Tender Value
₹16.8 Cr
EMD Value
₹9.9 L
Closing Date
13 Feb 2026, 2:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Panel Interlocking or Route Relay Interlocking or Electronic Interlocking or IBH or Automatic Signalling or LC gate Interlocking.
9 conditions · 2 needing a document upload
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V & Annexure- V(A)of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home page of IREPS portal for works tenders before submitting the e-tender. 1.General Instruction for E-Tenders on works contract--Chapter- I 2.Special Condition-General- Chapter-II
Opening of e-tender : 1. The e-tenders will be opened online using the IREPS portal anytime after tender closing time. No representative is required to be present for opening of e-tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders through the website after the opening of the tender. 2. The earnest money cost is to be paid through online banking facilities through the online portal and by giving the other details online on website www.ireps.gov.in. Note: For more details refer to Cl: 4 & 12 of General Instruction-Chapter-I for Submission of EMD and opening of e-tender.
Asansol Division: Signal & Telecom work in connection with provision of 06 nos. IBPs to enhance Line Capacity of STN-JAJ Section.
34-SDSTE-ASN-2025-26~ER
34-SDSTE-ASN-2025-26
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹9.9 L
13 Feb 2026
22 Jan 2026
30 Jan 2026
318 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 14,61,75,937.33 | ||
| — | 4.00 | — | — | ||
| Supply, transportation, installation, wiring, testing & commissioning of Block proving by Axle counter using UFSBI & Block panel for double line operation as per RDSO specification No. IRS:S-105/2012( Ver .0) with latest version and amendment . This include supply of Block panel complete with block telephone & all accessories , relay rack and locking & sealing arrangement including supply of concern relays, SPD for commissioning of the system. Prewired relay rack with terminals, fuse & fuse base, busbar & other accessories to be housed in same UFSBI cabinet. The System should have facility to work on Quad and OFC with media auto changeover facility. It shall comprise media auto changeover facility for Quad & OFC working. Necessary modem for Quad and OFC should be supplied alongwith auto changeover arrangement. Execution includes transportation from consignee store to site including loading /unloading , fixing of equipment, wiring from CTR/Relay rack /Power rack, cabling from relay room to block panel etc. Material required for execution like PVC wires, terminals, wire & cable guide/channel/pipe , fixing materials etc. and drawings, documents as per OEM to be supplied by the contractor . Installation & commissioning works includes required floor/wall cutting, masonry work, earth work, painting, lettering . Installation , testing, commissioning of UFSBI to be done by OEM or OEM authorised representative as per RDSO specification. Inspection: RDSO | — | — | — | 49,44,200 | |
| — | 6.00 | — | — | ||
| Supply of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input & 16 analog input with DOT Matrix Printer,80 COL as per RDSO Spec. No. IRS (S) 99/2006 with Amdt. 3.0 or latest. It includes supply of all the items required for complete indoor relay room wiring from RTU to relay rack tag blocks, drawing/extension of power supply up to RTU. It includes supply of relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD (if installed), IPS, interlinking and networking of RTU. It also includes supply of leased line MODEM, suitable online UPS (minimum 6 hours' backup) and other interfacing cards, if required for networking of Data Logger. Note: (1) Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines of Railway Board/RDSO/Zonal Railway. (2) Exceptional reports are to be generated by a computer connected to datalogger at the station and at a central location in Control Room. Datalogger software should be able to generate exceptional reports for maintenance, safety and operations as per latest guidelines of Railway Board/RDSO/Zonal Railway. Datalogger to be installed at Site by OEM. Manufacturing date of RTU and printer should be of current year at the time of supply. Inspection: RDSO | — | — | — | 12,99,420 | |
| — | 6.00 | — | — | ||
| Installation, wiring, testing & commissioning of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input & 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 with Amdt. 3.0 or latest. It covers complete indoor relay room wiring from RTU to relay rack tag blocks, drawing/extension of power supply up to RTU. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & DG sets, ELD (if installed), IPS, interlinking and networking of RTU. All material required for wiring, networking, power supply monitoring, door-locking arrangement etc. will be supplied by contractor. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines of Railway Board/RDSO/Zonal Railway. Networking of data logger includes extraction of data report from Control room. Exceptional reports are to be generated by a computer connected to datalogger at the station, EI Huts, LC Gates, AFTC Huts etc. and at a central location in Control Room. Datalogger software should be able to generate exceptional reports for maintenance, safety and operations as per latest guidelines of Railway Board/RDSO/Zonal Railway. Datalogger to be installed at Site by OEM. For networking, required communication channel (Quad/ OFC cable) will be arranged/provided by Rly in SM/ASM's room or in OFC/TRelay room/IBH /LC Gates etc. and it will be extended by contractor up to location of data logger by using CAT-5/6 telecom cable with proper casing and capping. The contractor will supply all the material like CAT-5/6 telecom cable, casing & capping, nuts, bolts etc. The final commissioning will be done after filling up of Pre- Commissioning checklist (circulated by RDSO) with the OEM representative. Datalogger to be validated and commissioned before simulation test and put in network, validation statement should be jointly signed by railway engineer (open line), railway engineer (construction) & OEM'S engineer before simulation test with name, designation and date. Payment for this item will be released only after submission of duly signed pre-commissioning checklist of data logger in standard RDSO format, joint signature of validation statement. OEM'S engineer will also impart training to rly staff at site for proper functioning /working and applications of data logger. Inspection: Consignee. | — | — | — | 1,18,866 | |
| — | 9.00 | — | — | ||
| Alteration work of control cum indication panel to suit approved panel face diagram. All materials to be supplied by the contractor required for this work. This work includes laying ,termination of cable/wire from relays/CTR to panel and necessary lettering in panel. Cables/Wires required for this purpose to be procured from RDSO approved firm as per RDSO spec. and inspection by RDSO. | — | — | — | 5,73,045.12 | |
| — | 3.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards/relays/wiring material/connectors/fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied | — | — | — | 52,32,036 | |
| — | 12.00 | — | — | ||
| Modification, alteration of existing datalogger to suit the alteration work as per advice of Rly. Site engineer. This work includes validation, changes of NMDL software, wiring etc..For this work necessary wire from relay to tag block & from tag block to data logger, tagblock, terminal , soldering material etc. to be supplied by contractor. Wire to be procured from RDSO approved firm and to be inspected by RDSO. This modification to be done by engineer/representative of OEM of data logger. | — | — | — | 5,89,920 | |
| — | 9.00 | — | — | ||
| Design of circuits in connection with preparation of wiring diagrams as per approved Signalling Plan and submission of indoor as well as outdoor completion documents for alteration work. It includes Route Section Plan (RSP), Selection Table (ST), Locking Table (LT) and Control Panel Diagram (CPD). Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways, then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. All drawings will be prepared in CAD. The wiring diagrams will consist relay rack analysis, relay contact analysis, fuse details. Tag block analysis etc. A separate CD/Pen drive will be submitted to Railway for each station along with original tracings. It also includes preparation and supply of laminated one set of all completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets photo copies will be submitted for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection Table, Locking Table, Contact Analysis, Fuse and Tag Block Analysis of Relay Rack and CT Rack, Control Cum Indication Panel, VDU Diagram, Power Panel Diagram, Track Circuit Plan, Rack Erection Plan and Junction Box details etc. Note: Total cost of design and completion documents for a station/yard will be calculated on basis of total possible movements/routes as per Selection Table (ST). | — | — | — | 5,29,173 | |
| — | 6.00 | IBH/LC Gate/Auto Hut | — | ||
| Design of circuits and plans to suit layout given in the signalling plan of IBH.All plans and wiring diagram shall be prepared on Auto Cad Drawing and supplied with CD. This will include supply of Control cum Indication panel diagram, Route section plan, square sheet, wiring diagrams, Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Relay room tag block analysis, panel tag block analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement with program switch, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings. NOTE: The contractor shall initially supply 2 sets of documents (Paper Prints) for approval of Railways. Railway will return one set to the contactor duly approved with alterations/corrections, if any. The contractor shall incorporate Railways' alterations/ corrections/ comments, if any, in the tracing & CD without any deviation and submit all the tracings and Final CD complete with all respect for Approval of Railways. After Approval of Railways on the tracings, the contractor shall submit 3 sets of final approved diagrams to the Railways within 15 days. He shall ensure that each sheet has a block for signature of railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each IBH | — | — | — | 73,284 | |
| — | 200.00 | — | — | ||
| Carrying out relay alteration to the existing relay wiring/ new relay wiring at relay racks of existing station as per the approved circuit diagram. This work includes the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection by RDSO. All required materials like wire, soldering materials, paint etc. to be supplied by the contractor for execution of the work. | — | — | — | 54,000 | |
| — | 6.00 | — | — | ||
| Supply , installation of A class lightning arrester system alongwith supply of all required materials as per Annexure-1. Inspection : RITES | — | — | — | 38,22,030.18 | |
| — | 12.00 | — | — | ||
| Supply, installation, commissioning of AC in relay room having split type,5 STAR rating Air Conditioners of minimum 2 Ton capacity (HITACHI/DIAKIN / bluestar, voltas make). All required Socket, cable etc. to be supplied by contractor. Inspection: Consignee. | — | — | — | 12,66,280.68 | |
| — | 16.00 | — | — | ||
| Supply of colour light signal post 3.6 mtrs. and ladder 3.5 mtrs. With bases for ladder and post as per RDSO SPEC. NO. IRS-S-6-81 and DRG. NO. SA-23153/ADV/AIT-1. All drawing should be as per latest. Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Inspection: Consignee . | — | — | — | 2,51,632 | |
| — | 20.00 | — | — | ||
| Supply of colour light signal post 4.6 mtrs. and ladder 4.5 mtrs. With bases for ladder and post as per RDSO SPEC. NO. IRS-S-6-81 and DRG. NO. SA-23153/ADV/AIT-1. All drawing should be as per latest. Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Inspection: Consignee . | — | — | — | 3,19,000 | |
| — | 36.00 | — | — | ||
| Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips as per DRG. NO. S&T/C-42(NKG). | — | — | — | 2,90,340 | |
| — | 20.00 | — | — | ||
| Supply of CLS (colour light signal) unit FRP 2 Aspect complete without lens, lamps and signal transformer as per Drg. No. SA 23003/A/M(ADV.) or latest & RDSO/SPN/194/2006 or latest and as per FRP Spec. no RDSO/SPN/151/1997 or latest .(Signal unit to be compatible to LED lighting unit). Inspection: Consignee. | — | — | — | 5,31,660 | |
| — | 20.00 | — | — | ||
| Installation, erection and wiring of CLS 2 aspect unit FRP , post, ladder & base complete including paying out of tail cable from location box as per Rly. site engineer. Note:- This includes installation, erection & wiring of signal unit includes fixing, wiring of LED signal lighting unit, current regulator and this also includes protection of unit from rain water. For Installation, erection and wiring all materials including nuts, bolts to be supplied by contractor except Signal post, ladder, base, unit, earth pipe & LED lighting unit. Signal post, ladder, base, unit, LED lighting unit will be supplied by Rly. | — | — | — | 33,160 | |
| — | 16.00 | — | — | ||
| Supply of CLS (colour light signal) unit FRP 3 Aspect complete without lens, lamps and signal transformer as per Drg. No. SA 23002/A/M(ADV.) or latest & RDSO/SPN/194/2006 or latest and as per FRP Spec. no RDSO/SPN/151/1997 or latest .(Signal unit to be compatible to LED lighting unit). Inspection: Consignee. | — | — | — | 4,36,944 | |
| — | 16.00 | — | — | ||
| Installation, erection and wiring of CLS 3 aspect unit FRP , post, ladder & base complete including paying out of tail cable from location box as per Rly. site engineer. Note:- This includes installation, erection & wiring of signal unit includes fixing, wiring of LED signal lighting unit, current regulator and this also includes protection of unit from rain water. For Installation, erection and wiring all materials including nuts, bolts to be supplied by contractor except Signal post, ladder, base, unit, earth pipe & LED lighting unit. Signal post, ladder, base, unit, LED lighting unit will be supplied by Rly. | — | — | — | 37,632 | |
| — | 15.00 | — | — | ||
| Supply of red aspect main colour light signal LED lighting unit compatible with LED ECR as per RDSO Spec. No. RDSO/SPN/199/2010, Rev1.1 or latest. Inspection: RDSO | — | — | — | 1,25,430 | |
| — | 40.00 | — | — | ||
| Supply of Yellow aspect main colour light signal LED lighting unit compatible with LED ECR as per RDSO Spec. No. RDSO/SPN/199/2010, Rev1.1 or latest. Inspection: RDSO | — | — | — | 3,35,480 | |
| — | 40.00 | — | — | ||
| Supply of green aspect main colour light signal LED lighting unit compatible with LED ECR as per RDSO Spec. No. RDSO/SPN/199/2010, Rev1.1 or latest. Inspection: RDSO | — | — | — | 3,77,520 | |
| — | 36.00 | — | — | ||
| Supply, Fabrication and Fixing of Retro reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post and as per standard practice. Inspection: consignee | — | — | — | 13,428 | |
| — | 36.00 | — | — | ||
| "Supply and installation of P/ C / G/IB marker (size 250mm dia circle) high intensity prismatic (TYPE-IV) retro reflective sheet over 2 mm thick aluminium sheet & letter will be screen printing (250 mm dia circle) as per drg. S&T/SDAH/SK-1383 and technical specification attached. This will include cost of all materials including fixing clamp required for this work. Inspection: - consignee" | — | — | — | 19,800 | |
| — | 30.00 | — | — | ||
| Supply of Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDGH"". Inspection authority: - RDSO" | — | — | — | 1,15,350 | |
| — | 450.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc. and conforming to BRS- 930 and RDSO Specn.No. IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be ""ABCDF"". Inspection authority: - RDSO" | — | — | — | 16,81,650 | |
| — | 95.00 | — | — | ||
| Supply of Q-Series LED ECR (Universal Type i.e.QECX-61), 4F/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09- 2002 ,Amdt.-1 and RDSO Specn.No.IRS:S-34 & S-23 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be ""ABDHK"". Inspection:- RDSO | — | — | — | 4,66,640 | |
| — | 100.00 | — | — | ||
| Carrying out relay alteration to the existing relay wiring/ new relay wiring at relay racks of existing station as per the approved circuit diagram. These works include the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. IRS:S- 76/89 or latest and inspection by RDSO. All required material like wire, soldering material, paint etc. To be supplied by the contractor for execution of the work." | — | — | — | 27,000 | |
| — | 96.00 | — | — | ||
| Supply, Transportation, Installation, Testing and Commissioning of Multi Section Digital Axle Counter (MSDAC) for mentioned detection Point by the purchaser & Track Section as per SIP uploaded with the tender, complete with all accessories, cable required with each track device & Card viz., Axle Detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre-fabricated Rack to be supplied along with the system), Reset unit, Relay unit, Event logger & Diagnostic terminals etc. required for different Detection Points & Track Sections as per RDSO Specification No. RDSO/SPN/176/2013, Ver.3 or latest and as per technical detail given in Annexure-2." | — | — | — | 3,28,85,568 | |
| — | Breakup | for details. | — | ||
| Earthing of S&T equipment, relay rack and power equipment etc. along with supply of all requisite materials. Earthing shall be in the form of Ring Earth/Perimetric earth conforming to RDSO spec RDSO/SPN/197 Ver.1.0 or Latest and as per latest TAN of RDSO No. RDSO/TAN/3006, Ver 3.1 of Earthing and Bonding system. The earthing shall be maintenance free. The ring earth/perimetric earth shall be connected to copper flat of size 25x2 mm ( BRC) in the relay room and IPS room. The copper flat fixed on the wall to the entire breadth of Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. Supply, installation commissioning of this work of Earthing and Bonding system to be done at 15 nos. locations ( station/cabin/hut) as per RDSO/TAN/3006, Ver 3.1 with latest amendment with item details given in break up | — | — | — | 35,37,450 | |
| — | 15.00 | — | — | ||
| Supply of fault analyser terminal consisting of PC i3 12100 8 GB/ 512 GB SSD/ WINDOW 11 WITH MINIMUM 19.5 inch LED display Make: ACER/HP/DELL/LENOVO | — | — | — | 6,95,100 | |
| — | 6.00 | — | — | ||
| Supply,erection,testing and commissioning of automatic fire detection and Alarm system (AFDAS) as per RDSO specification No. RDSO/SPN/217/2016 version no 1.0 or latest at whole IBP Equipment room, relay room,power supply room and cable troughs as per the instruction of engineering- in -charge.This also includes one year maintenance after the commissioning of system.Note:-All the material required for replacement/repairing during the maintenance of system will be supplied by contractor.Inspection:- RDSO | — | — | — | 26,77,080.6 | |
| — | 12.00 | — | — | ||
| Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 operating temperature (-30) ° to (50)° for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bend horn complete in all respect. Inspection: Consignee | — | — | — | 62,112 | |
| — | 13.00 | — | — | ||
| Supply of relay rack to accommodate 100 relays complete with fittings as per DRG.NO.S&T/C-20/2001 or latest Inspection: Consignee | — | — | — | 3,31,955 | |
| — | 13.00 | — | — | ||
| Erection, Installation , wiring of relay rack as per instruction of Rly site engineer and as per Drg. No. S&T/C/20/2001(modified). This work include ssupply of fuse block with fuse, bus bar, PBT terminal /Tagblocks, resistance, diodes, condensers, PVC wire as per RDSO Spec. No. IRS-S- 76/89(Amd-3) or latest (for wiring/inter-wiring of relay racks, CTRs, tagblocks) hylum sheet and other scaffolding materials to be supplied by contractor as per requirement. PBT terminals, PBT fuse block,fuse, PVC wire to be procured from RDSO approved firm and to be inspected by RDSO. This work includes fixing of relays with base , interconnection wiring with ladder arrangement of relay rack and complete wiring of relays by soldering/termination of wire at relay base as per wiring diagram and fixing of fuse block, diodes, resistance, condensers, terminal blocks, bus bars and other equipments required for the approved system design complete with supply of erection materials. This also includes laying , dressing of cables, wires for relay rack, CTR, panel, IPS/power equipment with supply of thread, wire guide, ladder guide , masonary materials and reinstatement of floor, wall as per requirement. This includes status of relay to be indicated through LED indication on top of rack, lettering of each relay on rack strip and lettering/numbering of terminals, fuse for circuit used in brief. Rack to be fixed on rubber pad. Ladder arrangement to be done from relay rack, panel, IPS/power equipment as per requirement. Ladders and its accessories for this work to be supplied & fixed by contractor. | — | — | — | 10,79,416 | |
| — | 6.00 | — | — | ||
| Supply of CTR (cable termination rack) as per drg no. S&T/C-19/2001with supply of screwless disconnect type terminal 2 way/4 way , scaffolding materials, ladder for supporting cable, wire guide, NDT fuse with fuse block, lugs, sleeves , PVC wire as per specification No. IRS-S- 76/89(Amd-3) or latest(for wiring of CTR) and other necessary hardware as per Rly requirement and supply of erection materials. Terminals, PBT fuse block, PVC wire to be procured from RDSO approved firm and to be inspected by RDSO. Inspection of CTR: consignee | — | — | — | 2,69,544 | |
| — | 6.00 | — | — | ||
| Installation, erection, commissioning of CTR as per instruction of Rly site engineer and as per Drg no. S&T/C-19/2001orlatest with fixing of scaffolding materials, terminals, fuse block, wire guide, ladder guide for supporting outdoor cables, wires. This includes termination of outdoor cable on terminals with proper lugs, number sleeves as per diagram and laying, dressing of cables, wires including earthing of cable armours properly. This also includes lettering/numbering of terminals for circuit used in brief. | — | — | — | 34,740 | |
| — | 4.00 | — | — | ||
| "Supply of PVC insulated Railway Signalling multicore Indoor Cable 60 core (0.6mm dia) conforming to IRS:76/89(Amd3) or latest. Inspection: RDSO | — | — | — | 6,04,128 | |
| — | 6.00 | — | — | ||
| Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5 sq.mm) as per IS 694:2010 and RDSO Specn. No.IRS: S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: RDSO | — | — | — | 46,014 | |
| — | 15.00 | — | — | ||
| Msonry job for Cutting of wall for insertion of cable at locations along with repairing of wall with brick, sand and cement after laying of cables as per instruction of site engineer. All masonary item to be supplied by the firm . | — | — | — | 4,395.3 | |
| — | 6.00 | — | — | ||
| Supply, Installation and Commissioning of SMPS based Integrated power supply (IPS) system for IBH in RE area with 200 AH LMLA battery with rack for battery as per RDSO Spec. No. RDSO/SPN/165/2023 (Ver.4.0) ,Amend-I or latest and as per typical diagram in Annexure-III of RDSO specification alongwith tool Kit & spare parts as mentioned in RDSO specification. Required modules/converters of IPS approved by Rly.Engineer will be given before supply of IPS. Installation, commissioning of IPS to be done as per RDSO specification by OEM or authorised representative of OEM. Inspection: RDSO. | — | — | — | 35,36,634 | |
| — | 40.00 | — | — | ||
| Supply of IPS DC-DC converter 24-32V DC, 5 Amp /10 Amp or 60-66 V DC, 5 Amp or 60-100V DC,1 Amp/3 Amp/5 Amp as per specification No. RDSO/SPN/165/2012, version- 3.0 or latest. Make: M/s. Statcon Ltd./ M/s. HBL Ltd./M/s. Amara Raja Ltd. Or Other RDSO approved make, compatible to fit & work with the existing IPS. Make of IPS for which DC-DC converter is procured and Vol/Current rating of required DC-DC converter will be specified by Rly. site Engineer before supply. Inspection: RDSO | — | — | — | 9,74,040 | |
| — | 50.00 | — | — | ||
| Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. | — | — | — | 2,68,500 | |
| — | 100.00 | — | — | ||
| Supply of Fuse, non-deteriorating(2A/6A/10A/16A) type, cylindrical (IRS-S-78/92). Inspection: RDSO | — | — | — | 6,100 | |
| — | 50.00 | — | — | ||
| Supply of fuse block (PBT) to spec.no.IRS-S- 75/2006(REV-2) OR LATEST, DRG.NO.SA- 23748. Inspection: RDSO | — | — | — | 8,900 | |
| — | 6000.00 | — | — | ||
| Construction and fixing of RCC cable duct (pre-cast) for cable laying in station yard (this includes laying of cable through cable duct as per site engineer) as per drawing no. ds/35/2012 or latest | — | — | — | 2,24,52,000 | |
| — | 160.00 | — | — | ||
| Excavation of trench as per cable route plan in all kinds of soil (1.2 mtr. Depth and 0.3 mtr. to 0.6 mtr width at bottom) and refilling of the trench without bricks and final back filling, ramming and consolidation of soil as well as the disposal of the soil, if any. Note:- Payment will be made as per actual work done on pro-rata basis, if the required depth is not available at site. If the depth of trench is not uniform in a span of 100 M or shorter lengths if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment. Prior permission should be taken from field Officer before laying of cable if the depth of trenching is less than 1.2 mtr. and duly mentioning location, length etc. in site register. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. For all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. | — | — | — | 2,13,24,705.6 | |
| — | 105.00 | — | — | ||
| Laying of S&T cable of various core sizes as per cable route and cable core plan approved by Railway and meggering of all main & Tail cables. The work to be done as per instruction of Rly. site engineer. Note: All materials (except cable) required for the execution of the work shall be supplied by the contractor. | — | — | — | 9,33,446.85 | |
| — | 8000.00 | — | — | ||
| Transportation of HDD machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) three (03) nos. of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum - 02 nos. Note: - cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer. | — | — | — | 1,40,64,000 | |
| — | 500.00 | — | — | ||
| Excavation of trench (1.2 mtr. depth from rail flange/road level and 0.3 mtr. to 0.6 mtr. wide, earth work and backfilling after placing DWC/RCC/GI pipe ( placing of DWC/RCC/GI pipe covered separately) , re-instatement of track while track crossing for laying of cables. The ballast disturbed to be screened and dressed and road tarred immediately. This work to be done as per instruction of Rly. Site engineer. All materials (except cable, DWC/RCC/GI Pipe) required for the execution of the work shall be supplied by the contractor. Note: If required depth can not be achieved at particular location, then alternative location to be selected as per instruction of Rly. site engineer | — | — | — | 68,210 | |
| — | 6000.00 | — | — | ||
| Supply of Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (2-meter-long) along with collars as per IS No. 458/2003 of NP type. Inspection: RITES | — | — | — | 40,74,000 | |
| — | 12000.00 | — | — | ||
| Laying of half round RCC pipe after laying the cables in the trenches. | — | — | — | 2,64,000 | |
| — | 1500.00 | — | — | ||
| Supply of full RCC Pipe 150 mm internal dia alongwith collars as per IS No. 458/2003 of NP type | — | — | — | 3,75,000 | |
| — | 1500.00 | — | — | ||
| Placing / laying of full RCC Pipe alongwith collars in trenches, road / track crossing etc. | — | — | — | 46,500 | |
| — | 2000.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 or Latest with socket & coupling. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: RITES | — | — | — | 15,24,000 | |
| — | 2000.00 | — | — | ||
| Laying & Fixing of Medium class GI pipes 50/100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. | — | — | — | 1,96,000 | |
| — | 2500.00 | — | — | ||
| Supply and fixing of RCC Cable Route Marker as per ER Drawing No. SI- S&T/1/2024(Sheet-1) and ER technical policy circular no. 108. Inspection of supply: Consignee. This item is a composite type work | — | — | — | 10,42,500 | |
| — | 50.00 | — | — | ||
| Cement concrete work for miscellaneous items/ works in the ratio 1:3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). | — | — | — | 1,79,800 | |
| — | 1000.00 | — | — | ||
| Cutting of platform / floor surface/ concrete surface for a depth of 20 cm & width of 10 cm & refilling / reconditioning/repairing the surface after laying of pipe, cable. Cutting to be done with machine in proper manner & restore the same as before. | — | — | — | 2,90,700 | |
| — | 170.00 | — | — | ||
| Supply of Earth Electrodes mild steel galvanized , light class , as per Specification No. IS:1239(Part-I)-1979 and as per PCSTE/ER's Drg. No. SI/TYP/0097 dated 25.03.25. Earth electrode pipe should be 3 mm thick, 50 mm dia. and perforated ( staggered) with 5 mm dia holes 2 nos. per 305 mm length alongwith supply of CI threaded cap, nuts, bolts, other materials as mentioned in Drg. No. SI/TYP/0097 . Earth electrode pipe to be galvanised after drilling and fabrication. Inspection: Consignee. | — | — | — | 2,54,320 | |
| — | 170.00 | — | — | ||
| Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends Inspection :consignee. | — | — | — | 1,54,870 | |
| — | 170.00 | — | — | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or cable for apparatus cases, signal post & other equipment as per guideline mentioned in PCSTE/ER'S DRG. NO. SI/TYP/0097 with provision of alternate layers of charcoal /coal and salt . Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. As per requirement MS flat may be joined by welding to increase length or to be cut & drill hole to shorten the length. All hardware and other miscellaneous materials required for installation to be supplied by the contractor | — | — | — | 1,97,370 | |
| — | 170.00 | — | — | ||
| Provision of cement concrete enclosure of size 450 mm x 450 mm x 300 mm and 75 mm thick for earth electrodes as per PCSTE/ER'S DRG. NO. SI/TYP/0097 dated 25.03.25. This includes supply of all materials by the contractor duly inspected by consignee. | — | — | — | 97,070 | |
| — | 20.00 | — | — | ||
| Supply & installation of maintenance free earth. This work includes ( 1) Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No.SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL,IEC to be produced. It consist of following: (a) Copper bonded steelel ectrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3nos. (c) Copper strip of 150x25x6mm, to terminate earth rod = 1no. (d) Copper strip of 300x25x6mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1no. (ii) Supply of 35 sq. mm multistrand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room induplicate.(minimum 10 meter) (iii)Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB(minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable . Inspection: RDSO. (2) Installation of Unit Maintenance Free Earth as supplied in above item. It includes( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30Kg) (iv) Provision of exothermic weld connections to copper tape of25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface(minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor asper RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No.SDO / RDSO/ E&B/001 or Latest. | — | — | — | 4,34,520 | |
| — | 120.00 | — | — | ||
| Supply of full size apparatus case(Large) (as per DRAWING NO.RDSO/S-11500. This includes supply of location box (GKP type)with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg .No. 3377 as per RDSO drawing No. RDSO/S-11500. Inspection:RITES . | — | — | — | 16,69,920 | |
| — | 120.00 | — | — | ||
| Casting, concreting, curing and plastering of concrete foundation for full size location box (GKP type)with Cement, sand, Stone Chips in the ratio 1:3:6 and erection of full size apparatus case(location box) as per Drg. NO.S&T/C-6/98(NKG). All materials required for this purpose including holding down bolts, nuts, washer, concreting materials etc. are to be supplied by the contractor. Materials to be inspected by Rly. Site Engineer and the work will be executed as per instruction of Rly. site engineer. Note:-location boxes to be painted with anti corrosive paints ( Asian paint/Berger/Shalimar) as per IS:-9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. | — | — | — | 4,23,840 | |
| — | 120.00 | — | — | ||
| Fixing of slotted angle, Bakelite strip, hylam sheet, fixing and wiring of terminals, relays, fuse with base etc. and fixing of shelves in Full size steel Apparatus cases(location box) with termination, dressing & bunching of cables/wires, earthling of cables and wiring with necessary lettering as required including supply of wires, slotted angles, ferrules for marking, misc. materials as required per location box. All materials except relay, terminal strips, bakelite strip, fuses with base, charger, D type resistance, B type choke, SSDAC equipment, surge arrester, battery and hardwood shelves to be supplied by the contractor. Wires to be procured from RDSO approved firm as per RDSO Spec. and to be inspected by RDSO. This includes sand filling and plastering over sand filling. NOTE: All locations to be provided with lamp/holder, switch for lighting as desired by Site Engineer. This should include all Terminations of Cable complete. Cable conductors are to be terminated with proper lugs and required bussbar and other terminals to be supplied by the contractor. | — | — | — | 5,79,600 | |
| — | 6000.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, 4-wirefront entry (Two in-put & Two out-put) as per RDSO Spec. No. RDSO/SPN/189/2004. The colour will be decided by Engineer - in -Charge. (Preferably In Blue, Red &Grey Colors in the ratio of 1:2:3).Inspection: RDSO | — | — | — | 3,30,000 | |
| — | 600.00 | — | — | ||
| Supply of end stopper to use with above Disconnect Terminal Block. Inspection: Consignee | — | — | — | 6,000 | |
| — | 200.00 | — | — | ||
| Supply of end plate to use with above Disconnect Terminal Block. Inspection: Consignee | — | — | — | 2,000 | |
| — | 200.00 | — | — | ||
| Supply of steel Carrier Rails for placing disconnect type terminal of size 35mm x 7.5mm, 1mm/0.039in thickness un-slotted type for placing disconnect type terminals. .Inspection: Consignee | — | — | — | 21,800 | |
| — | 15.00 | — | — | ||
| Supply of Office table with laminated top with three drawers on left hand side and one locker on the right-hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm) or Similar of reputed brand. Inspection: Consignee | — | — | — | 1,93,290 | |
| — | 60.00 | — | — | ||
| Supply of Office Chair make Godrej CH-7B or similar of reputed brand. Inspection: Consignee | — | — | — | 1,74,120 | |
| — | 15.00 | — | — | ||
| Supply of Office Revolving Chair Godrej Make Model No.9U02R Bravo or Similar of reputed brand. Inspection: Consignee | — | — | — | 1,35,480 | |
| — | 15.00 | — | — | ||
| Supply of Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand. Inspection: Consignee | — | — | — | 2,57,445 | |
| — | 9000.00 | — | — | ||
| Transportation of various S&T materials requiring use of truck / trailor including loading , unloading, lift, ascent ,descent and staking the same with a free lead of 150 mtr. after unloading as per instruction of Rly. Site engineer. | — | — | — | 97,380 | |
| — | 600.00 | Man-Days | — | ||
| Supply of labour( helper) for varios S&T works as per site requirement,, in joint block/work programme, for infringement clearence etc. as per instruction of Rly. site Engineer , for assistance to Rly. staff/ inspectors/officers during supervision of field work , in taking measurements, by acting as look out men, chowkidars, patrolmen etc and to assist in office work as per instruction of engineer-in-charge or his representative. For safety related works, competency will be ensured by the Rly. site Engineer. The Rly. site Engineer concerned will maintain proper record of supply of labourers by the agency. | — | — | — | 3,06,666 | |
| — | 400.00 | — | — | ||
| Rapid maintenance & repairing of laid cable/existing cables / exposed cables / cut cables during site work as per instruction of Rly. site engineer. The maintenance & repairing gang should have their own maintenance & repairing tools and measuring instruments and they should comprises of (1) one highly skilled staff(ii) one skilled staff & (iii) two un-skilled staff for this purpose of work. All materials for the maintenance & repairing of laid cable/existing cables / exposed cables / cut cables will be supplied by railways. | — | — | — | 11,79,716 | |
| — | 10.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 1000.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .