| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC AOC Acepted | |
| 2 | L2₹19.9 L+₹1.5 L (8.00%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹20.1 L+₹1.6 L (8.58%)Rejected-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹20.4 L+₹1.9 L (10.4%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L4 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 May 2020, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon . Near Atul Kataria Chowk Gurgaon
REPAIR, MAINTENANCE, SERVICING, OVERHAULING AND CONNECTED WORKS FOR SUMMER APPLIANCES INCLUDING REPLACEMENT OF POINT WIRING AND SUB MAIN WIRING, CEILING FAN, EXHAUST FAN, AIR CIRCULATOR, ELECTRIC METER AND CONNECTED WORKS AT 54 ASP UNDER GE (P) AF G
2020_MES_339377_1
GE (P) AF/Gur-13/2020-21
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (P) AF Gurgaon
All as specified in NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹60,000
Yes
16 Jun 2020
17 Apr 2020
20 May 2020
18 Apr 2020
18 May 2020
4 May 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site/Sch of credit and making good disturbed surface of walls, floors, etc., complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and including PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate complete all as specified and as directed by Engr-in-charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):-
One light point controlled by one way one switch SP 5 Amps , 240 V.
One ceiling fan / Exhaust point controlled by one way one switch SP 5 Amps, 240 V.
One light point controlled by two 2 way switch SP 5 Amps ,240 V.
One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
One switch socket outlet 3 Pin, 5 Amps, SP on same board.
One bell point controlled by one way one switch SP 5 Amps , 240 V.
All as per the item No 2 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet 6A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet 6A/16A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch 2 way 6 Amps 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch 1 way 16 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose 3 phase/PVC/ polycarbonate isolated body, complete all as specified and as directed by Engineer-in-Charge.
S&F step type elctronic fan regulator Modular type, single phase 220 V , one module type, OR in repair complete all as specified and as directed by Engineer-in-Charge.
S&F modular bell push switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
M&L for Point wiring complete with FRLS PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sqmm (Norminal area) multistranded , copper conductor cable drawn through in non metallic rigid PVC conduit medium grade , minimum 20 mm dia conceled in wall , ISI Marked, and connect accessories, mounting on suface of walls / ceilings /roofs etc with shunken box anodised concealed in suface of wall , 3 mm thick laminated plastic sheet cover for mounting of switches, sockets outlets, regulators etc, fixed by suitable size of 04 Nos cadmium screwes including provision of FRLS PVC insulated unsheathed 1.5 Sqmm muiltistranded green colour copper conductor cable as earth connectivity and connecting to common earth dolly complete all as specified and as directed by Engineer-in-Charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):-
One light point controlled by one way one switch SP 5 Amps , 240 V.
One ceiling fan/Exhaust point controlled by one way one switch SP 5 Amps, 240 V.
One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
One switch socket outlet 3 Pin, 5 Amps, SP on same board.
One bell point controlled by one way one switch SP 5 Amps , 240 V.
One light point controlled by two 2 way switch SP 5 Amps , 240 V.
All as per the item No 12 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge.
S&F switch piano flush type single pole one way , 5 Amps , 240V grade ISI marked , complete all as specified and as directed by Engineer-in-Charge.
S&F switch piano flush type single pole one way , 15 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F socket outlet 2 in 1 ,3 pin 5 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F socket outlet 2 in 1 ,3 pin 5 and15 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F switch bell push piano flush type single pole one way , 5 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F switch piano flush type single pole two way , 5 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F step type elctronic fan regulator flush type, single phase 220 V , one module type, OR in repair complete all as specified and as directed by Engineer-in-Charge. Make : Anchor or equivalent in Kinjal.
Taking out old U/S submain wiring of any size and removing materials to store or as sch of credit including making good of existing surfaces complete all as specified and as directed.
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of 6 Sqmm and one run of 4 Sqmm FR copper conductor as earth wire and connected to earth dolly all as specified and as directed by Engr-in-Charge. ( The item includes cutting Chasis and making good the disturbed surfaces).
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of 10 Sqmm and one run of 6 Sqmm FR copper conductor as earth wire and connected to earth dolly all as specified and as directed by Engr-in-Charge. ( The item includes cutting Chasis and making good the disturbed surfaces).
S&F in repairs sheet metal enclosure for MCB's (D.B) 4 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDPSHODRW04 Make Havells or equivalent out of makes specified in list of makes.
S&F in replacement of Ding Dong Bell, single phase, 230 volt AC, 50 HZ, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement , Batten holder bakelite AC, 220 V, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs sheet metal enclosure for MCB's (D.B) 6 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDPSHODRW06 Make Havells or equivalent out of makes specified in list of makes.
S&F in repairs sheet metal enclosure for MCB's (D.B) 8 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDPSHODRW08 Make Havells or equivalent out of makes specified in list of makes.
S&F in repairs sheet metal enclosure triple pole and neutral 415 Volts 4 way Double door, complete all as specified and as directed by Engineer-in-Charge. Cat N0- DHDLVDRWG OFO04 Make Havells or equivalent out of makes specified in list of makes.
S&F in repairs sheet metal enclosure triple pole and neutral vertical Loadline 415 Volts 8 way (TPN) Double door Cat N0- DHDLVDRWGOFO08 Make Havells or equivalent out of makes specified in list of makes.
S&F MCB 240 volts SPN 06- 32 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMCCSNF006-032 Make Havells or equivalent out of makes specified in list of make.
S&F MCB 240 volts SPN 06- 40 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMCCSNF006-032 Make Havells or equivalent out of makes specified in list of make.
S&F MCB 240 volts 2 pole (DP) - 40 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMCCSNF006-032 Make Havells or equivalent out of makes specified in list of make.
S&F MCB 240 volts SP 6- 32 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMCCSPF006-032 Make Havells or equivalent
S&F MCB 415volts TPN 63 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed, Cat No- DHMCCTNF063 of Make Havells or equivalent out of makes specified in list of make.
Supply & Fix in replacement of MCCB 4 pole 415 V fixed type 63 Amps with breaking capacity 16 KA complete all as specified and directed. Make Havells or equivalent out of makes specified in list of make.
S&F MCCB 100 Amps 4 pole 415 Volts 16 KA breaking capacity complete all as specified and directed, Cat No- IHLGNF0100 of Make Havells or equivalent out of makes specified in list of make.
S&F Blanking plates suitable for MCB DB's of Make Havells or equivalent out of makes specified in list of make.
Supply and fixing industrial panel mounting Socket Splash proof 16 amp protection degree 44 , code CS62210 PIN 3P+N+415 volt complete all as specified and as directed. Havells or equivalent out of makes specified in list of make.
Supply and fixing industrial panel mounting Plug Splash proof 16 amp protection degree 44 , code CS60031 5 PIN 3P+N+415 volt complete all as specified and as directed. Havells or equivalent out of makes specified in list of make.
S&F in replacement ceiling light fittings with new energy saving LED ceiling light fitting of capacity 36 Watt including 3 core PVC insulated copper conductor upto ceiling rose and testing complete all as directed by Engr-in-charge. Make : C&S cat part No :- LTCRSLM36WATT2X2 or equivalent in Philips/Wipro.
Taking down and serviceing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt, rubber real, bush gun metal, ball bearing, capacitor split pin and re-assembling the fan including testing after assembling, hanging/fixing on fan hook and connecting to electric system complete all as specified and as directed by Engr-in-Charge. NOTE:- Supply of bearing, capacitor, blades & painting shall be measured and paid seperately in the concerned item of schedule.
All as per srl item No 42 hereinbefore but for wall mounting fan plastic type of size 400/450mm sweep.
All as per srl item No 42 hereinbefore but for exhaust fan of any size complete.
Taking down carefully AC single phase 220/230volt ceiling fan 1200/1400mm sweep single phase for rewinding and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps including servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin, rubber packing and rubber seal etc including testing after assembling, hanging/fixing on hook and connecting to electric system complete all as specified and as directed by Engr-in-Charge. . Note : 1. Rates of winding and replacement of any unserviceable parts mentioned above required to make the fan in serviceable condition except Note 2 below are included in the quoted rate. 2. Rates of bearing, capacitor, blades & painting shall be measured and paid seperately in the concered item of schedule.
All as per srl item No 45 hreinbefore but for wall mounting fan plastic type of size 400mm sweep complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 45 hereinbefore but for wall mounting fan plastic type of size 450mm sweep complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 45 hereinbefore but for exhaust fan of size 250mm sweep plastic type square/round shape complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 45 hereinbefore but for exhaust fan 300mm sweep complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 45 hereinbefore but for exhaust fan 450mm sweep complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 45 hereinbefore but for exhaust fan 600mm sweep complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 45 hereinbefore but for air circulator wall mounting fan metallic type 450mm sweep complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 45 hereinbefore but for air circulator wall mounting fan metallic type 600mm sweep complete all as specified and as directed by Engineer-in-Charge.
Supply only capacitor 2.5 mfd + 5%, 220/230 volts AC, 50 c/s, complete all as specified and as directed by Engineer-in-Charge. Make: Usha/Epcos/Tibcon.
Supply only capacitor 3.15 mfd + 5%, 220/230 volts AC, 50 c/s, complete all as specified and as directed by Engineer-in-Charge. Make: Usha/Epcos/Tibcon.
Supply only capacitor 4 mfd + 5%, 400/440 volts AC, 50 c/s, complete all as specified and as directed by Engineer-in-Charge. Make: Usha/Epcos/Tibcon.
Supply only Electric cable PVC insulated with copper conductor (flexible cable) size 23/0.0076 twin core for connecting fan to electric system, complete all as specified and as directed by Engineer-in-Charge.
M&L for Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of 1200/1400mm sweep of any make complete all as specified and as directed by Engineer-in-Charge.
M&L for Spray painting to AC ceiling fan 1200/1400mm sweep any make complete to motor assy, down rods, blades with ISI marked white/brown synthetic enamel paint as approved by Engr-in-Charge after preparation of surface including filling cavities with filler, writing of MES No complete complete all as specified and as directed by Engr-in-charge
Taking down metallic type wall mounting fan of size 400/450mm sweep in situ for spray painting with ISI marked OG/brown/black synthetic enamel paint as directed by Engr-in-charge after preparation of surface and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge.
All as per item No 60 but for exhaust fan 300mm, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 60 but for exhaust fan exceeding 300mm and upto 450mm, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 60 but for exhaust fan exceeding 450mm and upto 600mm, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 60 but for air circulator wall mounting fan of size 450 to 600mm, complete all as specified and as directed by Engineer-in-Charge.
Supply only Canopies for AC ceiling fan of size 1200/1400mm sweep for any make of fan, complete all as specified and as directed by Engineer-in-Charge.
Supply only down rods for ceiling fan 1200/1400mm sweep of size 2.5' long duly painted with white synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Supply only Hanging clamp suitable for ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as specified and as directed by Engineer-in-Charge.
S&F louvers only for exhaust fan of size 300mm sweep made out of MS sheet 22 gauge complete all as specified and as directed by Engineer-in-Charge.
S&F louvers only for exhaust fan of size 450mm sweep made out of MS sheet 22 gauge complete all as specified and as directed by Engineer-in-Charge.
Supply only fan blade (set of 03) suitable for 1200 mm sweep all as specified and as directed by Engr-in-Charge.
Supply only fan blade (set of 03) suitable for 1400 mm sweep all as specified and as directed by Engr-in-Charge.
Supply only wall mounted fans blades suitable for 400/450 mm sweep any make and suitable colour including taking down all as specified.
Supply only exhaust fans blades suitable for 300/450 mm sweep any make and suitable colour including taking down all as specified.
Supply only exhaust fans blades suitable for 600 mm sweep any make and suitable colour including taking down, complete all as specified and as directed by Engineer-in-Charge.
Supply only Ball bearing suitable size of ceiling fan any type and size, complete all as specified and as directed by Engineer-in-Charge. Make : SKF/PNB/TATA/NBC.
Supply only Ball bearing suitable size of Exhaust fan any type and size, complete all as specified and as directed by Engineer-in-Charge. Make : SKF/PNB/TATA/NBC.
Supply only Ball bearing suitable size of wall maunted fan any type and size, complete all as specified and as directed by Engineer-in-Charge. Make : SKF/PNB/NBC/TATA.
M&L for checking of Energy Meters single/three phase 2/4 wire of any Make /type including testing , checking and reporting any tempering and intimate meter reading at time of electric meter testing & re-sealing complete all as specified and as directed by Engr-in-charge. (NOTE: Necessary transportation upto building testing and checking arrangements with equipment and metre calibration certificate shall be provided by contactor).
M&L for taking down unserviceable energy meter single phase from meter box after disconnecting all incoming and outgoing connection and deposite to MES store complete all as specified and as directed by Engr-in-charge.
M&L for taking down unserviceable energy meter 3 phase from meter box after disconnecting all incoming and outgoing connection and deposite to MES store complete all as specified and as directed by Engr-in-charge.
S&F single phase electronic energy meter 10-40A in poly carbonate body with LCD display in class 1.0 only kwh in meter box including making necessary electrical (incoming and outgoing) connection complete all as specified and as directed by Engr-in-charge. Make HPL/ L&T/Secure.
S&F three phase electronic energy meter 10-60A in poly carbonate body with LCD display in class 1.0 only kwh in meter box including making necessary electrical (incoming and outgoing) connection complete all as specified and as directed by Engr-in-charge. Make HPL/ L&T/Bentex.
Supply and fixing meter box made of sheet metal enclosure suitable for electronic energy meter Single/three phase complete grouted in wall and making incoming and outgoing connection complete including making good disturbed suface as per existing all as specified and as directed.
S&F in replacement of Gang box for 15 Amps socket complete including 15 Amps switch socket combination complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Gang box for 5 Amps socket complete including 5 Amps switch socket combination, complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix LED tube Rod T5 (icluding driver) 4 feet , SLETL DS 18 P T5,capacity 18/20 watt complete all as specified and as directed. Make - Surya or equivalent in Baja/Philips/Havells.
S & F in replacement of surface light to LED surfase light square 22 watt size 225 X225 X 40(H) complete all as specified and as directed. Make - Surya/Baja/Philips/Havells.
S&F in replaceemnt of fluorescent tube light fittings with new energy saving LED T 8 Tube light Fitting 4 feet clear cool white 20 Watt with inbuilt LED Driver, complete all as specified and as directed. Make : C&S Cat Part No.LT4F16WLEDt8/WD or equivalent in Baja/Philips/Havells.
Supply only Self ballasted Led Retrofit Bulbs with PBT Body shell and PC diffuser AELIUS LX LED LAMP 7 Watt BC 6500 K complete all as specified and as directed. cat part No - LLPO101029 Make - Crompton / phillips /Bajaj/Philips.
Supply only in replacement of indoor decorative LED batten light fitting 1x9/10W tube light fitting with 2 feet long LED Tube of 9/10W complete with all accessories internally prewired complete all as specified and directed by Engineer-in-Charge. Make:- Surya/Bajaj/ PHILIPS/ HAVELLS
Supply only Self ballasted Led Retrofit Bulbs with PBT Body shell and PC diffuser AELIUS LX LED LAMP 14 Watt BC 6500 K complete all as specified and as directed. cat part No - LLPO101029 Make - Cromption / phillips / Bajaj
S & F inreplacement of old wall bracket light to LED wall bracket light complete all as specified and as directed. HLWB-01-B22 Make Halonix/Havells/Syska
S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 6 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge. Make :-Plaza/Kalinga Premium/Polycab/Havells
Notes:- (a) The amount of Rs. 124305/- against Schedule of Credit on Page No. 113 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
PARKASH ENTERPRISES
NAVREET CONSTRUCTION
Saini Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .