Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Jun 2024, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
REPAIR AND REPLACEMENT OF UNSV STREET LIGHT /SECURITY LIGHTS, HIGH MAST LIGHTS, GATE LIGHTS AT DEMO SQN , DEMO BTY,ARO,SUPPLY DEPOT , EME WKSP, SARNA ENCLAVE AND GOSWAMI ENCLAVE UNDER GE (AWC) MHOW .
2024_MES_652294_1
8734 GE(AWC) /MHOW / OF 2024-25
Open Tender
Civil Works
Item Rate
335 days
GE AWC MHOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹50,000
Yes
4 Sept 2024
4 May 2024
3 Jun 2024
4 May 2024
1 Jun 2024
18 May 2024
Amount
Supplying, laying, fixing, jointing and testing LT under ground XLPE insulated, galvanised teel strip or wire armoured heavy duty electric cable with alumimium conductor,with multi stranded 1100 volts grade, cross sectional area 16 Sqmm x 4 Core, ISI-7098 marked, with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. and including taking down complete all as specified and directed. Note - Excavation, earth work, sand cushioning, protection bricks/tiles/ block, clamps, nuts , bolts, washers and pipe shall be measured and paid separately.
All as per item No. 1 above but 10 sqmm x 4 Core
All as per item No. 1 above but 10 sqmm x 2 Core
Supplying, laying, fixing, jointing and testing LT services cable heavy duty electric cable with copper conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core, ISI marked, with electric connection lugs, fixed naked with walls / on poles/ on high mast / in GI pipes etc. and including taking down complete all as specified and directed.
Supplying, laying, fixing, jointing and testing LT services cable heavy duty electric cable with copper conductor, 1100 volts grade, cross sectional area 6 sqmm 2 core, ISI marked, with electric connection lugs, fixed naked with walls / on poles/ on high mast / in GI pipes etc. and including taking down complete all as specified and directed.
Supply and laying in replacement GI pipe 'light grade' 40 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends complete all as specified and directed.
All as per Sl. Item No. 6 above but GI pipe 'light grade' 50 mm
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes poles etc. and getting out all excavated material in any type of soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L of Locally available river sand filling in trenches below and above / around UG cable for cable protection, in duct under & above the cables including punning around cable complete all as specified and directed.Note - Punned thickness shall only be measured and paid.
Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed.
Taking down old unserviceable street light pole complete including dismantling of street light and shifting the same street light for fixing in another pole not more than one km distance including bracket and nut bolt etc. complete all as specified and directed. Note - Excavation, concrete and copping shall be measured and paid separately.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping including existing pole including weathering slightly rounded / chamfered angle with and including necessary use and waste of foam work for fair finished surfaces complete all as specified and directed.
M&L for painting of security light steel tubular pole upto 09 mtrs length including clamp, bracket and junction box with two coats of aluminium paint including scraping after preparation of old painted surface and providing 03 no. alternate strip of 30 cm wide with black and Yellow super quality enamel paint above embeded level and writing pole no. with 02 inch wide letter complete all as specified and directed by Engr-in-Charge.
M&L for LED Light Tiranga Rope Light Indian Tricolour Strip light -Orange +White +Green colour in single strip of security light steel tubular pole upto 09 mtrs length including clamp, bracket and junction box with two coats of aluminium paint Including scraping after preparation of old painted surface and providing 03 no. alternate strip of 50 cm wide with Orange,Green and white Conspicuity tape highly reflective tape above embeded level and writing pole no. with black round circle 02 inch wide letter complete all as specified and directed.
M&L for painting of security light steel tubular pole upto 09 mtrs length including clamp, bracket and junction box with two coats of aluminium paint Including scraping after preparation of old painted surface and providing 03 no. alternate strip of 50 cm wide with Orange,Green and white Conspicuity tape highly reflective tape above embeded level and writing pole no. with black round circle 02 inch wide letter complete all as specified and directed.
M&L for painting of Street light Steel tubular poles swan neck with two coats of aluminium paint including scraping after preparation of old painted surface and providing 03 no. alternate strip of 30 cm wide with black and white super quality enamel paint above embeded level and writing pole no. with 02 inch wide letter complete all as specified and directed.
Supply and fixing in replacement Energy efficient inverter street light 90 watt with RTC having the following Technical Specifications : - Housing Material : Aluminium PDC, Top maintainable Front Cover : Clear toughened glass Lens : LM80 certified LED LED Lumen Maintenance : 50,000 hours @ L 70 Control Gear : Isolated, Electronic, CC driver RTC enabled Internal Wiring : Insulated Copper wire Hardware : SS & MS Zinc plated and passivated Ingress Protection : IP 66 Impact Resistance : IK05 Operating Voltage : 140 V~270V Operating Temperature : - 10oC ~50oC Emergency light output : Initial Lumen at Battery mode will reduce to 15-20% Emergency time : 1.5-2 hours Max. (Battery Back-up withLi-ion Battery) complete all as specified and directed. Cat Part No.: - HLSLD - ML04-45-CWL-INV-RTC-R Note :-The Street Light should have a minimum 03 years warranty submitted by the tenderer from manufacture.
Supply, Installation, Testing and Commissioning of LED Street light Fitting with a nominal system 5300 lumen output of lumens, minimum system efficacy of 115 lm/W and total power consumption not exceeding 45 W (including driver). The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a color temperature of 5700 - 6500K and CRI>80. The luminaire shall meet IP66/IK07 or IK08 rating with THD<10% and PF > 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The driver should have phase to phase protection for 8 hours. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate "R" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole complete all as specified and directed.
All as per Sl. Item No. 22 above but with nominal system output of 8400 lumens, minimum system efficacy of 110 lm/W and total power consumption not exceeding 70 / 72 W (including driver).
All as per Sl. Item No. 22 above but with nominal system output of 11000 lumens, minimum system efficacy of 120 lm/W and total power consumption not exceeding 90 W (including driver).
All as per Sl. Item No. 22 above but with nominal system output of 15000 lumens, minimum system efficacy of 120 lm/W and total power consumption not exceeding 120 W (including driver).
Supply, fixing, testing and commissioning in replacement energy saving long life LED 45W (gate light fitting) post top made in cast aluminium with decorative opal polycarbonate diffuser and IP 65 protection and alluminium housing with effcient designed heat shrink with heat resistent toughned glass with frame fixed with SS screws suitable for fixing including nut bolt as per site requirement complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement energy saving long life LED 40W (gate light fitting) post top made in cast aluminium with decorative opal polycarbonate diffuser and IP 65 protection and alluminium housing with effcient designed heat shrink with heat resistent toughned glass with frame fixed with SS screws suitable for fixing including nut bolt as per site requirement complete all as specified and directed.
Disconnecting and lowering carefully light fittings from high mast, 12-20 mtr high for maintenace / repairs of light fittings and refixing the light fittings after repairs complete all as specified and directed. Note:- Spare parts shall be measured and paid separately.
Supply, Installation, Testing and Commissioning in replacement of LED Floodlight Fitting with a nominal system 16200 lumen output of lumens, minimum system efficacy of 110 lm/W and the total power consumption should not exceed 150 W (including driver). The luminaire shall have a rated system lifetime of 25,000 burning hours at L70B50. The luminaire should have a color temperature of 5700 - 6500K and CRI>80. The luminaire shall meet IP65/IK07 rating with THD<10% and PF > 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 kV. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with photo biological report. Luminaire and the driver shall be BIS certified separately and shall posses separate "R" numbers. Fitting should include nut bolt and SS screws for suitably fixing on the exiting steel tubular pole complete all as specified and directed.
All as per Sl. Item No. 29 above but with nominal system output of 21600 lumens, minimum system efficacy of 110 lm/W and total power consumption not exceeding 200 W (including driver).
Disconnecting and taking down street / security light fitting of any size / capacity / make from the pole / bldg for repair / replacment of unservisable spare parts etc., testing, cleaning the fitting internally and externally and replacement of unserviceable wiring not more than 0.3 Mtrs with 1.5 sqmm PVC insulate copper wire, checking and repairing of loose connections, replacement of wire connectors, nuts, bolts, screws and fixing the light fitting in original position on wall / pole / santry post / top of building including necessary electrical connection complete all as specified and directed by Engr-in-Charge. Note:- Driver and SPD shall be measured and paid separately.
Supply, fixing, testing and commissioning in replacement SPD for LED Street light / flood light fitting with suitable surge capacity complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement Driver for LED Street light / flood light fitting with suitable surge capacity complete all as specified and directed.
S&F in repairs 8 kW, single phase nature switch for automatic switching on / off street light based on lux level of nature light, consisting of sensor, overload protection fuse gear, power contactor and MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole / wall mountable enclosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 54, with universal lock and key arrangement complete all as specified and as directed.
All as per item No. 34 above but 12 kW, Three phase.
S&F in replacement sensor of nature switch having illuminance level for switching ON at 30 lux and for switching OFF at 10 lux along with part night operation facilty of 4-12 hrs arrangement complete all as specified and directed.
S&F in replacement of security light bracket with 40 mm dia GI Pipe light grade 1.2 mtr long bend to an angle of 120 degrees with two nos. MS flat iron clamp 50 x 6 mm, nuts, bolts and washers, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in replacement of PVC junction box IP - 66 Thermoplastic PC- GFS Polycarbonate weatherproof Junction Box with Degree of protection against mechanical load IK09 (10 Joule) with plain walls for cable entries to be drilled individually. The plain side walls on the four sides can be drilled and customized for cable entries from any direction. The Junction box Internally embedded polyurethane material Gaskit. Lid fasteners shall not have screws but shall be with quarter turn locking knobs . The junction box shall fulfill the following standards Weatherproof : UV resistant due to solar radiation, Rainwater proof, temperature resistant. Salt water proof & shall be suitable for off-shore applications. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 degree of protection. colour: black, RAL 9011 Degree of protection against mechanical load IK09 (10 Joule) Technical details Cat.no.- KF 1600C with MCB 6A SP ,4nos 16sq.mm terminal Block Dimension in mm- 155 x 210 x 92 mm
Trimming / lopping of tree branches touching LT/HT OH lines not exceeding 30 cm girth, shrub, vegetation, bushwwod and saplings at least upto 2 mtr from outer edge of ACSR including removing of braches of trees etc. to a distance exceeding 100 mtr and not exceeding 150 mtr complete all as specified and directed. Note :- (i) Linear length centre to centre of the poles shall only be measured. (ii) Shutdown wherever required shall be taken from Engr-in-Charge.
Supply, fixing in replacement energy saving enviornmental friendly long life exclusive innovative die cast aluminium IP- 66 flood light 120 watt suitable for highlighting architectural facade and general purpose lighting complete all as specified and as directed
M&L in replacement steel tubular swagd poles complete with cast iron base plate, finial tapper plug, bolts, nuts & screws as specified type 410 SP-31(9 mtr long) complete all as specified including painting of pole with one coat of black bituminous paint (up to planting depth) and above plinth block / concrete coller with two coats of aluminium paint over a coat of red oxide primer including making five alternate strips 30 cm wide with black and yellow paint in two coats, including three core wire minimum 1.5 sqmm from junction box to street light complete all as specified and directed.
Supply and fix inreplacement of Digital time switchs programmable every I min, with backup of 6year , 28 memory locations, current capacity 16 A, weekly program, with 1 changeover (1 CO) total 28 programs complete all as specified and directed.
Archana Construction
Ms Kailash Chandra Babulal
J K Enterprises
Raj Contruction
Vinayak Trading House
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .