| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹22.0 LAccepted-AOC | l1 | Accepted-AOC L1 | |
| 2 | l2₹34.7 L+₹2.0 L (6.26%)Rejected-Finance | l2 | Rejected-Finance l2 | |
| 3 | l3₹39.3 L+₹6.6 L (20.3%)Rejected-Finance W 701 HARBHAJAN VIHAR AWHO SECTOR 14 SAS NAGAR MOHALI PB 140307 | S A S NAGAR | PUNJAB | 140307 | l3 | Rejected-Finance l3 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-84/2022-2023 ADDN/ALTN TO BLDG NO T-2976 AND OTHER REVENUE MINOR WORKS UNDER AGE B/R I AT CHANDIMANDIR
2022_MES_567781_1
GE/CHM-84/2022-2023
Open Tender
Civil Works
Item Rate
100 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹96,000
Yes
23 Mar 2023
7 Dec 2022
11 Jan 2023
7 Dec 2022
4 Jan 2023
21 Dec 2022
Amount
Demolition of brick work, stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles all as specified & directed by Engineer-in-charge.
Taking down chowkats or frame exc. 1.5 sqm and n exc 4 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
Demolition of reinforced cement concrete of any description in any position as in chajja etc., complete all as specified.
Excavation in trenches not exceeding 1.5m wide and n.exceeding 1.5m deep for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified.
Removal of excavated material to distance not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed.
Brick work with sub class ‘B’ bricks of class designation 7.5 all as per IS-1077-1992 (minimum compressive strength of brick 75kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
Rendering 15mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
15mm thick rendering in Cement and Sand mortar 1:4 over concrete /brick surfaces, finished even and fair without using extra cement including prepartion of new surfce for external finish, taking down old cement plaster and providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
Rendering 15mm thick plaster in cement mortar 1:4 mixed with WPC on concrete roof surfaces and finishing the surface even and fair without using extra cement, all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid separately as supply only).
Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer, complete all as specified & directed.
Reinforced cement concrete 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in beams, cantilevers , bressumers,lintels over 1.5m span, all as specified and directed .
mild steel high strength deformed TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified.
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, all as directed.
Dismantling wrought iron or mild steel as in gates, grills, posts etc or in any description not otherwise provided for, complete all as specified and directed
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc, complete all as specified & directed by Engineer-in-charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips , valley gutters, drip and straight flashing(length and girth as fixed), fixed with self tapping screws complete all as specified & directed by Engineer-in-charge.
Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 t complete all as specified & directed by Engineer-in-Charge
Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified & directed.
Hard core of broken stone or boulders gauge not exc 63 mm deposited spread and lavelled in layers n.exc 15 cm thick, watered & rammed to a true surface complete all as specified.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, sub base and mass concrete complete all as specified & directed.
100mm thick PCC1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base etc, complete all as specified and directed.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground) complete all as specified.
25mm thick cement concrete type B-0, 1:2:4 (using 12.5mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
Non skid ceramic white colour tiles, joint free, first quality, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Coloured vitrified ceramic tiles, light shade, 8-10mm thick (square / rectangular) polished, area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed
Kota Stone Slab flooring, 18 to 20mm thick, minimum size 550 x 550mm, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab, inclduing rubbing and mirror polishing complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed
Glazed ceramic tiles coloured tile in vertical surface, straight cut /edge , size 450mm x 300mm x 7mm thick ,joint free, first quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4 including taking down existing tile complete all as specified and directed.
Powder coated aluminum sections as in frames/ shutter of doors/window/ventilators /partitions, (Openable/Sliding three track) including joinging cleats, glazing clips, rubber neoprene beading, powder coated aluminim snap beading, screws etc. complete all as specified and directed Note : (i) Minimum thickness of power coating shall not be less than 50 micron. (ii) Weight of aluminum section only shall be measuerd and paid. (iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws . (iv) The rate shall be inclusive of neoprene beadings, snap beading, screws, locking roller in case of sliding shutters, arrangement etc. Weight of fitting fixtures will bot be measured for arriving the weight of aluminum section. (v) Glass /wooden panel/ACP sheet shall be measured and paid separately under respective items. (vi) Design as directed by Engineer in charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots / sliding type shutter and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections or sliding type shutters including all wheel and roller arrangements of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
9mm thick pre laminated particle board (ISI Marked), interior grade, pre laminated both side with decorative choice lamination and other side balancing white lamination, fixed as in repair, complete all as specified and directed .
Supply and fix, as in repair, steel window, box type, primer coated, 1.00mm wall thickness, with glazing bar and openable shutter prepared to recieve sheet glass, complete including cutting holes four Nos. for taking down the window ,making good dismantled portion in PCC (1:2:4) type B-1. including following fittings welded to frame/ shutter:- (a) Hold fast 150mm out of 25x6mm flat iron made to shape- 04 Nos. each window (02Nos. on each side). (b) Handle of 'Z' section 20mmx25mm, 100mm long- 01No. each leaf. (c) MS tower bolt 150mm long- 02 Nos. each leaf. (d) 'Z' section 20mmx25mm, 100mm long stopper 01 No. each leaf. (e) Cleat 55mm long of hollow square section 15mmx15mm of 24 guage wall thickness, welded to hinge of 55mm size 01 No. per leaf. (f) MS box type hinges of 75 mm size- 02Nos. per leaf. (g) Fabrication & fixing complete. Note: Glass panes & painting shall be measured & paid separately under respective item.s. Design shall be approved from Engr-in-Charge as existing at site and all as per Drawing before fabrication and bulk order to the manufacturer.
All as per serial item No 37 hereinbefore but window without glazing bar.
Framed work such as grills, gratings, etc with ends of bars shouldered and / or riverted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, raillings, frame work of water tanks and similar work confirming to Fe-290 grade E-165 complete all as specified & directed by Engineer-in-charge.
Door closer hydraulically regulated of aluminium extruded section, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg, complete all as specified and directed.
Door closer hydraulically regulated of aluminium extruded section, designation No. 2, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, complete all as specified and directed.
5.00mm thick ordinary quality tinted glass, fixed to aluminum frame work in panels exc 0.5 Sqm in each pane, complete all as specified & directed.
4mm thick tinted/frosted sheet glass fixed to aluminum frame work with and including standard anodized aluminum bead, rubber packing, aluminum screws etc, in panels n exc 0.5 Square metre in each pane, complete all as specified and directed.
15mm dia GI tubing, medium grade with all fittings , concealed in walls, ceiling or laid under floors including cutting chases and making good in cement mortar (1:3), complete all as specified and directed.
Steel water tubes, 20mm dia bore, concealed medium grade, galvanized, with all standard fittings and fixed complete to walls, ceiling or laid in floors, including taking down old tubing complete all as specified and directed.
Bib taps brass, fancy type, Short body with wall flange, standard chromium plated, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed.
CI floor trap 100mm dia with CP grating including jointing to waste pipe in run lead complete and making good the disturbed surface to match the existing surface, complete all as specified and directed
PVC (SWR) pipe, 75mm bore, single socketed in any length with rubber ring joints, Type B, laid in trenches or in floors including necessary fittings,sealant etc ,fixed in repairs ,complete all as specified and directed.
Single piece EWC of size 360 x 640 x 690mm S-trap with UF seat cover, hinges fixing accessories set, fixed in repairs, all as specified and directed.
Viterous china bowl urinal flat back, size of 465 x 355 x 265mm white (Minimum) with grating and union for discharge pipe including providing & fixing plugs, waste pipe , bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixed as in repair complete all as specified & directed by Engineer-in-charge.
Wash hand basin, vitreous china, flat back, white of size 550 x 400 mm with and including waste coupling, angle brackets, PVC waste pipe, fixed as in repairs, complete all as specified and directed.
15mm dia PVC connection with PTMT nut, of length 450mm, complete all as specified and directed.
Wash hand basin central hole basin mixer , chromium plated with regular spout and pop up waste system, 450mm long braided hoses , suitable for 15mm bore pipe, complete all as specified and directed.
Angular stop cock, brass, cast copper alloy, chromium plated fancy type, screwed both ends for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
500 Litres capacity Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) triple layered , hoisted and fixed in position including PTMT ball valve 20mm bore & PTMT tank nipple, etc, fixed as in repairs, complete all as specified and directed.
Stop valve (concealed type), chromium plated, fancy type, screwed down, high pressure, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
Towel rail cast copper alloy, chromium plated, 20mm dia, 60cm long between flanges complete all as specified and directed.
Waste coupling of PTMT, for WHB any colour half or full threaded suitable for 32 mm/40 mm size discharge pipe (Minimum weight 45 gm) complete all as specified.
PVC waste pipe 800 mm long suitable for 32 mm dia waste coupling, complete all as specified and directed.
Soap dish, vitreous china, white, approximate size 160mm x 160mm x 90mm complete all as specified and directed.
PCC 1:3:6 type C1 (20 mm graded stone aggs) as in roof padding, roof kerbs rounded or chamfered on edges complete all as specified and directed.
Rendering 15mm thick (average thickness) plaster in cement mortar 1:4 on concrete roof surfaces including flashings and junction of parapets etc , finishing the surface even and fair without using extra cement, all as specified and directed by Engineer-in-charge.
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions including dismantling of existing felt /treatment, complete all as specified & directed.
Gypsum Board 10mm thick in ceiling on and including standard GI snap grid powder coated, framed and suspended with 4mm dia wire including clips etc in patterns as approved by GE, in panels of size 605mm x 605mm (GI snap grid consisting of 1mm thick standard GI sections i.e. channel, angle, tee etc for intermediates, parameters etc) supported with 1mm thick standard GI section, fixed in ceiling with necessary fitting and fixtures as per manufacturers instructions, fixed as in repair complete all as specified and directed.
self adhesive water proof texture paint of 100% acrylic latex resin (colour/shade/texture shall be decided by GE) & applying over & including 1mm thick wall care putty as per manufacturer's instruction to exernal surface of bldgs complete all as specified and directed.
Complete removal and preparation of old external surface, including providing scaffolding and safety equipment , complete all as specified and directed.
Surface excavation to required camber and gradient not exceeding 30 cms deep and averaging 15cms deep and getting out in any type of soil, complete all as specified.
Factory made, precast concrete, machine pressed, interlocking paver block any shape and size, conforming to IS 15658-2006, of 60mm thickness, M-35 Grade, with grey cement and no pigment and including laid over 25mm thick sand cushioning, complete all as specified and directed. Notes: The shape/size / colour of paver blocks shall be as approved by the GE.
Factory made, precast concrete, machine pressed, interlocking paver block any shape and size, conforming to IS 15658-2006, of 60mm thickness, M-35 Grade, with grey cement and pigment and including laid over 25mm thick sand cushioning, complete all as specified and directed. Notes: The shape/size / colour of paver blocks shall be as approved by the GE.
Three coats of white wash on wall surfaces including preparation of new plastered surfaces complete all as specified and directed
Excavation in post holes (or similar hole) each in hard and dense soil, n.exc 0.50 cu m getting out and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation of fencing post, filling and mass concrete complete all as specified & directed.
False ceiling fibre cement board, white in colour, of size 595mm x 595mm x 4mm on and including standard GI snap grid, framed and suspended with 4mm dia wire including clips etc in patterns as approved by GE, in panels of size 605mm x 605mm (GI snap grid consisting of 1mm thick standard GI sections i.e. channel, angle, tee etc for intermediates, parameters etc), fixed in ceiling with necessary fitting and fixtures as per manufacturers instructions, complete all as specified and directed.
Plain cement concrete type B-1 (1:2:4) using 20mm graded crushed stone aggregate as in seismic and other similar bands, shelves, copings, bed plates, hold fast, plinth courses and the like finished fair & even, including necessary formwork complete all as specified.
18mm thick solid PVC shutter made out of 18mm celuka printed and UV coated sheet cut according to the size of the cabinet or for kitchen drawer provided and the groove to be made on the one edge so that the overlapping could be done for double leaf shutter including fixing with 1.25" Mild steel screw to the frame with the channel in and including hinge. Handles . complete the work according directions of Engineer-in-Charge, complete all as specified and directed.
Stainless steel powder coated tray of various sizes for drawer to keep the kitchen utensils , all as directed by the Engineer-in-charge .
40mm dia, cupboard knobs of brass, polished, complete all as specified and directed.
Auto close stainless steel (clip hinges) 75mm size suitable for cupboard shutter fixed in position with stainless steel screws, complete all as specified & directed.
Anodises aluminium grills, 7.5mm wide and 6mm thick, fixed to aluminium windows / patition /door frames including all fixing arragements like aluminium channels, screws etc complete all as specified and directed.
Factory made coloured chequered cement concrete tiles 300mm x 300mm x 22-25mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
Point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable in and including surface, non metalic rigid PVC medium grade ISI marked conduit not less than 19 mm bore with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS Box, 1.6mm thick with modular cover plate with frame suitable for modular switches, sockets, fan regulator etc for One light/fan point controlled by one way switch 6 amps 240 volts. Note:- Colour code of wiring should be (for phase -Red, Neutral-black & earth wire green)
All as per Item No 81 here-in-before one 3 pin 6 Amps switch socket out let point on independent board.
All as per Item No 81 here-in-before one 3 pin 6 Amps switch socket out let point on same board.
All as per Item No 81 here-in-before one 6/16 Amps with 2.50 Sqmm FRLSH with 2.50 Sqmm earth wire for switch socket out let point on independent board.
Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
Switch piano, flush type, 16 Amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
Sockets outlet multipurpose 2 in 1 pin, 6 and 16 Amps flush type ISI marked all as specified and directed by Engineer-in-charge
Sockets outlet multipurpose 2 in 1 pin, 6 and 16 Amps flush type ISI marked all as specified and directed by Engineer-in-charge
Stepped type electronic fan regulator flush type complete all as specfied and directed.
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting including 9 watts LED lamp complete all as specified and directed.
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, all as specified and directed by Engr-in charge.
MCB DB, powder coated double door flush pounted complete with locking arrangement suitable for 8 way SPN, 200 Amp 230 volt complete all as specified and dircted.
MCB, SPN, 240 volt, 40Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, fixed in repairs, all as specified..
LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, fixed in repairs, all as specified.
Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified & directed by Engineer-in-charge.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified & directed by Engineer-in-charge.
LED pannel Recess mounted -2'x2' - 36 watts cool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting complee all as specified and directed.
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit after taking out old unserviceable sub main wiring and making good the disturbed surfaces by wall putty/POP after mason work and finshing to match the original finishes ,all as specified and directed. Note : (i) For the purpose of measurement, 3 runs ( Phase, neutral and earth) of single core 10 sqmm cable shall be considered as 1 running metre. (ii) Cutting chases and PVC conduit will be measured and paid separately
Dhingra Brothers
M/s Hari Om Engineer and Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .