Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.1 L+₹72,878 (2.01%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹38.2 L+₹1.8 L (5.04%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹38.2 L+₹1.8 L (5.06%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹39.8 L+₹3.4 L (9.45%)Rejected-Finance VILL MOKHAWA TEHSIL GUDAMALANI DIST BARMER RAJASTHAN 344031 | GUDAMALANI | BARMER | RAJASTHAN | 344031 | L5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | shivam electricals and engneers L6 | Rasam Engg Co. L7 | M/s Yash Electrical and Maintenance L2 | M/s Shree Construction Company L4 | AUTOMATION AND SWITCHGEAR PANELS L3 | NAGEL ENTERPRISES L5 | SHRI HARI CONSTRUCTION L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge. | 690 | Cum | 260 ₹1,79,400 | 250 ₹1,72,500 | 250 ₹1,72,500 | 177 ₹1,22,130 | 150 ₹1,03,500 Lowest | 200 ₹1,38,000 | 200 ₹1,38,000 |
| 2.00 | Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge. | 0.7 | Cum | 50 ₹35 Lowest | 500 ₹350 | 500 ₹350 | 200 ₹140 | 200 ₹140 | 1,000 ₹700 | 850 ₹595 |
| 3.00 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/loose soil complete all as specified & directed by Engineer-in-Charge. | 670 | Cum | 30 ₹20,100 | 60 ₹40,200 | 50 ₹33,500 | 40 ₹26,800 | 70 ₹46,900 | 25 ₹16,750 Lowest | 40 ₹26,800 |
| 4.00 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge. | 20 | Cum | 50 ₹1,000 | 60 ₹1,200 | 10 ₹200 Lowest | 55 ₹1,100 | 50 ₹1,000 | 25 ₹500 | 40 ₹800 |
| 5.00 | Supplying, laying, testing and commissioning of LT UG, XLPE insulated, heavy duty, 1100V grade of size 120 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old existing unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:-
Note : - Earthwork excavation, protection pipe shall be measured and paid separately in their respective items | 350 | RM | 770 ₹2,69,500 | 850 ₹2,97,500 | 730 ₹2,55,500 | 757 ₹2,64,950 | 800 ₹2,80,000 | 721 ₹2,52,350 | 666 ₹2,33,100 Lowest |
| 6.00 | All as per item No 5 above but of size 95 sq mm. 3½ core | 400 | RM | 600 ₹2,40,000 | 670 ₹2,68,000 | 580 ₹2,32,000 | 600 ₹2,40,000 | 550 ₹2,20,000 | 580 ₹2,32,000 | 532 ₹2,12,800 Lowest |
| 7.00 | All as per item No 5 above but of size 70 sq mm. 3½ core | 400 | RM | 485 ₹1,94,000 | 545 ₹2,18,000 | 460 ₹1,84,000 | 470 ₹1,88,000 | 600 ₹2,40,000 | 450 ₹1,80,000 | 423 ₹1,69,200 Lowest |
| 8.00 | All as per item No 5 above but of size 50 sq mm. 3½ core | 300 | RM | 360 ₹1,08,000 | 400 ₹1,20,000 | 340 ₹1,02,000 | 355 ₹1,06,500 | 380 ₹1,14,000 | 350 ₹1,05,000 | 314 ₹94,200 Lowest |
| 9.00 | All as per item No 5 above but of size 35 sq mm. 3½ core | 400 | RM | 260 ₹1,04,000 | 299 ₹1,19,600 | 245 ₹98,000 | 280 ₹1,12,000 | 320 ₹1,28,000 | 260 ₹1,04,000 | 233 ₹93,200 Lowest |
| 10.00 | All as per item No 5 above but of size 25 sq mm. 4core | 500 | RM | 240 ₹1,20,000 | 265 ₹1,32,500 | 215 ₹1,07,500 | 245 ₹1,22,500 | 280 ₹1,40,000 | 230 ₹1,15,000 | 194 ₹97,000 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Oct 2025, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
REPAIR AND MAINT OF LT UG CABLE, LT PANELS AND ALLIED WORKS AT JAISALMER MIL STN
2025_MES_732916_1
8504/25-26/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Army Jaisalmer
₹80,000
Yes
2 Jan 2026
26 Sept 2025
28 Oct 2025
26 Sept 2025
24 Oct 2025
10 Oct 2025
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/loose soil complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Supplying, laying, testing and commissioning of LT UG, XLPE insulated, heavy duty, 1100V grade of size 120 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old existing unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : - Earthwork excavation, protection pipe shall be measured and paid separately in their respective items
All as per item No 5 above but of size 95 sq mm. 3½ core
All as per item No 5 above but of size 70 sq mm. 3½ core
All as per item No 5 above but of size 50 sq mm. 3½ core
All as per item No 5 above but of size 35 sq mm. 3½ core
All as per item No 5 above but of size 25 sq mm. 4core
All as per item No 5 above but of size 16 sq mm. 4 core
All as per item No 5 above but of size 10 sq mm 2 core
Re-laying /fixing only existing , XLPE insulated , Armoured , Electric Power UG Cable (Heavy Duty) , 1100 Volt Grade of any Cross sectional area complete all as specified & directed by Engineer-in-Charge. Note : Excavation, earth work, Pipe etc measured and paid separately.
Supply and laying DOUBLE WALLED CORRUGATED (DWC) pipe 90 mm bore as per IS-14930 part--2/IS-16205 part-24 for cable protection including all fittings as required complete all as specified & directed by Engineer-in-Charge.
Supply and laying DOUBLE WALLED CORRUGATED (DWC) pipe 75 mm bore as per IS-14930 part--2/IS-16205 part-24 for cable protection including all fittings as required complete all as specified & directed by Engineer-in-Charge.
Supply and laying DOUBLE WALLED CORRUGATED (DWC) pipe 63 mm bore as per IS-14930 part--2/IS-16205 part-24 for cable protection including all fittings as required complete all as specified & directed by Engineer-in-Charge.
Supply and laying DOUBLE WALLED CORRUGATED (DWC) pipe 50 mm bore as per IS-14930 part--2/IS-16205 part-24 for cable protection including all fittings as required complete all as specified & directed by Engineer-in-Charge.
Supply and fixing MCCB 4 Pole 400 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 250 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 200 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 160 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 100 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 pole 63 Amps rupturing capacity 16 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge.
Supply and fixing MCB TPN 100 Amps rupturing capacity 10 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCB complete all as specified & directed by Engineer-in-Charge.
Supply and fixing MCB TPN 63 Amps rupturing capacity 10 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCB complete all as specified & directed by Engineer-in-Charge.
S&F in repair, MCB Tripple pole and netural rated capacity 32 Amps, 415 volts breaking capacity 10 KA complete all as specified & directed by Engineer-in-Charge.
S&F in repair, MCB Single pole and netural rated capacity 40 Amps, 240 volts breaking capacity 10 KA complete all as specified & directed by Engineer-in-Charge.
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified & directed by Engineer-in-Charge.
S&F steel water tubing 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 80 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
Supplying, installing, testing and commissioning out door type LT feeder piller box of size1200x1100x800mm, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down existing unsv Panel etc complete all as specified and as directed. The panel shall consists of following accessories:-
Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T Part No- WL411021OO00 (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T- Part No- SIL-00000. (iv) Bus bar strips made of Aluminium 400 Amps (Hindalco Make)of size 50 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 250/5A) -03 Nos
OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 01 Nos (b) MCCB 4 Pole of capacity 100 Amp , breaking capacity 25 KA with thermal release -02 No (c) MCB TPN 63 Amps, 415 Volt, 'C' Curve, 10 KA -02 Nos (c) MCB SPN 40 Amps, 230 Volt, 'C' Curve, -02 Nos (e) Internal control wiring with 1100 volt grade 1.5 Sq.mm stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified.
Supplying, installing, testing and commissioning out door type LT feeder piller box of size1200x1100x800mm, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down existing unsv Panel etc complete all as specified and as directed. The panel shall consists of following accessories:-
Incoming Side (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T Part No- WL411021OO00 (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T- Part No- SIL-00000. (iv) Bus bar strips made of Aluminium 400 Amps (Hindalco Make)of size 50 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 250/5A) -03 Nos
OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 01 Nos (b) MCCB 4 Pole of capacity 100 Amp , breaking capacity 25 KA with thermal release -02 No (c) MCB TPN 63 Amps, 415 Volt, 'C' Curve, 10 KA -02 Nos (c) MCB SPN 40 Amps, 230 Volt, 'C' Curve, -05 Nos (e) Internal control wiring with 1100 volt grade 1.5 Sq.mm stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified.
S & F feeder pillar made out of 3.15mm CRCA sheet, power coated minimum 80 Micron, weather proof, size not lett than 800 (w)x600(H)x500(D) mm out door single dooor, with FRP inculstor 1100V , Aluminium Busbar 200 Amps current density not less than 2.0 shall be mounted on MS angle stand 40x40x5mm height 400mm above ground level and 200mm under PCC structure, earthing bolt to be provided M10 complete including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in-Charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 25 x 3 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified & directed by Engineer-in-Charge.
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shap, supply, fixing and febrication in existing, shap and size with and including 3 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc complete all as specified & directed by Engineer-in-Charge. NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/ Switch fuses/cable etc complete all as directed. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer. (iv) The rates quoted by the contractor deemed to be with and including dismantling/taking out/removing carefully, any damaed part/portion of the feeder pillar box/panel board as directed.
Dismantling of 9 mtr long PCC/RCC poles after breaking the foundation concrete including necessary excavation of earth, filling the hole with broken pieces of concrete and making good the disturbed area by filling excavated earth, obtained from the hole for new pole to be erected nearby area, to match with the surroudings complete all as specified & directed by Engineer-in-Charge.
M &L steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 mtrs long) including painting with two coats of aluminium paint over a coat of red oxide metal primer complete all as specified & directed by Engineer-in-Charge.
M&L for painting the old existing LT panel board /feeder pillars including scraping and removing the old painted surfaces and painting /matching the same colour paint including two coats of super enameled paint (Gray paint) and without distrubing the existing electric system and removing grass and bushes including its roots growing around the panel complete all as specified & directed by Engineer-in-Charge.
M&L straight through joints for under ground cable including joints kit with labour complete for making joints suitable for aluminium conductor cables of size 16 to 25 Sqmm mm 4 core. and including taking up of old existing joints complete all as specified & directed by Engineer-in-Charge.
M&L straight through joints for under ground cable including joints kit with labour complete for making joints suitable for aluminium conductor cables of size 35 to 50mm 3½ core and including taking up of old existing joints complete all as specified & directed by Engineer-in-Charge.
M&L straight through joints for under ground cable including joints kit with labour complete for making joints suitable for aluminium conductor cables of size 95mm 3½ core and including taking up of old existing joints complete all as specified & directed by Engineer-in-Charge.
M&L straight through joints for under ground cable including joints kit with labour complete for making joints suitable for aluminium conductor cables of size 3½ core of size 120sqmm to 185 sqmm of 3½ core and including taking up of old existing joints complete all as specified & directed by Engineer-in-Charge.
S & F in repair LT cable route indicator made out of cast iron plate of 150 mm dia 4mm thick having embosed wiriting LT cable fixed on MS angle iron 30x30x5 mm of 900 mm long with two nuts,bolts and grouting 500 mm length under ground and splitted and bent to shape and embedded in ground with PCC (15 cmx 15cm x 15 cm) complete all as specified & directed by Engineer-in-Charge.
M&L for finding cable fault with electronic fault detector in LT/HT UG cable of any size complete including earthwork and jointer complete all as specified & directed by Engineer-in-Charge. Note:- LT/HT UG Cable and cable joints kit etc shall be measured and paid separately
Material and labour for spreading levelling with 20 mm graded coarse aggregate / gravells laid approximately 75 mm thick layers near Feeder pillar/2/4 pole structure and plateform etc complete all as specified & directed by Engineer-in-Charge.
Supply and fix in repairs digital Ammeter 0-800 Amps, 3phase for existing panel complete all as specified & directed by Engineer-in-Charge.
Supply and fix in repair digital volt meter 0-500 Volts, 3phase for existing panel complete all as specified & directed by Engineer-in-Charge.
Supply and fix in repair LED Indicating lamp of main supply indicating 'R', 'Y', 'B' (set of three) complete all as specified & directed by Engineer-in-Charge.
S& F in repair Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. complete all as specified & directed by Engineer-in-Charge. Make- L&T Part No- WL411021OO00
M&L for plain cement concrete( 1:4:8) type D2 using 40mm graded aggregate as in foundation for pole etc complete all as specified & directed by Engineer-in-Charge.
M&L for plain cement concrete( 1:3:6) type C2 using 40mm graded aggregate as in foundation for pole etc complete all as specified & directed by Engineer-in-Charge.
M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggregate as in coping and footing for polesetc including necessary formwork complete all as specified & directed by Engineer-in-Charge.
Dismantling cross arms of MS channels or angle sections etc complete all as specified & directed by Engineer-in-Charge.
M & L for cross arms bracing support clamps and back plates channel or angle section nuts bolts etc after painting with two coat of aluminium paint over one coat of red oxide primer complete all as specified & directed by Engineer-in-Charge.
Taking down existing cracked/unserviceable Pin type insulator and supply and fixing new Pin type insulator porcelain vitreous white, brown or green including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nuts 65 mm dia 100mm height for 1100 volts grade complete all as specified & directed by Engineer-in-Charge.
Re-stringing and re-connection of ACSR of any size duly binded with insulators, jumpers etc.(fixed on 9/11mtr poles) complete all as specified & directed by Engineer-in-Charge. Note : (i) The above work includes cleaning pruning of tree branches falling around the conductors (ii) One length shall be measured for complete span of 4/5/6 conductors & GI wire.
Dismantling & taking down ACSR conductor, of any size, after taking necessary shut down, from 11 KV HT OH line, by loosening the binding wires, jumpers etc. for replacement of insulator / cross arms etc. complete all as specified & directed by Engineer-in-Charge.
S&F ACSR conductor of any size, as required at site, duly binded with insulators, jumpers etc complete all as specified & directed by Engineer-in-Charge.
Cuttting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 2.5 meters both side from the over head line to nearby trees and removing the cutting branches about 50 m from the site complete all as specified & directed by Engineer-in-Charge. Note :- Number of branches of one tree will be measured as one JOB.
M/s Yash Electrical and Maintenance (BID ID -3453550)
AUTOMATION AND SWITCHGEAR PANELS (BID ID -3458708)
M/s Shree Construction Company (BID ID -3453618)
NAGEL ENTERPRISES (BID ID -3454331)
shivam electricals and engneers (BID ID -3450197)
Rasam Engg Co. (BID ID -3451931)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_820623.xls
BOQ • 0.59 MB
TenderDocuments8504.pdf
Tender Documents • 0.90 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .