Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAdmitted-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Admitted-Finance | |
| 2 | L2₹15.2 L+₹77,697 (5.38%)Admitted-Finance 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L2 | Admitted-Finance | |
| 3 | L3₹15.2 L+₹79,904 (5.53%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹15.3 L+₹88,636 (6.14%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹15.7 L+₹1.3 L (8.85%)Admitted-Finance OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SAI ENGINEERING WORKS L3 | ARK Enterprises L4 | Udaya Technologies Private Limited L9 | LAKSHMI ELECTRICAL ENTERPRISES L8 | M/s.Sai Agency L7 | EVEREST ENGINEERING WORKS L2 | NAVEEN ENTERPRIESES L5 | vijay kumar gupta and co L1 | GK ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5m in width and 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 280.8 | cum | 160 ₹44,928 | 170 ₹47,736 | 663 ₹1,86,170.4 | 390 ₹1,09,512 | 107 ₹30,045.6 | 320 ₹89,856 | 270 ₹75,816 | 100 ₹28,080 Lowest | 180 ₹50,544 |
| 2.00 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed. | 174.6 | cum | 120 ₹20,952 | 75 ₹13,095 | 663 ₹1,15,759.8 | 170 ₹29,682 | 80 ₹13,968 | 45 ₹7,857 | 60 ₹10,476 | 25 ₹4,365 Lowest | 100 ₹17,460 |
| 3.00 | Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete including taking down u/s one all as specified and directed. | 106.2 | cum | 45 ₹4,779 | 75 ₹7,965 | 442 ₹46,940.4 | 110 ₹11,682 | 80 ₹8,496 | 70 ₹7,434 | 60 ₹6,372 | 25 ₹2,655 Lowest | 60 ₹6,372 |
| 4.00 | DWC ( Double wall corruguated) pipe 50 mm dia conforming to IS:14930/ IS 16205 for protection of earth strip including necessary snap-fit coupler required for fixing complete all as specified and as directed. | 1,000 | RM | 35 ₹35,000 Lowest | 55 ₹55,000 | 141.53 ₹1,41,530 | 100 ₹1,00,000 | 350 ₹3,50,000 | 77 ₹77,000 | 110 ₹1,10,000 | 50 ₹50,000 | 115 ₹1,15,000 |
| 5.00 | Taking down the existing damage/ unservicable LT under groung cable of any description of the following size from trenches/ walls (or) passing through pipes/in floor and depositing where directed at site and size 6 sqmm x 2 core all as specified and directed by the Engr-in- charge
Note:- Excavation and Earth work shall be measured and paid separately under appropriate items | 600 | RM | 25 ₹15,000 | 50 ₹30,000 | 20.4 ₹12,240 | 60 ₹36,000 | 35 ₹21,000 | 10 ₹6,000 Lowest | 20 ₹12,000 | 10 ₹6,000 Lowest | 20 ₹12,000 |
| 6.00 | All as per item No.5 above but 6 sqmm 4 core | 350 | RM | 120 ₹42,000 | 50 ₹17,500 | 20.4 ₹7,140 | 60 ₹21,000 | 35 ₹12,250 | 10 ₹3,500 Lowest | 20 ₹7,000 | 10 ₹3,500 Lowest | 20 ₹7,000 |
| 7.00 | All as per item No.5 above but 10 sqmm 4 core | 150 | RM | 145 ₹21,750 | 50 ₹7,500 | 20.4 ₹3,060 | 50 ₹7,500 | 53 ₹7,950 | 15 ₹2,250 | 20 ₹3,000 | 10 ₹1,500 Lowest | 20 ₹3,000 |
| 8.00 | All as per item No.5 above but 16 sqmm 4 core | 100 | RM | 230 ₹23,000 | 50 ₹5,000 | 25.5 ₹2,550 | 60 ₹6,000 | 53 ₹5,300 | 15 ₹1,500 | 20 ₹2,000 | 10 ₹1,000 Lowest | 20 ₹2,000 |
| 9.00 | All as per item No.5 above but 25 sqmm 4 core | 100 | RM | 260 ₹26,000 | 50 ₹5,000 | 25.5 ₹2,550 | 60 ₹6,000 | 80 ₹8,000 | 15 ₹1,500 | 20 ₹2,000 | 10 ₹1,000 Lowest | 20 ₹2,000 |
| 10.00 | Laying only the under ground cable any type obtained from Items No -05 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc and size 6 sqmm 2 core complete all as specified and directed by Engr-in Charge . | 85 | RM | 30 ₹2,550 | 50 ₹4,250 | 68.85 ₹5,852.25 | 80 ₹6,800 | 80 ₹6,800 | 10 ₹850 Lowest | 25 ₹2,125 | 40 ₹3,400 | 30 ₹2,550 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
18 Jul 2026, 6:55 pmClosed
GE Chennai
GARRISON ENGINEER FORT SAINT GEORGE CHENNAI - 600009
REPAIRS / MAINT / REPLACEMENT OF PATHWAY LIGHTS , BOLLARDS SECURITY LIGHT FIXTURES UNDER GE CHENNAI
2026_MES_773762_1
8935/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Chennai
As per tender documents
7 documents required · 7 mandatory
₹500
GE Chennai
₹40,000
Yes
14 Aug 2026
20 Jun 2026
20 Jul 2026
20 Jun 2026
18 Jul 2026
4 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5m in width and 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 280.8 | cum | - | - |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed. | 174.6 | cum | - | - |
| 3 | Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete including taking down u/s one all as specified and directed. | 106.2 | cum | - | - |
| 4 | DWC ( Double wall corruguated) pipe 50 mm dia conforming to IS:14930/ IS 16205 for protection of earth strip including necessary snap-fit coupler required for fixing complete all as specified and as directed. | 1,000 | RM | - | - |
| 5 | Taking down the existing damage/ unservicable LT under groung cable of any description of the following size from trenches/ walls (or) passing through pipes/in floor and depositing where directed at site and size 6 sqmm x 2 core all as specified and directed by the Engr-in- charge
Note:- Excavation and Earth work shall be measured and paid separately under appropriate items | 600 | RM | - | - |
| 6 | All as per item No.5 above but 6 sqmm 4 core | 350 | RM | - | - |
| 7 | All as per item No.5 above but 10 sqmm 4 core | 150 | RM | - | - |
| 8 | All as per item No.5 above but 16 sqmm 4 core | 100 | RM | - | - |
| 9 | All as per item No.5 above but 25 sqmm 4 core | 100 | RM | - | - |
| 10 | Laying only the under ground cable any type obtained from Items No -05 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc and size 6 sqmm 2 core complete all as specified and directed by Engr-in Charge . | 85 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
BOQ_866397.xls
BOQ • 0.26 MB
Tender8935.pdf
Tender Documents • 0.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .