Loading…
Loading…
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
4 May 2026, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of IRSGCC, April 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Non-Compliance to the above will lead to summary rejection of your offer
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one inwhich tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender,orTwo similar works each costing not less than the amount equal to 40% of advertised value of thetender,or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. For details regarding submission of self attested documents/certificates, please refer 'Important instructions to tenderers for open tenders costing more than Rs.50 lakhs available at documents section. Similar nature of work is defined as following, "Works involving wiring/lighting with 240V,1 phase or 415V, 3 phase system with control gear and protection arrangements in residential buildings or service buildings or railway stations /yards or colony/highway lightings " (CEE/MAS Letter No. E.252/1/8/G dated 02.08.2013)" .Tenderers should mandatorily submit Work completion certificate issued by Competent Authority. In case of experience certificate submitted by tenderer for composite works, experience certificate shall clearly specify the executed cost of Electrical work duly certified by Experience Certificate issuing authority Non compliance to above will lead to summary rejection of your offer.
11 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor . For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Proposed improvements for providing Short & Medium term Divyangjan facilities at (NSG1) Tambaram Railway Station and eliminating deficiencies -Electrical arrangements thereof
ME-29-II-1089-2026
ME-29-II-1089-2026
Open
Works - General
90 Days
Chennai, Tamil Nadu
₹0
₹3.6 L
4 May 2026
11 Apr 2026
20 Apr 2026
87 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,77,71,557 | ||
| — | — | — | Above/ 245000.00 Below/P | ||
| a) Excavation of Cable trench in all kinds of soils duly removing all obstructions in the way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. b)Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete in a manner as directed by the Section Engineer in charge at site. | — | 1000.00 | — | — | |
| — | — | — | Above/ 27800.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material atleast 6m away from track centre within railway land by saw cutting/breaker as per site conditions to avoid any damage to nearby site complete in a manner as directed by the Section Engineer in charge at site. | — | 50.00 | — | — | |
| — | — | — | Above/ 283900.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm graded blue metal complete in a manner as directed by the Section Engineer in charge at site. NOTE: i) Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest. ii)Proper compaction of cement concrete shall be ensured as per standard industrial practices. iii)The finished level should match with surface level properly | — | 50.00 | — | — | |
| — | — | — | Above/ 1009400.00 Below/P | ||
| Supply of 4 core 25 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (i)Batch No/Drum No/Lot No/Serial No of the tested cable (ii)LOA/Agreement No as reference with railway mentioned as the consignee/customer. (iii)The WTC should be issued on the official letter head of the manufacturer (OEM).Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. | — | 4900.00 | — | — | |
| — | — | — | Above/ 238000.00 Below/P | ||
| Supply of 4 core 35 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (i)Batch No/Drum No/Lot No/Serial No of the tested cable (ii)LOA/Agreement No as reference with railway mentioned as the consignee/customer. (iii)The WTC should be issued on the official letter head of the manufacturer (OEM). Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. | — | 1000.00 | — | — | |
| — | — | — | Above/ 169950.00 Below/P | ||
| Supply of 4 core 50 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (iv)Batch No/Drum No/Lot No/Serial No of the tested cable (v)LOA/Agreement No as reference with railway mentioned as the consignee/customer. (vi)The WTC should be issued on the official letter head of the manufacturer (OEM). Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. | — | 550.00 | — | — | |
| — | — | — | Above/ 542000.00 Below/P | ||
| Supply of 4 core 95 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (vii)Batch No/Drum No/Lot No/Serial No of the tested cable (viii)LOA/Agreement No as reference with railway mentioned as the consignee/customer. (ix)The WTC should be issued on the official letter head of the manufacturer (OEM). Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. | — | 1000.00 | — | — | |
| — | — | — | Above/ 184600.00 Below/P | ||
| Supply and Laying of 50 mm dia ISI Marked High Density Polyethylene pipes of material grade PE-100 and with Pressure rating of 6.0 P.N conforming to IS: 4984 / 1995 or latest in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. | — | 2600.00 | — | — | |
| — | — | — | Above/ 15500.00 Below/P | ||
| Supply and Laying of 75 mm dia ISI Marked High Density Polyethylene pipes of material grade PE-100 and with Pressure rating of 6.0 P.N conforming to IS: 4984 / 1995 or latest in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. | — | 100.00 | — | — | |
| — | — | — | Above/ 126020.00 Below/P | ||
| Supply, Installation, Testing and Commissioning of the LT Earthling arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or elsewhere, construction of masonry earth pit enclosure, provision of cover etc., complete including supply / leading / laying / burying and concealing of GI strip 32 X 6 mm along with proper sleeve from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site. Note: Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022. | — | 20.00 | — | — | |
| — | — | — | Above/ 1314448.00 Below/P | ||
| Design, manufacture, supply (at site) of 30 metre high mast system of hot tip galvanized complete with head frame assembly, lantern carriage, double drum winch, stainless steel wire rope, suitable control panel, timer switch, twin dome aviation obstructing fittings suitable for high mast including lamps, electrical cable, 9 Nos of 200w high efficient LED flood light fittings with 9 Numbers of Arms and (as per specification enclosed) etc., and other standard accessories as per specification enclosed including integrated power tool with reversible electric motor and foundation bolts manufactures from special steel along with nuts, washers of suitable size of anchor plate and template and erection, testing and commissioning of the above high mast as per specification enclosed on the RCC foundation by using modern engineering practice by crane / derrick system complete as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 1)200w flood light fittings and accessories shall be as per specification enclosed. 2)High Mast Foundation Drawing is enclosed for reference purpose only. Original High Mast Drawing should be submitted by Contractor along with Soil test Report 3)Ten percentage of overall quoted Bid Rate for each High Mast is considered as cost of LED fixtures. Warranty/Guarantee/Deferred Payment clause for LED fixtures will be dealt accordingly as mentioned in Tender Document 4)Remaining Ninety percentage of overall quoted Bid Rate for each High Mast is considered as High Mast cost .Warranty/Guarantee clause for High Mast will be dealt accordingly as mentioned in Tender Document | — | 2.00 | — | — | |
| — | — | — | Above/ 1028176.00 Below/P | ||
| Design, manufacture, supply (at site) of 20 metre high mast system of hot tip galvanized complete with head frame assembly, lantern carriage, double drum winch, stainless steel wire rope, suitable control panel, timer switch, twin dome aviation obstructing fittings suitable for high mast including lamps, electrical cable, 9 Nos of 200w high efficient LED flood light fittings with 9 Numbers of Arms and (as per specification enclosed) etc., and other standard accessories as per specification enclosed including integrated power tool with reversible electric motor and foundation bolts manufactures from special steel along with nuts, washers of suitable size of anchor plate and template and erection, testing and commissioning of the above high mast as per specification enclosed on the RCC foundation by using modern engineering practice by crane / derrick system complete as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 1)200w flood light fittings and accessories shall be as per specification enclosed. 2)High Mast Foundation Drawing is enclosed for reference purpose only. Original High Mast Drawing should be submitted by Contractor along with Soil test Report 3)Ten percentage of overall quoted Bid Rate for each High Mast is considered as cost of LED fixtures. Warranty/Guarantee/Deferred Payment clause for LED fixtures will be dealt accordingly as mentioned in Tender Document 4)Remaining Ninety percentage of overall quoted Bid Rate for each High Mast is considered as High Mast cost .Warranty/Guarantee clause for High Mast will be dealt accordingly as mentioned in Tender Document | — | 2.00 | — | — | |
| — | — | — | Above/ 967920.00 Below/P | ||
| Supply of 5meters long Octagonal Pole totally hot dip galvanized with minimum of 70mm dia at top and130mm dia at the bottom, the plate thickness for pole shall be not less than 3mm, without any intermediate joints, 1 No hot dip galvanized 48mm dia pipe Double Arm arch bracket, Baseplate of size not less than 200 X200 x 12mm with 4 Nos 20mm dia hole, 4 Nos of foundation bolts M16-not less than 600mm long with nuts and washers, two numbers of re-wire able type porcelain fuse base and fuse carrier having a current rating of 16A and voltage not exceeding 650V between lines and conforming to IS:2086 / 1993 or latest and erection, testing and commissioning of the above octagonal pole onto the suitable RCC foundation by using modern engineering practice and in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation shall be as per the standard practice and recommendation of the manufacturer of octagonal pole. 2)The foundation design and drawing along with supporting IS specifications suitable as per site conditions should be submitted for Approval before starting the work. | — | 60.00 | — | — | |
| — | — | — | Above/ 165060.00 Below/P | ||
| a) Supply of 70W LED Street Light fitting as per specification enclosed b) Installation, Testing and commissioning of 70W LED Street light fittings into Octagonal poles including supply connection from nearby junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: The Deferred payment clause is applicable to above scope of work. | — | 140.00 | — | — | |
| — | — | — | Above/ 447120.00 Below/P | ||
| Supply of 4 feet 36W LED Batten light fitting suitable to work on 240V single phase 50 Hz AC supply with lamp and all standard accessories suitable and similar to the specification enclosed and installation, testing and commissioning of the same using suitable mounting arrangements including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper conductor flexible pendant chord conforming to IS:694/1990 or latest in a manner as directed by Section Engineer in charge at site Note: The Deferred payment clause is applicable to above scope of work. | — | 1380.00 | — | — | |
| — | — | — | Above/ 29414.00 Below/P | ||
| Supply, Installation, Testing and commissioning of 36W Recess LED light fitting as per specification enclosed suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangements complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper conductor flexible pendant chord conforming to IS:694/1990 or latest in a manner as directed by Senior Section Engineer in charge at site. Note: The Deferred payment clause is applicable to above scope of work. | — | 14.00 | — | — | |
| — | — | — | Above/ 828750.00 Below/P | ||
| Supply, Installation, Testing and commissioning of 1200mm sweep BLDC Ceiling fan as per specification enclosed onto the buildings ceiling wall or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: The Deferred payment clause is applicable to above scope of work. | — | 250.00 | — | — | |
| — | — | — | Above/ 1141200.00 Below/P | ||
| a) Supply of Heavy Duty BLDC Air circulating fan, 600MM sweep (24 inches), Wall Mounting type suitable to work on 230V, 50 Hz, Ac Supply, with Speed Regulator, Power consumption at speed 1-100 Watts, Power consumption at 3-170 WATT, Rated Speed-1400 RPM, AIR Delivery-717 CUM, (+/- 10%) with Reverse polarity protection, short circuit protection, over voltage protection, blocked blade protection confirming to IS:2997/1994 or latest (Preferable Makes: AIRZON/ATOMBERG/KALTRO/BAJAJ) Proof of purchase and Warranty certificates from Authorized dealer/OEM should be submitted. b) Installation, Testing and commissioning of 600mm sweep BLDC Air circulators onto wall / stanchion / rail post or elsewhere using suitable clamping arrangement made of 40mm X 6mm MS flat and MS plate of size of 300mm X 300mm X 6mm complete in a manner as per standard industrial standards and in a manner as directed by Section Engineer in charge at site. Note: The Deferred payment clause is applicable to above scope of work. | — | 150.00 | — | — | |
| — | — | — | Above/ 3400.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Short point i.e. length upto 3 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 24 below complete with provision of 6A Modular switch conforming to IS: 3854/2023 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 20.00 | — | — | |
| — | — | — | Above/ 11760.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Medium point i.e. length between 3 to 6 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 24 below complete with provision of 6A Modular switch conforming to IS: 3854/2023 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 40.00 | — | — | |
| — | — | — | Above/ 25840.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Long point i.e. length between 6 to 9 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 24 below complete with provision of 6A Modular switch conforming to IS: 3854/2023 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 76.00 | — | — | |
| — | — | — | Above/ 105000.00 Below/P | ||
| Supply and drawing of inside mains using 2 runs of 2.5 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multi-stranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid vide item No:24 below complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 2.5 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 1400.00 | — | — | |
| — | — | — | Above/ 395000.00 Below/P | ||
| Supply and drawing of inside mains using 3 runs of 1.5 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multi-stranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid vide item No:39 below complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 3 runs of 1.5 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 5000.00 | — | — | |
| — | — | — | Above/ 130540.00 Below/P | ||
| Supply and Concealing of 25mm dia rigid PVC conduits along with all accessories and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] | — | 2140.00 | — | — | |
| — | — | — | Above/ 69136.00 Below/P | ||
| Supply and Drawing of earth wire using 1.5 sq.mm fire retardant Low smoke PVC insulated [green colour] unsheathed single copper conductor cables duly along wires vide item No's 22 and light and fan points vide item No.19,20, &21 above or elsewhere complete in a manner as directed by Senior Section Engineer in charge at site. | — | 2384.00 | — | — | |
| — | — | — | Above/ 35140.00 Below/P | ||
| Supply and stringing of overhead mains beneath platform shelters using 5 runs of 16 sq.mm PVC insulated and PVC sheathed multi stranded aluminium conductor cable duly by binding onto insulators of brackets provided vide item No. 27 below complete in a manner as directed by Section Engineer in charge at Site. Note: 1)5 runs of16 sq.mm cable are taken as 1m for unit purpose. 2)The earth wire should be lugged at both ends and has to be terminated in each MS clamp through Nuts and Bolts. | — | 140.00 | — | — | |
| — | — | — | Above/ 6140.00 Below/P | ||
| Supply and fixing of MS brackets, fabricated as per sketch enclosed, for supporting OH wire beneath platform shelters, mounted with 4 Nos. of porcelain vertical reel /shackle insulators and earth stud /bolt, finished with 2 coats of red primer and 1 coat of aluminium paint and complete with fixing arrangements as per drawing enclosed and in a manner as directed by Section Engineer in charges at site | — | 10.00 | — | — | |
| — | — | — | Above/ 150000.00 Below/P | ||
| Supply ,Installation, Testing and commissioning of loop in loop out box of size 170x170x105 mm and made up of SMC ( similar to Sintex catalogue reference No.GS-JB- 1414) and comprising of 1 No. of 6 way 15 amps connector block, 1 No. of 3 plate ceiling rose,1 No of 6A,MCB 'C' curve duly pre wired up to ceiling rose and provision of the same close to light fitting on platform shelter including wiring from junction box to light fitting by using 3 core 1.5 sq.mm multi stranded flexible copper cable complete including all fixing arrangements and other accessories required complete as per site conditions in a manner as directed by the section engineer in charge at site. | — | 200.00 | — | — | |
| — | — | — | Above/ 10400.00 Below/P | ||
| Supply of 3core, 2.5sq.mm pendant cord wire, fireretardant, lowsmoke (FRLS), PVCinsulated, PVC roundsheathed, multistranded copper conductor, suitable for electrical connections. The wire shall conform to IS:694/1990 (latest revision) and be supplied in accordance with industrial standards and as directed by the Section Engineer in charge at site. | — | 200.00 | — | — | |
| — | — | — | Above/ 6440.00 Below/P | ||
| Supply of modular frame plate with matching cover plate suitable for 12 modules duly accommodated onto suitable modular switch board box made of 1.2mm thick GI Sheet complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere and painting etc., complete including fixing ,testing and commissioning of Switches and sockets supplied in above arrangements including all internal wiring connections in a suitable manner as directed by Section engineer in charge at site. Note: - 1 No. 12 Module frame plate with matching cover plate and 1 No. Modular GI box are taken as 1 No for quantity purpose and should match with IS codes with latest amendments. | — | 10.00 | — | — | |
| — | — | — | Above/ 1540.00 Below/P | ||
| Supply of 6A Modular switches conforming to IS: 3854/ 1997 or latest in a manner as directed by Section Engineer-in charge at site. The unit shall be shall be suitable for integration into modular plates/boxes, including internal wiring terminations. | — | 70.00 | — | — | |
| — | — | — | Above/ 1975.00 Below/P | ||
| Supply of 6A Modular sockets conforming to IS: 1293/ 2019 or latest in a manner as directed by Section Engineer-in charge at site. The unit shall be shall be suitable for integration into modular plates/boxes, including internal wiring terminations. | — | 25.00 | — | — | |
| — | — | — | Above/ 1710.00 Below/P | ||
| Supply, Installation, Testing and commissioning of metal junction box(switch board of size 200mmx150mmx50mm fabricated with 16 gauge steel an provided with 3mm thick decolam sheet top, knockout, and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including including all wiring works complete replastering painting etc., complete and in a manner as directed by Senior Section Engineer in charge at site | — | 10.00 | — | — | |
| — | — | — | Above/ 199520.00 Below/P | ||
| Supply of 20A, SP, MCB conforming to IS/IEC:60947 or latest along with IP 30 rated - Metal door Enclosure conforming to IS:8623 or latest suitable for surface and flush mounting and available in CRCA sheet steel, RAL 9003,powder coated with and erection, testing and commissioning of the same using all fixing arrangements along with all incoming and outgoing cabling termination works complete as per directions of Section Engineer in charge at site. | — | 160.00 | — | — | |
| — | — | — | Above/ 553028.00 Below/P | ||
| Supply of vertical, double door, MCCB distribution board conforming to IS: 8623 (latest), made out of powder coat finished 2 mm CRCA sheet steel, having short time with stand current 50 kA per second and complete with electrolyte copper bus bar / earth link / brass neutral bar / DIN rail / cable adopter Boxes etc. 2 No's of 400A, FP, 50kA, MCCB's (confirming to IS: 13947 (part II)) or latest with suitable mechanical and electrical interlocking and adjustable thermal settings, fixed magnetic settings, Earth Fault, Shunt Release etc. along with 400A,FP,Onload Changeover switch conforming to IS/IEC 60947-3 or latest as incomer and (2 No's 250A,FP,36kA + 2 No's 100A,FP,30kA+ 4 Nos 63A ,FP,30kA)(confirming to IS: 13947 (part II) or latest) with adjustable thermal settings, fixed magnetic settings as feeder control and 1 No. of multifunction meter as per the specification enclosed and with RS 485 port and suitable rated CT if required, complete and erection, testing and commissioning of the same including all cable termination at both Incoming and Outgoing sides ,Rotary handles for all MCCB's complete and as per industrial practices , suitable Angle iron frame work and other accessories required complete including all internal wiring connections by using suitable copper wires/bus bars in a manner as directed by Section Engineer in charge at site | — | 2.00 | — | — | |
| — | — | — | Above/ 195000.00 Below/P | ||
| Supply,Erection,testing and commissioning of LED name board(Trilingual) on newly constructed Arch with suitable fixtures made out of ALCO panel sheet as per specification. Note: The Deferred payment clause is applicable to above scope of work. | — | 100.00 | — | — | |
| — | — | — | Above/ 6026240.00 Below/P | ||
| Supply Erection, Installation and testing of Single Sided Wall/Double Sided wall / hanging / floor / pole mounting backlit type LED illuminated, Modular, Changeable Aluminium extruded profile signage / direction board in Full/Half/Semi Parabolic and Elliptical square and multi angle shape, with die moulded internal structural brackets (Nylon/SS) and aluminium extruded heat sink. Suitable size end cap PC/SS304 should be provided with provision of illuminated Logo. The display sheet shall be of un breakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter vision angle shall not be less than 160 degree and visibility not be less than 75%. The approved colour text and graphics shall be printed router cut on monomeric calendered vinyl of 70 micro meter thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq.ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. The work should be executed as per the approved Detailed specifications (STANDARD SIGNAGES AT STATIONS ON INDIAN RAILWAYS -APRIL 2023) Note: The Deferred Payment Clause is applicable to the above scope of work, and the same is enclosed with the tender document. | — | 3520.00 | — | — | |
| — | — | — | Above/ 300080.00 Below/P | ||
| Supply of 5 meters long Octagonal Pole totally hot dip galvanized with minimum of 70mm dia at top and130mm dia at the bottom, the plate thickness for pole shall be not less than 3mm, without any intermediate joints, 1 No hot dip galvanized 48mm dia pipe Single Arm arch bracket, Baseplate of size not less than 200 X200 x 12mm with4 Nos 20mm dia hole, 4 Nos of foundation bolts M16-not less than600mm long with nuts and washers, two numbers of re-wire able type porcelain fuse base and fuse carrier having a current rating of16A and voltage not exceeding 650V between lines and conforming to IS:2086 / 1993 or latest and erection, testing and commissioning of the above octagonal pole onto the suitable RCC foundation by using modern engineering practice and in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation shall be as per the standard practice and recommendation of the manufacturer of octagonal pole. 2)The foundation design and drawing along with supporting IS specifications suitable as per site conditions should be submitted for Approval before starting the work. | — | 20.00 | — | — | |
| — | — | — | Above/ 135000.00 Below/P | ||
| Supply and Concealing of 20mm dia rigid PVC conduits [IVORY colour] along with all accessories and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition/cIamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] | — | 5000.00 | — | — | |
| — | — | — | Above/ 97400.00 Below/P | ||
| Supply, Installation, Testing and commissioning of timer switch assembly comprising of :- a)1 No. timer switch with daily setting similar to L&T catalogue reference J648B1 [FM1 Quartz]. b)1 No. 3 pole 25A power contactor conforming to IS: 13947/P4/1993 or latest, c)1 No. 40A DP [MCB type] isolator conforming to IS: 13947/P3/1993 or latest, d)1 No. Neutral link etc. e)1 No. Earth link etc. f) Suitable rated control fuses all duly pre-wired and mounted on an appropriate sized well- seasoned wooden plank of thickness not less than 12 mm and duly housed into and powder coat finished enclosure of size not less than 300mm X 450mm X 300mm and made of 2mm thick Sheet Steel complete and provision of the same onto the wall or elsewhere using suitable fixing arrangements complete and in a manner as directed by Section Engineer in charge at site. | — | 10.00 | — | — | |
| — | — | — | Above/ 73750.00 Below/P | ||
| Supply of sheet steel enclosed 63A, 30kA, FP, MCCB with adjustable thermal and fixed magnetic settings, shunt trip, rotary handle etc. conforming to IS:13947/P2/1993 or latest and erection, testing and commissioning of the same onto wall, or elsewhere using suitable mounting arrangements including all cable terminations and all other works and items required complete as per site conditions and in a manner as directed by Section Engineer in charge at site . Note: Enclosure shall be suitable for termination of LTUG cable at top and bottom side. | — | 10.00 | — | — | |
| — | — | — | Above/ 137440.00 Below/P | ||
| Supply, Installation, Testing and commissioning of 12 way SPN MCB DB conforming to IS 8623-1 & 3 or latest ,IK-08 protection available in CRCA sheet steel, RAL 9003,powder coated with 100A insulated phase bus-bar/neutral bar/s with shrouds/earth bars/sticking saddles/cement spill protector/color-coded interconnecting wire set/cable ties/blanking plates and circuit identification label along with 1 No's of 32A ,FP,MCB and 8 Nos of 6A,SP,MCB's conforming to IS/IEC:60947 or latest as feeder controls along with Cable adaptor box on to the wall using suitable angle iron frame work and including cutting/chipping and re- plastering and bringing back walls to original condition including painting the walls to original condition complete including all internal wiring connections and terminations as per industrial practices in a manner as directed by Senior Section Engineer in charge at site | — | 20.00 | — | — | |
| — | — | — | Above/ 335820.00 Below/P | ||
| Supply, Installation, Testing and commissioning of 8 way SPN MCB DB conforming to IS 8623-1 & 3 or latest ,IK-08 protection available in CRCA sheet steel, RAL 9003,powder coated with 100A insulated phase bus-bar/neutral bar/s with shrouds/earth bars/sticking saddles/cement spill protector/color-coded interconnecting wire set/cable ties/blanking plates and circuit identification label along with 1 No's of 32A ,FP,MCB and 4 Nos of 10A,SP,MCB's conforming to IS/IEC:60947 or latest as feeder controls along with Cable adaptor box on to the wall using suitable angle iron frame work and including cutting/chipping and re- plastering and bringing back walls to original condition including painting the walls to original condition complete including all internal wiring connections and terminations as per industrial practices in a manner as directed by Senior Section Engineer in charge at site. | — | 60.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
36WLEDTubelightspecification.pdf
ATTACHMENT
BLDCCeilingFanSpecification.pdf
ATTACHMENT
Checklist.pdf
ATTACHMENT
DeferredPaymentclause.pdf
ATTACHMENT
EarthingType1032.pdf
ATTACHMENT
Earthing.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
GCCACS1.pdf
ATTACHMENT
GCCACS2.pdf
ATTACHMENT
GCCACS3.pdf
ATTACHMENT
IRSGCCACS4.pdf
ATTACHMENT
IRSGCCACS5.pdf
ATTACHMENT
IRSGCCACS6.pdf
ATTACHMENT
IRSGCCACS7.pdf
ATTACHMENT
IRSGCCACS8.pdf
ATTACHMENT
IRSGCCACS9.pdf
ATTACHMENT
IRSGCCACS10.pdf
ATTACHMENT
GeneralinstructionstoTenderers.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
SpecialconditionsofContractElectrical.pdf
ATTACHMENT
IRSGCCACS11.pdf
ATTACHMENT
HighMastDrawing.pdf
ATTACHMENT
HighMastSpecification.pdf
ATTACHMENT
LEDspecification-SELSpecPower2-2015.pdf
ATTACHMENT
LTSwitchboardSpecification.pdf
ATTACHMENT
MCBDrawing.pdf
ATTACHMENT
MFMSpec.pdf
ATTACHMENT
MSBracketsDiagram.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Undertaking.pdf
ATTACHMENT
SpecificationforlayingUndergroundcable.pdf
ATTACHMENT
specificationforwiringandrewiring.pdf
ATTACHMENT
StationNameBoardSpecification.pdf
ATTACHMENT
SignagespecificationPart1.pdf
ATTACHMENT
SignagespecificationPart2.pdf
ATTACHMENT
SignagespecificationPart3.pdf
ATTACHMENT
SignagespecificationPart4.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .