Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC 12 8 THAKKAMEDU VILLAGE PERUMAL KOVIL STREET KALPAKKAM KANCHIPURAM TAMIL NADU 603102 | CHENGALPATTU | TAMIL NADU | 603102 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹10.2 L+₹1.5 L (16.6%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹11.1 L+₹2.4 L (27.2%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹11.8 L+₹3.0 L (34.3%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹11.9 L+₹3.2 L (36.1%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹21,500
Closing Date
28 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) CHABUA
GE (AF) CHABUA CHABUA AIR FIELD DIST-DIBRUGARH (ASSAM) 786102
PROVN OF GEYSER IN SMQ (PHASE-I) AT AF STN CHABUA
2020_MES_390978_1
283/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(AF) CHABUA
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE(AF) CHABUA
₹21,500
Yes
16 Jan 2021
31 Oct 2020
30 Nov 2020
31 Oct 2020
28 Nov 2020
14 Nov 2020
60 days
Amount
Supply and installation electrical driven water heater storage type 25 Ltr with all accessories all as specified and directed. Make:- Havells cat Part No GHWAMGTWH025 and Bajaj/Usha/Racold/Crompton
Supply and fix heavy duty hot and cold flexible pipe with both side flair nut for 20 mm and 600mm long connecting with GI pipe complete all as specified and directed.
M&L for Point wiring with 2.5 Sq mm (Nominal cross sectional area) single core, multi stranded , PVC insulated, unsheathed copper conductor cable in and including rigid non metallic PVC concealed conduit 20 mm dia or higher medium grade ISI marks complete with all PVC conduit accessories/fittings and sunk CI/pressed steel terminal switch/socket box with 3 mm thick plastic laminated hard glossy surface sheet top cover including continuous earth wire of PVC insulated, unsheathed 1.5 Sq mm copper conductor PVC insulated connected to common earth and connecting to earth dolly, plastic laminated sheet screwed with brass screws, cup washers and all accessories for one three pin 15/16 Amp, socket out let point on independent board complete all as specified and as directed.
Supply & Fixing Switch socket combination 5A/16A, 5 in 1 A flush type all as specified and directed
Supply & Fix SP&N DBs, 4 way double door with 200A rated busbar complete all as specified and directed.
M&L for MCB single pole & neutral 'C' curve, 10 KA, 40 amps complete all as specified and directed.
M&L for MCB single pole, 'C' curve, 10 KA, 6 - 32 amps complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core all as specified and as directed.
Excavation in trenches/foundation in soft/loose soil not exc 1.5 metre wide and n'exc 1.50 m deep for poles, laying of cables, etc and getting out complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated material in soft/loose soil n'exc 50 M and depositing where directed at a level n/exc 1.5 M above the starting point, complete all as specified and directed.
S/F in dry river sand in cable trenches before and after the cables are laid in sand cushioning to cables complete all as specified and directed.
M & L for well burnt bricks, sub class B type laid in trences complete all as specifed and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B or cement mortar (1:3) complete all as specified.
Supply and fiixing sheet steel, Phosphated, Powder coated single door Vertical TPN DB with provision of MCCB incommer 4 way complete all as specified and directed. Make- L&T/Legrend/Havells
Supply and fix of MCCB, 4 Pole, 125 Amps , with breaking capacity 25KA , Thermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM), Ics=100% Icu, AC 415 volt ,50 HZ complete all as specified and as directed. Make- L&T/Legrend/Havells
M/L for Earthing complete with galvanized steel earth plate electrode 60 x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts nuts, check nut and washers of GI and GI tubing 15 mm bore, light grade for earth lead protection up to main earth test point and includingconcrete pit in PCC (1:3:6) typeC 1 pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm with one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing(L. G.) for watering ,charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed Electrical plate no 3 of SSR Part-I.
Supply and draw submain wiring with two single core 6 sqmm FR PVC insulated copper cable 1100 volts grade multistrand, unseathed conductor drawn into FR PVC casing and caping and all necessary fittings including 6 sqmm multi strand FR PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete all as specified and directed.
Supply and Fixing GI tube light grade laid in trenches or fixed on wall, floor or on pole with MS flat iron clamp of size 30 x 2 mm with bolts, nuts and washer of suitable size for cable protection all as specified and as directed.
M/S S. P. ENTERPRISE
FREEZCON
STANDARD ELECTRIC WINDERS
M/s PRABIR ENTERPRISE
M/s HALDER ENTERPRISE
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .