Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹11.1 LAccepted-AOC | I | Accepted-AOC L1 | |
| 2 | II₹11.8 LRejected-Finance | II | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | M/S.ELANGO ELECTRICAL WORKS L1 | E.S.ELECTRICAL L2 |
|---|---|---|---|---|---|
| 1.00 | Removing of 11KV/440V 6 Pole Structure with 250 KVA Transformer - 2 Nos. - Fabrication of 11KV/440V 6 Pole Structure with 250 KVA Transformer - 2 Nos. including basement and cutting, welding, granding of earthing, providing Aluminum painting of six pole yard MS Channels, earthing jumpers complete and painting of Structure, fencing and including replacement of bold nuts with spares complete etc., as per specification. | 1 | Nos | 4,62,000 ₹4,62,000 Lowest | 4,85,000 ₹4,85,000 |
| 2.00 | Supply and connected braided copper wire for AB Switch handle earth. | 3 | Nos | 7,400 ₹22,200 Lowest | 8,000 ₹24,000 |
| 3.00 | Transformer oil leakage arresting along with following work in 250 KVA Transformer Draining out transformer oil to the required level, Top Cover Bushing providing necessary gasket and cone washers and Re fixing same. Replacing new rubberized cork gasket. | 2 | Nos | 22,400 ₹44,800 Lowest | 23,500 ₹47,000 |
| 4.00 | Charges for filtration of 250 KVA transformer oil through Streamline filter unit to improve the Di-electric strength to the optimum value for transformer. | 2 | Nos | 10,900 ₹21,800 Lowest | 11,200 ₹22,400 |
| 5.00 | Charges for cleaning and repainting of 250 KVA Transformer using smoke spray spray painting. | 2 | Nos | 25,200 ₹50,400 Lowest | 26,500 ₹53,000 |
| 6.00 | Charges for testing and issuing test certificates for Di-electric Strength & Acidity of Transformer oil. | 2 | Nos | 4,500 ₹9,000 Lowest | 5,000 ₹10,000 |
| 7.00 | Charges for Secondary Injections Testing of Earth Fault Relays | 2 | Nos | 9,100 ₹18,200 Lowest | 10,000 ₹20,000 |
| 8.00 | Charges for testing of Earth Electrodes and Issuing test report | 10 | Nos | 4,600 ₹46,000 Lowest | 5,000 ₹50,000 |
| 9.00 | Supply of and fixing transformer thermometer
Charges for replacing of silica gel | 2 | Nos | 6,900 ₹13,800 Lowest | 7,200 ₹14,400 |
| 10.00 | Supply of Size : 1 Mtr x 2 Mtr x 2mm Thk, (3.3 kv), Class A IS : 15652 : 2006 New Standard. | 2 | Nos | 6,900 ₹13,800 Lowest | 7,200 ₹14,400 |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
13 Mar 2026, 3:00 pmClosed
Commissioner Kancheepuram Corporation
Kancheepuram city Municipal Corporation, Annai Indira gandhi salai, Kancheepuram
Fabrication of 11 KV / 440V 6 Pole structure with 250KV Transformer - 2Nos and Repairing and Allied works at Vegavathy Booster Station In Kanchipuram Corporation.
2026_MAWS_669210_3
4783/2025/E2
Open Tender
Civil Works
Item Rate
Kancheepuram Corporation
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹15,000
21 Oct 2026
2 Mar 2026
13 Mar 2026
2 Mar 2026
13 Mar 2026
2 Mar 2026
2 Mar 2026 - 13 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Removing of 11KV/440V 6 Pole Structure with 250 KVA Transformer - 2 Nos. - Fabrication of 11KV/440V 6 Pole Structure with 250 KVA Transformer - 2 Nos. including basement and cutting, welding, granding of earthing, providing Aluminum painting of six pole yard MS Channels, earthing jumpers complete and painting of Structure, fencing and including replacement of bold nuts with spares complete etc., as per specification. | 1 | Nos | - | - |
| 2 | Supply and connected braided copper wire for AB Switch handle earth. | 3 | Nos | - | - |
| 3 | Transformer oil leakage arresting along with following work in 250 KVA Transformer Draining out transformer oil to the required level, Top Cover Bushing providing necessary gasket and cone washers and Re fixing same. Replacing new rubberized cork gasket. | 2 | Nos | - | - |
| 4 | Charges for filtration of 250 KVA transformer oil through Streamline filter unit to improve the Di-electric strength to the optimum value for transformer. | 2 | Nos | - | - |
| 5 | Charges for cleaning and repainting of 250 KVA Transformer using smoke spray spray painting. | 2 | Nos | - | - |
| 6 | Charges for testing and issuing test certificates for Di-electric Strength & Acidity of Transformer oil. | 2 | Nos | - | - |
| 7 | Charges for Secondary Injections Testing of Earth Fault Relays | 2 | Nos | - | - |
| 8 | Charges for testing of Earth Electrodes and Issuing test report | 10 | Nos | - | - |
| 9 | Supply of and fixing transformer thermometer
Charges for replacing of silica gel | 2 | Nos | - | - |
| 10 | Supply of Size : 1 Mtr x 2 Mtr x 2mm Thk, (3.3 kv), Class A IS : 15652 : 2006 New Standard. | 2 | Nos | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.18 MB
BOQ_804124.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .