| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.7 LAccepted-AOC | L-1 | Accepted-AOC Being L-1. | |
| 2 | L-2₹31.4 L+₹27,813.30 (0.89%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L-2 | Rejected-Finance Not being L-1. | |
| 3 | L-3₹31.5 L+₹37,839.30 (1.22%)Rejected-Finance C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-3 | Rejected-Finance Not being L-1. | |
| 4 | L-4₹31.6 L+₹50,990.80 (1.64%)Rejected-Finance | L-4 | Rejected-Finance Not being L-1. | |
| 5 | L-5₹33.5 L+₹2.4 L (7.63%)Rejected-Finance | L-5 | Rejected-Finance Not being L-1. |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 861 EWS
GE 861 EWS
BR AND EM REPAIRS TO CERTAIN BLDGS AT VARIOUS LOCS OF HQ 5 SECT RR AND ITS ALLIED UNITS AT AWANTIPUR UNDER GE 861 EWS
2024_MES_660374_1
GE 861 EWS-29/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹96,000
Yes
14 Oct 2024
18 Jun 2024
23 Jul 2024
18 Jun 2024
16 Jul 2024
2 Jul 2024
Amount
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F 6mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with screws to timber frame work on ceiling only complete all as specified and directed.
Dismantling timber scantlings (unframed) in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
S&F 2nd class hard wood Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads exc 13 Sqcm and n exc 25 sqcm complete all as specified and directed.
S&F 2nd class hard wood Plain fillets. square, rectangular or triangular in section, clean sawn, bull nosed, splayed, chamfered or rounded on one edge or face secured with nails or brads exc 6 Sqcm and n exc 13 sqcm complete all as specified and directed.
S&F 2nd class hard wood Plain fillets. square, rectangular or triangular in section, clean sawn, bull nosed, splayed, chamfered or rounded on one edge or face secured with nails or brads n exc 6 sqcm complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Non - skid joint free coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar (1:4) complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick, light colour (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar (1:4) complete all as specified and directed.
M&L for Coloured Glazed joint free ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering of cement mortar (1:4) complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges and the like, fixed with self tapping screws as specified as specified complete all as specified and directed.
Demolition of Concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 100mm thick cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in sub base of floor finished even and fair (without using extra cement) complete all as specified and directed.
M&L for 100mm thick cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in sub base of floor finished even and fair (without using extra cement) complete all as specified and directed.
M&L for glossy finished chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20mm thick screed bed of cement mortar (1:4) complete all as specified and directed.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways for light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Taking down cement or cement lime plaster any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for 15mm thick rendering on fair faces or other than fair faces of brick or concrete surfaces of walls in cement mortar (1:4), surface should be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and as directed.
Dismantling water tanks exc 500 ltrs and n exc 1000 ltrs capacity and removing to store/credit to contractor complete all as specified and directed.
Dismantling water tanks exc 250 ltrs and n exc 500 ltrs capacity and removing to store/credit to contractor complete all as specified and directed.
Dismantling water tanks n exc 250 ltrs capacity and removing to store/credit to contractor complete all as specified and directed.
S&F 1000 ltrs capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F 500 ltrs capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F 250 ltrs capacity Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F in repair 15mm bore Stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 20mm bore Stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair small fittings of galvanised iron medium grade such as socket / elbow / nipple of different sizes / Tee / union / reducer etc for 15mm bore pipe complete all as specified and directed.
S&F in repair small fittings of galvanised iron medium grade such as socket / elbow / nipple of different sizes / Tee / union / reducer etc for 20mm bore pipe complete all as specified and directed.
S&F in repair 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Taking up or down 15mm bore galvanised steel tubing and connections, including cleaning for re fixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore galvanised steel tubing and connections, including cleaning for re fixing or removal to store complete all as specified and directed.
S&F 15mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs 15mm bore Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm- 125gms). complete all as specified and directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repairs 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F in repairs 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F in repairs 75mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F in repairs 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F 20mm dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc. includind taking down of existing tubing of any size and type complete all as specified and directed.
S&F in repairs Vitreous China urinals, size of 465 x 355 x 265 mm white (minimum) bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in white or coloured cement to match complete all as specified and directed.
Taking down carefully aluminium/copper point wiring (light fan socket or power) complete including making good disturbed surfaces of walls, floor to match with existing and keeping items aside for credit complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including PVC casing and capping medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS/ wooden sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
Description all as per srl item No-49 here in above but for one 3 pin 5A socket outlet on independent controlled by one switch complete all as specified and directed.
Description all as per srl item No-49 here in above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed.
Description all as per item No 49 above but for 3 pin socket outlet 15 Amps on independent board with 2.5 Sqmm complete all as specified and directed.
S&F in replacement switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified and directed.
S&F in replacement for switch socket combination 5 amps 5 pin flush type, 230 volts complete all as specified and directed.
S&F in replacement for switch socket combination 5/6 amps 5 pin flush type, 230 volts with box complete all as specified and directed.
S&F in replacement switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified and directed.
S&F in replacement Socket outlet 3 pin, 5A, flush type complete all as specified and directed.
S&F in replacement socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts complete all as specified and directed.
S&F in replacement stepped type electronic fan regulator flush type on the existing sheet etc. AC, 230 volts, duly ISI marked with and including connector complete all as specified and directed.
S&F in replacement lamp holder (Angular / Straight), insulated body, with back plate for batten fitting complete all as specified and directed.
S&F in replacement of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge.
S&F in replacement decorative ultra slim linear LED 18 Watt 4' long warm/White colour lighting fixture with extruded al heat sink, environment friendly, energy efficient ready to use pack including LED tube complete with inbuilt electronic driver, PCB, connector block etc. including connecting up three copper flexible cable from ceiling rose to fittings including connecting up and fixed on including two nos PVC square box of required size complete all as specified and directed.
S&F in replacement LED Lamp 9 W complete all as specified and directed.
S&F in replacement sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified and directed.
S&F in replacement MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed.
S&F in replacement MCB, DP (Double Pole), AC, 240 volts, B series capacity 40 Amps to 63 Amps 10kA and making connections complete all as specified & directed.
S&F in replacement MCB, SPN (Single pole neutral), AC, 240 volts, B series capacity 63 Amps 10kA and making connections complete all as specified & directed.
Supply and fixing including taking down old unserviceable 1100 volt grade copper conductor cable single core 1.5 sq mm (three runs) in and including PVC conduit of suitable size complete all as specified and directed Note : Two runs of single core PVC insulated cable with Copper conductor unsheathed cable of size 1.5 Sqmm and one run of 1.5 Sqmm PVC insulated copper conductor single core (earth wire) and one run of PVC conduit of suitable size shall be measured as single unit run for the purpose of measurement
Description All as per item No 69 above but with single core PVC insulated cable with Copper conductor unsheathed cable of size 2.5 Sqmm complete all as specified and directed.
S&F in replacement 1100 volts grade service cable with PVC insulated aluminium conductor 6 Sq mm nominal cross sectional area, 2 core complete all specified and directed.
S&F in replacement 1100 volts grade service cable with PVC insulated aluminium conductor 10 Sq mm nominal cross sectional area, 2 core complete all specified and directed.
S&F in replacement Bed switch 5/6A complete all as specified and directed.
S&F in replacement Plug top 5/6A complete all as specified and directed.
S&F in replacement Plug top 15/16 A complete all as specified and directed.
S&F in replacement casing caping 20 mm complete all as specified and directed.
S&F in replacement heating element Triangle with heating element AC 230 volt of rating 1500/2000 watt ISI marked triangular/circular type complete all as specified and directed.
S&F in replacement thermostat with Thermostat switch for geyser AC 230 volt adjustable range as per sample complete all as specified and directed.
S&F in replacement Bakelite sheet size 3"x5" of 3mm thick complete all as specified and directed.
S&F in replacement Bakelite sheet size 5"x7" of 3mm thick complete all as specified and directed.
S&F in replacement LED Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all specified and directed.
S&F in replacement LED Security light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and Fixing exhaust fan 250 mm sweep PVC body with louver, 240 volts AC single phase, 50 Hz, ISI marked, including necessary cutting work in wall/sheet, including connection cable, nut bolt and other fixing material complete all as specified and directed.
Supply & Fixing of ceiling fan 1200 mm sweep ,copper winding, double ball bearing with aluminium blade set of 3, length of down rod not less then 300 mm, single phase , 240 volts ISI marked , including connection with three core copper wire etc complete all as specified and directed.
M/S SHEIKH FEROOZ AHMAD (BID ID -3054635)
M/S A.N CONSTRUCTIONs (BID ID -3048589)
M/S SMA and SONS CONSTRUCTIONS (BID ID -3063842)
M/S BILAL AHMAD BHAT (BID ID -3055147)
FIRDOUS AHMAD BABA (BID ID -3064150)
M/S Manzoor and Co (BID ID -3054520)
M/S STARE BUILDERS (BID ID -3054898)
M/S ABBAS M. ENTERPRISES (BID ID -3054680)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .