVC insulated FRLS flexible copper conductor single core 1100 volts round grade of size 2.50 Sqmm complete all as specified and directed.
S&F in replacement of PVC insulated FRLS flexible copper conductor single core 1100 volts round grade of size 4 Sqmm complete all as specified and directed.
S&F in replacement of PVC insulated FRLS flexible copper conductor cable 1100 volts grade, single core of size 1.5 Sqmm complete all all as specified and directed.
M&L in replaqcement sub main wiring with two run of single core strated copper conductor FRLS cable of size 2.5 Sqmm and 2.5 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete all as directed.Note : 2 Run of 2.5 Sqmm + 1 Run of Earthwire shall be measured on one run.
M&L in replaqcement sub main wiring with two run of single core strated copper conductor FRLS cable of size 4 Sqmm and 4 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete all as directed. Note : 2 Run of 4 Sqmm + 1 Run of Earthwire shall be measured on one run.
S&F in replacement AC stand suitable for out door AC unit up to cap of 2 ton capacityany type complete with fastners stove enamelled.
M&L for repair to refrigerator any capacity upto 310 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified as directed.
M&L for repair to deep freezer any capacity upto 425 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified as directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets and water tank with rubber paint after scrapping the rust, peal of paint and preparation of surface complete all as specified and directed by Engr-in-Charge. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of wood wool pad (set of three) heavy duty for desert cooler complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of desert cooler submersible water pump 18 watt complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing. Make : Zoloto or equivalent
S&F in replacement desert cooler fan motor double bearing 145 watt,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing. Make Khaiten/Bajaj/Usha
S&F in replacement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as directed by Engr-in-Charge.
S&F in replacement plug top 3 pin 5 Amps Make : Anchor/Legrand/C&S
S&F in replacement motor capacitor 2.5/3.15/4 Mfd . Make Tibcon or equivalent
S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity upto 4000 Cfm
S&F in replacement of body without side panels made out of galvanised iron sheets of 18 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge.
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge.
S&F in replacement of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as directed by Engr-in-Charge.
S&F in replacement of PVC rubber pipe 15mm bore heavy duty including pvc elbow threaded suitable for insertion in flexible PVC pipe complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of PVC water distributor four way complete all as specified and as directed by Engineer-in-charge.
M&L for Servicing of voltage stabilizer AC single phase 2 to 5 KVA of any make by opening of body, cleaning internally checking and tightening of all terminal connections including replacement of worn out terminals connectors, screw, bolts etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement of transformer of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of buck and boost relay of voltage stabilizer of capacity upto 5KVA complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of electronic panel PCB of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of timer switch circuit of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of trigger transformer of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of voltmeter of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the green gas in the water cooler of any make and capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch for water cooler of any make & size complete all as specified and directed.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of zinc oxide primer by spray painting.
S&F in replacement fan motor ISI marked suitabe for water cooler capacity upto 40/80 ltrs of any make complete all as specified and directed.
S&F in replacement of condenser fan of any make suitable for water cooler upto 40/80 ltrs capacity complete all as specified and directed.
S&F in replacement 15 mm dia PTMT connection of length upto 600mm with nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 40/80 ltrs capacity complete all as specifed and directed.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 40/80 ltrs capacity complete all as specifed and directed.
S&F in replacement company sealed compressor unit of water coolers of capacity 40/ 80 ltrs. Make : HITACHI/LG/Blue Star
S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding fastening angles, as necessary gusset plates, rivetingetc conforming to Fe.29.Gde-E-165
M&L Painting to new or previously untreated steel surfaces of any description over 10 cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chromic primer in camaflage pattern or plain or pattern as decided by Engir-in-charge
Supply only Digital Anemometer complete set all as specified and directed Engineer-in- Charge. Note for ser item No. 1 to 93 :- 1. The contractor shall provide and deploy sufficient technician with helpers (as approved by GE / Engineer-in-charge) for maintenance of summer appliances at Tech Area and domestic area and contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints & complete the same complaint detailed by JE E/M /Engineer-in-charge with in 24 hrs. 2. The complaints shall be rectified with in 24 hrs. If the complaints is/are not complete on same day (except repair/ replacement of major items like repair/ replacement of compressor, cooling coil, condensing coil, fan motor ducting work of AC plant & insulation work. these work can be completed in time period (max 36 Hrs) as decided by Engineer-in-charge after which recovery shall be made as under), the recovery will be done as follows (a) After 24 Hrs Rs - 1000.00 Per complaint per day. The decision of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at AF Station Sarsawa 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.
Taking down carefully copper / aluminium point wiring light / fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc. removing from site and making good disturbed surface of wall, floor etc complete all as specified and as directed.
M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-One light / fan point controlled by one way switch
All as per above item No-95 here in before but One 5 Amp socket outlet on independent board.
All as per above item No-95 here in before but One 5 Amp socket outlet on same board.
All as per above item No-95 here in before but One bell/buzzer point controlled by one bell push
All as per above item No-95 here in before but One light point controlled by two 2-way switch
All as per above item No-95 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M&L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade with PVC rectangular block of suitable size including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :- One light / fan point controlled by one way switch
All as per above item No-101 here in before but One 5 Amps socket out let point controlled by one 1-way switch on independent board.
All as per above item No-101 here in before but One 5 Amps socket out let point controlled by one 1-way switch on same board.
All as per above item No-101 here in before but One bell/buzzer point controlled by one bell push
All as per above item No-101 here in before but One light point controlled by two 2-way switch
All as per above item No-101 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M & L for replacement of existing conduit point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade drawn through existing conduitwith MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover ( cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan point controlled by one switch.
All as per above item No-107 here in before but One bell point controlled by one bell Push
All as per above item No-107 here in before but One 5 Amps socket out let point controlled by one switch on independent board.
All as per above item No-107 here in before but One 5 Amps socket out let point controlled by one switch on same board.
All as per above item No-107 here in before but with 2.5 Sqmm nominal cross sectional area electric cable for 15 Amps socket outlet point controlled by one switch on independent board complete.
S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 2-in-1, 6 pin 5 amp and 15 amps all as specified and directed.
S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed.
S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
S&F in replacement switch 6 amps modular type one one way complete all as directed.
S&F in replacement switch 16 amps modular type one one way complete all as directed.
S&F in replacement electronic fan regulator Step type complete all as specified and directed.
S&F in replacement bell push flush type 5 amp one way ISI Marked complete all as specified and directed.
S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed.
S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed.
S & F in replacement of Lamp holder bakelite type with back plate suitable for batten fittings complete all as specified as directed
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F in replacement of sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F in replacement of Rigid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 8 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate.
S&F in replacement of single pole and neutral enclosure with 2 pin and metal earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and as directed.Make-Havells/Indoasian/Legrand
S&F in replacement of Double door three phase distribution board 4 way loadline VTPN when MCCB to be used as incomer and made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks , poly layer for protection complete all as specified and directed (Note:-(a) MCCB and MCBs are to be measured and paid for seperately. (b) Make of MCBs and DB should be same.
S&F in replacement of Double door distribution board 4 way TPN when MCB to be used as incomer powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, complete all as specified and directed (Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.)
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F in replacement MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCB SPN 50 to 63 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCB TPN 63 Amps, 415 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCCB , 125 Amps, 4Pole with adjustable thermal setting and rupturing capacity 16 kA complete all as specified and directed.
S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed.
S & F in replacement of modular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified as as directed.
S & F In replacement of Piano type switch 2 way, 5 Amp,1 module ISI Marked complete all as specified and as directed.
S&F in modular blanking plate, 1 module ISI Marked complete all as specified and as directed.
S&F in replacement metal flush box 3 module all as specified and directed.
S&F in replacement metal flush box 6 module all as specified and directed.
S&F in replacement metal flush box 8 module all as specified and directed.
S&F in replacement for white cover plate with frame, 3 module all as specified and directed.
S&F in replacement for white cover plate with frame, 6 module all as specified and directed.
S&F in replacement for white cover plate with frame, 8 module all as specified and directed.
Supply and fixing in repair of Earthing to DBs with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
M & L in repair for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed.
S&F in replacement enviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting modular type with polycarbonate housing ,high efficient LEDs with opal diffuser and IP65 protectio, lumen efficacy 85 lm/watt with colour temerature 6500K, THD≤ 20 CRI>80,2.5 kV surge protection all as specified and directed.
S&F 9 watt LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F 12 watt LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED Polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 9/10 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
S & F in replacement enviroment friendly recess/surface mounting 36 watt LED flat panel 2'x2' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80 including connection with existing wire and all accessaries all as specified and directed.
S & F in replacement enviroment friendly recess/pendent mounting 24 watt LED flat panel 1'x1' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80 including connection with existing wire and all accessaries all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 5/6 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
S & F in repair plastic laminated bakelite sheet cover of Hylam brand including cutting holes for switches, sockets etc as pre requirement including fixing with machine screws and washer complete of following sizes:- 10" x 12" size
All as per above item No-160 here in before but 8" x 10" size
All as per above item No-160 here in before but 8" x 6" size
All as per above item No-160 here in before but 7" x 4" size
All as per above item No-160 here in before but 4" x 4" size
M&L for Shifting of existing electric Energy Metrer from existing location to directed location including box and connecting to existing submain circuit complete all as specifed and directed
S&F in replacement of Energy meter Box Flame retardent polycarbonate body including all fixing arrangement like DIN rails mounting plate connection boxes fastning screw protection plate extra suitable to accomodate single Phase energy meter with locking arragement complete all as specified and directed.
Taking down electric energy meter of any size and type and deposite to MES store yard complete all as specified and directed.
Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 60 Amps, AC 240 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia on surface/wall/ceiling including all flame proof conduct fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed by Engrs-in-Charge.
Supply and fixing flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc all as specified and directed. Make : Flexpro/Sudhir/Baliga/Shyam.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed size. Note :- (a) All fittings shall be ISI marked and shall have approval of CMRI Dhanbad . (b) Original Test certificate of Manufacturer shall be produced by Contractor .
M&L for fixing PVC gang box for mounting one switch and one socket of 5 Amps including all accessoriese complete all as specifies and directed.
M&L for fixing PVC gang box for mounting one switch and one socket of 15 Amps including all accessoriese complete all as specifies and directed.
Supply and fixing of PVC Casing capping 20/25mm ISI marked all as specified and as directed by Engineer-in-charge.
S&F in replacement of Cable PVC insulated unsheathed single core 1100V FRLS grade stranded flexible copper conductor of size 1.5 sqmm complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unsheathed single core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unsheathed twin core of 23/0.0076 size flexible copper conductor complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unarmoured three core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed.
Supply and fixing 25 mtr long 2.5 cm wide and atleast .125 mm wall thickness self adhesive PVC insulated electrical tape roll of good quality complete all as specified and directed.
Supply and fixing in replacement of PVC round shape junction box cover of suitable size including fcomplete all as specified and as directed.
Taking down light fittings of any type any size any location complete all as specifed and directed.
Taking down DB including old U/s MCB/MCCB of any size any type from any location complete all as specifed and directed.
S&F in replacement of recesses/suface mounted with ring square/round shape slim downlighter of 12 watt capacity with colour temperature cool day white/warm white as per requirement , Lumens 120, CRI more than 80 as per sample and site requirement including all accessore complete all as specified and directed.
S & F in replacement enviroment friendly recess/pendent mounting 36 watt LED flat panel 2'x2' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80, Colour Temerature 3500/4000 K (Warm White) including connection with existing wire and all accessaries all as specified and directed.
S & F in repair PVC rectangular block for mounting switches, sockets , fan regulator etc with 3 mm thick plastic laminated sheet cover of following sizes:- 250 x 200 x 50 mm size
All as per above item No-185 here in before but 200 x 150 x 50 mm size
All as per above item No-185 here in before but 175 x 100 x 50 mm size
All as per above item No-185 here in before but 100 x 100 x 50 mm size
S&F in replacement of old unserviceable decorative type wall mounted with new wall comet light fitting without LED bulb pin type B22 cap complete all as specified and directed. Make- Philips 30575 or equivalent
S&F in replacement of 09 watt 2 star LED bulb with B22 /B27 Base cap as required, 1200 lumens ,Colour rating Index 80,colour temp warm white ,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F in replacement metal flush box 4 module all as specified and directed.
S&F in replacement for white cover plate with frame, 4 module all as specified and directed.
S&F in replacement metal flush box 12 module all as specified and directed.
S&F in replacement for white cover plate with frame, 12 module all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 5 Watt LED round shape downlighter recess/suface mounted operating voltage range 140v to 270 V lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature warm white, including all accessaries all as specified and directed. Make- Crompton/Syska/orient
M/s badrinath Traders (BID ID -3093558)
SUBHASH CHAND CONTRACTOR (BID ID -3084481)
Naqli Lal Sharma and Arun Sharma (BID ID -3084546)
PANWAR CONSTRUCTIONS (BID ID -3085811)
RADHA ENTERPRISES (BID ID -3076533)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .