Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 819 KASBA PETH PUNE PUNE PUNE MAHARASHTRA 411011 | PUNE | MAHARASHTRA | 411011 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹6.0 L
Closing Date
9 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Pune
GE North Pune Gen Cariappa Marg Pune-411001
Provision of area security lighting for security wall along MM road under GE (North) Pune
2023_MES_620204_2
E310
Limited
Job Works
Works
45 days
GE North Pune
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
11 Oct 2023
3 Oct 2023
11 Oct 2023
3 Oct 2023
9 Oct 2023
4 Oct 2023
Supply of LINEAR 1000/1200mm RGBW surface mounted wall washer luminaire suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with mid/high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric/elliptical distribution. Luminaire luminous flux range 1450-1500 Lm. Luminaire having DMX 512 control protocol capable of producing 16.7 million colour options. The luminaire should have options for various beam angles: 8⁰/15⁰/25⁰/35⁰/10⁰x60⁰/15⁰x45⁰. Power consumption should be between 36W to 38W at steady state full intensity. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of Extrusion Aluminium. Impact resistance level should be suitable to site condition of minimum IK08. Adequate surface with proper thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. LEDs of CREE / LUMILED / OSRAM / SEOUL / SAMSUNG/Bridgelux reputed make shall be used for the light fittings. Luminaire Shall be BIS approved. Cat. Ref. Bajaj BA WW IN1 36W , RGBW (With Driver & Decoder)
Supply Instalation testing & commissioning of Color changing RGBW surface mounted Narrow/Medium/Wide beam luminaire suitable for outdoor applications of Facade Lighting, depending on design by the contractor and site requirement. 2. Luminaires should be enabled with high power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement. 3. The luminaire should have options for various beam angles i.e. from 8° to 80°, actual will depend on the design by the contractor and site requirement. 4. Power consumption should be between 75W to 80W at steady state full intensity, Luminaire luminous flux range of 2600- 2850 Lm. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt and each light fixture should be invidually addressable & should be able to operate with any standard DMX512 equipment. 5. Color rendering index CRI ≥ 80 for white LEDS's and power factor of complete luminaire ≥ 0.90, at full intensity. 6. Luminaire should be provided with suitable integral/separate non-integral power supply unit. 7. Lumen maintenance of at least L70@50,000 burning hours at 25°C. 8. The luminaire should have powder coating pressure die cast aluminium housing with minimum 3-4mm thick safety glass. 9.Ingress Protection ≥ IP 66. Impact resistance level ≥ IK 07. Adequate heat sink with proper thermal management shall be provided. 10. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%. THD should be less than 15%. 11. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. 12. Connectors if used should be IP67 male/female connectors for loop through wiring. 13. The LED Luminaires and external drivers drivers if used should be BIS certified. 14. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. 15. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED /NICHIA. BA RP IN1 75W, 10 DEGREE , RGBW (With Driver & Decoder)
1. Supply Instalation testing & commissioning of Color changing RGBW surface mounted Narrow/Medium/Wide beam luminaire suitable for outdoor applications of Facade Lighting, depending on design by the contractor and site requirement. 2. Luminaires should be enabled with high power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement. 3. The luminaire should have options for various beam angles i.e. from 8° to 80°, actual will depend on the design by the contractor and site requirement. 4. Power consumption should be between 75W to 80W at steady state full intensity, Luminaire luminous flux range of 2600- 2850 Lm. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt and each light fixture should be invidually addressable & should be able to operate with any standard DMX512 equipment. 5. Color rendering index CRI ≥ 80 for white LEDS's and power factor of complete luminaire ≥ 0.90, at full intensity. 6. Luminaire should be provided with suitable integral/separate non-integral power supply unit. 7. Lumen maintenance of at least L70@50,000 burning hours at 25°C. 8. The luminaire should have powder coating pressure die cast aluminium housing with minimum 3-4mm thick safety glass. 9.Ingress Protection ≥ IP 66. Impact resistance level ≥ IK 07. Adequate heat sink with proper thermal management shall be provided. 10. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%. THD should be less than 15%. 11. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. 12. Connectors if used should be IP67 male/female connectors for loop through wiring. 13. The LED Luminaires and external drivers drivers if used should be BIS certified. 14. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. 15. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED /NICHIA. BA RP IN1 75W, 10 DEGREE , RGBW (With Driver & Decoder)
Supply of LINEAR 1000/1200mm RGBW surface mounted wall washer luminaire suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with mid/high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric/elliptical distribution. Luminaire luminous flux range 1050-1500 Lm. Luminaire having DMX 512 control protocol capable of producing 16.7 million colour options. The luminaire should have options for various beam angles: 8⁰/15⁰/25⁰/35⁰/10⁰x60⁰/15⁰x45⁰. Power consumption should be between 18W at steady state full intensity. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of Extrusion Aluminium. Impact resistance level should be suitable to site condition of minimum IK08. Adequate surface with proper thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. LEDs of CREE / LUMILED / OSRAM / SEOUL / SAMSUNG/Bridgelux reputed make shall be used for the light fittings. Luminaire Shall be BIS approved. Cat. BA WW IN1 18W, WARM WHITE (RGBW IF WANT)
BA RP IN1 28W WW/WH (In 36W)Supply of surface mounted warm White Floodlight Projector luminaire suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant dedicated optics with symmetric distribution. With clear toughned glass cover, clear/powder coated. Luminaire luminous flux range 3300-3400 Lm.onsumption should be between 28W to 36 watt at steady state full intensity. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of pressure Die cast high strength Aluminium with 3-4mm thick safety glass. Impact resistance level should be suitable to site condition minimum IK08. Adequate heat sink with efficient thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. LEDs of CREE / LUMILED / OSRAM / SEOUL / SAMSUNG/Bridgelux reputed make shall be used for the light fittings. Luminaire Shall be BIS approved. Cat. Ref. Bajaj BA RP IN1 28W, WARM WHITE
BA RP IN10W WW/WH (In 10W)Supply of surface mounted warm White Floodlight Projector luminaire suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant dedicated optics with symmetric distribution. With clear toughned glass cover, clear/powder coated. Luminaire luminous flux range 1000-1100 Lm. Power consumption should be between 10W to 12W at steady state full intensity. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of pressure Die cast high strength Aluminium with 3-4mm thick safety glass. Impact resistance level should be suitable to site condition minimum IK08. Adequate heat sink with efficient thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. LEDs of CREE / LUMILED / OSRAM / SEOUL / SAMSUNG/Bridgelux reputed make shall be used for the light fittings. Luminaire Shall be BIS approve BA RP IN1 10W, WARM WHITE
Supply of DMX Controller System with Standalone interfaces. Controller should deliver 2*512DMX channels, the controller should have future upgradation provision up to 4 DMX universe Port. the controller should have new Nicolaudie Stand Alone engine (NSA) offering some great possibilities (multi-zone, extended triggers, 16-bit channels management...). the controller should offer multiple possibilities to trigger your lighting scenes: time/date, input ports, TCP/UDP commands. Should have Intuitive backlit keyboard with 10 presets. PC DMX INtriggers:Yes, Standalone DMX IN triggers: External triggers: 10 buttons for direct access,2 buttons to change scene,+ 1 button to change zone. 16 dry contact trigger ports via 20-Pin IDC Socket. Internal calendar: Yes, Backup of the internal clock: Yes, 3weeks without power, Memory card: Yes microSD card, 32GB max, Input power voltage: 5-5.5V DC 0.6A with power adaopter working on AC power supply,. via USB(USB power supply included), Trigger lighting scenes using calendar triggers and conditional rules with New Stand Alone engine, using contact ports, RS232 or over Ethernet. Stand Alone mode with 99 scenes across 5 zones. Buttons: iPhone/iPad/Android remote and programming apps. Temperature: 0 to +50 C°, DMX Compatibility: 8 and 16 bit DMX fixtures, System Compatibility: Windows XP, Vista, 7, 8, 8.1, 10, MAC OS X. Make: Bajaj DMX Controller (UE11) SLESA U11
DMX SPLITTER (INK) – Pioneer 6 Output
Supply, installation, testing and commissioning of DMX Splitter cum Booster ,Input Power- 100 to 240 VAC, auto-ranging, 50/60 Hz.,Housing rugged alluminium, Operation Temperature -17ºC ~ +55ºC (0ºF ~ 131ºF) , 5/6 output ports with 3/5-pin terminal sockets , each port should be optically isolated , Protection Rating IP20 including connection complete as requiredCharges for DMX Programming and Commissioning
Fine-Tech. Electricals
K SONS
stage.html
html • 0.02 MB
finance_695753.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .