Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.2 Cr+₹3.9 L (3.41%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹1.2 Cr+₹3.9 L (3.41%) | L2 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 3 | L3₹1.2 Cr+₹8.2 L (7.13%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | ₹1.2 Cr+₹8.2 L (7.13%) | L3 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CAT |
| 5 | Rejected-Technical FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | - | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CAT |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
12 Jan 2024, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT 110010
CWE/D-18/2023-24
2023_MES_630162_1
CWE/D-18/2023-24
Open Tender
Civil Works
Item Rate
270 days
DELHI CANTT
As per NIT
7 documents required · 7 mandatory
₹1,000
GE NORTH DELHI CANTT
₹2.0 L
Yes
1 Mar 2024
28 Nov 2023
13 Jan 2024
28 Nov 2023
12 Jan 2024
30 Dec 2023
Amount
M&L for Excavating in post holes (or similar holes) each n exc 0.5 cum (soft/loose soil) getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M/L PCC 1:2:4, type B2 using 40mm grade stone agg as in foundation/fencing post fixing all as specified and directed.
S & F for providing & fixing of roof with multilayer standing seam polycarbonate panels system of 16mm thickness (minimum) including all standard fixing accessories on top of the supporting structure (Paid extra in another item) complete & as per the direction . The panel should work on angular daylight concept with translucent and opaque combination of louver inside, for better thermal insulations and diffusion of light especially with white and clear combination designed for tropical regions & shdind through the day for better ambient temprature below the roof. Panels shall have minimum seven layers with all fixing accessories to ensure best performance for wind uplift , vibration, oil canning and visual appearance. The entire panel system shall be with a width from min. 1200mm. Bigger width and minimal junctions should be preferred for better performance. Panels shall be manufactured with vertical offset standing seam at both side of the panel. Panels have to be fixed on Purlin with snap on connector with grip ock double tooth locking mechanism and will be secured on SS structure/purlins with HDSS Fastner and double tooth polycarbonate connector for best stability and having a pull out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Panels cell structure be in truss bridge design or commonly called caed X structure for better strength and stability. Penals must satisfy dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycabonate Penal which have been exposed to UV for a min of 500 Hours as per ASTM G 155. Panels shall not have yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 55. U value shall not be more than 2.0 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/Glazing bar (all mill finish) for ends as required. Trained and factory authorised labour with supervision to complete the entire panel instalation as per drawing and direction of the engineer in charge. Color : A Combination of Clear/White or any colour in a single panel and as per approved sample.
Material & Labour for providing and fixing stainless steel (Grade 304) railing/rafter/purlins/truss made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
M&L PCC 1:4:8 type D-2 as in sub base of flooring 75 mm thick all as specified and directed by Engr-In-Charge.
M & L for sand filling thick under floors or in foundations including watering as required all as specified and directed by Engr-In-Charge.
M & L for machine pressed precast concrete interlocking payer block any shape and size confirming to IS -15658-2006 of 60 mm thickness (M-35 Grade) with grey cement and no pigment all as specified and directed by Engr-In-Charge.
M/L PCC 1:4:8, type D2 using 40mm grade stone agg as in foundation/fencing post fixing all as specified and directed.
M&L for PCC1:2:4 Type B-0 ( 12.5 mm graded aggregate) cement concrete in kerbs,slightly rounded or chamfered on edges complete all as spcified and directed.
Cutting openings, through brick walls built in CM for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. Removing to store and rubbish not exc. 50m complete all as specified.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing working CM (1:4), complete all as specified.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles. All as specified and directed by Engineer-in- charge
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and directed.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mean radius built in CM 1:6 but except bricks all as specified and as directed .
Taking down cement or cement lime plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubing down with water etc complete all as specified and directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors) beams, staircase, landing, chajjas and similar suspended work all as specified.
Reinforced cement concrete (nominal mix) TypeB0 1:2:4 (12.5mm graded aggregate) in Chajjas, complete all as specified and directed.
M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
Formwork to chullah hoods, chajjas, troughs and similar items including edges, complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing the serviceable tiles to store and rubbish off the premises etc complete all as specified and directed..
M&L for glazed ceramic coloured tiles of size 450 x 300 x 7mm thick on vertical surface such as dado, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including layer 10mm thick in cement mortar 1:4 complete all as directed and specified
'M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/rectengular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor, over 15mm thick screed bedding layer of mortar in CM 1:6 for laying floor finish complete all as specified and directed.
M&L for Vitrified Ceramic light shade tiles 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor, over 15mm thick screed bedding layer of mortar in CM 1:6 for laying floor finish complete all as specified and directed. .
M&L for Vitrified Ceramic light shade tiles 10 mm thick (Square/rectangular) polished area in vertical surface as skirting/dado of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor, and including layer 10mm thick in cement mortar 1:4 complete all as directed and specified .
S& F in repair composite pattern vitreous china wash down closet, One Piece Closet Western Commode, Hindware Cat part No 92503 or equivalent of make as given in approved make list ,including seat cover and all fittings Complete all as specified and directed.
S&F in repairs vitreous china, wash hand basin with Half pedestal , size 550x400x200mm including MS brackets including cutting and priming in with 32mm CP waste coupling and bottle trape complete all as specified and as directed.
S&F in repairs Single Lever Wall Mixer with Provision For Overhead Shower With 115mm Long Bend Pipe On upper Side, Connecting Legs & Wall Flanges complete all as specified and directed.
S&F in repair Single Lever Basin Mixer without Popup Waste System with 450mm Long Braided Hoses & Base Flange complete all as specified and directed.
S&F in repairs two way angle cock 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions.
S & F in repair 2 way bib cock with wall flange cast copper alloy C.P with non corrosive coating 15 mm bore screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union all as directed and specified.
M&L for rendering 15mm thick Ready mix Cement Plaster on faces of brick work or concrete surfaces (External ) finished even and fair complete all as specified.
Providing and applying plaster of Paris putty of 1 mm thickness over plasterd surface to prepare the surface even and smooth , complete all as specified and directed.
M & L for finishing walls with Acrylic Smooth exterior paint ( approved make) of required shade or colour ( approved by GE) over new plastered finished surface (Two or more coat [email protected] Ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) , Complete all as specified and directed.
M&L for rendering 10 mm thick Ready mix Cement Plaster on faces of brick work or concrete surfaces (Internal ) finished even and fair complete all as specified.
M&L prepartion of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer and 3mm thick of wall care putty of make birla/JK, all as specfied and directed.
M&L for rendering 5mm thick Ready mix Cement Plaster on concrete surface as in ceiling/chajja and reinforced cement concrete surfaces (Up to 6 mtr height )
M&L prepartion of newly plastered surface of Ceiling and distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work , all as specfied and directed.
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate, 75mm thick as in plinth protection / pavment and the like, finish the surfaces even and fair without using extra cement all as directed and specified
Demolition of stone slabe or tiles pf any description or thickness in floors aprons etc laid bedded and pointed in any mortar comlete all as specified and directed
M&L for 20 mm thick granite ( of any type ) work (table rounded and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 15mm thick screed bed in CM 1:6 including pointing in white cement 1:2 using marble dust with admixer of pigment to match with shade of granite complete all as specified and directed
Taking down chowkhats or frames with shutters n.exc 1.5 sqm each (without taking off shutters from the frame) all as directed.
Taking down chowkhats or frames with shutters exc 1.5 sqm but n.exc 4sqm each (without taking off shutters from the frame) all as directed.
S&F powder coated aluminium three track sliding windows with three sliding shutters (one gauzed shutter including 0.36mm dia and 1.18mm aperture stainless steel wire mesh and two glazed shutter including 4 mm thick plane glass panes) made of aluminium sections not less than 1.1kg per meter for bottom and top tracks, side track 0.98 kg per metre, bottom shutter frame 0.55 kg per metre, top shutter frame 0.47 kg per metre, shutter sides 0.47 kg per metre and interlock sides 0.45 kg per metre including suitable nylon beading, channel, gasket, nylon rollers, lock with handles etc complete all as specified and directed.
S&F Powder coated aluminium doors using 96.6 mm X 44.8 mm X 1.60 mm aluminium chowkhat, with 84 mm X 44.7 mm X 1.60 mm section vertical stile, with 101.60 mm X 44.8 mm X 1.60 mm rail mounted on floor spring with mortice lock, with aluminium tower bolts 150 mm long (02 nos), sliding bolt 300 mm long (01 no), door handle 150 mm long (02 nos) and fittings all as directed . Bottom panel with 12 mm thick laminated nova pan and top panel with 5.5 mm thick plain/froasted sheet glass with rubber beading of suitable size, complete all as specified and directed.
S&F aluminium anodised powder coated partition as all of aluminium section 100mm X 44mm X 2mm thick frame rectangular section & panel of 5mm thick PVC sheet in top & bottom pannel & 5.5mm thick sheet glass in middle panel with rubber linning & aluminium beading around length necessary fixing arrangements for bottom & top member of aluminium frame in floor / PCC /brickwork as per site requirement with rawl plug etc including chromium plated steel screws 60cm c/c including taking down old aluminium partition, complete all as specified.
Complete removal of old roof treatment including cement mortar bedding and removing debries out side MOD land ,( except mudfushka) , complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and Brushing neat cement slurry with 3.0kg of cement per sq. metre,complete all as specified and directed.
M&L for 15 mm thick cement screed bed over the concrete / brick roof surfaces in cement mortar 1:4 mixed with liquid water proofing compound @ 200ml per bag WPC (liquid type) , surface finished even and smooth without using extra cement all as specified and directed. Note :- Water proofing additive shall be measured and paid separately.
M&L for preparation of roof top surfaces by cleaning all the dust and loose material by brush/blower/Grinder including removing of vegetation/plantation from the surface and providing and applying single component elastic cold applied polyurethane modified acrylic roofing system, co elastic technology (CET) based on modified polyurethane and fully fibre reinforced, having Sun Reflectivity index (SR) of 109 on top of concrete roof surfaces. All cracks up to 3 mm at corner joints, channel and parapets should be treated with crack seal. Applying three coats including one coat of primer of ShaliUrethane BTD/ Sikalastic 560/ smart care damp proof-ultra having coverage @ min 0.75kg/m2 and dilution up to 10% and laying reinforced fiber net and applying two coats (without dilution) of shaliUrethane BTD/Sikalastic 560/smart care damp proof ultra @ total consumption 2 kg/m2 in two coats for maintaining minimum dry film thickness 1.5mm and elongation at break of free film of approx 350%. The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge/Consultant (Note :6 Hrs interval between two coat will be maintained). All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system. Make: STP/Sika/Asian paint or equivalent as approved by GE. Note:- (i) Application of water proofing treatment will be done by Authorised Applicator duly approved by GE in writing. (ii) The water proofing treatment shall be carried out by the manufacturer or their authorized applicators (iii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However, contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor' risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect
Supply only Liquid integral water proofing compound complete all as specified and as directed.Make: FOSROC or equiavalent
S & F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, as specified.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. all as specified and directed.
S&F glazing of tinted glass 5.5mm thick in aluminium door window shutters and partitions etc with PVC/neoprene gasket etc Complete all as per specified and directed.
S&F aluminium anodized barrel tower bolts of extruded section of length 150mm , complete all as specified and directed.
S&F aluminium handle cast type anodized 150mm, complete all as specified and directed.
S&F 300 mm length Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F 125 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc.,including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories)E53:E54
S&F PVC (SWR) pipes single socketed 110 mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed.
PVC (SWR) bends of 110 mm radius complete all as specified and directed.
M&L double action floor spring hydaulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of aluminium, other parts made of mild steel heavy duty and fixed in floor including cutting of floor for fixing of machine and make good in affected area complete all specified and directed
S&F in repair 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls and ceiling or laid in floor incl taking down all as specified.
S&F in repairs 20mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls incl taking down all as specified.
M&L for Cutting chases, pinning in Brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and ctting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
M&L for prepration of old surfaces by Complete removal of existing treatment & levelling of wall surface and applying two coats of Oil Bound Distemper over a coat of primer over 3 mm thick wall care putty on surface of wall. complete all as specified and directed .
M&L for preparation of old decorated previously treated surfaces of ceiling by brooming down scrapping down smoke and efflorescent etc. complete and applying one coat of white wash complete all as specified and directed.
S&F in repair Stainless Steel Curtain Rods of 20 mm dia incl brackets , side stop complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards /slabs/ blankets any thickness including cover fillets, Frame work etc all as specified and directed.
S&F GI powder coated frame work of size 605 x 605 mm, for celing comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre , hanging with 6 mm dia GI Hanger , complete all as specified and as directed.
M & L 4 mm thick size non asbestos fibre cement building boards fixed or laid / inserted to timber/ GI / Aluminiumframe work with screws complete all as per manufacturers instructions and as directed.
S & F solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent and fixing at site on PVC frame all as specified and directed by Engineer-in-Charge.
M & L for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as directed .
Dismantaling wrought iron or mild steel work of any description not otherwise provided for all as specified and direcred.
M&L framed work such as grills , gratings,laddar etc with ends of bars shouldered and /or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters ; walkways; railings; framework of watertanks and similar work etc confirming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L synthetic enamel paint on newly steel surfaces two coats over a coat of red oxide primer and preparation, complete all as specified and directed.
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
Excavation in trenches , not exc 1.5 m wide and n exc 1.50 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
M&L for RCC M-25 design mix concrete using 20 mm graded stone aggregate as in foundation including rafts footings , foundations beams, plinth beams, bases for coulmns etc basement slab, undereamed piles and mass concerte all as specified and dirceted
M&L for RCC M-25 design mix concrete using 20 mm graded stone aggregate as in column complete all as specified and dirceted
M&L for RCC M-25 design mix concrete using 20 mm graded stone aggregate as in slabs of any thickness above top of footing including attached pilasters and buttress complete all as specified and dirceted
M&L for RCC M-25 design mix concrete using 20 mm graded stone aggregate as in beams, cantilevers , bressummers , lintel over 1.5 m span complete all as specified and dirceted
M & L for Mild steel TMT bars 5 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders
M&L for Formwork to sides of flat concrete foundations, footings, bases of coullmns, raft and raft beams, sides and soffits of foundations and plinth beams and similar work complete all as specified and directed
M&L Formwork to sides of pilars post, struts piers , coloumn and stanchion of square , rectunglar or polugonal shape for rough finished surface of concrete complete all as specified and directed
M&L for Formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exc 200mm thick ( horizonla or sloping) for rough finished surface of concrete complete all as specified and directed
M&L for Formwork to sides and soffits of floor or roof beams , beam haunching girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc complete all as specified and directed
Returning , filling in incl spreading levelling and well ramming and watering in layers n exc 25 cm complete all as specified and directed
Removing excavated material soil to a distance exc 250 m but not exc 500 m and deposited where directed complete all as specified and directed
Spreading, levelling, laid in layers n'exc 25 cm thick and ramming including watering complete all as specified and directed.
M&L hardcore of broken stone or boulders of guage n.exc 63 mm deposted, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as speciffied and directed
M&L for 100mm thick cement concrete type D-2 1:4:8 (40mm graded agg) as in sub floor; complete all as specified and directed.
M&L 40 mm thick plain cement concrete 1:2:4 type B-1 ( using 20 mm graded stone aggregate) as in floors finished even and smooth using extra cement all as specified.
Supply only glass diving strips 3 mm thick and 38mm width inserted in position, confirm to design, complete all as specified and directed.
M&L for ATT, treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for ATT, treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed.
M&L for ATT, treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for ATT, treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for ATT, treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
S & F Gl frame work for step up and down designer seamless ceiling and wall lining comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long specing of hangers as per manufactures instructions complete in all respect as specified and directed. Note: work to be executed through authoried rep of manufacturer same shall be appeased by GE before incorporation in the work)
M & L for step up and down designer 10mm thick Gypsum anhydrous false ceiling & wall lining eleptical , half round or as approved design, shape & pattern fixed with screw including 2nd class HW fillets or metal frame work including GI wire mesh, Wire netting size of mesh 12 mm of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples etc or as per manufacturers instructions including taping form work etc complete in all respect as specified and directed.
M&L for applying 3 mm thick water proofing wall care putty as in ceiling on gyp board surface, rubbing and cleaning complete to get the surface even and smooth and applying two coats of OBD over a coat of primer including preparation of surfaces all as specified and directed.
Providing and fixing SPC flooring of Make: Sanvys / kronotex Dynamic, interlocking clip in system , underlying 2mm foam have to put before laying and at edges beading profile and door reducer profiles need to use with proper gapping to laminate planks of size 1380mm x 193mm x 3mm thick complete all as specified and as per manufacturer’s instruction including preparation of old floor surface.
Providing & laying ecoflex rubberized flooring tiles made of multi-layered SBR rubber crumbs minimum size 4-5mm on top and Larger size on crumbs on bottom bound together with high quality polyurethane based binder with beveled edges. Tile 25mm thick rubber tile in size 500mm x 500m density of 0.95+ 0.05 g/cm3, compressive stress (at 25 % reflection) of 19 + 2 kg/cm2, force reduction 24 % 3% (relaxation after 30 minutes)and should have value of 20 ± 5 as tested by an Government of India affiliated agency. When subjected to fire resistance test for cigarette burn, the tiles should not emit any smoke. Tiles should be of internationally accepted standard, supported by export orders. Tiles should be fixed with non-corrosive rubber based adhesive as specified by manufacturer including preparation of old floor surface.. Color:-Black/Terracotta
M&L 2 nd class hard wood Plain fillets in square,rectangular or triangular in section exc 13 but not exc 25 Sqcm, clean sawn, secured with nails or brads.
M&L for wood polymer composite (WPC) sheet Hybrid of size 8’x4’ x3mm thick fixing assembly clips as per manufacturer’s instructions all specified and directed.
M & L French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats
S& Fix 12 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to frame work complete all as specified and directed.
Supply,laying and testing cable XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, of size 3 core 185 sq mm complete all as specified and directed.
Supply,laying and testing cable XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, of size 3 core 95 sq mm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed.
Supply, Installation, Testing and Commissioning of 11kV, 630A, 21kA,SF6 Gas Insulated Extensible,Outdoor type compact switch gear with 03 Nos Motorized operated Load break switches, 05 Nos Motorized operated Vacum circuit breakers and 01 No Air insulated Bus PT metering panel (Configuration : CCCV+VVVV+M) complete (Make- ABB/C&S/Schneider)
(i) Technical general characteristics : Metalclad Compact Switchgear SF6 insulated type, Protection degree- IP4X , Suitable rating copper bus bar for Main and earth system, SF6 Tank Material Stainless Steel type with provn of standard interlocks. (ii) Motorized Operated load break switch with built-in earth switch, Mechanical position Indicator (ON/OFF/EARTHED), Live cable Indication, Cable termination bushing suitable for cable size upto 3Cx 300Sq mm XLPE cable with Cable termination cover boots (Push on type) (iii) Vacuum Circuit Breaker (VCB) Feeder Comprise of following:- 11kV, 630A, 21kA VCB with Motorized Spring charging mechanism & trip & closing coil for operation, Manually Operated 630A disconnector with built-in earth switch, Mechanical position Indicator (ON/EARTHED), CT with ratio (200-100/1-1A) Self-Powered 3O/C+1E/F Relay, Multifunction meter, Live Cable Indication, Cable termination bushing suitable for size upto 3Cx300Sq mm XLPE cable with Cable termination cover boots (Push on type). (iv) Common Items & Accessories for RMU :- Manometer with Green & Red zone for indicating pressure of gas inside the tank fitted on RMU, Battery charger, Operating Handle (Supplied Loose with RMU) Notes:-Rates deemed to be included for (a) Necessary earth work, PCC work, Platform for fixing of eqpt as per manufacturer recommendation, fair cement finishing for fixing of floor mounted RMUs and other misc works etc, required for fixing of eqpt.(b) Product training, site training, Tools needed for site services/operation.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx3.15mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete.(Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.)
Supply and fixing earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 20x3mm copper strip all as specified and directed.
S&F 4 mm dia MS wire 150x100 mm mesh, made upto into mattress or cages approx 2.0 mtr height and fixed with flat iron/angle by welding in position and directed including complete all as specified and directed. Note:- MS angle, MS flats, Nuts, Bolts and washer will be measured and paid separatly under relevant items.
M & L for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified.
M&L for MS work of angle iron channels and iron flats for post and struts of fencing around transformer plinth etc drilling holes, flat iron for securing wire mesh by welding to angle iron frame and framed work as in door/ gate of angle and wire mesh door to be fixed by 02 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified and directed.
S&f for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1998 grade St.-240 complete all as specified and directed.
S&F for pre- painted galvalume aluminum zinc coating GI based steel sheet of approved profile of corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
Removal of UNSV 4 pole structure of Prestressed Cement Concrete poles 11mtrs (04Nos) including GOD with insulators,Lightening arrester, earthing strip complete all as specified and directed.
M&L for sand cushioning for protection of cables with screen wash river sand and punning to proper required cover all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx 180mm x 40mm , as specified and directed
Supply, installing, testing and commissioning of Out door type, floor mounted step down transformer, 11 KV/433 Volts (at no load) AC 3 phase 50 Hz, 160 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +5% to -10%in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. Perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS 1180 (Part-I) : 2014, Energy Efficient Level -II and shall comprise of the following :-(a) One cable box on HT side (primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out 3 core 185 Sq mm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete.(b) One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable size/rating of cable complete. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel).
(e) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers.(f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0- 120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of earth strip for earthing of body.(h) Rating plate and terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral.(k) First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto required dielectric strength at 2.5 mm air gap between testing electrodes (l)Provn the angle iron channel for floor mounted Out door type transfomer as per site requirement. (m) Providing adequate size and nos of channels, embeded in platform floor, for movement of transformer.(n) Unidirectional roller wheel.(o) Other accessories as per manufacturer design. (p)The losses of transformers of intermediate rating should also fall in the respective bracket of maximum losses. The manufacturer has to render a certificate with details that their transformer losses at 50% load - 670 W as well as 100% load- 1950 W and doesnot exceed as per IS 1180 (part-I) : 2014 requirements. NOTE : (i)Transformer shall be supplied inclusive of initial oil filling to appropriate level of insulation oil with desired dielectric strength.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with using 32 x 6 mm galvanized MS strip by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 40mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete.(Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.)
M&L for earthing complete with galvanised mild steel earth plate electrode 30cmx30cmx3.15mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with using 20 x 3 mm galvanized MS strip by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 40mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete.(Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.)
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed.
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete
Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for up to required module etc complete and making good to the disturbed surfaces to match the existing complete all as specified and directed for for One light / bell point/one Ceiling / exhaust fan point/one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 5/6 Amps switch.
All as per above item no 142 here-in-before but one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per above item no 142 here-in-before but with point wiring 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 5 pin, 15 Amps socket outlet point on independent board controlled by one, one way 15 Amps switch
S&F switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
S&F switch piano type 2 way 5/6 Amp, 230 Volt, flush button complete all as specified and directed by Engineer -in-Charge.
S&F bell push, flush type, 06 Amps, 230 volts with switch frame complete
S&F switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, humfree, AC, 230 volts, 100 watts complete
S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete.
S&F decorative wall mounting light SS finish fixture with extruded glass difuser suitable for up to 40 watt mini glass lamp, lamp holder, including 9 Watts LED bulb having minimum efficiacy at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@ operating voltage 170V-240V for fixing in decorative wall mounting light and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete
S&F sueface mounting LED integrated aluminium housing batten luminaire not less than 18 W, 4 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete.
S&F sueface mounting LED integrated aluminium housing batten luminaire not less than 8 watt 2 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete.
S&F surface mounted LED building security light fitting in high pressure die cast aluminium housing not less than 20 watt fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V including light grade GI tube mounting size 40MM bracket of suitable size & length, bend to shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete and one coat of primer and one coat of synthetic enamel paint after coating of primer on GI bracket and pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core complete all as specified and as directed.
Supply and fixing of exhaust fan, steel body, AC, single phase, 230 V of size 300mm sweep with blades, frame & louver having 1400 RPM speed, 1600 CMH and including making of holes of suitable size and making good to the disturbed surfaces to match the existing complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete . and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directed
M&L for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring complete
Supply and fix electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element complete all as specified and as directed (Note : Old/ unsvGeysers to be deposited in MES store)
S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and sheet metal enclosure double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
S&F (in replacement) sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 415 volts, 04 ways with 200 Amps rated copper bus bar and metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Note :- MCCB & MCB SP will be measured seperately)
S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning by using suitable copper lugs complete:-
(a) SP 5 To 32 AMP
(b) SPN 40 to 63 AMP
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete.(Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.)
S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete
S&F modular bell push with indicator, 06 Amps, single pole, one way, 230 volts complete
S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete
S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete
S&F modular socket outlet 02 in 01, 03 pin, 16 Amps, 02 module with shutter complete
S&F ding dong bell, AC, 230 volts, single pole incl connection complete
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts incl connection complete
S&F ceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals complete
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete
Supply and fixing cuboid 400 mm remote controlled 3 blade ceiling fan with built in LED lights, fixing on grid ceiling suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete all as specified and directed
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 20 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed
All as as above item no 180 but for 02 x 4 Sqmm for phase & neutral and 01 x 4 Sqmm for continuous earth wire
S&F industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and sheet metal enclosure double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
S&F sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 415 volts, 04 ways with 200 Amps rated copper bus bar and metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Note :- MCCB & MCB SP will be measured seperately)
M P TYAGI ENGINEERS AND CONTRACTORS
RAVINDRA BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .