Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 CrAccepted-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹8.2 Cr Quoted ₹8.4 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹8.7 Cr+₹30.5 L (3.63%)Rejected-Finance NATIONAL TOWER 5TH FLOOR SCO 89 DSC RANJIT AVENUE AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹8.7 Cr+₹30.5 L (3.63%) | L2 | Rejected-Finance L2 |
Tender Value
₹7.5 Cr
EMD Value
₹7.0 L
Closing Date
22 Sept 2023, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
ADDN/ ALTN TO BLDG NO. P-1 OF MH JRC UNDER GE (EAST) JALANDHAR CANTT
2023_MES_607545_1
81052/E8
Open Tender
Civil Works
Item Rate
365 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (East) Jalandhar Cantt
₹7.0 L
Yes
4 Nov 2023
19 Jul 2023
30 Sept 2023
19 Jul 2023
22 Sept 2023
8 Sept 2023
Amount
Note : Please refer Schedule 'A' Notes given on serial page No. 20(R), 21, 22(R), 22(A) to 22(D) of tender documents.
B/R PORTION WORKS
Dismantling wall and ceiling boards’ fibre, pulp, insulations etc or insulation boards/ slabs/ blankets any thickness including cover fillets complete all as specified and as directed
Supply and fixing false ceiling with powder coated Hot dipped Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having curled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and necessary notching and preparing holes complete all as specified and directed
Material and labour for 4mm thick non asbestos designer ceiling board/ E-board of size 600x600 fixed or laid/ inserted to timber/ GI/ Aluminium frame work with screws complete all as specified and directed
Dismantling floor hearth or wall tiling/ china mosaic including cement mortar bedding (but not backing), rubbish off the premises complete all as specified and directed.
Material and labour for non-skid coloured ceramic tiles (premium quality) 7 to 8mm thick square/ rectangular area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match, laid over and including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed
Material and labour for glazed ceramic light colour tiles (premium quality) in vertical surface such as skirting/ dado etc of size 450x300x7mm thick set and jointed in cement slurry and pointed in white or colour cement to match the tiles over and including 10mm thick plaster in CM 1:4 to receive the tiles complete all as specified and directed
Material and labour for glazed ceramic dark coloured tiles (premium quality) in vertical surface such as skirting/ dado etc of size 450x300x7mm thick set and jointed in cement slurry and pointed in white or colour cement to match the tiles over and including 10 mm thick plaster in CM 1:4 to receive the tiles complete all as specified and directed
Roughening surface of old concrete floors by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3 kg of cement per Sqm complete all as specified and directed.
Material and labour for vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20mm thick cement screed bedding layer in cement mortar 1:6 complete all as specified and directed
Material and labour for vitrified Ceramic tiles Dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20mm thick cement screed bedding layer in cement mortar 1:6 complete all as specified and directed
Material and labour for vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 Sqm in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over including 10mm thick rendering in cement mortar 1:4 walls, finished even and rough to receive the top layer complete all as specified
Material and labour for 20mm thick granite (of any type) work (table rubbed and polished) as in flooring, in steps, jambs, pillars, window cills, cooking platforms and like in cement-mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 20mm thick cement screed bedding layer in cement mortar 1:6 complete all as specified and directed
Material and labour for 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall), skirting including 10mm thick cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Material and labour for marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of makrana white over 20mm thick screed CM (1:4) all as specified and directed. Details of Qty B/R Portion-114.00 Sqm Lift Work-10 Sqm
Material and labour for makrana white marble work (table rubbed and polished) for wall lining (veneering to wall) 25mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed
Demolition of brickwork or stone/ boulder masonry, built in lime cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed Details of Qty B/R Portion-43.29 Cum Sewage Line-160.00 Cum Area Drainage-87.00 Cum
Material and labour for brick work with sub class ‘B’ brick, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed Details of Qty B/R Portion-43.29 Cum Area Drainage-71.63 Cum
All as per srl item No. 2.17 here-in-before but except brick Details of Qty B/R Portion-11.75 Cum Area Drainage-34.80 Cum
Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls with old size bricks built in cement mortar 1:4 complete all as specified and as directed
Demolition of reinforced concrete roofs, floors (other than ground floors), beams, stair cases, landing, chajjas and similar suspended work of any description and in any position not otherwise specifically provided for complete all as specified and directed
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed Details of Qty B/R Portion-7.50 Cum Sewage Line-10.00 Cum Area Drainage-35.00 Cum
Material and labour for reinforced cement concrete (1:1.5:3) using 20mm graded stone aggregate as in slabs, lintels, beams, in floors, roofs, landing, balconies, canopies, and shelves and the like complete all as specified and directed
Material and labour for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate as in chajjas, lintels, beams and the like complete all as specified and directed
Supply and fixing rough finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves , counter and similar work not exc 200mm thick complete all as specified and directed
Material and labour for fair finish form work to chullah hoods, chajjas, troughs and similar items including edges to sides complete all as specified and directed.
Material and labour for Mild steel TMT bars 6mm to 8mm dia and cut to length bent to shape required, including cranking, bending and binding as in stirrups, spacers and binders etc. with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Material and labour for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. Details of Qty B/R Portion-2194.41 Kg Sewage-1700.00 Kg Area Drainage-1220.00 Kg
Taking down cement plaster on brick/ stone masonry including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed Details of Qty B/R Portion-6423.61 Sqm Area Drainage-1529.88 Sqm Lift Work-45.00 Sqm
Material and labour for 5mm thick cement plaster in cement mortar 1:3 as on ceiling, soffits of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified and as directed. Details of Qty B/R Portion-1453.21 Sqm Lift Work-10.00 Sqm
Material and labour for 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and directed. Details of Qty B/R Portion-3096.97 Sqm Lift Work-35.00 Sqm
Material and labour for 15mm thick cement plaster in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and fair without using extra cement complete all as specified Details of Qty B/R Portion-1390.20 Sqm Area Drainage-2299.00 Sqm
Material and labour for rendering rough cast cement plaster over and including under coat of cement and sand mortar (1:3) not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting stone or fine gravel mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even complete all as specified and directed
Dubbing out Cement Plaster (1:4) average complete all as specified and as directed 20mm thick on irregular face of walls/ ceilings/ chajja complete all as specified and directed
Material and labour for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed
Material and labour for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
Material and labour for preparation of new surfaces of ceiling and applying two coats of water based premium anti-bacterial interior paint over a coat of suitable sealer/ primer as directed by manufacturer specification complete all as specified or as directed by Engineer-in-Charge.
Material and labour for preparation of old surfaces of ceiling and applying two coats of water based premium anti-bacterial interior paint over a coat of suitable sealer/ primer as directed by manufacturer specification over a coat of primer and 1mm thick putty and complete removal of existing treatment complete all as specified or as directed by Engineer-in-Charge.
Material and labour for preparation old plastered surfaces of walls and applying one coats of oil emulsion distemper complete all as specified and directed
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer and 1mm thick putty complete all as specified and directed
Material and labour for preparation of old plastered surface of wall after complete removal of existing treatment and applying 1mm thick wall care putty and two coats of Acrylic Smooth interior anti-fungal paint over a coat of primer complete all as specified and directed
Material and labour for preparation of new plastered surfaces of walls with two coats of Acrylic Smooth interior anti-fungal paint over a coat of primer and 1mm thick wall care putty complete all as specified and directed
Material and labour for preparation of old plastered surfaces of walls with complete removal of existing treatment and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15439:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed
Material and labour for preparation of newly plastered surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15439:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, oil emulsion over a coat of primer complete all as specified and directed
Taking down chowkhats or frames with shutter (without taking off shutters from the frames) area not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutters from the frames) area exc 1.5 sqm but not exc 4.0 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutters from the frames) area exc 4.0 sqm but n.exc 6 Sqm each complete all as specified and directed.
Supply and fixing 30mm thick factory made solid panel PVC door shutter consisting of frame made out of MS tube for top and bottom rail, MS frame shall be covered with heat moulded plain colour PVC “C” channel having strip of 20 mm width stuck inside with solvent cement rail on either side and as gap inset for top rail and bottom rail, welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement Supply and fixing in the frame and site as specification all as specified.
Supply and fixing solid PVC door frame of size 50mmx47mm made out of 5mm plain, colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing
Supply and fixing aluminium anodised barrel tower bolt 150 mm long of extruded section complete all as specified and directed
Supply and fixing aluminium anodised handle cast type 125 mm, anodised complete all as specified and directed
Supply and fixing 75mm butt hinges extruded aluminium alloy with mild steel hinge pin anodized and fixed complete all as specified and directed.
Material and labour for 35mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in clause 8.24 (a) of SSR Part-I; supplied and fitted to chowkhats complete all as specified and directed
Supply and fixing 32mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed
Supply and fixing 100mm size butt hinges medium weight cold rolled mild steel all as specified and directed
Material and labour for 200mm long aluminium anodized barrel tower bolts of extruded section and fixed complete all as specified and directed
Supply and fixing aluminium anodised handle cast type 150 mm, anodised complete all as specified and directed
Supply and fixing aluminium alloys anodised sliding door bolt with hasp, staples 250mm (Bolt Type) and fixing clip of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium alloys and fixed complete all as specified and directed
Supply and fixing 75mm long aluminium anodised extruded type floor door stopper of double legged with rubber shoes in bottom complete all as specified and directed
Supply and fixing steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises glazed skeleton shutter ERW sec 50mm x 20mm and 1mm thick with two openable leaf consisting two Nos sash bars of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mmx25mm and 1.25mm thick including cutting holes and making good dismantled portion PCC (1:2:4) type B-1 four Nos for each window) including following fittings welded to frame shutter: - (a) Hold fast, 150mm long of 12mm x 3mm made to shape-04 Nos per window. (b) Handle of z section 20mm x 25mm, 100mm long 01 Nos per leaf (c) MS tower bolt 150mm long- 2 Nos per leaf (d) z section 20mm x 25mm, (e) 100mm long stopper - 01 No per leaf (f) MS pintal hinges of size 75mm x 12mm- 2 Nos per leaf (g) Fabrication & fixing arrangement as per Drg No CEJZ/TD-06/07. Note: Wire mesh and painting shall be measured and paid separately under respective item of schedule.
All as per srl item No. 2.59 here-in-before but gauged shutters without sash bars complete all as specified and directed.
All as per srl item No. 2.59 here-in-before but as in ventilators complete all as specified and directed.
Material and labour for galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete, fixed in repairs, all as specified and directed
Supply and fixing 3mm thick figured glass pinhead type in squares n.exc 0.5 sqm each pane complete all as specified and directed
Supply and fixing in repair 3mm thick plain glass pin head type and glazing with oil putty in squares n. exc 0.5sqm in each pane including hacking out complete all as specified and directed
Material and labour for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in filling of pressed steel door/ window frame complete all as specified and directed
Supply and fixing framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, framed guard bars, barred iron doors, ladders, framed balusters, walk ways railings and similar work conforming to Fe-290, Gde-E-165, complete all as specified and directed
Supply and fixing framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 410-W (Gde-E-250) complete all as specified and directed.
Supply and fixing cast iron door closer hydraulically regulated designation No 3 universal type suitable for door shutter of width between 851 to 1000mm having weight between 61 kg to 80 kg and fixed, complete all as specified and directed.
Material and labour for preparation of newly wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of old wooden surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint with one coat of primer red oxide complete all as specified and directed.
Material and labour for preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
Supply and fixing in repairs mild steel, powder coated in (wooden finish) 25mm dia heavy duty superior quality curtain rod with brackets, stops, rollers etc as approved by GE complete all as specified and directed
Supply only finials for curtain rod as approved by GE complete all as specified and directed.
Material and labour for cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting not exceeding 10cm girth complete all as specified and directed
Taking down 15mm bore old GI tubing and connection including fittings complete all as specified and directed.
Taking down 20mm bore old GI tubing and connection including fittings complete all as specified and directed.
Taking down GI Tubing 40/50mm dia and connection including fittings complete all as specified and directed
Supply and fixing 15mm bore galvanized iron tubing medium grade with all fittings, fixed to walls, ceiling or laid in floors, complete all as specified and directed.
Supply and fixing 20mm bore galvanized iron tubing medium grade with all fittings, fixed to walls, ceiling or laid in floors, complete all as specified and directed.
Supply and fixing GI tubing 40 mm bore fixed to wall/ ceiling or floor complete all as specified and directed
Supply and fixing GI tubing 50 mm bore fixed to wall/ ceiling or floor complete all as specified and directed
Supply and fixing in repairs Stop valve / Angle valve fancy type cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed.
Supply and fixing in repairs Stop valve cast copper alloy chromium plated with long shank and cup (concealed type) screwed down high pressure with capstan headed screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed.
Supply and fixing in repairs 15 mm bore bib tap cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for iron pipe in repairs complete all as specified and directed.
Supply and fixing WHB mixer chromium plated brass, size 15mm bore screwed down high pressure with lettered Hot and Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.
Supply and fixing in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15 mm pipe complete all as specified and directed
Supply and fixing in repairs vitreous china squatting pan Orissa pattern of size 580x440 mm complete all as specified
Supply and fixing in repairs vitreous china wash down water closet white with concealed S-Trap/P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device fixed complete all as specified and directed
Supply and fixing in repairs PVC 10 litre syphonic action type flushing cistern, low level with inlet, ball valve, float and handle (ISI Marked) including brackets, flush pipe PVC 32mm bore and connection to WC complete all as specified and directed.
Supply and fixing in repair PVC connection 450mm long suitable for 15mm bore pipe including PTMT nuts complete all as specified and directed.
Supply and fixing in repairs vitreous china wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, waste pipe , mild steel brackets fixed to wall, complete all as specified and directed
Supply and fixing in repairs vitreous china wash hand basin white, oval type, size 450 x 600 mm size counter sunk/ embedded in RCC/ Granite complete all as specified and directed
Supply and fixing in repairs chromium plated brass shower rose, swivel type of size 150mmx150mm fixed to pipe complete all as specified and directed.
Supply and fixing in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste, and waste pipe including bedding in cement mortar on dwarf wall or fixing cantilever brackets and connecting union to pipe, overall size 495mmx420mm bowl size 410mmx330mmx160mm, complete all as specified and directed
Supply and fixing in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with waste pipe plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed
Supply and fixing in repairs Chromium plated grating 125mm dia circular with or without hole of approved make and fixing with cement mortar 1:3 on Nahani trap or floor trap complete all as specified and directed.
Dismantling of cast iron drain pipe jointed with cement mortar/lead joint and taking out from wall/floor if reqd /75/100mm complete all as specified and directed
Supply and fixing 100mm bore cast iron spun pipe in any length with or without ears, with cement joints fixed to walls complete all as specified
All as per ser item No. 3.00 here-in-before but except pipes complete all as specified and directed.
Supply and fixing 75mm bore cast iron spun pipe in any length with or without ears, with cement joints fixed to walls complete all as specified
All as per ser item No. 3.02 here-in-before but except pipes complete all as specified and directed.
Supply and fixing 100mm bore Cast Iron Spun pipes, Soil, waste and vent pipes in any length with or without ears, with cement joints, laid in floors or trenches complete all as specified and directed
Supply and fixing 75mm bore Cast Iron Spun pipes, waste and vent pipes in any length with or without ears, with cement joints laid in floor or trenches complete all as specified and directed.
Supply and fixing 100mm bore CI bend/ Tee complete all as specified and directed
All as per ser item No. 3.06 here-in-before but 75 mm dia complete all as specified and directed.
Supply and fixing 100mm branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and directed.
All as per ser item No. 3.08 here-in-before but 75 mm dia complete all as specified and directed.
Supply and fixing 100mm bore cast iron sanitary connection 'S' or 'P' branch, complete all as specified and directed
Supply and fixing in repairs cast iron Nahni trap with grating including jointing to waste pipe for 75 mm bore fixed in cement concrete (1:2:4) type B-1 complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs cast iron floor trap with grating including jointing to waste pipe for 75 mm bore fixed in cement concrete (1:2:4) type B-1 complete all as specified and directed by Engineer-in-Charge
Material and labour for salt glazed stoneware gully traps 150mmx150mm, square or round mouthed, type 'P' /S including setting and jointing with drain pipe with cement mortar (1:1) complete all as specified and directed
Supply and fixing in repairs vitreous china half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement including spreader complete all as specified and directed
Supply and fixing vitreous china urinal partition white of size 310x700 mm complete all as specified and directed
Supply and fixing PVC waste pipe 32mm dia flexible for wash hand basin complete all as specified and directed Make -Polyplast/ Symet or equivalent
Demolition of concrete of any description and in any position not otherwise complete all as specified. Details of Qty B/R Portion-259.50 Cum Area Drainage-35.00 Cum
Material and labour for water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:- (a) Application of two component Acrylic modified Cementitious coating:- (i) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coating and achieve a gripping profile that is clean, dry and free from laitance and dry other form of surface contamination. The installation instructions in manufacture's published literature should be strictly complied with, including but not limited to the following:- (ii) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr Fixit 302 SBR latex/ Perma latex SBR/FOSROC Nitabond SBR latex/Asian paint latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required. (iii) Dampen all surfaces immediately ahed of application of Acrylic modified Cementitious coating of sika Top Seal-107/Brush Bond FOSROC/Dr Fixit/STP/CICO. (iv) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified cementitious coating of SIKA Top Seal-107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions. (v) Apply glass fabric sheet of SIKA Fab 1/FOSROC/Dr Fixit/STP whilst the first coat is wet. (v) Once touch dry, apply second coat of Acrylic modified cementitious coating of SIKA Top Seal -107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions on the entire area. (vi) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat. (vii) The waterproofing coating should be taken to a height minimum 300mm above the finished floor level on the vertical surfaces. (viii) It is essential to cure Acrylic modified cementitious coating immediately after application (minimum 6-8hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking. (ix) A protection plaster 12-15mm thick) in CM 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645.
Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with SIKA Plastocrete over the applied water proofing coating on horizontal surfaces. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645. (x) All the corners and joints should be pre-treated with an elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of Make SIKA Seal Tape/FOSROC/Dr Fixit/STP. (xi) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations. (xii) Waterproofing treatment has to be carried out through applicators authorised. (b) All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealant. (c) All CI traps in sunken slab to be enclosed with PCC 1:1.5:3 (Min 15cm) all around. (d) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40mm stone aggregate) complete all as specified.
(e) Providing drainage spout pipe GI 40mm dia bore light grade upto outside of outer wall (Approx 450mm to 600mm long ) including cutting to existing wall and making good the disturbed surface complete all as specified and directed. (f) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish all as specified. Note : Items No. 3.18 (d), (e), (f) shall be measured and paid separately under relevant items.
Material and labour for cement concrete (1:5:10) type E-2 (using 40mm stone aggregate) as in sunken flooring complete all as specified and directed
Supply and fixing drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600 mm long) including cutting to existing wall and making good the disturbed surface complete all as specified and directed.
Material and labour for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in flooring for laying floor finish complete all as specified and directed
Material and labour for sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guards and railing 60cm long complete all as specified.
Supply and fixing brass chromium plated tubular towel rail of 20mm dia D type 600mm long complete all as specified and directed
Supply and fixing hand shower (health faucet) with 8mm dia 1 mtr long flexible tube and wall hook chromium plated complete all as specified and directed. Make : Jaguar/ Plumber/ Hindware as approved by GE.
Supply and fixing brass CP Jet for pedestal pattern water closet including PVC flexible pipe 600 mm long with necessary fitting, valves high pressure with polythene float and fly nut for 20 mm bore pipe complete all as specified and directed
Supply and fixing toilet paper holder of chromium plated fixed to walls with chromium plated (CP) brass screws, complete all as specified and directed
Supply and fixing brass CP telephonic mixture with shower for 15mm bore pipe complete all as specified and directed
Supply and fixing soap dish stainless steel chromium plated fixed with brass screws and rawl plug complete all as specified and directed
Material and labour for cutting holes in brick walls, built in cement mortar for Inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required in exc. half brick but not exc. one brick thick walls, complete all as specified and as directed
Material and labour for 100mm thick PCC (1:2:4) type B-2 (using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed
Supply and fixing galvanised steel water tubes medium grade 32mm bore, with and including all GI fittings fixed to walls, ceiling or laid in floors, Including making good complete all as specified and directed
Dismantling cast iron work of any description complete all as specified and directed.
Supply and fixing modular storage system for hospital consisting combination of drawers, shelves and shutters of cabinets made of stainless steel Gde 305 of thickness 1.25 mm including all fittings and fixtures such as telescopic ISI channel for drawers, stainless steel handles of size 75mm for drawers and 125mm for main shutters, complete all as specified & shown in drawing No. GE/E/WD/01/2021 sheet 1/2 and 2/2 Make of stainless steel : Jindal/ TATA/ Bhushan Steel/ Jyoti Steel Mumbai
Supply and fixing of sheet glass, 5.5mm of thickness, ordinary quality and glazing with aluminium clip with rubber beading in aluminium door/ window/ vent/ partition all as specified and directed
Supply and fixing powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Supply and fixing in repairs aluminium mortice lock, vertical type size 100mm 4 lever complete all as specified and directed
Supply, installation, testing and commissioning of flooring seamless (vinyle flooring) with perfectly curved flash-coving, resistance to mechanical stress and dynamic loads and having ESD/ EMI (conductive) protection characteristics, 2mm thick, washable complete all as specified and directed. Make : Gerfloor
Supply and fixing in repair stainless steel pipe railing of 50mm dia meters in horizontal and 25mm dia stainless steel pipe in vertical at at a distance 25cm between step to step , all welded together, vend to shape as directed and fixing both ends in floor complete all as specified and directed
Supply and fixing CI bend (any radius) diminishing pieces or tapers 100mm bore pipe with oval access door complete all as specified and directed
All as per srl item No. 3.39 here-in-before but 75 mm CI pipe
Extra over cast iron pipes and fittings if lead joint is provided in lieu of cement joint for 100 mm bore pipe complete all as specified and directed
Extra over cast iron pipes and fittings if lead joint is provided in lieu of cement joint for 75mm bore pipe complete all as specified and directed
Supply and fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joiints fixed to trenches or in floor complete all as specified and directed
Supply and fixing PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joiints fixed to trenches or in floor complete all as specified and directed
Supply and fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joiints fixed to wall complete all as specified and directed
Supply and fixing PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joiints fixed to wall complete all as specified and directed
Supply and fixing PVC (SWR) bend any radius 110mm bore complete all as specified and directed
Supply and fixing PVC (SWR) bend any radius 75mm bore complete all as specified and directed
Supply and fixing PVC (SWR) junction single (single T) 110mm bore complete all as specified and directed
Supply and fixing PVC (SWR) vent cowl 75/110mm bore complete all as specified and directed
Supply and fixing in repair XPM sheet of mesh size 25mm x 6mm, dimension of strands 2.50 x 1.25 cut to length, bent to shape and fixed in steel member complete all as specified and directed
Supply and fixing 3mm thick aluminium composite panel sheet as in partitions fixed with self tapping screw or as manufacturer instructions complete all as specified and directed
Supply and fixing mild steel of grade (Fe 410-W, Gde E-250) quality A in flat round or square bar complete all as specified and directed
SEWAGE LINE SUPPLY WORKS
Excavating in soft/ loose soil in trenches, n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out complete all as specified and directed Details of Qty Sewage Line-650.00 Cum Lift-31.50 Cum Central AC Plant-30.50 Cum Area drainage-118.00 Cum
All as per srl item No. 4.01 here-in-before but depth exc1.5m but not exc 3m complete all as specified and directed
All as per srl item No. 4.01 here-in-before but hard/ dense soil.
Demolition and breaking up drain pipes 150mm internal diameter (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed
Demolition and breaking up drain pipes 200mm internal diameter (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed
Demolition and breaking up drain pipes 250mm internal diameter (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed
Demolition of concrete of any description and in any position not otherwise specifically provided for as directed
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for pipes of 150mm bore complete all as specified and directed Note : Pipes shall be measured and paid separately.
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for pipes of 200mm bore complete all as specified and directed Note : Pipes shall be measured and paid separately.
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for pipes of 250mm bore complete all as specified and directed Note : Pipes shall be measured and paid separately.
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for pipes of 300mm bore complete all as specified and directed Note : Pipes shall be measured and paid separately.
Supply and fixing 150mm bore RCC pipes (ISI Marked), class NP-3, laid and jointed in cement mortar with collars, laid in trenches at any depth and tested complete all as specified and directed. Note : Excavation, earth work & concrete shall be paid separately
Supply and fixing 200mm bore RCC pipes (ISI Marked), class NP-3, laid and jointed in cement mortar with collars, laid in trenches at any depth and tested complete all as specified and directed. Note : Excavation, earth work & concrete shall be paid separately
Supply and fixing 250mm bore RCC pipes (ISI Marked), class NP-3, laid and jointed in cement mortar with collars, laid in trenches at any depth and tested complete all as specified and directed. Note : Excavation, earth work & concrete shall be paid separately
Supply and fixing 300mm bore RCC pipes (ISI Marked), class NP-3, laid and jointed in cement mortar with collars, laid in trenches at any depth and tested complete all as specified and directed. Note : Excavation, earth work & concrete shall be paid separately
Material and labour for brick work with sub class ‘B’ bricks, old size straight or curved on plan exc 6m mean radius, built in cement mortar (1:4) including corbelling and arches, raking out joint internally and flush pointing externally as the work preceeds complete all as specified and directed
Material and labour for precast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in landings, bed plates, pintle blocks, anchorage blocks, cover slabs (for manholes etc) shelves and similar articles with plaint faces and set in cement mortar (1:4) including necessary form work complete all as specified and directed
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in benching for manholes, bands, coping bed plate and for embedding rungs etc with slightly chamfered or rouned angles, including necessary form work, if any and finishing exposed surface even and smooth without using extra cement complete all as specified and directed Details of Qty Sewage Line-27.00 Cum Area Drainage-11.00 Cum
Material and labour for 15mm thick cement plaster in CM (1:3) admixed with integral water proofing compound on wall as well as on sunken floor finished even and smooth using extra cement complete all as specified. Note WPC shall be measured separately
Supply only Integral waterproofing compound complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required of any internal dia of pipe complete all as specified and directed
Supply and fixing rolled mild steel joist, channel, angle or tee sections as in manholes frame etc including cutting to required size and shape welding etc duly painted with two coats of black bitumen paint over one coat of red oxide primer fixed independently, with connecting plates, etc. conforming to Gde Fe 410-W (Gde-E-250) quality 'A' complete all as specified and directed
Mild steel work confroming to E-165 Grade Fe-290 as in steps, rungs band, handles and similar small articles fixed independent made to shape and duly tared and sanded complete all as specified and directed
Material and labour for preparation of new or previously untreated steel surfaces of any description, not exceeding 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed Details of Qty Sewage Line-784.38 Cum Lift-17.94 Cum Central AC Plant-17.43 Cum
Removing excavated soil material to a distance exc. 1.50 km but n.exc. 5 km and depositing where directed at a level 1.5m above the starting point complete all as specified and directed
Cleaning of manhole having depth upto 1.5m and removing sludge cum etc to a distance not exceeding 250m and burring the same underground by digging pit of suitable size in low lying are away from habitant area and covering same with earth including removal of surplus soil to distance not exceeding 250m complete all as specified and directed
Cleaning of sewage line by mechanical means/ jetting having depth up 1.5m and removing sludge cum etc to a distance not exceeding 250m and burring the same underground by digging pit of suitable size in low lying area away from habitant area and covering same with earth complete all as specified and directed
Cleaning of sewage line by mechanical means/ jetting having depth exc 1.5m but not exc 3.0m and removing sludge cum etc to a distance not exceeding 250m and burring the same underground by digging pit of suitable size in low lying area away from habitant area and covering same with earth complete all as specified and directed
Material and labour for chequered cement concrete tiles 25cm x 25cm x 25mm thick, set, jointed and pointed with grey cement & pigment over and incluiding 15mm screed bed in cement mortar (1:6) complete all as specified and directed
Material and labour for 75mm thick cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed
Material and labour for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 25mm thick sand cushioning complete all as specified and directed
AREA DRAINAGE SUPPLY WORKS
Material and labour for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and directed
Demolition of reinforcement cement concrete in ground floor and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in landing, cover slabs (for manhole etc.) setting in cement mortar (1:4) complete with joint to match all as specified and directed
Material and labour for brick work with old size sub class ‘B’ bricks, laid on edge as side walls of brick drains in slope, bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and directed
All as per srl item No. 5.04 here-in-before but except brick
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed
Add or deduct for each 25mm girth or part thereof over or under 30cm complete all as specified and directed
Cleaning to drains by taking out brick bat, pebbles, silts, muds, clay, sludge, grubbing up bushes etc. from the bottom of drain and culvert bed etc. and removing the same to outside the defence land in any vehicles, complete all as specified and directed
ELECTRIC SUPPLY WORKS
Taking down carefully existing point wiring of any type (ie on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point sunken boxes, regulators, cover plate/ sheet with fitting and fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawal plug, screw etc including removing materials from site for taking credit for unservceable item and re-fixing the serviceable items as per schedule and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through in and including non metallic rigid PVC concealed conduit medium grade 20mm dia (Minimum) or higher size as specified and cutting chasing on wall complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and modular metal flush mounting box with white cover plate with frame, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed for one light point/exhaust fan/bell controlled by one switch SP one way.
All as per srl item No. 6.02 here-in-before but for one light point controlled by one 1-way switch, with cables 1.5 sqmm size for corridoor/ stair/ ramp (upto 15m length) lighting in existing conduit complete all as specified
All as per srl item No. 6.02 here-in-before but for one light point controlled by two 2-way switches, with cables 1.5 sqmm size complete all as specified
All as per srl item No. 6.02 here-in-before but for one socket outlet 5 Amps on independent board complete all as specified
All as per srl item No. 6.02 here-in-before but for one socket outlet 5 Amps on same board controlled with other switch complete all as specified
All as per srl item No. 6.02 here-in-before but with 2.5 Sqmm (nominal area) FRLS cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed.
Supply and fixing white modular switch 6 Amp, one way one module complete all as specified and directed
Supply and fixing white modular switch 6 Amp, two way one module complete all as specified and directed
Supply and fixing white modular switch 16 Amp, one way one module complete all as specified and directed
Supply and fixing white modular bell push switch 6 Amp, one module complete all as specified and directed
Supply and fixing white modular socket 6 Amp, 2in1 socket with shutter combined two module complete all as specified and directed
Supply and fixing white modular socket 6/16 Amp, twin socket combined two module complete all as specified and directed
Supply and fixing white modular fan regulator, step type, 5 steps, two module complete all as specified and directed
Supply and fixing in replacement for ceiling rose surface type bakelite 65 x 50 mm three terminal complete all as specified.
Supply and fixing in replacement Bell electric AC (Ding Dong) 240 volt SP complete all as specified
Material and labour in repairs Submain wiring with PVC insulated unsheathed cable copper conductor FRLS two single core 2.50 Sqmm drawn through and including PVC rigid non metallic concealed conduit medium grade, ISI marked, size not less than 20mm with all fitings including earth continuity FRLS copper conductor 2.5 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain complete all as specified.
Material and labour in repairs Submain wiring with PVC insulated unsheathed cable copper conductor FRLS two single core 4.0 Sqmm drawn through and including PVC rigid non metallic concealed conduit medium grade, ISI marked, size not less than 25mm with all fitings including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified including taking down existing unserviceable/burnt submain.
Material and labour in repairs Submain wiring with PVC insulated unsheathed cable copper conductor FRLS two single core 6.0 Sqmm drawn through and including PVC rigid non metallic concealed conduit medium grade, ISI marked, size not less than 25mm with all fitings including earth continuity FRLS copper conductor 6.0 Sqmm PVC insulated with green insulation complete all as specified including taking down existing unserviceable/burnt submain. Notes for Srl item No. 6.17 to 6.19 : (i) Two run of cable & one run of cable alongwith PVC conduit combined together will be measured as on unit. (ii) The quoted rate includes making good disturbed surface of walls, floors to match with existing surface including any type of civil work.
Material and labour in repairs Submain wiring with PVC insulated unsheathed cable copper conductor FRLS four single core 10 Sqmm drawn through and including PVC rigid non metallic concealed conduit medium grade, ISI marked, size not less than 32mm with all fitings including earth continuity FRLS two single core copper conductor 10 Sqmm PVC insulated with green insulation complete all as specified including taking down existing unserviceable/burnt submain.
Material and labour in repairs Submain wiring with PVC insulated unsheathed cable copper conductor FRLS four single core 16 Sqmm drawn through and including PVC rigid non metallic concealed conduit medium grade, ISI marked, size not less than 32mm with all fitings including earth continuity FRLS two single core copper conductor 16 Sqmm PVC insulated with green insulation complete all as specified including taking down existing unserviceable/burnt submain. Notes for Srl item No. 6.20 & 6.21 : (i) Four run of cable & two run of cable alongwith PVC conduit combined together will be measured as on unit. (ii) The quoted rate includes making good disturbed surface of walls, floors to match with existing surface including any type of civil work.
Supply and fixing in reapirs/replacement PVC rigid non metallic conduit medium grade ISI mark 25mm dia concealed including cutting chases making good in cement mortar 1:3 finishing, and incl conduit accessories such as tee, elbow ,bend junction box complete for drawing telephone cable/ TV cable/ Camera cable/ Pvc copper wires all as specified.
Supply and fixing distribution board, vertical type, double door with IP-43 IK -09 Protection suitable for MCCB TPN as incommer and MCB SP as outgoing 415 volts 3 phase 50 C/s 4 way , complete with copper bus bar and neutral link complete with and including one MCCB TPN 415 volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall suface all as specified and directed.
Supply and fixing in reapirs/replacement Sheet metal enclosure for DBs when MCBs to be used, SPN 8 ways 240 V, with copper bus bar, double door, epoxy/ powder coated inside and outside complete all as specified.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 16 amp 240 V 10 KA and metal top plug complete all as specified and as directed.
Material and labour in replacement MCB SP 6 Amps to 32 Amps, 240V with rupturing capacity 10 KA, B Curve complete all as specified
Material and labour in replacement MCB SPN 6 to 32 Amps, 240V with rupturing capacity 10 KA, B Curve complete all as specified
Material and labour in replacement MCB TP 32 Amps, 415V with rupturing capacity 10 KA, C Curve complete all as specified
Supply and fixing in replacement retrofit type LED tube light fitting complete with CRCA box type frame 20 watt and including suitable polycarbonate LED tube rod 20 watt or next higher capacity complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 34/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, LED strip suitable for roof grid ceiling/POP ceiling with fixing clamp if required, connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 34/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, LED strip suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED light fitting 1x9W/10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Supply and fixing Unplasticised PVC pipes of size 25mm dia, pressure rating 10kgf/cm2 fixed complete to walls, ceilings or in floors including all fittings as per site requirement for split AC water drain complete all as specified and directed.
Supply and fixing Unplasticised PVC pipes of size 32mm dia, pressure rating 10kgf/cm2 fixed complete to walls, ceilings or in floors including all fittings with necessary fixing arrangement as per site requirement for split AC water drain complete all as specified and directed.
Supply and fixing flexible nylon braided PVC hose pipes of size 32mm dia with adjustable hose clip clamps and fixed complete to walls, ceilings or in floors for splict AC water drain complete all as specified and directed.
Supply and fixing Unplasticised PVC pipes of size 40 mm dia, pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors including all fittings as per site requirement for split AC water drain complete all as specified and directed.
Taking down split type Air Conditioner 1.5/2 Ton capacity complete & refixing it after building repair work including minor repair work and general servicing of indoor and outdoor unit and make it functional and testing complete all as specified and directed.
Refixing of serviceable light fitting any type retrieved from srl item No.1 and make electric connections for functional all as specified and directed.
Taking down ceiling Fan/exhaust fan of any sweep or make, and refixing it after completion of building repair work complete all as directed.
Painting of ceiling fans/exhaust fans complete (as per previous colour), with syntetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc including replacement of flexible wire, rubber reel, nut, bolts testing on running position complete.
Supply and fixing exhaust fan, metallic body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers ,made out of GI sheet in outside of wall including making opening in wall and making good to disturbed surface and connecting up complete all as specified and directed.
Supply and fixing exhaust fan, metallic body AC single Phase. 230V of size 380m sweep with, blades, and frame and louvers ,made out of GI sheet in outside of wall including making opening in wall and making good to disturbed surface and connecting up complete all as specified and directed.
Supply and fixing ceiling fan complete with blades, down rods, and accessories, 230 V, 1400 mm sweep. with service value 6.00 BEE. Five star rated with brushless direct current motor complete all as specified and directed.
Material and labour for earthing complete with & including galvanized iron earth plate of size 600 x 600 x 6 mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire 4mm dia connected permanently and riveted to earth plate by means of nuts, bolts , check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No. 3 of MES SSR Part- I (2009) and connected to panel board, all as specified and testing on completion including provn of earth wire protected by 15 mm dia light grade GI pipe upto 7.5 meter from electrode to earth terminal point Feeder Pillar box including provn of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate GI light grade watering pipe of 20mm dia with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth chamber, 50 mm thick RCC cover using cementconcrete 1:2:4 type B-0 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified & shown on drawings & directed.
Taking down carefully existing serviceable surface mounted submain wiring by taking out copper wires of any size upto 6 sqmm alongwith PVC conduit with fitings and refixing the conduit as concealed conduit including cutting chases in walls, plastering the surface with any type of civil work required and drawing existing serviceable submain wiring, replacement of conduit and conduit fittings if required for refixing all as specified and directed.
Taking down carefully existing serviceable TPN/ SPN DBs any type surface mounted alongwith MCBs including opening/ disconnecting wire connection and re-fixing the DB in as concealed including cutting chases in walls and making good disturbed surfaces with any kind of civil work complete wire all as specified and directed
Material and labour in repairs for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop Earthing etc. as required 4mm dia galvanised iron complete wire all as specified and directed.
Material and labour Tubes, 'light grade' 15 mm bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for GI earth wire protection complete wire all as specified and directed.
AIR CONDITIONING SUPPLY WORKS
Supply and install hi wall split units indoor/ outdoor 3 star rated complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary, 100% copper coil of capacity 2 TR complete all as specified and directed. Notes : i) The quoted rate include provision of copper piping and wiring from indoor unit to outdoor unit upto 5 mtr and outdoor mounting bracket. ii) Installation should be done through OEM/OEM authorised service provider only.
Supply and fixing wall mounted electronic Voltage stabilizer, for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% with Digital display to show input and output voltage of capacity 15 Ampere complete all as specified and directed.
Taking down old unserviceable split type air conditioner indoor and outdoor unit including removing copper piping, voltage stabilizer and electric connections all as specified and directed.
PATIENT CALL BELL SYSTEM SUPPLY WORKS
Supply and fixing Microprocesser based Wireless multiservice Display system of patient call bell system with the following specifications:- i) Display: Capacity 50 beds, 7 Segment LED Display (Max. 2 Digits) One Room, Receiving 3 LEDs, Indicators for Nurse Call, Code Blue and housekeeping ii) The system should also display bed Nos if more than one patient call is received. iii) Luminous Intensity Matching Ratio: 2:1 iv) Frequency Range: 433 MHz Confirming to ISO/IEC 18000-7:2014 v) Transmitter Operating Voltage: +5V. vi) Transmitter Operating current: 9mA to 40mA. vii) Transmission Distance: 3 meters to 100 meters (maximum) viii) Modulating Technique: ASK (Amplitude shift keying) ix) RFAF: Supports ISM 433.05MHz to 434.79MHz use. Low Insertion Loss, Low Pass-Band Ripple, High Ultimate Attenuation x) Filters Design: To protect the LNA from noisy and out of band emissions originated from nearby transmitters. xi) Protection: Against Non-Linear Distortion xii) Indication on patient calling: Audio Visual indication with particular bed no. is displayed with audio indication address in human voice address.
xiii) For More than 2 patients calling simultaneously: Continuous Audio address - Attention Patient Calling. xiv) Active Call Indication: Total Nos. of active calls on One Inch Seven Segment Display. Bed no. configuration & Removal: Plug and Play at the spot xv) Input Power Supply: AC 230 V 2 Amps 50 Hz Power Supply through SMPS based AC-DC Adaptor. xvi) Operating Voltage: 5VDC/12 VDC Operating Current: 200 mA xvii) Operating Temp: 0oC - 50oC xviii) Operating Humidity: 10% to 90% without congealment xix) Speaker (Full duplex), Impedance: 8Ω±15% xx) Max Output Power: 0.5W, Distortion Rate: 5%MAX xxi) Max dB: 89 ±3dB
Supply and fixing Micrprocesser based Wireless multiservice Bed Unit for three service call with built in RFAFwith DC 12 v battery and mounting plate including fixing accessories with the following specifications:- Bed Unit i) Operating Temp 0°C - 50°C (32°F - 122°F) ii) Operating Humidity 10% - 90% without congealment Power Consumption iii) Operating Voltage: DC 12V (Miniature Alkaline 12V DC Battery operated) iv) Operating Current: 45mA, v) Frequency Range: 433 MHz Confirming to ISO/IEC 18000-7:2014 vi) Transmitter Operating Voltage: +5V. vii) Transmitter Operating current: 9mA to 40mA. viii) Transmission Distance: 3 meters to 100 meters (maximum) ix) Modulating Technique: ASK (Amplitude shift keying) x) RFAF: Supports ISM 433.05MHz to 434.79MHz use. Low Insertion Loss, Low Pass-Band Ripple, High Ultimate Attenuation xi) Filters Design: To protect the LNA from noisy and out of band emissions originated from nearby transmitters. xii) Protection: Against Non-Linear Distortion Hand set i) Two Meter Wired handset for Three Service Calling (Nurse Call, Code Blue and housekeeping), ii) Reset Facility Multi Service including 3 Service for Nurse Calling, Code blue and Housekeeping, iii) Operating Temp 0°C - 50°C (32°F - 122°F), iv) Operating Humidity 10% - 90% without congealment v) Operating Current: Standby < 10mA, Working status< 45mA Make for item No 8.01 & 8.02 : Shreya Electronics by Kartik Enginers, Delhi or equivalent approved by CWE Notes for item No 8.01 & 8.02 : The quoted rate includes the rate of necessary configuration/ pairing as required at site and as directed by Engineer-in-Charge. The quoted rate includes the cost of any repeater/ signal booster required at site for smooth functioning of system.
OXYGEN GAS SUPPLY WORKS
Supply and fixing Cylinder Oxygen Manifold for 2 cylinder emergency to withstand a pressure of 140kg/sqcm and above along with high pressure copper annealed tail pipe with end Brass adapter suitable for oxygen Cylinder and Manifold top frame comprising of high pressure copper pipes of size 12mm I.D end Brass adapter suitable for oxygen Cylinder and Manifold top frame comprising of high pressure copper pipes of size 12 mm I.D×1.5mm wall thick, with high pressure brass fitting made of high tensile brass and connections through non-return valVes high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.d×1.5mm wall thickness the design of middle and bottom frames would be provide to fit both round and flat bottom cylinder safely. The manifold would be tested (hydraulically) at 3500psig.
Supply, installation, commissioning and testing of wall mounted digital area gas alarm panel two lines (oxygen and vacuum), with audio-visual alarms for each gas, running on electricity 220V. The gas alarm comprising of following :- (a) Two gas alarm (b) Individual gas status LED indicator (c) Auto alarm for low and high pressure (d) Display of line pressure for all the services with factory calibrated pressure sensors (e) Alarm test/ check/ mute facility (f) Nut and nipples are to be provided for connection with pneumatic supply line (g) Low voltage internal operation with ouput power supply of 220V AC (h) The model should be IEC 60601-1-2 compliance (j) It should be complaint to HTM 02-01/ NFPA 99 C/ EN and ISO 7396-1:2007 standards (k) The product should be BIS/ CE certified. MAKE FOR SRL ITEM NO. 9.01 & 9.02 : UNISSI India Pvt Ltd, New Delhi/ NSP Hospitech India Pvt ltd, New Delhi/ MPS (MPS Project, New Delhi/ Aktiv (Aktiv Technologies, Faridabad).
Supply, laying, commissioning and testing for medical grade copper pipes solid drawn of 12mm OD, 1.0 mm thick, seamless, deoxidized, nonarsenical, half hard, tempered and degreased materials conforming to BS:EN:13348 : 2016 laying with walls with brackets etc with all copper fittings such as tees, bends, elbows, functions unions etc including soldering, brazing copper welding etc suitable for working pressure of 17 bar conforming to BS EN1254 with specially made for brazed socket type connections pipe duly painted with colour acccording to colour i.e. yellow for oxygen line & blue for suction line and as mentioned below :- (a) Installation of piping should be carried out as per standard medical practice with atmost cleanliness (b) Only pipes, fittings and valves which degreased as per approved medical standards should be used (c) Pipe fixing metalic/PVC clamps suitable dia should be provided in every meter (d) Adequate supports shall be provided while laying pipelines to ensure that the pipes do not sag (e) Minimum copper content 99.90% Make : Mexflow/Mandev/Metalalloys Notes : (a) All brazing copper to copper joints shall be done by using brazing rod (5% silver copper phosphorous alloy) and copper to brass or gun metal shall be jointed by using brazing rod AG 203 (43% silver copper zinc brazing alloy. (b) Inert gas welding technique should be used by oxygen free Nitrogen gas inside copper pipes while brazing to avoid carbon deposition. (c) After erection, the pipes shall be flushed and then pressure testing shall be carried out. (d) All exposed pipes should be painted with two coats of synthetic enamel paint and colour codification should be as per IS-2379 of 1963. (e) Copper pipe passing through wall/ floors should be pass through suitable sleeves.
All as per Srl item No. 9.03 here-in-before but 15mm OD, 1.0mm thick.
All as per Srl item No. 9.03 here-in-before but 22mm OD, 0.9mm thick.
All as per Srl item No. 9.03 here-in-before but 28mm OD, 0.9mm thick.
Supply and fixing Zonal Valve Box, suitable for two lines (Oxygen, Vacuum) confirming to EN ISO 5211 : 2001, MS powder coated & lockable with 3mm thick front glass mounting easily visible and including pressure guage of suitable capacity, brass body quarter turn ball valves of size 22mm dia using for opening & closing position, valve box door cannot be closed during valve closing position. In case of emergency the door can be glass break opened or by un-locking using the key complete all as specified and directed. Make : UNISSI India Pvt Ltd, New Delhi/ NSP Hospitech India Pvt ltd, New Delhi/ MPS (MPS Project, New Delhi/ Aktiv (Aktiv Technologies, Faridabad).
Supply, installation, testing and commissioning of brass isolation valves quarter turn type as per CE certified/HTM-2022/02-01/DIN/ISO/BS EN 1057 or ball valves as per BS 1057, rated at 400 psig, as well as full vacuum (29.9" Hg). Valves go from full ON to full OFF by turnig the vinyl-gripped valve handles 90 degree locking type including handles complete all as specified and directed and suitable for 12mm sizes of copper pipes:- Make : RN/JSI/Uttam
All as per Srl item No. 9.08 here-in-before but 15mm size
All as per Srl item No. 9.08 here-in-before but 22mm size
All as per Srl item No. 9.08 here-in-before but 28mm size
Supply installation, testing and commissioning of Oxygen outlet point terminated properly Double locking Front Loaded which have a parking facility (Parkodex) which also avoids inter changing of out let and Keys (Gas specific probes) operating pressure rating 4 Bar as specified below :- a) Outlets shall be fitted with a 165 mm length Copper inlet pipe stub which is silver brazed to the outlet body. Body shall be of one piece brass construction. For positive pressure gas services, the outlet shall be equipped with a primary and secondary check valve and the secondary check valve shall have break safe mechanism and also comply to BS EN-9170 pressure test standards and rated at minimum 200 psi in the event the primary check valve is removed for maintenance. b) The outlet assembly should have separate colour coding for each services and will accept only corresponding gas specific adaptors. All outlets shall be cleaned and de-greased for medical gas service, factory assembled and tested. The medical gas outlets should be of quick connecting and wall mounted modular type.
Supply installation, testing and commissioning of vacuum outlet point terminated properly Double locking Front Loaded which have a parking facility which also avoids inter changing of outlet and Keys (Gas specific probes) operating pressure rating 4 Bar as specified below :- a) Outlets shall be fitted with a 165 mm length Copper inlet pipe stub which is silver brazed to the outlet body. Body shall be of one piece brass construction. For positive pressure gas services, the outlet shall be equipped with a primary and secondary check valve and the secondary check valve shall have break safe mechanism and also comply to BS EN-9170 pressure test standards and rated at minimum 200 psi in the event the primary check valve is removed for maintenance. b) The outlet assembly should have separate colour coding for each service and will accept only corresponding gas specific adaptors. All outlets shall be cleaned and de-greased for medical gas service, factory assembled and tested. The medical gas outlets should be of quick connecting and wall mounted modular type.
Supply installation, testing and commissioning of oxygen Back Pressure Compensated flow meter with control range of 0 – 15 lpm (calibration within +/- 10% ) with 250 ml humidifier bottle made of unbreakable polycarbonate material and autoclavable at 121 degree Centigrade temperature.The flow meter conforming to BS EN 15002 : 2008 shall be strict precision, durability standard and body shall be made of brass chrome plated materials.The flow tube and shroud components shall be made of clear, impact resistant polycarbonate.Flow Tube shall have large and expanded 0 – 5 lpm range for improved readability at low flows with Inlet filter to prevent entry of foreign particles.
Suply, installation testing and commissiong of Ward suction unit or Ward Vacuum Unit with above 600 ml suction jar coforming to BS EN ISO 10079 - 3 : 2009 as per specifications mentioned below:- (a) The vacuum regulator should have a vacuum gauge with analog display.The scale should be in mbar or mmhg. (b) 1 No of Suction Regulator and 1 No of 600 ml polysulfone /polycarbonate collection jar, autoclavable at 121º C, unbreakable, fitted with an anti-overflow safety/ reverse flow prevention device and equipped with a plastic antibacterial filter and should be totally transparent, to ensure perfect sucked liquid visibility. (c) Should have vacuum levels: 0-760 mm of Hg and Should have vacuum gauge fitted with a protective bumper device. (d) Should have on/off knob allowing for the quick restoration of a readjusted vacuum level. (e) Must have central adjustment knob with a color coded for 0 to 760 mm of Hg.
Supply , install, testing and commissioning of Bed Head Panels horizontal, Powder coated, It should have the following features:- Minimum length 1200 mm, width 250mm, 2mm thick. Efficient, safe & Robust design in extruded aluminium section. Smooth curved surfaces, with acceptable colour choice Should have an integrated rail system to mount accessories Segregation of services i.e. low voltage supplies, high voltage supplies, and medical gases should be maintained throughout. Facility as per under :- (a) Ward Vacuum unit clip - 01 Nos. (b) Modular Socket 15 Amp with switch -02 Nos. (c) Modular Socket 5 Amp with switch -02 Nos. . (d) Fixing arrangement for Oxygen Outlet - 01 Nos (e) Fixing arrangement for Vacuum Outlet - 01 Nos Note : 1. The quoted rate includes necessary mounting arrangements to fix the panel in wall/pillar 2. Oxygen and Vacuum outlet shall be measured and paid seprately under respective item.
Supply and fixing wall mount Medical Monitor stand, aluminium alloy body, suitable for monitor size 12" - 22", max load 20 KG complete all as specified and directed. (CERTIFIED:-18-04-57),
Supply and fixing for I V stand telescopic pole tubular 16 gauge type 304 SS, height and arms as per standard medical practice all as specified and directed by Engr-in-Charge. (CERTIFIED:-18-04-57). MAKE FOR SRL ITEM NO. 9.12 to 9.18 : UNISSI India Pvt Ltd, New Delhi/ NSP Hospitech India Pvt ltd, New Delhi/ MPS (MPS Project, New Delhi/ Aktiv (Aktiv Technologies, Faridabad).
Taking down carefully existing bed headed panel 1200mm length from wall for re-fixing after civil repair including disconnecting electrical wires, medical gas pipe line with any type of brazing/ cutting works required and fixing dead plug in pipe line and deposit to MES store for re-use complete all as specified and directed
Fixing only bed headed panel 1200mm size retrieved from taking down above including collecting from MES store yard, connecting power supply and medical gas pipe line including cleaning, brazing work and make it functional all as specified and directed
Material and labour for painting of medical gas pipe line of size 12/15mm as per existing colour by one coat of synthetic enamel paint all as specified and directed
Material and labour for painting of medical gas pipe line of size 22/28mm as per existing colour by one coat of synthetic enamel paint all as specified and directed
LIFT WORKS
Material and labour for 12mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall), 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over one coat of primer complete all as specified and directed
Material and labour for preparation of newly plastered surfaces of ceilings and applying two coats of oil emulsion distemper over one coat of primer complete all as specified and directed
Material and labour for preparation old decirated/ treated surfaces of walls including removing existing treatment by rubbing, scrapping, washing and applying two coats of oil emulsion distemper over one coat of primer complete all as specified and directed
Material and labour for preparation old decirated/ treated surfaces of ceilings including removing existing treatment by rubbing, scrapping, washing and applying two coats of oil emulsion distemper over one coat of primer complete all as specified and directed
Design, Supply, installation, testing and commissionning of 20 passengers cum stretcher lift, Gearless lifts machine room less (MRL) to serve G+3 upper floors with AC variable voltage & variable frequency (VVVF) drive or variable frequency (VF) drive as per OEM recommendation drive complete with all standard accessories, simplex full collective controlled operation, Telescopic side opening stainless steel doors with power drive, Automatic Rescue device system and 3 way intercom system & infra red curtain sensor, with items all as specified herein under:- (i) Type and capacity of Lift : Traction type, 20 Passengers Cum stretcher Lift (1360 kgs) (ii) Speed: 1.0 m/sec (iii) Type of Drive : AC variable voltage & variable frequency (VVVF) drive or variable frequency (VF) drive as per OEM recommendation (iv) Machine room Less type (v) Travel - 12.0 Mtrs (Approx) or as per actual site measurement (vi) Serving : Ground floor to 3rd Floor ( Floor designations will be 0,1,2,3) (vii) No of stops : 4 (viii) Power supply: 415 Volts, 3 phase, AC, 50 Hz (ix) Existing lift shaft dimension-2140mm width and 3000mm depth (approx) for one lift and 2600mm width and 3300mm depth (aprrox) for second lift (x) Min Car size (inside): 1300mm wide x 2400 deep x 2200 mm high (xi) Door dimensions : 1200mm wide x 2000mm high (min.) (xii) Pit depth : 1500mm approx(min) (xiii) Over Head height : 4500mm approx (xiv) Car enclosure: Single entrance Car Car panels : AISI 441 Stainless steel hairline finish panels (all sides) with stainless steel hairline finish hand rail on back/ rear wall Car ceiling: AISI 441 Stainless Steel hairline finish ceiling with axial fan-02 Nos (min) or as per OEM recommendation. Car Flooring : Aluminium Chequered plate min 5mm thick, Car Doors : Telescopic side opening auto power doors in AISI 441 stainless steel hairline finish. The direction of door opening should be as per space availability at site.
Skirting material : Stainless steel hairline Car illumination : round LED lights - 06 Nos (xv) No of entrance : Front opening in all landings (xvi) Door safety : Full height infra red curtain sensor (xvii) Landing Door/ Entrance: Telescopic side opening auto power doors in AISI 441 stainless steel hairline finish with 2 Hr fire rating for landing at all floors (xviii) Control :Simplex Full collective (xix) Indicators: Car & landings: Direction and position indicator (xx) Half Height Car operating panel : Silver Brushed Stainless steel AISI 304 flush type with DOT Matrix display with surface mounted Braille buttons (xxi) Landing operating panel: Silver Brushed Stainless steel AISI 304 Flush mounted Simplex with DOT Matrix display with surface mounted Braille buttons (xxii) Any type of structural steel reqd in shaft, bearing plate, necessarey buffer, hanging hook and support channel (xxiii) Reqd trailing cable, Suspension Traction media, belt/ steel wire rope as per OEM recommendations etc FEATURES : (a) Direction and position indicator in COP & LOP.
(b) Emergency Alarm. (c) Three way intercom with hand free option for car (d) Attendant key switch for COP (e) Fireman switch at main lobby (f) Emergency light with rechargeable battery and connected equipment for charging (g) Adjustable guide shoes (h) Lift announcer (i) Accurate levelling, automatic closed door (j) Load weighing device with overload warning (k) Automatic phase sequence corrector & single phasing protection, under voltage and over voltage protection (l) Manual rescue Operation (m) Automatic (Emergency) rescue device/automatic landing device with audio announcer to be operated with maintenance free batteries for safe landing as specified. (n) Other Equipments, accessories, safety devices reqd as per recommendation of OEM (o) Auto On/Off light/fan mode Notes : i) The Lifts shall be installed by the original equipment manufacturer only. ii) The Lifts shall be tested by IEM after installation in the attendance of manufacturer. iii) The designing of the lift shall be as per existing lift shaft. The lift shall be installed as replacement in existing lift shaft. iv) The scope of work also covers the civil work comprising cutting of holes/ opening and making good the surfaces, provn of counter weight, guide rails and bracket, terminals buffers supports and sill angle, plates, load beam, MS channel, over speed governor and any other items required for successful completion of lift with respect to safety required by the OEM, will be carried out by the contractor without any extra cost. (v) The provision of suitable steel structure/platform for installation of lifts equipment is part of lift items and nothing extra shall be paid. (vi) If any clearance is required to seek from state Govt i.e. from lift inspector or electrical safety department or fire safety department, which will be contractor's responsibility & any expenditure on this account shall deemed to be included in the quoted unit rates. (vii) The quoted rate shall include two year comprehensive maintenance of lifts by OEM.
(viii) The design details of lift shall be submitted by the contractor once the same is approved by the CWE. Make of Lifts : KONE/ SCHINDLER/ OTIS/ HITACHI/ JOHNSON
Design, Supply, installation, testing and commissionning of 20 passengers cum stretcher lift, Gearless lifts machine room less (MRL) to serve G+1 upper floors with AC variable voltage & variable frequency (VVVF) drive or variable frequency (VF) drive as per OEM recommendation drive complete with all standard accessories, simplex full collective controlled operation, Telescopic side opening stainless steel doors with power drive, Automatic Rescue device system and 3 way intercom system & infra red curtain sensor, with items all as specified herein under:- (i) Type and capacity of Lift : Traction type, 20 Passengers Cum stretcher Lift (1360 kgs) (ii) Speed: 1.0 m/sec (iii) Type of Drive : AC variable voltage & variable frequency (VVVF) drive or variable frequency (VF) drive as per OEM recommendation (iv) Machine room Less type (v) Travel - 4.0 Mtrs (Approx) or as per actual site measurement (vi) Serving : Ground floor to 1st Floor ( Floor designations will be 0 & 1) (vii) No of stops : 2
(viii) Power supply: 415 Volts, 3 phase, AC, 50 Hz (ix) Existing lift shaft dimensions : 2300mm width and 3200mm depth (approx) (x) Min Car size (inside): 1300mm wide x 2400 deep x 2200 mm high (xi) Door dimensions : 1200mm wide x 2000mm high (min.) (xii) Pit depth : 1500mm approx(min) (xiii) Over Head height : 4500mm approx (xiv) Car enclosure: Single entrance Car Car panels : AISI 441 Stainless steel hairline finish panels (all sides) with stainless steel hairline finish hand rail on back/ rear wall Car ceiling: AISI 441 Stainless Steel hairline finish ceiling with axial fan-02 Nos (min) of as per OEM recommendatin. Car Flooring : Aluminium Chequered plate min 5mm thick. Car Doors : Telescopic side opening auto power doors in AISI 441 stainless steel hairline finish. The direction of door opening should be as per space availability at site. Skirting material : Stainless steel hairline Car illumination : round LED lights - 06 Nos (xv) No of entrance : Front opening in all landings (xvi) Door safety : Full height infra red curtain sensor (xvii) Landing Door/ Entrance: Telescopic side opening auto power doors in AISI 441 stainless steel hairline finish with 2 Hr fire rating for landing at all floors (xviii) Control :Simplex Full collective (xix) Indicators: Car & landings: Direction and position indicator (xx) Half Height Car operating panel : Silver Brushed Stainless steel AISI 304 flush type with DOT Matrix display with surface mounted Braille buttons (xxi) Landing operating panel: Silver Brushed Stainless steel AISI 304 Flush mounted Simplex with DOT Matrix display with surface mounted Braille buttons (xxii) Any type of structural steel reqd in shaft, bearing plate, necessarey buffer, hanging hook and support channel (xxiii) Reqd trailing cable, Suspension Traction media i.e. belt/ steel wire rope as per OEM recommendations etc.
FEATURES : (a) Direction and position indicator in COP & LOP . (b) Emergency Alarm. (c) Three way intercom with hand free option for car (d) Attendant key switch for COP (e) Fireman switch at main lobby (f) Emergency light with rechargeable battery and connected equipment for charging (g) Adjustable guide shoes (h) Lift announcer (i) Accurate levelling, automatic closed door (j) Load weighing device with overload warning (k) Automatic phase sequence corrector & single phasing protection, under voltage and over voltage protection (l) Manual rescue Operation (m) Automatic (Emergency) rescue device/automatic landing device with audio announcer to be operated with maintenance free batteries for safe landing as specified. (n) Other Equipments, accessories, safety devices reqd as per recommendation of OEM
(o) Auto On/Off light/fan mode. Notes : i) The Lifts shall be installed by the original equipments manufacturer only. ii) The Lifts shall be tested by IEM after installation in the attendance of manufacturer. iii) The designing of the lift shall be as per existing lift shaft. The lift shall be installed as replacement in existing lift shaft. iv) The scope of work also covers the civil work comprising cutting of holes/ opening and making good the surfaces, provn of counter weight, guide rails and bracket , terminals buffers supports and cill angle, plates, load beam, MS channel, over speed governor and any other items required for successful completion of lift with respect to safety required by the OEM, will be carried out by the contractor without any extra cost. (v) The provision of suitable steel structure/platform for installation of lifts equipment is part of lift items and nothing extra shall be paid. (vi) If any clearance is required to seek from state Govt i.e. from lift inspector or electrical safety department or fire safety department, which will be contractor's responsibility & any expenditure on this account shall deemed to be included in the quoted unit rates. (vii) The quoted rate shall include two year comprehensive maintenance of lifts by OEM. (viii) The design details of lift shall be submitted by the contractor once the same is approved by the CWE. Make of Lifts : KONE/ SCHINDLER/ OTIS/ HITACHI/ JOHNSON
Design, Supply, installation, testing and commissionning of 10 passengers lift, Gearless lifts machine room less (MRL) to serve G+3 upper floors with AC variable voltage & variable frequency (VVVF) drive or variable frequency (VF) drive as per OEM recommendation drive complete with all standard accessories, simplex full collective controlled operation, centre opening stainless steel doors with power drive, Automatic Rescue device system and 3 way intercom system & infra red curtain sensor, with items all as specified herein under:- (i) Type and capacity of Lift : Traction type, 10 Passengers Lift (680 kgs) (ii) Speed: 1.0 m/sec (iii) Type of Drive : AC variable voltage & variable frequency (VVVF) drive or variable frequency (VF) drive as per OEM recommendation (iv) Machine room Less type (v) Travel - 12.0 Mtrs (Approx) or as per actual site measurement (vi) Serving : Ground floor to 3rd Floor ( Floor designations will be 0,1,2,3) (vii) No of stops : 4 (viii) Power supply: 415 Volts, 3 phase, AC, 50 Hz (ix) Shaft dimensions : 2280mm width and 3000mm depth (x) Min Car size (inside): 1200mm wide x 1400 deep x 2200 mm high (xi) Door dimensions : 800mm wide x 2000mm high (min.) (xii) Pit depth : 1500mm approx(min) (xiii) Over Head height : 4500mm approx (xiv) Car enclosure: Single entrance Car Car panels : AISI 441 Stainless steel hairline finish panels (all sides) with stainless steel hairline finish hand rail on back/ rear wall Car ceiling: AISI 441 Stainless Steel hairline finish ceiling with axial fan, Car Flooring : Aluminium Chequered plate min 5mm thick, Car Doors : Centre opening auto power doors in AISI 441 stainless steel hairline finish. The direction of door opening should be as per space availability at site. Skirting material : Stainless steel hairline Car illumination : round LED lights - 04 No
(xv) No of entrance : Front opening in all landings (xvi) Door safety : Full height infra red curtain sensor (xvii) Landing Door/ Entrance: Telescopic side opening auto power doors in AISI 441 stainless steel hairline finish with 2 Hr fire rating for landing at all floors (xviii) Control :Simplex Full collective (xix) Indicators: Car & landings: Direction and position indicator (xx) Half Height Car operating panel : Silver Brushed Stainless steel AISI 304 flush type with DOT Matrix display with surface mounted Braille buttons (xxi) Landing operating panel: Silver Brushed Stainless steel AISI 304 Flush mounted Simplex with DOT Matrix display with surface mounted Braille buttons (xxii) Any type of structural steel reqd in shaft, bearing plate, necessarey buffer, hanging hook and support channel (xxiii) Reqd trailing cable, Suspension Traction media i.e. belt/ steel wire rope as per OEM recommendations etc FEATURES : (a) Direction and position indicator in COP & LOP . (b) Emergency Alarm. (c) Three way intercom with hand free option for car (d) Attendant key switch for COP (e) Fireman switch at main lobby (f) Emergency light with rechargeable battery and connected equipment for charging (g) Adjustable guide shoes (h) Lift announcer (i) Accurate levelling, automatic closed door (j) Load weighing device with overload warning (k) Automatic phase sequence corrector & single phasing protection, under voltage and over voltage protection. (l) Manual rescue Operation (m) Automatic (Emergency) rescue device/automatic landing device with audio announcer to be operated with maintenance free batteries for safe landing as specified. (n) Other Equipments, accessories, safety devices reqd as per recommendation of OEM
(o) Auto On/Off light/fan mode. Notes : i) The Lifts shall be installed by the original equipments manufacturer only. ii) The Lifts shall be tested by IEM at the time of installation in the attendance of manufacturer. iii) The designing of the lift shall be as per existing lift shaft. The lift shall be installed as replacement in existing lift shaft. iv) The scope of work also covers the civil work comprising cutting of holes /opening and making good the surfaces, provn of counter weight, guide rails and bracket , terminals buffers supports and cill angle, plates, load beam, MS channel, over speed governor and any other items required for successful completion of lift with respect to safety required by the OEM, will be carried out by the contractor without any extra cost. (v) The provision of suitable steel structure/platform for installation of lifts equipment is part of lift items and nothing extra shall be paid. (vi) If any clearance is required to seek from state Govt i.e. from lift inspector or electrical safety department or fire safety department, which will be contractor's responsibility & any expenditure on this account shall deemed to be included in the quoted unit rates. (vii) The quoted rate shall include two year comprehensive maintenance of lifts by OEM.
(viii) The design details of lift shall be submitted by the contractor once the same is approved by the CWE. Make of Lifts : KONE/ SCHINDLER/ OTIS/ HITACHI/ JOHNSON
Material and labour for Earthing complete for with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore light grade as protection pipe (from top of earth plate up to the body of equipment) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 x 300 x 300mm (top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate and angle iron frame including necessary excavation/ earth work in any type of soil/rock, test point of GI strip and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified.(cost of protection pipe up to 7.5metres from earth electrode will be included in the unit rate quoted by the contractor) complete all as specified and directed.
Material and labour for Earth continuity conductor or main earth lead fixed on wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to pole or any other indicated as required on ground for 25x3 mm dia aluminium strip complete all as specified and as directed.
Supply, laying and testing XLPE insulated, PVC sheathed, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm 3 1/2 core laid in trenches/ under roads/ through pipes/ along the wall complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note : Punned thickness of 18cm will be measured for payment.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-Charge.
Dismantling of existing BER lift of 20 passenger/1360 Kgs to serve G+ 3 upper floor of any make complete with all accesories such as machine, cabin Doors, Guide rails, CWT (counter weight), Car, Rope, Wiring and Control panel etc complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing BER lift of 20 passenger/1360 Kgs to serve G+ 1 upper floor of any make complete with all accesories such as machine, cabin Doors, Guide rails, CWT (counter weight), Car, Rope, Wiring and Control panel etc complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing BER lift of 10 passenger/680 Kgs to serve G+3 upper floor of any make complete with all accesories such as machine cabin Doors, Guide rails, CWT (counter weight), Car, Rope, Wiring and Control panel etc complete all as specified and as directed by Engineer-in-Charge. Note for Srl Item No. 10.15 to 10.17 : The lift will be dismantled by one by one or as directed by Deptt.
CENTRAL AC PLANT WORKS
Central air conditioning with AHU and VRF outdoor unit : Design, Supply, Installation Testing and Commissioning of Central air conditioning with AHU and VRF outdoor unit, multi unit air-conditioning system of capacity 3 x 20.8 TR (2 x 20.8 TR working and 1 x 20.8 TR standby) for X-ray ward at Ground Floor of MH Jalandhar suitable for year round air conditioning to maintain inside conditions DBT 22 ± 2 Degree C and RH (55 ± 5) % with 6 air changes per hour as per floor plan given in PS for outside conditions of Jalandhar Cantt as per IMD record. The units shall be of Heat Pump type, air cooled, factory fabricated and factory assembled and shall be capable of providing both cooling and heating complete as per specification given here under :- OUTDOOR UNIT Supply, Installation Testing and Commissioning of outdoor units comprising of 20.8 TR, Top discharge Outdoor unit of Model No. IVRFB-26THN - 03 Nos of Blue Star or equivalent in Voltas/ Carrier/ Daikin / Trane including vaccumising , Gas charging of Modular type units having actual capacity at 43 Degree C outside temp and providing non stop cooling upto 56 Degree C. Outdoor units shall comprise of highly efficient scroll compressors, with all Inverter Scroll type compressor(s), heat exchanger, low noise condenser fan, auto check function for connection error etc, centralize controller for individual control complete as per OEM specifications. Note - 1. The Minimum COP at AHRI conditions shall be min 3.8 at 100% load 2. The ODUs shall be capable of operating upto 56 deg C. 3. Leakage test for copper pipe will be done by contractor after installation. 4. Pressure testing & charging of refrigerant R 410a gas of complete AC system will be performed as required at site. 5. ODU shall be installed at suitable loc as directed by dept for X-ray Ward (ground floor).
Central air conditioning with AHU and VRF outdoor unit : Design, Supply, Installation Testing and Commissioning of Central air conditioning with AHU and VRF outdoor unit, multi unit air-conditioning system of capacity 2 x 12.8 TR (1 x 12.8 TR working and 1 x 12.8 TR standby) for Med-I ward (2nd Floor) of MH Jalandhar suitable for year round air conditioning to maintain inside conditions DBT 22 ± 2 Degree C and RH (55 ± 5) % with 6 air changes per hour as per floor plan given in PS for outside conditions of Jalandhar Cantt as per IMD record. The units shall be of Heat Pump type, air cooled, factory fabricated and factory assembled and shall be capable of providing both cooling and heating complete as per specification given here under :- OUTDOOR UNIT Supply, Installation Testing and Commissioning of outdoor units comprising of 12.8 TR, Top discharge Outdoor unit of (Model No IVRFB-16TH - 02 Nos of Blue Star or equivalent in Voltas/ Carrier/ Daikin / Trane including vaccumising , Gas charging of Modular type units having actual capacity at 43 Degree C outside temp and providing non stop cooling upto 56 Degree C. Outdoor units shall comprise of highly efficient scroll compressors, with all Inverter Scroll type compressor(s), heat exchanger, low noise condenser fan, auto check function for connection error etc, centralize controller for individual control complete as per OEM specifications. Note - 1. The Minimum COP at AHRI conditions shall be min 3.8 at 100% load 2. The ODUs shall be capable of operating upto 56 deg C. 3. Leakage test for copper pipe will be done by contractor after installation. 4. Pressure testing & charging of refrigerant R 410 gas of complete AC system will be performed as required at site. 5. ODU shall be installed at suitable loc as directed by dept for Med-I ward (2nd Floor).
Design, Supply, installation, testing and commissioning of factory built, weather proof, floor mounted double skin DX type, Air handling unit (AHU) of cap 41.6 TR Cabinet Type, with Filters having Air handling cap 16600 CFM , SP 125mm wg (for X- Ray ward at Ground floor) complete with specifications and capacities as under :- (a) Panel Construction and Casing. (b) Frame: Thermal break aluminium profile with thermal barrier with 32 mm thick panels. Frame should be assembled using glass fibre reinforced nylon joints/ corner. (c) Panel: Panel shall be double construction, CFC free PUF insulation panel 32+-2mm thick having density 40 ± 2 Kg/M3. factory injected by injection moulding machine. Outer skin-----0.8 mm thick pre coated GI sheet. Inner skin ----0.8 mm thick plain GI sheet. (d) AHU shall have Water Tight Positive Pressure access/ service door duly interlocked with fan. AHU shall have Thermally insulated totally sealed glass inspection window. Door shall be hinged type, hinged shall be casted powder coated zinc alloy. Flush Lock and Handle shall be of glass fiber reinforced polyamide . Inspection lamp with limit switch . (e) Base Frame : Base frame made of G.S.S. (f) Mixing Box Section : Mixing box shall have fresh air, return air damper. The dampers shall be made of low leakage Aerofoil design in Aluminium Anodised. (g) Filter Section : Filter section with 50 mm thick box type pre- filter (MERV-8), 305 mm thick microvee filter mounted on a common filter frame and 305 mm thick HEPA filter having efficiency 99.9% down to 0.3 micron. Pre filters shall have efficiency 90% down to 10 micron and fine filters having efficiency 95% down to 5 micron. Make : Mechmaark/ Spectrum/ American Airfilters. (h) COIL SECTION : The 3 set of cooling coil having 6 Rows Deep each having suitable coil correspond to each ODU , copper tubes of suitable dia with thickness not less than 0.5 mm as per OEM recommendations, with aluminium fins & Drain pan. The Drain Pan material shall be SS-304 and drain Pan thickness 20 gauge duly insulated with 13mm closed cell Nitrile insulation for drain tray. Note : The Coil should be AHRI Certified .
(j) FAN SECTION : (i) Blower Section with blower DIDW backward curved centrifugal fan with suitable capacity T.E.F.C motor. (ii) Fan shall be dynamically trim (Two stage) balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade after assembly. (iii) Fan Impeller should be made of Cold Rolled sheet steel polyester powder coating, Fan Inlet Cone must be Spurn GSS having GSM 220, zero sprangle . (iv) Impeller should be directly coupled on Motor shaft to avoid any maintenance & to save drive transmission losses. (v) Fan assembly should be mounted on Cushy foot mounted Vibration isolator. Make of Cushy foot mountains : Kruger/ Vibrosolve (vi) Fan performance curve should be of Single RPM curve. It should not be multi RPM curve. Make of Fan : Nicotra/Kruger/Greenheck. Make of Motor : Siemens/Bharat Bijlee/Havells. (vii) AHU manufacturer should not fabricate Fan motor structure etc at their manufacturing unit and they should supply entire assembly from fan manufacturer (k) Provision for Pan Humidifier : (i) Provision for Pan Humidifier (only space for pipe insertion and necessary accessories/ fitting reqd for making the AHU airtight. Pan humidifier will be mounted outside the unit as per Item srl No. 11.05). Make of AHU :- Edgetech/ M/s system Air/ Citizen/ Zeco Bahadurgarh.
All as per srl item No. 11.03 here-in-before but capacity 12.8 TR, 4800 CFM with SP 65mm wg having 2 set of cooling coil having 6 row deep each (For Med-I Ward at 2nd Floor ) Note for AHU's srl item No. 11.03 & 11.04: The scope of AHU shall also include following:- (a) AHU's shall be mounted on P.C.C. plateform/ blocks with neoprene pads in between. (b) Set of each Thermometer & pressure guage bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) for cooling coils at inlet and outlet, or any other item as recommended by OEM COIL UNIT : Edgetech/M/s system Air/Citizen/Zeco Bahadurgarh or as per OEM of AHU
Supply and installation of Pan type Humidifier and humidistat of cap 4.5 KW each for X Ray Ward (at Ground Floor) AHU and Med- I Ward (at 2nd Floor) made from stainless steel 304 sheet in welded construction, inlet, drain and steam outlet nozzle, 25 mm thick fibre glass wool (150 Crown) and cladded with 22 Gauge GI Sheet . Controls comprising of low level switch, float valve with SS ball , sight glass , high temp cut out thermostat ,digital humidistat with necessary wiring with copper bus bar connector. Note : One set for AHU of X-Ray ward (Ground Floor) & another set for AHU of Med I ward (Second floor). Make: Honeywell/Siemens/Rapid Cool.
Supply and Installation of AHU Expansion kit for Outdoor unit 20.8 TR cap complete as specified as per OEM recommendation for automatic control of temp & RH in X-Ray Ward (Ground Floor) including reqd no of air sensor with suitable mounting arrangement & necessary safety protection, interlocking with heat pump as per OEM recommendation. Model No. VAEKIT - 320 of Blue Star or equivalent in Voltas / Carrier / Daikin. Note : Cost for control cable for interconnection are deemed to be included in scope of work as per manufacturer instructions.
Supply and Installation of AHU Expansion kit for Outdoor unit 12.8 TR cap complete with expansion valve, remote as specified as per OEM recommendation for automatic control of temp & RH in Med I ward (2nd Floor) including reqd no of air sensor with suitable mounting arrangement & necessary safety protection, interlocking with heat pump as per OEM recommendation. Model No. VAEKIT - 150 of Blue Star or equivalent in Voltas / Carrier / Daikin. Note : Cost for control cable for interconnection are deemed to be included in scope of work as per manufacturer instructions. Notes for Srl item No. 11.01 to 11.07 :- (i) The contractor should get the plant designed, supplied, installed and testing Commissioning only by any one of the Original Equipment Manufacturer (OEM) namely Blue Star/Voltas / Carrier / Daikin / Trane with their own makes (or) with their recommended makes for the components which are not manufactured by OEM. Any other makes which are other than OEM (or) other than OEM recommended makes shall not be accepted. Contractor shall submit proper documentary evidence before procurement action for all the items from any of the OEM's given. (ii) The contractor shall intimate any one of OEM out of M/S Blue Star/Voltas / Carrier / Daikin / Trane along with a certificate from the OEM confirming that the entire AC plant work shall be got designed, supplied, installed, tested/ commissioned by the OEM and will obtain approval of the GE before engaging the OEM. (iii) The OEM shall submit heat load calculation sheet for summer, winter and monsoon for X-ray ward and Med-I ward separately alongwith GA drawing of AC plant, SLD for refrigeration circuit showing loc of various valves, pressure switches, safety protection,SLD for power and control cabling, wiring/circuit diagram of control panel, drawing of AHU, air circuits drawing showing loc of AHU, Pan humidifier, AHU expansion kit, duct layout showing loc of fire damper, supply air and return air grill, ODU for approval of CWE before procurement / installation.
(iv) The capacity / tonnage of AC plant as given above is tentative for guidance only. If tonnage of the AC plant based on heat load conditions worked out more than 10%, the variation on plus side, if any shall be deemed to be included in qouted rates. In case capacity worked out is less than 10%, minus price adjustment at market rate as per invoice shall be made from the payment due to the contractor. (v) The rate quoted is deemed to be inclusive of construction of mounting platform / foundation for ODU, AHU as per OEM reccomendation, making cut/ hole in wall, inserting PVC/ suitable material sleeve for copper piping and making good the disturbed surfaces to match with adjoining surfaces as per standard Engineering practice recommended by OEM. (vi) The contractor shall conduct Nitrogen test and vacuum test on refrigerant piping minimum for 02 days before commissioning. Start and stop timing & pressure maintained shall be checked and the readings recorded shall be counter signed by Engineer- in- Charge. The unit rate quoted is deemed to be inclusive of these tests. (vii) The contractor shall submit 03 sets of the wiring diagram, SLD of copper piping, ducting layout, final layout of grills, outdoor units and technical literature, operation & maintenance schedule, trouble shooting chart of AHU & AC plant on satisfactory testing and commisiioning of AC plant.
Supply, installation, testing/ commissioning of cubical compartment type wall mounted electrical control panel for AHU starter, Pan Humidifer with necessary switchgear, starter and protection for 41.6 TR AHU complete all as specified and directed as per recommendations of OEM. (For AHU of X ray ward)
Supply, installation, testing/ commissioning of cubical compartment type wall mounted electrical control panel for AHU starter, Pan Humidifer with necessary switchgear and protection for 12.8 TR AHU complete all as specified and directed as per recommendations of OEM. (For AHU of Med I ward)
Supply, Installation, testing and commissioning of Interconnecting refrigerant copper pipe of size 34.9 mm dia (OD) for 41.6 TR AHU with required fitting like elbow ,couplers ,tee , joints, brass fitting,"U" loops etc work with closed cell elastomeric nitrile rubber tubular insulation 19mm thick with glass cloth between AHU & outdoor units as per specifications, all piping inside the room/ corridor shall be properly supported with MS hanger and all external piping shall run in covered cable tray and the exposed piping should be insulated with factory backed glass cloth for mechanical and UV protection as per specifications and as Engrs practice.
All as per srl item No. 11.10 here-in-before but 28.6mm dia (OD) with 19mm thick insulation for 12.8 TR AHU.
All as per srl item No. 11.10 here-in-before but 19.05mm dia (OD) with 19mm thick insulation for 41.6 TR AHU.
All as per srl item No. 11.10 here-in-before but 12.7mm dia (OD) with 19mm thick insulation for 12.8 TR AHU. Note for item No. 11.11 to 11.13 : The dia of pipe as given above is minimum, if the pipe size is required in higher size as per design nothing extra will be paid.
Supply, Installation, testing and commissioning of 40mm dia UPVC piping pressure rating 10 kgf/cm2 (IS No-4985) complete with fittings, supports complete as per specifications and as directed.
Supply, Installation, testing and commissioning of 32mm dia UPVC piping pressure rating 10 kgf/cm2 (IS No-4985) complete with fittings, supports complete as per specifications and as directed.
Design , supply, installation, testing, balancing and commissioning of supply air ducting and return air ducting system made of factory GSS sheet of thickness 20 Gauge confirming to IS: 277 with Zinc coating of not less than 120 grade, site fabricated as per SMACNA-1995 standard and as per IS:655 , complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications complete as required. Make: Sail/Tata/Jindal.
All as per srl item No. 11.16 here-in-before but made of Galvanized sheet steel thickness 22 gauge
All as per srl item No. 11.16 here-in-before but made of Galvanized sheet steel thickness 24 gauge
Supply, installation, testing and commissioning of closed cell Nitrile rubber insulation 13mm thick of density min 40 - 60 kg/m3 with proper adhesive and sealed with 75 mm wide BOPP Tape on all longitudinal/transverse joints on ducts complete as per specifications. Make : Supreme/UP Twiga/Kflex/Armaflex
Supply and Application of internal acoustic lining of 10 mm thick over supply air ducting using open cell nitrile rubber insulation with density within 30-40 Kg/m3 as per the approved shop drawings and specifications. Insulation material shall be bonded with the ducts using metal screw and washers to facilitate grip to the GI sheet. Make : Supreme/UP Twiga/Kflex/Armaflex
Supplying & fixing of opposed blade aluminium construction volume control dampers adjustable in duct collars as per approved drawings and specifications. Make Systemair /caryaire /Trox.
Supply and fixing linear type alumimium air grill for supply air complete with OBSS damper all as specified and directed. Make Trueaire/Uniaire
Supply and fixing linear type alumimium air grill for return air complete all as specified and directed. Make Trueaire/Uniaire
Supplying & fixing of opposed blade GSS construction volume control dampers in duct as per approved drawings and specifications. Make Systemair /caryaire /Trox.
Supplying & fixing fire dampers in return duct as per approved drawings and specifications. Make Systemair /caryaire /Trox.
Supply and fixing Fire retardant non porous double layer flexible canvass connection between each indoor unit and duct as per approved drawings and specifications. (Dismantling of false ceiling and provn of new ceiling considered under B/R items)
Supply and fixing of powder coated MS cable tray of size 50mm x 300mm x 50mm of thickness 1.6mm of perforated type with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ wall with M.S. suspenders including nuts, bolts, painting of suspenders etc as reqd for running copper refrigerant piping/copper wire/LT cable complete all as specified and directed.
Supplying and fixing control wiring of PVC insulated and sheathed 2 core x 1.5 sq. mm. copper conductor (confirming to IS) in PVC concealed/surface conduits medium grade inclusive of all tees, bends, elbows, reducers and accessories including cutting chases for conduits and making good wall, floor etc between indoor and outdoor unit complete all as specified and directed.
Supplying and laying/ fixing of XLPE insulated and PVC sheathed copper conductor unarmoured cable as required of 1.1 KV grade for power wiring of 3.5 core x 25 sq. mm (confirming to IS) in PVC concealed/surface conduits medium grade inclusive of all tees, bends, elbows, reducers and accessories including cutting chases for conduits and making good wall, floor etc or through pipe/ in duct/ on surface/ on cabel tray complete all as specified and directed.
All as per srl item No. 11.29 here-in-before but of size 4 core x 10 sqmm
All as per srl item No. 11.29 here-in-before but of size 4 core x 16 sqmm
All as per srl item No. 11.29 here-in-before but of size 4 core x 6 sqmm
DUCTED EVAPORATIVE AIR COOLER Supply , install , commissioning and testing of ducted evaporative air cooler of capacity 6000 CFM or next higher capacity, Side discharge made of pre plasticized coated galvanised steel body , complete assembled with suitable capacity 3 phase electric motor, 100mm thick pads, pump, pully and starter, suitable duct opening and ISMC supporting structure channel to be installed at first floor complete confirming to Model ADC-35K of ARCTIC or equivalent of make EVAPOLAR/ AIREF /BREEZE AIR with the following specifications:- Location : for Casualty located at ground floor. i) Minimum evaporation efficiency - 90% ii) Pad type & thickness - Cellulose pads,100mm thick iii) Fan type - Centrifugal iv) Air flow at 20 Mtr WC External Static pressure - 15000 m3/hr Minimum v) Starter with suitable size MCB and single phase preventor vi) Suitable cap water tank
Providing and fixing Fire retardant non porous double layer flexible canvass connection between Ducted Evaporative Air cooler and duct as per approved drawings and specifications.
Supply and fixing of powder coated MS cable tray of size 40mm x 100mm x 40mm of thickness 1.6mm of perforated type with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ wall with M.S. suspenders including nuts, bolts, painting of suspenders etc as reqd for running copper refrigerant piping/copper wire/LT cable complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY WORKS
Supply Install , testing and commissioning of LT Distribution Panel (CPRI Approved) cubicle type, Indoor type, factory fabricated made out of 2mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC/ epoxy insulator . The incoming as well as outgoing MCCBs shall have extersion links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. The cubicle shall have 60 CM long 4 legs of size 50 x50 x 6mm angle iron, grouted in PCC 1:3:6 as directed by Engr-in-Charge . A detacheable gland plate of thickness not less than 2 mm thick should be used at the botom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following . (For X Ray ward AC plant.) Note:- The LT panel should be CPRI approved as per IS -5039 of 1983. Incoming:- (a) MCCB 160 Amp 4 Pole, 25 KA, 415 V, with Thermal magnetic release - 01 No. (b) Busbar TPN, Copper 250 Amps - 01 Set (c) Digital type multi function meter to display Voltage, current , Freq, PF with suitable ratio CT's - 01 Set (d) LED indicator - 01 Set (RYB) Outgoing:- (a) MCCB 4 Pole,63 Amp 16 KA, 415 V, with Thermal Magnetic Release - 03 Nos. (b) MCCB 4 Pole, 40 Amp, 16 KA, 415 V, with Thermal Magnetic Release - 01 Nos. (c) MCB TPN 40 Amp, 10 KA - 01 No (d) Spare space for FP MCCB 125 Amp, 25 KA-01 No.
Supply Install , testing and commissioning of LT Distribution Panel (CPRI Approved) cubicle type, Indoor type, factory fabricated made out of 2mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC/ epoxy insulator . The incoming as well as outgoing MCCBs shall have extersion links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. The cubicle shall have frame work, bottom & 60 CM long 4 legs of size 50 x50 x 6mm angle iron, grouted in PCC 1:3:6 as directed by Engr-in-Charge . A detacheable gland plate of thickness not less than 3 mm thick should be used at the botom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following . (For Med I ward AC plant at 2nd Floor) Note:- The LT panel should be CPRI approved as per IS -5039 of 1983.
Incoming:- (a) MCCB 125 Amp, 4 Pole, 25 KA, 415 V, with Thermal magnetic release - 01 No. (b) Busbar TPN, Copper 250 Amps - 01 Set (c) Digital type multi function meter to measures Voltage, current, Freq, PF with suitable ratio CT's - 01 Set (d) LED indicator - 01 Set (RYB) Outgoing:- (a) MCCB 63 Amp 4 Pole, 16 KA, 415 V, with Thermal Magnetic Release - 02 Nos. (b) MCCB 25 Amp 4 Pole, 16 KA, 415 V, with Thermal Magnetic Release - 01 Nos (c) MCB TPN 32 AMp -01 No (d) Spare space for FP MCCB 63 Amp, 16 KA-01 No.
Material and labour for Cross arms, bracings,supports and supporting clamps, and back plates fabricated from structural steel sections including nuts and bolts,washers,welding,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat, and one under coat and one finishing coat of paint.
Supply and lay XLPE insulated PVC sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor 50 sqmm 3.5 core laid in trenches/ under roads/ through pipes/ along the wall complete all as specified and directed.
Supply and lay XLPE insulated PVC sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor 120 sqmm 3.5 core laid in trenches/ under roads/ through pipes/ along the wall complete all as specified and directed.
Dismantling of existing central type AC plant 3x 10 TR with all connected equipments, old duct installed at X ray dept (Ground floor) and deposit to MES store yard including transportation all as specified and directed.
Dismantling of existing central type AC plant 3x 5.5 TR with all connected equipments, old duct installed at Med-I ward (2nd floor) and deposit to MES store yard including transportation for taking credit all as specified and directed.
Dismantling of existing package type cold storage room plant with all connected equipments i.e. Indoor and outdoor unit installed at ECHS Med Store (Ground floor) and deposit to MES store yard including transportation for taking credit all as specified and directed.
Dismantling of existing evaporative air cooler with all connected equipments installed at Casualty (First floor) and deposit to MES store yard including transportation for taking credit all as specified and directed.
Dismantling of existing armoured cable and removing from site all as specified and directed.
Dismantling of existing LT panel and removing from site all as specified and directed.
NAFREF ENGINEERS PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .