| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 CrAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹18.4 Cr+₹3.2 Cr (21.0%)Admitted-Finance SINGHI HOUSE RAJA MAIDAM ROAD JORHAT 785001 ASSAM INDIA | JORHAT | JORHAT | ASSAM | 785001 | L2 | Admitted-Finance | |
| 3 | L3₹20.7 Cr+₹5.5 Cr (36.2%)Admitted-Finance A T ROAD EVERLITE HOUSE PANITOLA LAIPULI TINSUKIA ASSAM 786183 | TINSUKIA | ASSAM | 786183 | L3 | Admitted-Finance | |
| 4 | L4₹21.0 Cr+₹5.8 Cr (38.3%)Admitted-Finance 1ST FLOOR 29A SESHAADHRI NILAY D NEOG PATH BEHIND DONA PLANET ANANDA NAGAR G S ROAD GUWAHATI ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | L4 | Admitted-Finance | |
| 5 | Rejected-Technical 01 BOKAKHAT UDAYNAGAR GOLAGHAT ASSAM 785612 | GOLAGHAT | ASSAM | 785612 | - | Rejected-Technical Pl refer Techno Commercial Evaluation Report |
| Sl No | Description | Qty | Unit | NORTH EASTERN ENGINEERS L1 | Singhi InfraPower Projects Pvt. Ltd. L2 | Power Tools and Engineering L4 | M/s. Everlite Engineering Industries L3 |
|---|---|---|---|---|---|---|---|
| 10.00Supply | |||||||
| 10.01 | Supply of 11kV (UE) Grade, 3C x 185 Sqmm HV Power Cable
Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per technical specification of cables attached : | 15,000 | M | 1,287 ₹1,93,05,000 Lowest | 1,500 ₹2,25,00,000 | 1,560.12 ₹2,34,01,800 | 1,830 ₹2,74,50,000 |
| 10.02 | Supply of 1.1 kV Grade, 3.5C X 300 sq mm LV Power Cable
Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable s per technical specification of cables attached : | 8,000 | M | 1,143 ₹91,44,000 Lowest | 1,330 ₹1,06,40,000 | 1,390.86 ₹1,11,26,880 | 1,640 ₹1,31,20,000 |
| 10.03 | Supply of 1.1 kV Grade, 3.5C X 240 sq mm LV Power Cable
Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per technical specification of cables attached : | 2,000 | M | 927 ₹18,54,000 Lowest | 1,100 ₹22,00,000 | 1,120.97 ₹22,41,940 | 1,345 ₹26,90,000 |
| 10.04 | Supply of 1.1 kV Grade, 3.5C X 50 sq mm LV Power Cable
Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the data sheet of cables: | 5,000 | M | 234 ₹11,70,000 Lowest | 300 ₹15,00,000 | 282.18 ₹14,10,900 | 370 ₹18,50,000 |
| 10.05 | Supply of 1.1 kV Grade, 14C x 2.5 sq mm Control Cable
CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed control cable as per the attached data sheet of cables | 12,000 | M | 381 ₹45,72,000 Lowest | 400 ₹48,00,000 | 463.88 ₹55,66,560 | 480 ₹57,60,000 |
| 10.06 | Supply of 1.1 kV Grade, 7C x 2.5 sq mm Control Cable
CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed control cable as per the attached data sheet of cables | 3,000 | M | 207 ₹6,21,000 Lowest | 220 ₹6,60,000 | 251.97 ₹7,55,910 | 260 ₹7,80,000 |
| 10.07 | Supply of 1.1 kV Grade, 3C x 4 sq mm LV Power Cable
CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the attached data sheet of cables | 1,000 | M | 132 ₹1,32,000 Lowest | 160 ₹1,60,000 | 176.67 ₹1,76,670 | 195 ₹1,95,000 |
| 10.08 | Supply of 1.1 kV Grade, 3C x 2.5 sq mm LV Power Cable
CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the attached data sheet of cables | 5,000 | M | 108 ₹5,40,000 Lowest | 130 ₹6,50,000 | 130.34 ₹6,51,700 | 140 ₹7,00,000 |
| 10.09 | Supply of Weather Proof Cable Gland for 11kV (UE) Grade 3C x 185 Sqmm HV Power Cable
Double compression Nickel plated brass cable gland suitable for Aluminium conductor, Armoured HV Power cables, 11kV (UE) Grade 3C x 185 Sqmm HV Power Cable | 20 | NOS | 990 ₹19,800 Lowest | 4,280 ₹85,600 | 1,440.35 ₹28,807 | 1,800 ₹36,000 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
19 Jul 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Kaveri Hazarika 9435703123
Numaligarh Refinery Limited
Construction power facilities for Rajabari area in and around NRL Site for NREP
2022_NRL_696062_1
OC10000477/KAV
Open Tender
Miscellaneous Works
Works
180 days
Numaligarh Refinery Limited
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1 L
Yes
23 Aug 2022
21 Jun 2022
20 Jul 2022
21 Jun 2022
19 Jul 2022
1 Jul 2022
120 days
Amount
Supply
Supply of 11kV (UE) Grade, 3C x 185 Sqmm HV Power Cable Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per technical specification of cables attached :
Supply of 1.1 kV Grade, 3.5C X 300 sq mm LV Power Cable Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable s per technical specification of cables attached :
Supply of 1.1 kV Grade, 3.5C X 240 sq mm LV Power Cable Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per technical specification of cables attached :
Supply of 1.1 kV Grade, 3.5C X 50 sq mm LV Power Cable Al conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the data sheet of cables:
Supply of 1.1 kV Grade, 14C x 2.5 sq mm Control Cable CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed control cable as per the attached data sheet of cables
Supply of 1.1 kV Grade, 7C x 2.5 sq mm Control Cable CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed control cable as per the attached data sheet of cables
Supply of 1.1 kV Grade, 3C x 4 sq mm LV Power Cable CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the attached data sheet of cables
Supply of 1.1 kV Grade, 3C x 2.5 sq mm LV Power Cable CU conductor, XLPE insulated, Extruded PVC inner sheathed, armoured and FRLS PVC outer sheathed power cable as per the attached data sheet of cables
Supply of Weather Proof Cable Gland for 11kV (UE) Grade 3C x 185 Sqmm HV Power Cable Double compression Nickel plated brass cable gland suitable for Aluminium conductor, Armoured HV Power cables, 11kV (UE) Grade 3C x 185 Sqmm HV Power Cable
Supply of Weather Proof Cable Gland for 1.1kV Grade 3.5C x 300 Sqmm LV Power Cable Double compression Nickel plated brass cable gland suitable for Aluminium conductor, Armoured Power cables, 1.1kV Grade 3.5C x 300 Sqmm LV Power Cable
Supply of Weather Proof Cable Gland for 1.1kV Grade 3.5C x 240 Sqmm LV Power Cable Double compression Nickel plated brass cable gland suitable for Aluminium conductor, Armoured Power cables, 1.1kV Grade 3.5C x 240 Sqmm LV Power Cable
Supply of Weather Proof Cable Gland for 1.1kV Grade 3.5C x 50 Sqmm LV Power Cable Double compression Nickel plated brass cable gland suitable for Aluminium conductor, Armoured Power cables, 1.1kV Grade 3.5C x 50 Sqmm LV Power Cable
Supply of Weather Proof Cable Gland for 1.1kV Grade 14C x 2.5 Sqmm Control Cable Double compression Nickel plated brass cable gland suitable for Copper conductor, Armoured Control cables, 1.1kV Grade 14C x 2.5 Sqmm
Supply of Weather Proof Cable Gland for 1.1kV Grade 7C x 2.5 Sqmm Control Cable Double compression Nickel plated brass cable gland suitable for Copper conductor, Armoured Control cables, 1.1kV Grade 7C x 2.5 Sqmm
Supply of Weather Proof Cable Gland for 1.1kV Grade 4C x 16 Sqmm LV Power Cable Double compression Nickel plated brass cable gland suitable for Copper conductor, Armoured LV Power cables, 1.1kV Grade 4C x 16 Sqmm
Supply of Weather Proof Cable Gland for 1.1kV Grade 3C x 4 Sqmm LV Power Cable Double compression Nickel plated brass cable gland suitable for Copper conductor, Armoured LV Power cables, 1.1kV Grade 3C x 4 Sqmm
Supply of Weather Proof Cable Gland for 1.1kV Grade 3C x 2.5 Sqmm LV Power Cable Double compression Nickel plated brass cable gland suitable for Copper conductor, Armoured LV Power cables, 1.1kV Grade 3C x 2.5 Sqmm
Supply of Flood Lights, 200W,IP 67 Supply of 200W LED flood light with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 equivalent to Havells product code JETAVALOUR FL200WLED757MODNBLTG or equivalent as per direction of EIC
Supply of 300 mm Width Ladder Type GI Cable Tray Straight Element. 300mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Supply of 50 x 6 mm GI earth strip
Supply of 8 SWG GI Wire
Supply of 10 SWG GI Wire
Supply of of class B, GI pipes/ sleeves, 150 mm dia
Supply of HT straight through cable jointing kits -heat shrinkable, Unearthed grade,(Outdoor), lugs and accessories, including all materials and accessories etc complete as per requirement for 3 Core armoured AL cables,11 kV,XLPE (UE), 120-185 sqmm . (make Raychem or equivalent
Supply of HT straight through cable jointing kits -heat shrinkable, Unearthed grade , (Outdoor) , lugs and accessories, including all materials and accessories etc complete as per requirement for 3 Core armoured AL cables,11 kV, XLPE (UE), 240-400 sqmm
Supply of indoor type HT cable end termination kit. Including Supply of heat shrinkable Unearthed grade H.V. termination kits (Indoor), lugs and accessories, including all materials and accessories etc. complete as per requirement for 3 Core armoured AL cables 11 kV, XLPE (UE), 120-185 sqmm. (make Raychem or equivalent)"
Supply of indoor type HT cable end termination kit. Including Supply of heat shrinkable Unearthed grade H.V. termination kits (Indoor), lugs and accessories, including all materials and accessories etc. complete as per requirement for 3 Core armoured AL cables 11 kV, XLPE (UE), 240-400 sqmm. (make Raychem or equivalent)"
Supply of indoor type HT cable end termination kit. Including Supply of heat shrinkable Unearthed grade H.V. termination kits (Indoor), lugs and accessories, including all materials and accessories etc. complete as per requirement for 3 Core armoured AL cables 11 kV, XLPE (UE), 120-185 sqmm. (make Raychem or equivalent)"
Supply of LT straight through heat shrinkable outdoor cable jointfor armoured 3.5/4 core cable, 1100V, PVC insulated, with Al conductor -including supply of termination kit, lugs, all materials and accessories etc complete as required. Size 3.5/4 Core 185 to 300 sqmm
Supply of Heat shrinkable straight through jointing kit for Cable size:3.5CX25 Sqmm to 3.5CX50 SqmmCable type:PVC insulated Al conductor Voltage grade:1100V Conforms to:IS13573Type test passed as per IS.Make: Raychem or equivalent
Supply of Heat shrinkable straight through jointing kit for Cable size: 7CX2.5 Sqmm to 14CX2.5 SqmmCable type:PVC insulated Al conductor Voltage grade:1100V Conforms to:IS13573Type test passed as per IS.Make: Raychem or equivalent
Supply - Mandatory Spares for Outdoor Type 11 kV Switchgear Mandatory spares parts / items for outdoor type 11KV HV Switchgear for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
Supply - Mandatory Spares for Package Compact substation Mandatory spares parts / items for 1600kVA Compact Substation for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
Supply - Mandatory Spares for Outdoor Type 415V MV Switchgear Mandatory spares parts / items for Outdoor type 415V MV Switchgear for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
Supply - Mandatory Spares for Feeder Pillar Mandatory spares parts / items for Outdoor type 400A/250A/160A Feeder Pillar Box for trouble free operation for period of four (4) years (List of Mandatory spares with quantity of each item to be provided by Bidder)
Supply of HVBT tape (100 mm width High Voltage Busbar Insulation heat shrikable tape)
Supply, transportation up to erection at site, Installation, Earthing, Testing, Operational and Functional checking, Relay settings, calibration of relays/meters (if any) and commissioning of Switchboards, assembly, positioning in place, mounting and wiring of loose supplied part by equipment vendor, interconnection of shipping sections and requisite interpanel wiring between shipping sections as per attached SLD , including supply of all wiring materials, drilling of gland plates for cable gland fixing, plugging of unused cable entries etc. Including supply and application of grouting materials, foundation bolts, plugs for unused cable entries, hardware materials, touch up painting as required, wiring material & copper lugs for wiring. Complete with labour & materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. Also any assistance required to Client for CEA approval shall be in Contractor's scope.
Supply, transportation up to erection site, Installation, earthing (all internal earthing and connection of internal earth with outside grid) testing and commissioning of outdoor type following Compact Substations (CSS) consisting of HV VCB (RMU) and MV distribution boards, transformers, power factor improvement capacitors, misc. electrical panels including all labour and materials, as per attached SLD with this tender and directions of Engineer-in-Charge. Also any assistance required to Client for CEA approval shall be in Contractor's scope. Compact Substation with 11kV/433V, 1600KVA, Transformer with outgoings and cable terminations as per SLD. Supply shall include commissioning spares as required. Package substation shall consist of : ● 630A, 11kV, 3 phase,50Hz, 25kA for 1 second, VCB Breaker Panel consist of 3 nos VCB. (RMU-1 number VCB for incomer and 2 numbers VCB for outgoing feeders as loop in-loop out). ● 11kV/433V, 3 Phase, Dyn11, OCTC with tapping range of ±5% in steps of 2.5%, ONAN type Energy efficiency Level 2 (minimum) as per IS 1180 OR Dry type cast resin natural air cooled (AN) Transformer with all fittings & accessories. ●415V, 3 Phase, 50Hz, 50kA for 1 second, MV Switchboard with ACB incomer & MCCB having O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection for outgoing feeders. ● KWH Meters in incomer & all outgoing feeders of MV switchboard ● All lighting and lighting distribution inside Package substation ● APFC panel with required protection. ● All protection & metering as required. ● All internal earthing and connection of internal earth with outside grid. CSS to be numbered as CSS-01,CSS-02 and CSS-03
Supply, Installation,Testing and commissioning - 630A Feeder Pillar Feeder pillars with Thermoplastic Polycarbonate insulated enclosure materials with enclosure protection of IP55 and with canopy, suitable for Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529, protection class II, totally insulated, having internally embedded gasket, flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11. Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection ● 630A MCCB as Incomer Breaker. ● 2 Nos 400A MCCB, 2 Nos 250 A MCCB, 4 Nos 63A MCCB, 2 Nos 32A MCCB(timer controlled) outgoing feeders ● Supply shall include commissioning spares as required (List shall be provided by bidder) Feeder pillar panels shall comply the following requirement : # The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same. # With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2. # The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily : ● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view. # Routine Test Certificate should be from OEM only and submit according to IEC 61439-1 & 2 along with Panel.
Supply, Installation, Testing and commissioning - 400A Feeder Pillar Feeder pillars with Thermoplastic Polycarbonate insulated enclosure materials with enclosure protection of IP55 and with canopy, suitable for Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529, protection class II, totally insulated, having internally embedded gasket, flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11. Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection ● 400A MCCB as Incomer Breaker. ● 2 Nos 160A MCCB, 3 Nos 125A MCCB, 4 Nos 63A MCCB, 2 Nos 32A MCCB(timer controlled) outgoing feeders ● Supply shall include commissioning spares as required (List shall be provided by bidder) Feeder pillar panels shall comply the following requirement : # The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same. # With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2. # The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily : ● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view. # Routine Test Certificate should be from OEM only and submit according to IEC 61439-1 & 2 along with Panel.
Supply, Installation, Testing and commissioning - 250A Feeder Pillar Feeder pillars with Thermoplastic Polycarbonate insulated enclosure materials with enclosure protection of IP55 and with canopy, suitable for Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529, protection class II, totally insulated, having internally embedded gasket, flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11. Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection. ● 250A MCCB as Incomer Breaker. ● 2 Nos 160A MCCB, 2 Nos 125A MCCB, 3 Nos 63A MCCB, 2 Nos 32A MCCB(timer controlled) outgoing feeders ● Supply shall include commissioning spares as required (List shall be provided by bidder) Feeder pillar panels shall comply the following requirement : # The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same. # With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2. # The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily : ● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view. # Routine Test Certificate should be from OEM only and submit according to IEC 61439-1 & 2 along with Panel.
Supply, Installation, Testing and commissioning - 160A Feeder Pillar Feeder pillars with Thermoplastic Polycarbonate insulated enclosure materials with enclosure protection of IP55 and with canopy, suitable for Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529, protection class II, totally insulated, having internally embedded gasket, flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11. Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection. ● 160A MCCB as Incomer Breaker. ● 4 Nos 125A MCCB, 3 Nos 63A MCCB, 2 Nos 32A MCCB (timer controlled) outgoing feeders ● Supply shall include commissioning spares as required (List shall be provided by bidder) Feeder pillar panels shall comply the following requirement : # The Thermoplastic enclosure manufacturer and the Panel manufacturer should be same. # With the OEM authorization, they should confirm that they will make the FRP / thermoplastic Panels & the Guarantee, Warranty; Servicing should be taken care by them only. # Feeder Pillar Panels should be in accordance with IEC 61439-1 & 2. # The OEM of board / panel shall submit “Type test report” (ASTA certification' by CPRI) for the offered board made of FRP OR Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following type tests performed and passed out satisfactorily : ● Temperature Rise. ● Dielectric Properties. ● Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. ● Degree of Protection. ● Clearance & Creepage Distance. ● Mechanical Operation ● Effectiveness of Protective Circuits ● The Panels should have padlock facility for security point of view. # Routine Test Certificate should be from OEM only and submit according to IEC 61439-1 & 2 along with Panel.
Supply , Installation,Testing and comissionig of wheel mounted polycarbonate distribution board Incomer - 125A FP 100mA RCCB + 125A FP 10kA MCB – 1 No On/Off Indication Lamp – Each 1 no Outgoing – 63A FP 10kA MCB – 1 No 63A 5Pin IP67 Plug & Socket – 1 No32A FP 10kA MCB – 1 No 32A 5Pin IP67 Plug & Socket – 1 No 25A DP 10kA MCB – 2 Nos 25A(32A) 3Pin IP67 Plug & Socket – 2 Nos for technical specification refer Annexure-A for SLD refer Annexure-B for drawing refer annexure-C of make Hensel or equivalent
Supply, Installation, Testing and Commissioning of wheel mounted polycarbonate distribution board Incomer - 63A FP 100mA RCCB + 63A FP 10kA MCB – 1 No On/Off Indication Lamp – Each 1 no Outgoing – 32A FP 10kA MCB – 2 Nos 32A 5Pin IP67 Plug & Socket – 2 Nos 16A DP 10kA MCB – 1 No 16/20A 3Pin IP67 Plug & Socket – 1 No 25A DP 10kA MCB – 1 No 25A(32A) 3Pin IP67 Plug & Socket – 1 No for technical specification refer Annexure-A for SLD refer Annexure-D for drawing refer annexure-E of make Hensel or equivalent
Supply, Installation,Testing Commissioning of polycarbonate DB Incomer - 25A FP 100mA RCCB – 1 No On/Off Indication Lamp – Each 1 no Outgoing – 16A SP 10kA MCB – 3 Nos 16/20A 3Pin IP67 Plug & Socket – 3 Nos for technical specification refer Annexure-A of make Hensel or equivalent
Supply and installation of CO2 Fire Extinguishers (5 kg) including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Supply and installation of First Aid Boxes including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Supply and installation of Sand buckets(3 numbers) with stand and sand including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Supply and installation of Shock hazard charts printing with three (3) language ie. English, Hindi & Assamese complete with aluminium frame and glass including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Supply and installation of Enamelled caution boards printing with three (3) language ie. English, Hindi & Assamese including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable latest Indian standards, CEA regulations and as per directions of Engineer-in-charge.
Supply and laying of 1000 mm wide safety insulating Rubber Mat suitable for 11 kV System Voltage required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable latest Indian or International standards, CEA regulations and as per directions of Engineer-in-charge
Supply and laying of 1000 mm wide safety insulating Rubber Mat suitable for 415V System Voltage required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable latest Indian or International standards, CEA regulations and as per directions of Engineer-in-charge
Supply and installation of cable markers Supply and installation of cable markers for buried HV/MV cable at the interval of 30M, at every bend & at every cable joint location, supply of associated materials including engraving "BURIED ELECTRIC CABLES HT/LT" complete with support and foundation, painting as per approved drawing, specification of this tender and directions of Engineer-in-charge. This includes supply & installation of all necessary consumables, GI hardwares.
Supply, Installation, connection of 40 mm dia & 3000 mm long GI ROD electrode. Supply, Installation, connection to main earth grid, testing and commissioning of earth pits in hard soil area complete with 40 mm dia & 3000 mm long GI ROD electrode, GI test link, concrete chamber with Cast Iron (CI) cover as inspection chamber including excavation of earth pit. supply of civil material, back filling, numbering of pits, including all labour and materials as per standard drawing complete as per specification of this tender and directions of Engineer-in-charge.
Termination of cable having outer diameter upto 40mm; CABLE TERMINATION : (Common specification for this & same category of items below) :Termination of armoured power cables (Typically PVC/XLPE insulated up to 1100 V grade). Job includes earthing the cable armour, connecting to the terminals, supply and marking of upto 1100V 3/3.5/ 4 core of size wire number ferrules/ cable tags (ss/ aluminium/ lead strip minimum 2 mm thick and 20 mm wide at the termination point), drilling in equipment,removal, cutting , fixing of gland plate, fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, consumable items like Crimping paste, insulation Tapes, Including Supply of cable WP GLAND and LUGS etc complete, including all labour and materials complete, as per approved drawings, specifications of this tender and directions of EIC.
Termination of cable having outer diameter above 40mm; CABLE TERMINATION : (Common specification for this & same category of items below) :Termination of armoured power cables (Typically PVC/XLPE insulated up to 1100 V grade). Job includes earthing the cable armour, connecting to the terminals, supply and marking of upto 1100V 3/3.5/ 4 core of size wire number ferrules/ cable tags (ss/ aluminium/ lead strip minimum 2 mm thick and 20 mm wide at the termination point), drilling in equipment, removal, cutting, fixing of gland plate, fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, consumable items like Crimping paste, insulation Tapes, Incliding Supply of cable WP GLAND and LUGS etc complete, including all labour and materials complete, as per approved drawings, specifications of this tender and directions of EIC.
Supply and spreading of approved fine river sand in cable trenches including all labour and materials complete as per specifications and direction of Engineer- in-charge.
Supply and laying of approved second class bricks of thickness 3" in cable trenches for cable protection including all labour and materials complete as per specifications and direction of Engineer- in-charge.(Actual area of laid brick surfaces shall be measured)
Lettering and Stenciling of 32 mm height including supply of approved colour of Paint/Paints , painting of tag number of Electrical equipments as specified in specification & by Engineer -In-Charge. Supply of various types of paints, primers, preparation of surfaces by manual, hand tool cleaning, power tool cleaning and application of primer and finish paints for equipments surfaces/concrete surfaces, identification (Equipment name) lettering, stenciling,colour bands, colour coding etc as specified including rubdown and touch up of shop primer wherever required, providing scaffolding at all elevations, various locations, labour, materials, tools & tackles, consumables, safety, PPE's, supervision, etc. to complete the work in all respect as per the Painting Specifications drawings, and direction & full satisfaction of owner's/engineer in charge for all types of equipment as specified in the Painting specifications:
Lettering and Stenciling of 50 mm height including supply of approved colour of Paint/Paints , painting of tag number of Electrical equipments as specified in specification & by Engineer -In-Charge. Supply of various types of paints, primers, preparation of surfaces by manual, hand tool cleaning, power tool cleaning and application of primer and finish paints for equipments surfaces/concrete surfaces, identification (Equipment name) lettering, stenciling,colour bands, colour coding etc as specified including rubdown and touch up of shop primer wherever required, providing scaffolding at all elevations, various locations, labour, materials, tools & tackles, consumables, safety, PPE's, supervision, etc. to complete the work in all respect as per the Painting Specifications drawings, and direction & full satisfaction of owner's/engineer in charge for all types of equipment as specified in the Painting specifications:
Supply, Fabrication and installation of various sizes steel for supports, brackets for miscellaneous electrical equipment, base frames, support for switchgear, supports for outdoor lighting fixtures, hangers, risers, clamps etc. for miscellaneous electrical equipment / items, cable and cable tray supports with rolled MS sections, pipes, plates, strip etc., including shot blasting, welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc. Including surface finish, painting with one coat of 60 micron DFT of inorganic zinc silicate primer, 1 coat of 100 micron Two pack Epoxy HB Poly amide cured, including breaking walls, floors etc. for structures as required, including supply of all G.I hardware materials, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-In-charge. Any item weighing up to 1 kg or less shall neither be measured nor paid.
Providing & fixing PVC pipe of 4 kg / sq cm pressure of Supreme or Finolex make for rain water including all accessories and fixing materials, tools, tackles & labors etc. complete as directed For 160 mm dia
SITC of PSC Poles 7.5 m length
SITC of 11kV 4 pole ,4 way structure with 8.5 M PSC poles , Insulators (polymer 11 KV grade) , Lightning Aresstors sets(polymer) , Drop out fuse sets,GOAB switches,ISMC channels,conductor, stay sets etc and all aother accessories as required as per site condition.
SITC of 500kVA Outdoor type 11/0.433 KV copper wound distribution transformer bushing at HT side and Cable entry at LT side as per technical specification attached with the tender
Supply & Installation of IP 66 Thermoplastic Polycarbonate PC - GFS Black Colour(RAL9011) Junction Box with pre molded knockout for cable entries from five direction and which is dust proof, water corrosion proof, insulated and shock proof & internally embedded gasket technology. Lid fasteners shall have captive type thermoplastic screws. The junction box shall fulfill the following standards IEC 60670-22 : Particular requirements for connecting boxes andenclosures. IEC 60695 # 2 # 11 : Flame # retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 degree of protection. Weatherproof: UV resistant due to solar radiation, protected against rain water, temperature resistant, Impact Resistant : IK 09 ( 10 joule ) Halogen Free in accordance with IEC 60 754-2 Size - ( 205 x 255 x 112)mm (Cat No DK2525G) (including terminal) Internal #25sq mm 5 Pole Terminal with 1 no 6A SP MCB Gland #2 Nos M25 SWA IP66 insulated double compression cable gland made of high quality nickel plated brass (Part no GSC 25) and direction of Engineer-in-Charge
Service Part
Laying of cables with outer diameter upto 40 mm. LAYING CABLE : Laying, testing and commissioning of following sizes LV, MV & HV Cables and sealed properly of upto /3.5/ 4 of size PVC caps in designated cable route (in built-up readymade trenches; overhead cable trays; pull through pipes; exposed on wall/ beam/ rakes/ trusses tie/ beam/ embedded in floor or buried directly underground; or through G.I.pipe ). Cables shall be PVC/XLPE insulated; PVC Sheathed; FRLS armoured Aluminium/ Copper Cables or similar types as per IS:1554 (PART-I), IS 7098 PART I & IS 1225-latest version.; Unit rates quoted for installation of cables shall be same irrespective of route and method of laying. The item shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways etc. and supply and installation of saddles, spacers and nylon chord for tying as required, stainless steel/aluminium/lead strip identification tags at strategic points/ every 50 meter intervals, aluminium clamps. etc. The straight through Jointings/ tying of upto 1100V 3/3.5/ 4 core of size armour in the cables should be avoided/ minimised. (Structural steel, tray, pipe, excavation, sand and bricks shall be paid under separate item of BOQ). Item includes transportation from store/yard to site at the place of installation, unpacking, including all labour and materials.Empty drums and excess cable to be rerolled and transported back to desigated store/yard. The designated store/yard will be located inside NRL refinery site or NRMT.
Laying of cables with outer diameter above 40 mm. LAYING CABLE : (Common specification for this & same category of items below) : Laying, testing and commissioning of following sizes LV, MV & HV Cables and sealed properly of upto /3.5/ 4 of size PVC caps in designated cable route (in built-up readymade trenches; overhead cable trays; pull through pipes; exposed on wall/ beam/ rakes/ trusses tie/ beam/ embedded in floor or buried directly underground; or through G.I.pipe ). Cables shall be PVC/XLPE insulated; PVC Sheathed; FRLS armoured Aluminium/ Copper Cables or similar types as per IS:1554 (PART-I), IS 7098 PART I & IS 1225-latest version.; Unit rates quoted for installation of cables shall be same irrespective of route and method of laying. The item shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways etc. and supply and installation of saddles, spacers and nylon chord for tying as required, stainless steel/aluminium/lead strip identification tags at strategic points/ every 50 meter intervals, aluminium clamps. etc. The straight through Jointings/ tying of upto 1100V 3/3.5/ 4 core of size armour in the cables should be avoided/ minimised. (Structural steel, tray, pipe, excavation, sand and bricks shall be paid under separate item of BOQ). Item includes transportation from store/yard to site at the place of installation, unpacking, including all labour and materials.Empty drums and excess cable to be rerolled and transported back to desigated store/yard. The designated store/yard will be located inside NRL refinery site or NRMT.
Installation of 300 mm Width Ladder Type GI Cable Tray Straight Element. 300mm width,(100mm side rail, 3 meter long) 3 mm thick, spacing of rungs at 250 mm, Galvanised Steel & ladder type trays, complete with necessary coupler plates, bonding Jumpers for earthing (8 SWG GI wire of 500mm length, with 2nos of crimpped Aluminium Lug with 2 nos M8 X 25 suitable for cable tray connection), accessories & hardwares (All hardware such as bolts, nuts, screws, washers will be stainless steel of SS-304 grade)
Laying, clamping and connecting of 50 x 6 mm GI earth strip for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
Laying, clamping and connecting of 8/10 SWG GI Wire for main earth grid/earthing network under ground, along structure, cable trays, racks walls, roofs, in trench etc. including excavation and filling of earth, chipping and remaking of concrete surface, supply and fixing of GI clamps, Supply of fixing GI fastners at earth plate & at equipment end wherever required. Supply & applying bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints. Earthing to be carreid out as per IS:3043 It also includes any modification work because of fouling with under ground/above ground piping.
Fabrication and installation of of 150 mm dia, class B, GI pipes/ sleeves for cable protection, fixed on steel, concrete or similar structure, in trenches, ready to be buried in concrete including cutting, bending, grinding, threading and similar works, supply & fixing of required GI fastners, clamps, small iron structures, spacers, cleats, plug, bushings, sealing compound/ material etc., cutting and remaking of concrete surface including supply of civil material, all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge.
Grubbing, scrubbing & clearing the areas, removal of roots/boulders,breaking clods, making up the hollow produced by removal of roots/boulders with available earth, clearing the site of all objectionable/unserviceable materials by means of manual or mechanical excavation as per directions of Engineer-in-Charge. The cutting and stripping work shall be done to an average depth of 300 mm and the surface rough-levelled for subsequent works. Including loading, transport, unloading and disposal of the unserviceable material at designated areas within the plant boundary and leveling the same.
Making horizontal bore under the WBM etc. of the roads: making horizontal bore under the WBM of the roads etc., manually or by machinefor laying upto 100mmNB GI/RCC pipes,excavating the side approach to facilitate boring,backfilling the same after completion of works including supply of tools,tackles and equipments etc. personal protective equipments to complete the job as required ,excluding the supply of GI pipes and as per direction Engineer-in-Charge.
Panel etc. install: Weight upto 50 kg PANEL ETC. INSTALL: (Common specification for this & same category of items below) : E : Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, motors, misc. electrical panels and equipments etc., including transportation from store/yard to site at the place of installation, lifting the panels and equipment by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures,anchoring, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. The channel supports on cable trench required to position the panels etc. shall be measured and paid separately.
Panel etc. install: Weight more than 50 Kg to 100 kg PANEL ETC. INSTALL: (Common specification for this & same category of items below) : E : Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, motors, misc. electrical panels and equipment etc., including transportation from store/yard to site at the place of installation, lifting the panels and equipment by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures,anchoring, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. The channel supports on cable trench required to position the panels etc. shall be measured and paid separately.
Panel etc. install: Weight more than 100Kg to 500 kg PANEL ETC. INSTALL: (Common specification for this & same category of items below) : E : Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, motors, misc. electrical panels and equipment etc., including transportation from store/yard to site at the place of installation, lifting the panels and equipment by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures,anchoring, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. The channel supports on cable trench required to position the panels etc. shall be measured and paid separately.
Panel etc. install: Weight more than 500Kg to 1000 kg PANEL ETC. INSTALL: (Common specification for this & same category of items below) : E : Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, motors, misc. electrical panels and equipment etc., including transportation from store/yard to site at the place of installation, lifting the panels and equipment by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures,anchoring, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. The channel supports on cable trench required to position the panels etc. shall be measured and paid separately.
Panel etc. install: Weight more than 1000 kg to 3000 Kg PANEL ETC. INSTALL: (Common specification for this & same category of items below) : E : Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, motors, misc. electrical panels and equipment etc., including transportation from store/yard to site at the place of installation, lifting the panels and equipment by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures,anchoring, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. The channel supports on cable trench required to position the panels etc. shall be measured and paid separately.
Panel etc. install: Weight more than 3000 kg to 8000 Kg PANEL ETC. INSTALL: (Common specification for this & same category of items below) : E : Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, motors, misc. electrical panels and equipment etc., including transportation from store/yard to site at the place of installation, lifting the panels and equipment by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures,anchoring, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. The channel supports on cable trench required to position the panels etc. shall be measured and paid separately.
Making of HT heat shrinkable cable joints and end terminations for indoor & outdoor as per requirement- including cutting, stripping of insulation etc. upto 400 sqmm excluding supply of jointing kit and accessories including all labour and materials etc complete as required. 3 Core cables 11 kV, upto 400 sqmm.
Making of LT cable joint for cables with OD upto 40 mm. HEAT SHRINK JOINTS : Making of heat shrinkable type straight through joints for 1100 volt grade PVC/XLPE cables as per specifications, including cutting, stripping of cable insulation complete with supply of consumable, accessories etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge excluding supply of heat shrinkable jointing kit ."
Making of LT cable joint for cables with OD above 40 mm. HEAT SHRINK JOINTS : Making of heat shrinkable type straight through joints for 1100 volt grade PVC/XLPE cables as per specifications, including cutting, stripping of cable insulation complete with supply of consumable, accessories etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge excluding supply of heat shrinkable jointing kit."
CEA Approval
Arranging CEIG / CEA / Statutory approvals for the entire electrical installation of the plant. Job includes arranging visit of officials, inspection. Preparation of drawings if any, liquidation of punch points by Inspectors, arranging Certificate & approvals all complete. The Base drawings as available with Owner shall be provided .(The prescribed fees for approvals & inspection if paid by Contractor shall be reimbursed by Owner against submission of Documentary Evidence).
Civil Job
Transportation of surplus earth/debris Transportation of surplus earth/debris (excavated earth from item 7.0 above) Carting the surplus excavated earth/rocks and debris from construction area beyond the initial lead of 500 meters to the approved dumping area within the plant boundary including re-excavating deposited soil excavated earlier, transportation, loading, unloading, laying at all depths/heights, stacking, levelling and dressing both the area (viz. from where the earth is carted and where it is deposited) to required levels and slopes complete with all lifts.
LEAN CONCRETE (PCC 1:3:6) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) aggregate as leveling course in foundations, under slabs on grade etc., including tamping, curing, shuttering etc. complete for all depths and heights. Materials to be supplied as per approved vendor lists attached with special conditions of contract
M-25 grade of concrete "FOUNDATION CONCRETEProviding and laying in position Reinforced Cement Concrete in open foundations, trenches, precast cover slabs of specified grade( design mix ) with 20mm and down size graded stone aggregates including screening and cleaning of coarse aggregates, fineaggregate (sand) conforming to proper grading, zone, both of approved quality and Ordinary POrtlamnd Cement , as necessary, cost of curing with water, excluding cost of centering and shuttering and reinforcement including providing pockets/ shear keys during concreting, vibrating, tamping, curing, sampling, testing and rendering if required, to give a smooth and even surface etc. including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control,sampling, testing etc. including cost of all material & labor in substructure, footings and other similar items not specifically mentioned herein, for all depths, complete as per drawings, specification and as directed by Engineer-in-charge/ owner. For details refer specification for Plain and Reinforced concrete. Materials to be supplied as per approved vendor lists attached with special conditions of contract.M-25 grade of concrete
M-30 grade of concrete FOUNDATION CONCRETEProviding and laying in position Reinforced Cement Concrete in open foundations, trenches, precast cover slabs of specified grade( design mix ) with 20mm and down size graded stone aggregates including screening and cleaning of coarse aggregates, fineaggregate (sand) conforming to proper grading, zone, both of approved quality and Ordinary POrtlamnd Cement , as necessary, cost of curing with water, excluding cost of centering and shuttering and reinforcement including providing pockets/ shear keys during concreting, vibrating, tamping, curing, sampling, testing and rendering if required, to give a smooth and even surface etc. including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control,sampling, testing etc. including cost of all material & labor in substructure, footings and other similar items not specifically mentioned herein, for all depths, complete as per drawings, specification and as directed by Engineer-in-charge/ owner. For details refer specification for Plain and Reinforced concrete Materials to be supplied as per approved vendor lists attached with special conditions of contract.M-30 grade of concrete
FORMWORK Providing and fixing plywood centring and shuttering straight / inclined, in foundations for footings, rafts, retaining walls, trenches, pedestals, pipe sleepers, culverts, drains, pipe way bridges, tunnels, liquid storage structures etc. including keeping the same in position during concreting and removal of the same after specified period, keeping necessary provision for inserts, projecting dowels etc., tools, equipments and labour necessary for the work all compete, and as specified and directed.
DEFORMED/TMT STEEL BARS FOR CONCRETE Supply and fixing in position TMT reinforcement bars Fe500D conforming to IS-1786 (FY=500 MPa) for RCC work including the cost of steel and cost of binding wire, carting the same to site of work, straightening, cleaning, cutting, binding with 18 SWG black soft annealed binding wire, and placing with proper cover blocks, supports, chairs, spacers, complete for all heights and depths complete as per drawing & specification. Materials to be supplied as per approved vendor lists attached with special conditions of contract. For payment reinforcement including authorized weight for spacer bars, laps, chairs etc shall be measured separately for diameter wise length actually used. Wastages & unauthorized laps shall not be considered for payment. Inspections and Tests as per relevant technical specifications and codes shall be deemed to be included in the scope
SUPPLY AND INSTALLATION OF ANCHOR BOLTS "Fabricating, supplying and installing thread Anchor Bolts of specified diameter conforming to IS 2062 Grade BR as per drawings, including the cost of M.S. rounds and plates, nuts, washers , anchor plates, fine plates, stiffness, pipes sleeves etc, material as per relevant IS codes, fixing in position with necessary, tools, templates, labour etc for all heights and depths, all complete. Materials to be supplied as per approved vendor lists attached with special conditions of contract
NON-SHRINK GROUT FOR STRUCTURAL STEEL Supply and laying non-shrinking grout with a minimum crushing strength of 40 N/mm2 for grouting under base plates, base frames or other anchoring elements for structures and/or machines, including cleaning of surfaces, form-works,chamfering of edges, smoothing of exposed surfaces, providing all tools and labour necessary to complete the work as per drawings / specifications and as directed. The non shrink grout shall be laid as per approved vendor‘s specification (SIKA/FOSROC make)
Pre coated sheet Providing corrugated GS sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks,bolts and nuts,8mm diameter with bitumen and GI limpet washers or with GI limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete(upto any pitch in horizontal/vertical or curved surfaces), excluding the cost of perlins, rafters and trusses and icluding cutting into sizes and shapes wherever required 0.63 mm thick with zinc coating not less than 275 gm/m2
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes including all labour and material
BRICK WORK Brick work with common burnt clay bricks of class designation 7.5 in mud mortar
Earth work in excavation for all kind of Soil including all labour, materials, dressing of sides, pumping & bailing out water accumulated due to rain and / or subsoil waters and including disposal or stacking, leveling and neatly dressing as decided by Engineer-in-Charge including providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., if any, complete, including shoring/ strutting /sheet pile, all materials and labour complete and as directed by Engineer-in-Charge for following depth.Excavated soil shall be disposed at least 50 m away from the Plant Boundary / kept for backfilling within a radius of 500M and the charges for the same is included in this item.Earthwork in excavation from grade level upto 1.5 m depth"
Earth work in excavation for all kind of Soil including all labour, materials, dressing of sides, pumping & bailing out water accumulated due to rain and / or subsoil waters and including disposal or stacking, leveling and neatly dressing as decided by Engineer-in-Charge including providing temporary supports to existing service lines like water pipes, sewerage, electric cables, etc., if any, complete, including shoring/ strutting /sheet pile, all materials and labour complete and as directed by Engineer-in-Charge for following depth.Excavated soil shall be disposed at least 50 m away from the Plant Boundary / kept for backfilling within a radius of 500M and the charges for the same is included in this item.Earthwork in excavation from 1.5 m depth from grade level
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
RCC/PCC structure Breaking using Demolition Breaker (any thickness)
Brickwork structure Manual Breaking (any thickness)
Chequered plate of M.S 6 mm thick - Supply, fabrication and installation for covering floor cut- outs/cable trenches etc., including all labour and materials as per EIC
Supply of sealing compound (Bituminous tar/eqv) heating & pouring of compound in the metallic pipes for providing effective cable sealing.
Supply, fabrication and installation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
Cross linked fencing works Preparation of fencing around the periphery of HT panels and CSS including supply of all materials,labour and as per direction of Engineer-in-Charge
Singhi InfraPower Projects Pvt. Ltd.
M/s. Everlite Engineering Industries
Power Tools and Engineering
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .