Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹32.0 L+₹3.4 L (12.0%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹33.4 L+₹4.8 L (16.8%)Rejected-AOC NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-AOC L3 | |
| 4 | L4₹34.9 L+₹6.2 L (21.8%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹36.4 L+₹7.8 L (27.2%)Rejected-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-AOC L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
22 Feb 2020, 6:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING COOLING/HEATING APPLIANCES IN DRDO ESTATE PASHAN
2020_MES_318277_1
GERD/PSN/TOKEN/56 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
GERD PASHAN PUNE
₹70,000
Yes
25 Jul 2020
25 Jan 2020
24 Feb 2020
25 Jan 2020
22 Feb 2020
17 Feb 2020
25 Jan 2020 - 7 Feb 2020
Amount
Taking down carefully copper/AIuminium point wiring (Light,Fan/Point Socket or power) including (swtiches, sockets, regulators, bell, bell push any size) and keep the same for shcedule of credit and making good to disturbed surface of walls/floors etc.complete all as specified and directed.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as ceiling fitting, bulk head fittings and tube light/ light fittings etc and making good the distrubed surfaces complete all as specified and directed.
Taking down carefully existing ceiling fan/ Exhaust fan any size from site and keeping in safe custody for reuse at site complete all as specified and directed.
Material and labour for Cleaning dust, removing of cavaties and painting of Ceiling fan any size taking down under item No 3 with and including synthatic enamel paint by spraying complete all as specified and directed.
Taking down existing unserviceable MCCBs/ MCB DBs complete including making surface good complete all as specified and directed.
Material and labour for point wiring using approved colour coding as per IS with and including stranded copper conductor single core 1.5Sqmm (Nominal area), PVC insulated FRLS cable in and including surface PVC casing-n-caping ISI marked medium grade with and including all connecting accessories as required at site complete, including PVC insulated copper conductor 1.5 Sqmm (Nominal area) single core PVC FRLS cable as earth continuity conductor to common earth and connecting to earth dolly as below complete all as specified and directed Note : Sunken bords/ Switch/sockets and other related items to be measured and paid for separately (Modular):- (a) One light point controlled by one ; one way switch
(b) One Fan/Exhaust point controlled by one ; one way switch
(c) One 3 pin 5 Amp socket out let controlled by one switch on independent board.
(d) One 3 pin 5 Amp socket out let controlled by one switch but on same board.
(e) One bell/buzzer point controlled by one push button.
All as per item 6 here-in-before but with 2.5 sq mm size pvc insulated and unsheathed 1100 volts grade FRLS single core stranded ( multistranded ) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continues run of PVC insulated green in colour 2.5 sq mm multistranded copper conductor earth wire connecting to earth dolly complete all as specified and as directed.
Material and labour for point wiring complete with single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC casing capping Tee junction bends etc fixing to wall/roof and PVC switch board / hylam sheet of 3 mm thick in existing M.S. sunken boards of suitable size for housing switch sockets etc including 1.5 sqmm. green PVC insulated wire for earth continuity complete all as specified and as directed for the followings:- (a) One light point controlled by one ; one way switch
(b) One Fan/Exhaust point controlled by one ; one way switch
(c) One 3 pin 5 Amp socket out let controlled by one switch on independent board.
(d) One 3 pin 5 Amp socket out let controlled by one switch but on same board.
(e) One bell/buzzer point controlled by one push button.
(f) One light point controled by two way switch
All as per item 12 here-in-before but with 2.5 sq mm size pvc insulated and unsheathed 1100 volts grade FRLS single core stranded ( multistranded ) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continues run of PVC insulated green in colour 2.5 sq mm multistranded copper conductor earth wire connecting to earth dolly complete all as specified and as directed.
Material and labour for point wiring complete with and including single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade FRLS in existing conduit pipe wall/roof and PVC switch board / hylam sheet of 3 mm thick in existing M.S. sunken boards of suitable size for housing switch sockets etc including 1.5 sqmm. green PVC insulated wire FRLS for earth continuity will be replaced for the following complete all as specified and as directed. (Note : Switch/sockets to be measured and paid for separately) :- (a) one light point controlled by one; one way switch.
(b) one fan/Exhaust point controlled by one; one way switch.
(c) one 3 pin socket out let 5 amp independent point
(d) one 3 pin socket out let 5 amp point on the same board with other switches.
(e) One bell/buzzer point controlled by one,one way switch on independent board.
(f) one light point controlled by two; two way switch for stair case.
All as per item 19 above but with and including 2.5 sq mm size pvc insulated and unsheathed 1100 volts grade FRLS single core stranded ( multistranded ) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continues run of PVC insulated green in colour 2.5 sq mm multistranded copper conductor earth wire connecting to earth dolly complete all as specified and as directed.
Supply and fix switch piano, flush type, 5 Amp, single pole, two way complete all as specified and directed.
Supply and fix switch piano, flush type, 6 Amp, single pole, one way complete all as specified and directed.
Supply and fix socket 5 pin 6 Amp surface type complete all as specified and directed.
Supply and fix Swich socket combination 5 pin 6 Amp surface type complete all as specified and directed.
Supply and fix switch piano flush type, single pole 1 way 16 Amp complete all as specified and directed.
Supply and fix socket out let 2 in one 6 pin 6 and 16 Amp complete all as specified and directed.
Supply and fix bell push, 6 Amps, SP, flush type. complete all as specified and directed.
Supply and fix Lamp holder insulated body with back plate.complete all as specified and directed.
Supply and fix ceiling rose, surface bakelite, 3 terminals, 65 mmx50mm complete all as specified and directed.
Supply and fix Electric Bell , AC 230 volts, single pole complete all as specified and directed.
Supply and fix stepped type electronic fan regulator flush type on the existing/new phenolic sheet etc as required at site complete all as specified and directed.
Supply fixing , testing of new sheet metal enclosure distribution board SPN 4 way double door type including making good to the disturbed surface all as specified and as directed Note : All incoming/out going MCBs shall be measured and paid under appropriate item here in after.complete all as specified and directed.
Supply , fixing , testing of new sheet metal enclosure distribution board SPN 8 way double door type including making good to the disturbed surface all as specified and as directed Note : All incoming/out going MCBs shall be measured and paid under appropriate item here in after.complete all as specified and directed.
Supply , fixing , testing of new sheet metal enclosure distribution board SPN 12 way double door type including making good to the disturbed surface complete all as specified and directed Note : All incoming/out going MCBs shall be measured and paid under appropriate item here in after.
Supply , fixing and testing of new sheet metal enclosure distribution board TPN 4 way double door type alongwith 63 Amp/100 Amp MCCB 4 pole including making good to the disturbed surface complete all as specified and directed Note : Out going MCBs shall be measured and paid under appropriate item here in after.
Supply and fix MCB single pole 3-40 Amps capacity 10 KA, 240 Volts AC 50 Hz complete all as specified and directed.
Supply and fix MCB single pole and neutral 20 to 40 Amps capacity 10 KA, 240 Volts AC 50 Hz complete all as specified and directed.
Taking down sub main wiring of any size carefully complete and making good disturbed surface of walls /ceilings etc. and catered for schedule of credit.complete all as specified and directed.
Material and labour for sub main wiring using two single core 6 sqmm copper conductor,FRLS cable in including PVC casing caping of suitable size,including one run of PVC insulated copper earth continuity wire of 6.0 sqmm and connected to earth dolly including cutting chases for concealed conduit wiring complete all as specified and as directed. Note: 2 run of 6 sqmm ( 01 for phase and 01 for neutral) with 1 separate run of 6 earth wire and one run of PVC conduit will be measured as one unit.complete all as specified and directed.
Material and labour for Sub main wiring complete with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed cable 1100 V grade with and including multistranded copper conductor ISI marked drawn through PVC casing and capping / PVC conduit accessories fixed on surface/wall celing etc including provision of 1 run of 2.5 Sqmm PVC insulated unsheathed cable with and including multistranded copper conductor as earth continuity.complete all as specified and directed. Note: 2 run of 2.5 sqmm ( 01 for phase and 01 for neutral) with 1 separate run of 2.5 earth wire and one run of PVC conduit will be measured as one unit.
Material and labour for sub main wiring using two single core 6 sqmm copper conductor,FRLS cable drawn through existing PVC casing caping/ conduit of suitable size,including one run of PVC insulated copper earth continuity wire of 6.0 sqmm and connected to earth dolly including cutting chases for concealed conduit wiring complete all as specified and as directed. Note: 2 run of 6 sqmm ( 01 for phase and 01 for neutral) with 1 separate run of 6 earth wire and one run of PVC conduit will be measured as one unit.
Material and labour for Sub main wiring complete with and including 2 runs of 2.5 Sqmm single core PVC insulated unsheathed cable 1100 V grade with and including multistranded copper conductor ISI marked drawn through existing PVC casing caping/ conduit fixed on surface/wall celing etc including provision of 1 run of 2.5 Sqmm PVC insulated unsheathed cable with and including multistranded copper conductor as earth continuity. complete all as specified and directed Note: 2 run of 2.5 sqmm ( 01 for phase and 01 for neutral) with 1 separate run of 2.5 earth wire and one run of PVC conduit will be measured as one unit.
Material and labour for Submain wiring with and including 2 run of single core 2.5 sq mm PVC insulated unsheathed cable 1100 volt grade with and including multistranded copper conductor drawn through 20mm GI pipe in trench and including provision of 2.5 Sq mm PVC insulated copper wire as earth continuity conductor to the common earth doly complete all as specified and directed. Note : GI Pipe 20mm dia will be measured sapartely (garden light)
Supply and fix surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with and including polycarbonate diffuser and integrated electronic driver, 20 Watt 230V complete with and including all accessories internally prewired and provision of flexiable three core copper conductor 23/0.0076 upto 1.5metre from celing rose to fitting complete all as specified and directed. (Make: Cat No LUMILINEPLUS BS20W LED 865 SPC SS of Havell's or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with and including polycarbonate diffuser and integrated electronic driver, 22 Watt 230V complete with and including all accessories internally prewired and provision of flexiable three core copper conductor 23/0.0076 upto 1.5metre from celing rose to fitting complete all as specified and directed. (Make: Cat No LUMILINEPLUS BS22W LED 865 SPC SS of Havell's or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with and including polycarbonate diffuser and integrated electronic driver, 18 Watt 230V complete with and including all accessories internally prewired and provision of flexiable three core copper conductor 23/0.0076 upto 1.5metre from celing rose to fitting complete all as specified and directed. (Make: Cat No LUMILINEPLUS BS18W LED 865 SPC SS of Havell's or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix decorative wall light fixture made up of Polycarbonate unbreakable, suitable for 09W LED lamp complete with pre-wired and including 09W LED lamp energy efficient ready to use pack,complete all as specified and directed Make - Cat No LUMILINE BS 9W LED 865 SPC WH of Havells or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix decorative ultra slim round profile LED lighting fixture with and including co extruded polycarbonate body duly prewired complete of 15 watt LED lighting fixture environmental friendly energy efficient ready to use pack complete all as specified and directed, (Make - Cat No ENDURANEOHESURFACED LS 15WLED 840S of Havells or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix energy saving new generation 10W LED IP-65 bulkhead luminaire with and including opal diffuser, with lamp holder etc complete with and including all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50Hz,complete all as specified and directed Make - Cat No HEXAFT 10W LED 857 SSYMBOPC of Havells or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix in repairs new LED building security luminaries 20 watts pressure die cast aluminum housing with IP 66 and replaceable integrated electronic driver LED as light sources housing complete with and including all accessories internally prewired complete all as specified and directed. Make:- Cat Part No : ENDURAPEARLSL 20W LED 757 SASY TO PCMP of Havells or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix in repairs of street light bracket made out of 25 mm/32mm dia medium grade GI pipe of 1.5 metre long bend to shape including MS flat iron clamp made out of 20mm x3mm and all fixing arrangement to fix with pole any type/height/wall complete all as specified and directed.
Material and labour in repair for Earthing complete with and including galvansied steel earth plate electrode 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below ground level earth plate connected with and including 4 mm dia GI wire as earthing lead by means of bolts, nuts, check nut and wahers of galavanised iron all as shown in Electrical plate No.3 of MES Sch part I and testing on completion. Including neccessary excavation and earth work, adequate common slat, charcoal dust and funnel PCC (1:3:6) type C-1 using 40mm graded crushed stone aggregate pit with pre-cast RCC (1:2:4) type B-1 cover using 20mm graded crushed stone aggregate, 40mm thick reinforced with 8 mm dia bars, MS bar 3 Nos both ways funnel with 20 mm dia GI grade watering pipe earthing lead with and including GI protection pipe light grade 15mm dia up to 7.5meter. from earth plate to equipment earth point complete all as specified and directed.
Taking down carefully electric water heaters (Gysers) 25 liter/35 liter/50 liter capacity of any make and type including disconnecting electric and water connections and dismantiling re-assembling refixing and testing complete after doing the following as directed Engr-in-Charge and as specified compresing of :- (a) Descalling the inner water tank complete and testing at a pressure of 43 PSI. (b) Descalling of heating element (c) Checking all electrical connections (d) Spares to be replaced shall be measured and paid saparately as "supply only" .
Supply only heating elements of capacity 1.5 KW / 2 KW for any type of Geysers ISI marked complete all as specified and directed Make :- Recold/Ramson/Usha/Crompton Greaves.
Supply only thermostate for geysers, ISI marked complete all as specified and directed Make : Recold/Ramson/Usha/ crompton Greaves.
Supply only indicator lamp 230 volt square or round shape for geysers complete all as specified and directed.
Supply only copper flexible cable PVC insulated 3 core 40/0.0076 and connecting complete all as specified and directed Make of wire : Finolex/Kalinga Plaza/Paragon.
Supply only plate assembly with inlet and outlet and provision for thermostat housing rubber nuts, bolts and washers of required size complete for 25 liter/35 liter capacity geysers complete all as specified and directed Make : Recold/Ramson/Usha/Crompton Greaves.
Supply only PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed Make : Prayag/Polytuff
Supply only fusible plug (safety valve) for Geysers of any capacity complete all as specified and directed.
Supply and fix single pole and neutral enclosure with and including two pin and earth plug and socket complete with one single pole MCB of 16/ 20 Amp metal enclosed industrial typecomplete all as specified and directed.
Supply and fix in repair GI tubing 20mm light grade ISI marked laid in trench for insetion of 2.5 Sqmm 3 run wire to connect garden light inncluding all accessories required as per route of wire complete all as specified and directed.
Supply and fix decorative LED light fitting of 08 watt for garden/path including suitable LED Lamp complete in all respect complete all as specified and directed, (Make : Cat Part No BA MBOOBLS8W LED 830 PSY MTOPC of Havells Havells or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix (in repair) pole junction box sheet moulded compound (SMC) type with and including hinged door and locking arrangement of size 140 mmx140 mmx100mm internal comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loopin and loop out suitable for single phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25mmx3mm MS flat iron complete all as specified and directed. Make : Sintex or equivalent as approved by GE.
Material and labour for PCC1:2:4 type C1 using 20mm graded crushed stone aggregate for post size (300x300x500)mm and necessary form work suitable for fixing garden light complete all as specified and directed.
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine and carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising complete all as specified and directed of the following:- (a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor and applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete (b) Spare parts required to be replaced will be measured and paid separately as "supply only" (c) Rewinding and painting shall be measured and paid for separately.
Material and labour for re-winding of ceiling fan any sweep with existing guage supper enameled copper wire to maintain speed at load complete all as specified and directed.
Material and labour for Painting of ceiling fan any sweep taking down vide item No 74 by applying one coats of synthetic enamel paint after preparation of surface complete all as specified and directed.
Suply only ball bearings for exhaust/ceiling fan of any sweep. complete all as specified and directed. Make : SKF/NBC/FAG
Suply only GUN METAL BUSH for exhaust / ceiling fan of any sweep.complete all as specified and directed.
Suply only fan condenser 2.5/4 mfd complete all as specified and directed.
Suply only rubber reel, nut bolts, washer, split pin complete complete all as specified and directed.
Suply only Fan connector suitable for wire connection.complete all as specified and directed.
Taking down the existing un-serviceable ceiling fan of any sweep deposited to MES store and supply and fixing new ceiling fan 1200 mm sweep single phase 230 volts, 50 Hz 5 star rated with new copper connection wires complete all as specified and directed. Make : Cat ES Neo of Havells or equivalent in make as specified in Appendix 'B' as approved.
Supply and fix in repair LED 25Watt post top lantern (gate light) energy saving, environment friendly designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed. (Make:- Havell's cat part No RUBYPT25WLED757PSYMTOPC or equivalent make as specified in Appendix 'B' as approved.
Supply , Laying, connecting, testing and Commissioning XLPE insulated, earthed, screened, PVC bedded, galvanised steel strip or wire armoured electrical LT cable size 10 Sqmm 2 core (heavy duty) with and including stranded aluminum conductor 1100 volts grade complete all as specified and directed NOTE :- Excavation, earthwork sand cushioning and cable protection will be measured and paid separately.
Excavation in trenches not exceeding 1.5metre wide and not exceeding 1.5metre deep for foundation of poles, cables, pipes stays and struts etc, and getting out complete all as specified and directed for following type or soil:- (a) Soft / loose soil.
(b) hard/ dense soil
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50 metre depositing where directed at a level not exceeding 1.5metre above the starting point complete all as specified and directed.
Material and labour for sand cushioning using fine dry sand complete all as specified and directed. Competed thickness 18 cm shall be measured.
Supply and laying sub class B bricks, old size, laid flat adjacent to each other, perpendicular to cable with width equal to length in trenches for protection of cable complete all as specified and directed.
Supply and fix GI pipe 40 mm dia light grade for passing the cable from road/ wall/ poll/ trench for cable safety complete all as specified and directed.
Supply and fix recess mounting LED 2X2 luminaire of 35/36w ,230v , skylight type, white powder coated aluminium extruded housing with LED including drivers etc complete in all respect and accessories, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with 1.5 sqmm size complete all as specified and directed.
Supply and fix in repair Modular switch piano 6A Amps flush type single pole one way complete all as specified and directed.
Supply and fix in repair modular socket 2in1,3 pin, 5/6 Amp, flush type complete all as specified and directed.
Supply and fix in repair Modular switch 1 way 16 Amps , 230 V complete all as specified and directed.
Supply and fix in repair modular socket out let 2in1,3 pin, 6 and 16 Amp, flush type complete all as specified and directed.
Supply and fix in repair Modular bell push 6 amps, complete all as specified and directed.
Supply and fix in repair Modular fan regulator Electronics step type 120 watts and connecting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Modular cover plate with suitable frame complete all as specified and directed as per following:- (a) White cover plate with frame, 1 module
(b) White cover plate with frame but 2 module
(c) White cover plate with frame but 3 module
(d) White cover plate with frame but 4 module
(e) White cover plate with frame but 6 module
(f) White cover plate with frame but 12 module
Supply and fix in repair Modular metal flush box with suitable size complete all as specified and directed as per following:- (a) Metal flush box 1/2 module.
(b) Metal flush box but 3 module
(d) Metal flush box but 4 module
(e) Metal flush box but 6 module
(f) Metal flush box but 12 module
Material and labour for servicing the window type AC 1.5 TR/2.0 TR at site,cleaning evaporator,condensing coil by using carbon tetra chloride,combing the evaporator,condensor fins,greasing all the moveable parts of fan motor,testing the wiring of whole AC,checking all parts,cleaning the air filter and replacing the unserviceable spare parts,including cleaning the tray and refixing the AC back in position by providing proper packing for better effects,testing and commissioning of AC complete all as specified and directed. Note :- (i) Spare parts required to be replaced shall be measured and paid for separately as "supply only". (ii) Gas including charging shall be measured and paid for separately.
Material and labour for disconnecting the water cooler of cap 40 liter/80 liter/Hour from electric and water connection at site and servicing the water cooler by cleaning condensor by using carbon tetra chloride combing the evaporator condensor fins ,cleaning of water storage tanks greasing all the moveable parts of fan motor,testing the wiring and checking all parts and replacing the unserviceable spare parts including cleaning the tray and fixing back water cooler in position,testing and commissioning of water cooler complete all as specified and directed. Note :- (i) Spare parts required to be replaced shall be measured and paid for separately as "supply only". (ii) Gas including charging shall be measured and paid for separately.
Material and labour for disconnecting the Refrigerator of capacity 165 liters/190 liters/215 Liters from electric connection at site and servicing the refrigerator by cleaning condensor by using carbon tetra chloride combing the evaporator condensor fins , cleaning internally, greasing all the moveable parts of fan motor,testing the wiring and checking all parts and replacing the unserviceable spare parts including testing of refrigerator complete all as specified and directed. Note :- (i) Spare parts required to be replaced shall be measured and paid for separately as "supply only". (ii) Gas including charging shall be measured and paid for separately.
Material and labour for servicing the split type AC 1.5 TR/2.0 TR at site,cleaning of indoor/ out door units,evaporator,condensing coil by using carbon tetra chloride,combing the condensor fins,greasing all the moveable parts of fan motor,testing the wiring of whole AC,checking all parts,cleaning the air filter and replacing the unserviceable spare parts,including cleaning the tray and refixing the AC back in position by providing proper packing for better effects,testing and commissioning of AC complete all as specified and directed. Note :- (i) Spare parts except drain pipe, FHP/blower motor required to be replaced shall be measured and paid separately under respective items as "Supply only". (ii) Supply and charging of gas shall be measured and paid for separately.
Supply only the following parts/components of window type AC/Split AC/Refrigrator and Water cooler of approved make to be incorporated against item Nos 113 TO 116 here-in-before complete all as specified and directed:- (a). Hermetically sealed compressor of single phase electrically operated on 230 V,suitable for the 1.5 TR capacity window/split type AC(Make-Shriram,Tecumesh,Kirloskar,Voltas to suit the model of AC/Water cooler at site.) complete all as specified and directed.
(b). Hermetically sealed compressor of single phase electrically operated on 230V, suitable for the 40 liters to 80 liters water cooler.(Make-Shriram,Tecumesh,Kirloskar,Voltas to suit the model of AC/Water cooler at site.)complete all as specified and directed.
(c). Auto cut thermostat for window type AC(Make: Shriram/Annapurna/Ranutrol) complete all as specified and directed.
(d). Auto cut thermostat for water cooler(Make: Shriram/Annapurna/Ranutrol) complete all as specified and directed.
(e) Box type relay suitable for window type AC (Make: Shriram/Annapurna/Ranutrol) complete all as specified and directed.
(f) Relay suitable for water cooler(Make: Shriram/Annapurna) complete all as specified and directed.
(h) Filter pad for window/split type AC complete all as specified and directed.
(j) Capacitor 230 V AC SH type complete all as specified and directed of following capacity :- (i) Capacitor of capacity 4 mfd( Make -Ketron/Usha/Kelltron/Asian)
(ii) Capacitor of capacity 6.3 mfd( Make -Ketron/Usha/Kelltron/Asian)
(iii) Capacitor of capacity 36 mfd( Make -Ketron/Usha/Kelltron/Asian)
(k) Starting capacitor AC 230/415V, 60 to 80 mfd (Make -Ketron/Usha/Kelltron/Asian)
(l) Starting capacitor AC 230/415V, 80 to 100 mfd( Make -Ketron/Usha/Kelltron/Asian)
(m) Running capacitor AC 230/415V, 40 to 60 mfd( Make -Ketron/Usha/Kelltron/Asian)
(n) Foundation rubber bushes for compressor of window type AC
(o) Capillary copper tube with strainer for window/split type AC or water cooler.
(p) Potential thermal coefficient relay
(q) Fan blade sheet metal of suitable size for AC unit/water cooler
(r) PCB kit(Remote circuit) for split AC of any type including Remote.
(s) Push cock stainless steel for water cooler 15 mm bore
(t) Annealed copper tubing of size 3/8 inch outer dia
(u) Annealed copper tubing of size 5/8 inch outer dia
(v) Front grill matching with existing AC.
(w) Hermetically sealed compressor of single phase electrically operated on 230 V,suitable for the 2 TR capacity window/split type AC (Make-Shriram,Tecumesh,Kirloskar,Voltas to suit the model of AC/Water cooler at site.)
Supply and fix in repairs for suitable size and standard length of flexible drain pipe of PVC for split type AC of any capacity complete all as specified and directed.
Supply and fix in repair FHP motor for indoor unit of split type AC to match with existing motor of any make after removing the old unserviceable motor complete all as specified and directed.
Supply and fix in repair blower motor ductable AC motor 0.5 HP capacity for indoor unit of split type AC to match with existing motor of any make after removing the old unserviceable motor complete all as specified and directed.
Supply and charging R-22 gas in returnable gas cylinder for window/split AC including sealing complete all as specified and directed.
Supply and charging C-134 gas in returnable gas cylinder for Water coolers/Refrigerators including sealing complete all as specified and directed.
Material and labour for flushing out refrigerant pipes, vacuuming the hermitically sealed compressor, charging of refrigerant (Freon-12) in adequate quantity, connecting suction and discharge lines and conducting leakage test for refrigerator of 165 liter/190 liter/215 liters capacity complete all as specified and directed.
K D Electricals
ASHA ASSOCIATES
M/S EAGLE ENTERPRISES
SKS Electricals
Borole Electricals
M/S DHEER ENGINEERING
R. K. Industrial Fabricators
Star Electrical
M/s Vijay Airconditioning Pvt Ltd
MAYUR ELECTRIC SERVICES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .