Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹1.4 L+₹16,938.59 (13.9%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹1.4 L+₹17,238.92 (14.1%)Rejected-AOC | 3 | Rejected-AOC L3 | |
| 4 | 4₹1.4 L+₹17,697.05 (14.5%)Rejected-AOC | 4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹2,780
Closing Date
21 Mar 2022, 12:00 pmClosed
AE-IV
CANAL COLONY LKO
Roof Water proofing of Kit, V/R, Office, garrage, store and repairing works of Kothi no.- 12 at Canal Colony, Cantt Road, Lucknow.(LOT-18)
2022_UPIDC_678638_18
05/AE-IV/2021-22
Open Tender
Civil Works
Item Rate
7 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹560
₹2,780
13 Apr 2023
15 Mar 2022
21 Mar 2022
15 Mar 2022
21 Mar 2022
15 Mar 2022
Amount
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : including the following works (a) For prepairing the surface Dismantling existing mortar/plaster over roof including disposal of refuse as directed by the Engineer-in-charge with in a distance of 60 meter. (b) 12mm cement plaster in sigle coat on top of slab in single storey building finished even & smooth 1 cement : 4 coarse sand including all L/M, T&P etc . under the Laying of APP sheet .
(C.) Providing and laying 40 mm thick cement concrete flooring with 1:2:4 cement coarse sand and stone ballast 6.7mm nominal size including all material, Labour,T&P and curing complete . over the APP sheet.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work exposed on wall. - 20 mm nominal outer dia Pipes
Providing & fixing of ball valve ( brass) of approved quality, high or low pressure, with plastic float complete. 20 mm nominal bore
Cement Concrete flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc . Complete. 40mm thick with 20mm nominal size stone aggregate.
m/s zaheer construction
MOHD NAIM
M/S KISHORE KUMAR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .